PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Similar documents
PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Device Compatibility Guide

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Vigilant MX4428 Fire Alarm System

2004 AUSTRALIAN STANDARDS UPDATE

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

FireFinder TM AS OPERATORS MANUAL

Solution F2. Fire Alarm Control Panels one step ahead.

Certificate of Conformity Certificate num. Registration date Version Valid until

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Certificate of Conformity Certificate num. Registration date Version Valid until

Technical Data Sheet

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

4100U Fire Indicator Panel Australian Wiring Diagrams

Precept Marine Control Panel Application Guide

AU MX Digital Loop Card Installation Instructions

CCU Family of Modules

IGD.CO.UK

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TrueAlarm Fire Alarm Systems

AFP-2800/2802 Fire Alarm Panel

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning. Part 1: Fire AS 1670.

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets...

Fire Alarm Control Panels

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

The EN54 Part 2 & 4 Fire System

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Touch Screen 1 loop Addressable Fire Alarm Panel

HART XL High Sensitivity Smoke Detection

OPERATION / INSTALLATION

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

4100ES Fire Indicator Panel Installation & Maintenance

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

DS7400Xi Addressable Control/ Communicator

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

TrueAlarm Fire Alarm Controls

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

Wireless Fire Solutions

I NSTALLATION M ANUAL

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Addressable Fire Alarm Control Panel

LifeAlarm Fire Alarm Control Panels

4120 Fire Alarm Network Reference

Series 65 Product Guide MAN 3036

Solution F1. Fire Control Panels the new generation

20 Light Remote Annunciator

Installation, Operating and Maintenance Manual

Sigma XT+ Extinguishant Control Panel. Operation and Maintenance Manual

Operating Instructions

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

RTD TEMPERATURE SENSING SYSTEM

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TrueAlarm Smoke Detectors

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

HART XL High Sensitivity Smoke Detection

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

MINERVA MZX125. Digital Addressable Fire Detection System

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

LaserFOCUS VLF-250 Engineering Specification

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

Network Display Unit Installation Instructions

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

/ XPS Interconnection Diagrams

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ID50series. intelligent fire alarm panels

VESDA VLP. Engineering Specification

OPERATION AND INSTALLATION MANUAL

/9308 External Battery Chargers Installation Instructions

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

4010 Fire Alarm Parts List

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Fire and Gas Monitoring Panel ST7-HV

TrueAlarm Analog Sensing

P R O D U C T D ATA S H E E T

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

P R O D U C T D ATA S H E E T

FS-1600 Fire Alarm Panel

Sigma CP (K and T Series)

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

APPLICATION DATA SHEET

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Transcription:

LISTING NUMBER afp - 1421 Commonwealth Scientific and Industrial Research Organisation, Australia Ph.: 61 3 9252 6000 Fax: 61 3 9252 6011 Web site: http://www.activfire.gov.au E-mail: info@activfire.gov.au Dates: Registration:...17-May-2001 Page 1 of 6 Version:..1.8...1-Aug-2007 Valid until :...31-Jul-2008 PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment) Product designation Simplex, Model F3200, fire indicator panel (Refer to the Technical Specification section of this document for further specific detail) Supplier Simplex Fire Products 47 Gilby Road, MOUNT WAVERLEY, VIC, AUSTRALIA, 3149 Manufacturer Tyco Safety Products 17 Mary Muller Drive, CHRISTCHURCH, NEW ZEALAND, 8241 Supplier's description The Simplex, Model F3200, fire indicator panel is a microprocessor based fire indicator panel (FIP), fitted with a 2 line, 40 character alpha-numeric liquid crystal display, and membrane keyboard. The FIP can be fitted with a total of 8 plug-in modules, each being either an 8 Alarm Zone Circuit module with an open collector output per zone, or an 8 Relay Module. The total system capacity is 64 alarm zones. The FIP can optionally incorporate 16 zone LED display boards to give a total display capacity of 64 zones. Provision is made for up to 8 Remote Zone Display Units (RDU) to be used for repeater indicators and control. A VDU/printer port is available for data access. A network kit is available which allows a network of up to 64 F3200 panels, PTMs, NDUs and other Vigilant Panellink compatible products to be interconnected. The network uses a duplicated RS485 link. Ring networking using a single RS485 pair, fibre optic cables, or other media, is available by using the I-Hub networking module. A Network Display Unit (NDU) is essentially a networked F3200 FIP without any 8 Zone or 8 Relay Modules able to be connected. It is available as a slimline unit or in the standard cabinets with its own MAF/PSU. The NDU can be used as a master panel (e.g. for fire brigade connection) on a network. Two different product ranges are available; one complies with AS 1603:Part 4-1987 and AS 4050(Int)-1992, the other with AS 4428:Part 1-1998. Conformance criteria and evaluation The Simplex, Model F3200, fire indicator panel complies with the requirements of Australian Standard AS 4428.1-1998, 'Fire detection, warning, control and intercom systems, Control and indicating equipment, Fire', Australian Standard AS 1603.4-1987, including amendment numbers 1 and 2, 'Automatic fire detection and alarms systems, Control and indicating equipment' and Australian Standard AS 4050(Int)-1992, 'Fire Detection and Alarm Systems, Firefighters' Control and Indicating Facilities'. Listing is subject to ActivFire Scheme terms and conditions as applicable to the designated registrant and supplier. This product listing data sheet should be read in conjunction with the general requirements of the terms and conditions of listing under the ActivFire Scheme. CSIRO Australia, 2007 Executive Officer

afp - 1421 Registration:... 17-May-2001 Page 2 of 6 Limitations/conditions of conformance Limitations/conditions of conformance, where identified on this Product Listing Data Sheet, are derived from qualifications within the report of the testing agency and/or other related technical documentation. It is recommended that all details with respect to design, assembly and installation restrictions should be checked against the designated supplier's/manufacturer's current technical manual/data sheets and the requirements of the Authority having Jurisdiction. Compatibility of the Simplex, Model F3200, fire indicator panel with detectors and base assemblies should be confirmed prior to installation. Technical specification The following details are a representative extract of the technical specification for the Simplex, Model F3200, fire indicator panel and may be subject to change. Complete and current details should be determined from the designated supplier's/manufacturer's technical manual/data sheets. Mains Supply: 240 Vac +6% -10% 0.5 A 50Hz System Power Supply: 3.0 A @ nominal 27.3Vdc @ 20 C Temperature Compensation: -36mV per C nominal Environmental: -5 to 45 C (Ambient) RH 95% maximum @ 40 C (non-condensing) Part Number Details: AS 1603:Part 4 AS 4428:Part 1 Description FP0550 FP0780 FIP, 24Z max, 3A PSU, no cardframe FP0551 FP0781 FIP, 64Z max, 3A PSU, cardframe fitted FP0583 FIP, 24Z max, 3A PSU, small cabinet FP0712 FP0782 FIP, 24Z max, 6A PSU, no cardframe FP0713 FP0783 FIP, 64Z max, 6A PSU, cardframe fitted FP0784 FIP, 8Z max, 3A PSU, small cabinet FP0553 FP0553 8 zone input expansion kit FP0554 FP0554 8 relay expansion kit FP0714 FP0791 Network Display Unit (NDU), slimline FP0715 FP0790 Network Display Unit (NDU), c/w MAF/PSU FP0704 FP0795 Network Upgrade Kit, RS485 FP0771 FP0771 Network Upgrade Kit, I-Hub FP0773 FP0792 Network Display Unit (NDU), slimline, flush mount FP0774 FP0791 Network Display Unit (NDU), slimline, surface mount FP0793 Network Display Unit (NDU), slimline, deep FP0733 FP0794 Network Display Unit (NDU), slimline, 4U 19" rack module Current demands: Module Quiescent Alarm FP0550 130 ma 275 ma FP0551 130 ma 275 ma FP0583 130 ma 275 ma AZC 10 ma 27 ma LCD Backlight Off - 19 ma On - 75 ma

afp - 1421 Registration:... 17-May-2001 Page 3 of 6 Tested Modules: Module Description 8 Zone Module PA 0492 MAF/PSU (AS 1603.4) PA 0491 MAF/PSU (AS 4428.1) PA 0809 Controller Board (AS 1603.4) PA 0797 8 Relay Module PA 0493 Display Board PA 0454 PA 0741 RS485 comms PA 0773 Relay Driver Module PA 0461 Controller (AS 4428.1) PA 0870 MAF/PSU (AS 4428.1) PA 0873 I-Hub Network Interface PA 0839 Fibre-Optic Modem OSD 139 RS232 Modem Supplementary information Assembly Number Rev. PCB Number Iss. Circuit Diagram Iss. 1931-4 A/2 1931-4 A 1931-4 2 1931-3-1 D/9 1931-3 D 1931-3 9 1931-3-2 D/9 1931-3 D 1931-3 9 1931-84 C/5 1931-84 C 1931-84 5 1931-5 A/2 1931-5 A 1931-5 2 1901-25-1 C/3 1901-25 C 1901-25-1 3 1901-25-5 C/2 1901-25 C 1901-25-5 2 1901-139-3 C/4 1901-139 C 1901-139-3 4 1901-25-2 C/2 1901-25 C 1901-25-2 2 1931-111-1 B/2 1931-111 B 1931-111 2 1931-3-3 D/9 1931-3-3 D 1931-3 9 ECM9603 B/3 ECM9603 B ECM9603 3 Eproms: Ver-2.09 Ver-2.06 Ver-3.00 Manuals: Issue Date Standard $16B7 A$A822 AS 4428 $6B72 Technical manual 2.7 SF0229 SF0221 LT0121 Network $16BB SF0230 A$A826 AS4428 Network $6B76 SF0222 Operators manuals LT0119 2.04 NDU $16BD SF0231 A$A828 NDU $6B78 SF0224 LT0250 1.00 31/10/2000 Test Reports: XB1209/R2, April 1994, XB1348/R1, June 1994,, XF1054/R1, March 1995, XF1252/R1, April 1998,, XF1364/R1, Feb 1998, XF1450/R1, July 1998,, XF1457/R2, November 1998,, XF1624/R3, February 2000,, XF1722/R1, April 2001, AS 4428:Part 1 Assessment XF1757/R2, May 2001, AS 4428.0-1997 Appendix E, XF1780/R1, July 2001, pren54: Part 10 Assessment XF1875/R1, June 2002, AS 4428.1-1998, XF1910/R1, July 2002, AS 4428.1-1998, XF1930/R1, September 2002, AS 4428.1-1998,

afp - 1421 Registration:... 17-May-2001 Page 4 of 6 s: Supplementary information (continued) Maximum Number of Devices Allowed per 1931-4 AZC Test Report Cerberus, DL01191A, Beam Detector 1 XF1450/R1, July 1998, Apollo, Series 60, P/N 55000-105, Heat Type A 40* XB1209/R2, April 1994, Apollo, Series 60, P/N 55000-106, Heat Type B 40* Apollo, Series 60, P/N 55000-107, Heat Type C 40* " Apollo, Series 60, P/N 55000-108, Heat Type D 40* " Apollo, Series 60, P/N 55000-240, Smoke Ionisation 40* " Apollo, Series 60, P/N 55000-310, Smoke Photoelectric 40* " The above detectors with Apollo P/N 45681-200 base (non - indicating) Flameguard, Mk8, Heat Type A 22 XB1348/R1, June 1994 Flameguard, Mk8, Heat Type C 11 Hochiki, DCA-B-60R, Heat Type A 40* XB1209/R2, April 1994, Hochiki, DCA-B-90R, Heat Type C 40* Hochiki, DCD-A Heat Type A 40* XF1252/R1, February 1998, Hochiki, DCD-C Heat Type C 40* The above detectors with Hochiki YBO-R/4A base Hochiki, DFE-60B, Heat Type B 40* XB1209, April 1994, Hochiki, DFE-90D, Heat Type D 40* Hochiki, DFJ-60B, Heat Type B 40* XF1252/R1, February 1998, Hochiki, DFJ-90D, Heat Type D 40* The above detectors with Hochiki YBO-R/4A base Hochiki, HF-24A Mk 1, Flame 18 XB1209/R2, April 1994, Hochiki, SIF-AM Mk 1, Smoke Ionisation 40* Hochiki, SIH-AM, Smoke Ionisation 40* Hochiki, SIJ-ASN, Smoke Photoelectric with Hochiki YBO-R/4A base 40* XF1252/R1, February 1998, Hochiki, SLG-AM Mk 1, Smoke Photoelectric 40* XB1209/R2, April 1994, Hochiki, SLK-A, Smoke Photoelectric 40* Hochiki, SLR-AS Smoke Photoelectricwith Hochiki YBO-R/4A base 40* XF1252/R1, February 1998, Minerva, MD614, Heat Type A 40* XF1624/R3, February 2000 Minerva, MD614, Heat Type C 40* Minerva, MF614, Smoke Ionisation 40* " Minerva, MR614, Smoke Photoelectric 40* " Minerva, MR614T, Smoke Photoelectric 40* " Minerva, MU614, Carbon Monoxide 40* " The above detectors with Minerva M614 base * Maximum number of detectors allowed by code

afp - 1421 Registration:... 17-May-2001 Page 5 of 6 s (continued): Supplementary information (continued) Maximum Number of Devices Allowed per 1931-4 AZC Test Report Olsen, B111B, Beam Type Smoke 40* XB1209/R2, April 1994, Olsen, B21B, Beam Type Smoke 1 Olsen, C23B, Smoke Ionisation 40* XB1209/R2, April 1994, Olsen, C23BEx, Smoke Ionisation (intrinsically safe) 40* Olsen, C24B, Smoke Ionisation with Olsen Z54B/Z56 base 40* XB1209/R2, April 1994, Olsen, C24B, Smoke Ionisation with Olsen Z500 base & optionally E500 Mk2 remote indicator Olsen, C29B, Smoke Ionisation with Olsen Z54B/Z56 base 40* XB1209/R2, April 1994, Olsen, C29B, Smoke Ionisation with Olsen Z500 base & optionally E500 Mk2 remote indicator Olsen, C29BEx, Smoke Ionisation with Olsen Z94C base and intrinsically safe barrier (KHD0-ICS/EX251) with ZAU 401 40* XF1054/R1, March 1995, zone adaptor Olsen, C29BEx, Smoke Ionisation with Olsen Z94C base 40* " and intrinsically safe barrier (KHD0-ICS/EX151) with ZAU 401 zone adaptor Olsen, C29BEx, Smoke Ionisation with Olsen Z94C base 40* " and intrinsically safe barrier (KHD3-ICR/EX 130-200) Olsen, FW81B, Heat Type E 1000m XB1209/R2, April 1994, Olsen, P136, Duct Sampling Unit 8 XF1930/R1, September 2002, AS 4428.1-1998 Olsen, P24B, Smoke Photoelectric with Olsen Z54B/Z56 base 40* XB1209/R2, April 1994, Olsen, P24B, Smoke Photoelectric with Olsen Z500 base & optionally E500 Mk2 remote indicator XF1457/R2, November 1998 Olsen, P29B, Smoke Photoelectric with Olsen Z54B/Z56 base 36 XB1209/R2, April 1994, Olsen, P29B, Smoke Photoelectric with Olsen Z500 base & optionally E500 Mk2 remote indicator Olsen, P61B (Rev J) Smoke Photoelectric 40* XB1209/R2, April 1994, Olsen, P76B, Smoke Photoelectric Non-latching 10 Olsen, R23B, (LED version only) Flame 36 " Olsen, R24B, Flame 8 " Olsen, R24BEx, Flame (intrinsically safe) 8 " Olsen, T54B, Heat Type E 40* " Olsen, T56B Mk V, Heat Type A, B, C & D with Olsen 40* XB1209/R2, April 1994, Z54B/Z56 base Olsen, T56B Mk V, Heat Type A, B, C & D with Olsen Z500 base & optionally E500 Mk2 remote indicator Olsen, V41B/V42B Flame 40* " Olsen, V44B Flame 40* " * Maximum number of detectors allowed by code Detector must be powered from 24 Vdc supply that must be provided with transient protection, a fuse and a re-setting facility

afp - 1421 Registration:... 17-May-2001 Page 6 of 6 s (continued): Supplementary information (continued) Maximum Number of Devices Allowed per 1931-4 AZC Test Report Simplex, 4098-9618EA, Heat Type A 40* XF1757/R2, May 2001 Simplex, 4098-9619EA, Heat Type B 40* Simplex, 4098-9621EA, Heat Type D 40* " Simplex, 4098-9601EA, Smoke Photoelectric 40* " Simplex, 4098-9603EA, Smoke Ionisation 40* " The above detectors with Simplex 4098-9788EA base Thorn, S111, Flame 40* XB1209/R2, April 1994, Thorn, S121, Flame 40* Thorn, S131, Flame 40* " Thorn, S231f+, infra-red flame and Isolating Barrier KFD2-CR-EX1.30 200 repeater (Note 1) 11 XF1875/R1, June 2002, AS 4428.1-1998 Thorn, S231i+, infra-red flame and Isolating Barrier 11 KFD2-CR-EX1.30 200 repeater (Note 1) Thorn, S261f+, infra-red flame 40* XF1780/R1, June 2001 Tyco, SU0600, Manual Call Point 40* XF1875/R1, June 2002, AS 4428.1-1998 Tyco, T614A, Heat Type A 40* XF1910/R1, July 2002, Tyco, T614B, Heat Type B 40* AS 4428.1-1998 Tyco, T614C, Heat Type C 40* Tyco, T614D. Heat Type D 40* " The above heat detectors with Minerva MUB/M614 Universal non-indicating base Note 1: Refer instruction manual for details. Olsen, C29BEx Smoke Ionisation with Olsen Z52, Z55B, Z56B, Z56N and Z500 non-indicating base Max. number of devices allowed per AZF (Mode 1) with KFD0-CS-EX1.51 or KFD0-CS-EX2.51P ISB Test report 40* XF1875/R1, June 2002, AS 4428.1-1998 Short Circuit Device 40* XF1930/R1, September 2002, AS 4428.1-1998 * Maximum number of detectors allowed by code