INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

Similar documents
A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

HV2R ROTARY LASER INSTRUCTION MANUAL

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

H1R Red Rotary Laser INSTRUCTION MANUAL

Instruction manual EN

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

LD200 / RLD400 LD200-G /RLD400-G

Machine Mountable 360º Detector Model No C & M Instruction Manual

Operator's Manual. LIGHTNING 2 Laser Detector

TECHNICAL FILE LEVELS AND MULTI-FUNCTION DETECTORS

VISION H. Instruction manual

IRT2 Dual Laser IR Thermometer - User Guide

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

USER MANUAL MINITRACER PORTABLE SNIFFER

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Motorised Infrared Optical Beam Smoke Detector. User Guide

RT User Guide. Self-leveling, remote-controlled, simultaneous level and plumb rotational laser system

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

TECHNICAL INFORMATION Super Scanner V Metal Detector Catalog No. MDWAND

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

Instruction Manual. Self-Leveling Laser Level Model No

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

FEATURES ON/OFF Button Pinpointing Tip 360 Side-Scan Area Exclusive Scraping Blade LED Flashlight Speaker Lanyard Attachment Loop Sealed Battery

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

HAND HELD METAL DETECTOR

Refrigerant Leak Detector

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Sensistor XRS9012. Maintenance manual. Hy d r o g e n Leak Det e c t o r

2G & 3G GSM Wireless Beam Alarm

Constant voltage 3-phase rectifier.

Laser Collimated Beam Sensor

ML1 MULTI-LINE LASER INSTRUCTION MANUAL

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

MicrOTDR. Optical Fault Locator. User Manual

High Temperature InfraRed Thermometer with Laser Pointer

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Manual PCE-889 pyrometer

onlinecomponents.com

USER GUIDE Heat Index Psychrometer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

Wet Bulb Thermo-Hygrometer Datalogger

GAS DETECTORS EXPLOSIMETERS/CATHAROMETERS EX 2000/EX 2000 C/GD 2000/GDP Your environment, your safety, let s master them together

Multi Line Laser Level Model: L203

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Counting Scales. HC-i Series.

EST User Manual. (Please read this manual carefully before using)

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

R2310. Infrared Thermometer. Instruction Manual

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

HIn3550 Magnetic Field Monitor User's Manual

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

ENGLISH (Original instructions) Job Site Radio DMR107. INSTRUCTION MANUAL IMPORTANT: Read Before Using.

OPERATION MANUAL. Move it. Hang it. Rack it. Stack it. MaxPower Corporation 230 Yuma Street Denver, CO

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

NEW Restek Electronic Leak Detector

VASTHI ENGINEERS. Vasthi Explosive Meter Sheet No. 1 of 5. Vasthi Monitors for Combustible Gas.

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

Operating Guide. English Version 3.3

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

1000 COSE UTILE PER LA TUA PROFESSIONE

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

User Manual for ULTRASCAN High Pressure Leak and Corona Discharge Detector

Famous Trails Anaheim, California

WASTEWATER Online UV%Transmission Analyzer

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

TM-802 Formaldehyde Meter User s Manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

RAM GENE / RAM GENE-1

I/R Thermometer Gun 12:1

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Adtemp TM V 418N Digital Fever Thermometer USE, CARE & MAINTENANCE

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

Transcription:

INSTRUCTION MANUAL ROTARY LASER LEVEL GPR-R40H / G40

To help you use this instrument conveniently, we provide a specific operation manual for you. Please read the manual carefully before you use the instrument and keep it well. FOR YOUR RECORD Place Of Purchase :... Date Of Purchase :.../.../...

Contents 1. Main body... - 2-2. Directions... - 4-3. Recharge battery... - 6-4. Accuracy Checking... - 7-5. Specifications... - 9-6. Detector... - 10-7. Remote... 錯誤! 尚未定義書籤 - 1 -

1. Main body Laser head Laser window Panel Plug hole Handle - 2 -

1.1 Operation instrument 1.1.1 Auto/manual: Push button to switch manual(remote)or auto leveling. 1.1.2 Power(ON/OFF): Controlling the state of power. 1.1.3 Anti-drift: The Anti-Drift System, when ON, will signal to the operator that the instrument has been moved out of level. 1 2 3 The ADS LED will blink slowly when instrument in Anti-Drift System. The ADS LED will blink quickly when instrument moved out of level. - 3 -

2. Directions 2.1. Battery Installment (1) Take down the cover of battery case at the bottom of the instrument. (2) Put the batteries into the case according to the right position. (3) Lay the cover on the box, and then tighten all screws. 2.2 Instrument Placement Lay the instrument on the tripod or stable flat surface, or even hang it on the wall. Set up right the instrument, and keep the slope of instrument within the range from -5 to +5. 2.3 Operations 2.3.1 Power (1) Press the key ON/OFF to bring automatic leveling into function when the - 4 -

power indicator lights. (2) When power indicator blink, it shows the voltage of the batteries is insufficient. Then the rechargeable batteries need to be charged. (3) Press the Key ON/OFF to close down the instrument. 2.3.2 Leveling (1) When turned on, the laser beam will start to blink, It will stop winking after finish leveling. (2) If the instrument is placed improperly, or the slope of instrument exceeds the range from -5 to +5, the mode indicator and the laser beam will wink at the same time. Then place the instrument properly. - 5 -

3. Recharge battery (1) When the batteries needs to be charged, connecting the charger with AC. Insert the plug of charger into the plug hole at the bottom of the instrument (As depicted below). (2) If the indicator of charger lights, it shows the batteries are being charged. (3) If the indicator light of the charger winks, it shows the course of recharging has ended. Plug hole Charger Notices: 1. Using the standard rechargeable batteries of the instrument, recharging will be - 6 -

finished within 7 hours. 2. Power required for the charger: Frequency: 50-60HZ; Voltage: 85-265V. 3. Charging and using of the instrument can progress simultaneously. 4. If keeping the instrument in storage (or Leave the instrument unused for a long time), the batteries (dry battery or rechargeable battery) needs to be taken out. 5. Brand-new rechargeable batteries or long-time unused rechargeable batteries need to be recharged and discharged three times to attain the capacity required. 4. Accuracy Checking 4.1 Horizontal-surface Checking (1) Place the instrument at the point of 50m in front of wall (or set a scale plate at the point of 50m away from the instrument), and then adjust the level of the - 7 -

base approximately to aim the X1 to the wall (or scale plate), as depicted below: (2) After switching on the power, use the laser detector measuring the h1 of X1-beam on the wall or scale plate. (3) Loose the screw of the tripod, and then turn around the instrument 180 to measure the h2 of X2-beam on the wall or scale plate. D-value between h1 and h2 ought to be less than 10mm (4) Check the Y-beam in the same way. X1 X1-beam X2-beam H1 H2-8 - Approximately

5. Specifications Model no. GPR-R60H GPR-G60 Light source Red beam-high power Green beam laser diode, wavelength 635nm Leveling accuracy ±10 / ±20 Self-leveling range ±5 Measuring range Diameter: 500m (Using the laser detector) Spinning speed 0,60,120,300,600 r.p.m. Directional-scanning - Setting slope ±5 (Dual axis) Down point Accuracy:±1mm/1.5m Remote controlling Distance Approximately 20m Power Supply DC 4.8-6V (NI-MH rechargeable) Working Temperature -20 C~+50 C (-4 F~+122 F) Water-proof IP-56 Dimension 170(L)x170(W)x190(H)mm Weight 2.6kg - 9 -

6. Detector The Universal Laser Detector aids in locating and targeting a visible or invisible beam emitted by a rotary laser; perfect for use in outdoor conditions, where sunlight and distance may make locating the beam more difficult. The laser detector includes a rod clamp which allows to mount the detector onto square, round or oval sighting rods. LCD readout window Beam capture High/Low sensor Volume ON/OFF Speaker Power ON/OFF - 10 -

6.1 Operation instrument (1) Mount the instrument onto a sighting rod if you are using one. Turn on the instrument by pressing the ON/OFF pad. The LCD symbols will momentarily flash and the coarse beam indicator symbol will remain lit and the audio signal will be on. (2) Expose the beam capture window of the laser detector towards the direction of the rotating laser. (3) Slowly move the laser detector in an upward and downward direction until the LCD beam indicator arrows appear and/or a pulsing audio signal is heard. Use the Beam Resolution feature to choose between the coarse/low setting, used for approximating level or for initial locating of the center level point, the medium setting, used for greater accuracy, and the fine/high setting, used for - 11 -

the most accurate pinpointing of level. (to see the available Resolutions, please refer to the Specs Table). (4) Move the detector upward when the low beam indicator light is lit (with volume on, a short pulsing audio tone is heard). Move the detector downward when the high beam indicator arrow is lit (with volume on, a long pulsing audio tone is heard). When the beam is level, the level beam indicator line will be lit and a solid audio tone will be heard. (5) If the detector is not struck by a laser beam after 5-8 minutes, the detector will automatically shut itself off to preserve battery life. Turn the instrument back on using the power button. - 12 -

Memo

Memo

Memo

Giant Precision Instrument Co., Ltd. No.16, Ln. 134, Liancheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) Zip:23553 Tel: 886-2-2246-7302 Fax: 886-2-2246-7301