OPERATING MANUAL. ba75825e03 12/2015 LR 925/01 LR 925/01-P LR 925/01(-P) ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

Similar documents
CH cleaning head Sensor cleaning accessory operated by compressed air

ViscoClock plus AUTOMATIC VISCOSITY MEASUREMENT EASY AND PRECISE

Lenntech. Tel Fax bar. Multistage Pumps.

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Figure 1 DirectLine DL423 Sensor. Description, continued

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

Sealless Immersion Pumps for Industrial Applications

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Conductivity Electrode LRG Original Installation Instructions English

Advance Optima Module Magnos 17

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

Flygt 3153, 3171, 3202, 3301, 3315, 5100, Replacing Cooling Liquid In Pumps with Cooling Jackets

Product waste disposal - Protection of the environment:

Figure 1 DirectLine DL423 Sensor. Description, continued

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

Visit us at

Toroidal Conductivity Transmitters Series APT4000 Specifications

testo 270 Deep-frying Oil Tester

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

BAMOSOFT Control. Water hardness monitor INSTRUCTIONS MANUAL DUR. BAMOSOFT Control. Water hardness monitor / M1 01 C

Vacuum Controller with Control Unit VC 900

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

Multi-Mode Electrode pro

Spandau Pumps. Sealless Immersion Pumps for Industrial Applications. Overwiev of Products

IC Professional Detector

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Twin radial blower DRG 1200

Ecocirc D5vario DC pumps DIRECT OR BATTERY POWERED FROM 8-24 VOLT, WITH SPEED CONTROL

OILTESTER - Deep-frying Oil Tester. Instruction manual

Twin radial blower DRG 1200 with oval resistor, 12 and 24 Volt versions

Operating Instructions

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

MEAS CAL ALARM WASH CONF APT4000 TC

optris Outdoor protective housing

Digital Heat Block User Manual

Twin radial blower DRG 730

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

GENYO Series ELECTRIC PUMP CONTROL AND PROTECTION SYSTEM

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

SECTION Free/Available Chlorine Analysis System

Operating Instructions

Inductive Conductivity

Lowara ecocirc and ecocirc PREMIUM THE NEW HIGHLY EFFICIENT CIRCULATORS WITH THE PATENTED ANTI-BLOCK-TECHNOLOGY

ACQUITY UPLC HT Column Heater Instructions

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

NEW Lowara ecocirc PRO The new high efficiency domestic hot water PumPs with automatic air venting function and TheRmaL insulation shell

Beck. The differential pressure transmitter for air

Aluminum Heating Mantles

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

Concise catalogue Water-Industry

Mounting and Operating Instructions EB 2231 EN

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Service: to SLK Laboratory Hot Plates glass made of ideas

OILTESTER Deep-frying Oil Tester. Instruction manual

testo 316-EX gas leak detector Instruction manual

The GAK-800 Heated Exercise Gas Analyzer Accessory Kit

Retractable ph/orp Sensor

Mechanical seals external, single or double, to DIN EN 12756

DATA SHEET CS8100 CS8100_IT_EN_DS049REV02_IS

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD ARJONS DR., SUITE C P.O. BOX LINKOU-117

FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

ph Measuring System Start-up and maintenance manual e Contents

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Silicon Pyranometer GSM xx

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

Wind Alarm Instrument

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

+ English + 1. Safety warnings

IntelliDoX Operator Manual

Quick Start Guide LIQ-QSG-Hx338, Rev M July Rosemount Hx338. Steam Sterilizable and Autoclavable ph Sensor

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

CryoFit. Handling of Flow Cell and Capillaries. User Guide. Version 002

Service Manual - Series 450/451 IG IGV IG IGV IG IG IG IGV IG

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

INSTRUCTIONS CertoClav EL

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Measurement Solutions for Refrigeration Technology.

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

WEDECO Quadron UV System

SCHMIDT LED Measured Value Display MD Instructions for Use

More Precision. indusensor // Linear inductive displacement sensors

APT2000 Series 2-Wire Contacting Conductivity Transmitters User Manual MU1I-6246 Revision 1 01/00

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Polar H7 Heart Rate Sensor. User Manual

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

testo 550 Digital manifold Instruction manual

More Precision. indusensor Linear inductive displacement sensors

Flygt Top-Entry Agitators CONVENIENT AND EFFICIENT

Certificate: _01 / 22 March 2013

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Transcription:

OPERATING MANUAL ba75825e03 12/2015 LR 925/01 LR 925/01-P ULTRAPURE WATER CONDUCTIVITY MEASURING CELL

Copyright 2016 Xylem Analytics Germany GmbH Printed in Germany.

Contents - Contents 1 Overview......................................... 4 1.1 Structure and function................................ 4 1.2 Recommended fields of application..................... 4 2 Measurement / Operation............................ 5 2.1 Commissioning..................................... 5 2.2 Opening and closing the IDS plug connection (LR 925/01-P).. 6 3 Cleaning.......................................... 7 4 What to do if....................................... 8 5 Technical data..................................... 9 5.1 General data....................................... 9 5.2 Measuring ranges and resolution...................... 11 5.3 Accuracy of the IDS measuring technique............... 11 6 Wear parts and accessories......................... 12 ba75825e03 12/2015 3

Overview OPERATING MANUAL 1 Overview 1.1 Structure and function Structure LR 925/01 4 LR 925/01-P 1 2 3 1 Shaft 2 Connecting head with active sensor electronics 3 IDS plug (LR 925/01-P) 4 Connection cable (LR 925/01) Automatic sensor recognition The sensor electronics with the stored sensor data is in the connecting head. The data include, among other things, the sensor type and series number. With each calibration, the calibration data is written in the sensor and the calibration history is recorded. The data is recalled by the meter when the sensor is connected and is used for measurement and for measured value documentation. Storing the calibration data in the sensor ensures that the correct cell constant is automatically used if the sensor is operated with several meters. The digital transmission technique guarantees the failure-free communication with the meter even with long connection cables. If the sensor firmware is enhanced by WTW, it can be updated with the meter. 1.2 Recommended fields of application Measurements in ultrapure water. 4 ba75825e03 12/2015

Measurement / Operation 2 Measurement / Operation 2.1 Commissioning Scope of delivery Conductivity measuring cell Operating manual Preparing the sensor for measurement LR 925/01 LR 925/01-P Connect the sensor to the meter.the sensor is immediately ready to measure. Connect the sensor to an IDS connector of the meter. To open and close the IDS plug connection please follow the section 2.2 OPENING AND CLOSING THE IDS PLUG CONNECTION (LR 925/01-P). The sensor is immediately ready to measure. Connection cables in different lengths to connect the LR 925/01-P sensor to the meter are listed in chapter 6 WEAR PARTS AND ACCESSORIES. ba75825e03 12/2015 5

Measurement / Operation 2.2 Opening and closing the IDS plug connection (LR 925/01-P) This section only applies to the IDS plug variant, LR 925/01-P. Plug connection closed and locked 4 1 3 Guidance 2 Groove Opening the plug connection Closing the plug connection If necessary, clean the plug connection. Open the locking device (step 1). Use your thumb and index finger to press the clips of the connector together, and pull the connector out of the plug (step 2). Make sure that the plug connection is completely dry and clean. Align the guidance of the connector with the groove in the plug and insert the connector in the unlocked plug until it catches (step 3). Close the locking device (step 4). 6 ba75825e03 12/2015

Cleaning 3 Cleaning Note To clean the sensor, disconnect it from the instrument. Exterior cleaning We recommend to clean the sensor thoroughly, especially before measuring low conductivity values. Contamination Lime sediments Fat/oil Cleaning procedure Immerse in acetic acid for 5 minutes (volume share = 10 %) Clean with warm water that contains washing-up liquid After cleaning, thoroughly rinse with deionized water and recalibrate if necessary. Aging of the conductivity measuring cell Disposal Normally, the conductivity measuring cell does not age. Special measuring media (e.g. strong acids and bases, organic solvents) or temperatures that are too high may considerably reduce its lifetime or lead to damage. The warranty does not cover failure caused by measuring conditions and mechanical damage. We recommend to dispose of the measuring cell as electronic waste. ba75825e03 12/2015 7

What to do if... 4 What to do if... Error symptom Cause Remedy No temperature or conductivity display Measurement delivers implausible conductivity values Incorrect temperature display No connection between meter and conductivity measuring cell Cable defective Measuring range exceeded Contamination in the area of the electrodes Electrodes damaged The temperature sensor is not immersed deep enough in the measuring solution Temperature sensor defective Establish connection between meter and conductivity measuring cell Make sure the correct sensor is being used for the application Clean the conductivity measuring cell (see section 3). Return the sensor Observe the minimum immersion depth Return the conductivity measuring cell 8 ba75825e03 12/2015

Technical data 5 Technical data 5.1 General data General features Measuring principle 2-electrodes measurement Cell constant 0.100 cm -1 ± 2 % Temperature sensor Integrated NTC 30 (30 k at 25 C / 77 F) Dimensions (in mm) LR 925/01: 120.0 176.0 LR 925/01-P: 12.0 120.0 222.8 21.7 12.0 21.7 Weight LR 925/01 Approx. 90 g (without cable) LR 925/01-P Approx. 95 g Materials Shaft Stainless steel 1.4571 Connection head LR 925/01: POM LR 925/01-P: POM Conductivity electrodes Stainless steel 1.4571 Thermistor enclosure Stainless steel 1.4571 ba75825e03 12/2015 9

Technical data Connection cable Lengths LR 925/01: 1,5 m LR 925/01-P: 1,5 / 3 / 6 / 10 / 15 / 20 m Diameter Smallest allowed bend radius Plug type 4.3 mm Fixed installation: Flexible use: Socket, 4 pins 20 mm 60 mm IDS plug (LR 925/01-P) Type of connection Materials 4-pole, watertight plug connection with lock, reverse polarity protected Synthetic materials: Glass fiber reinforced Noryl, TPU, TPC-ET, POM, PEEK, PBT O-ring: FPM Contacts gold-plated Pressure resistance Sensor with connection cable Cable plug IP 68 (2 x 10 5 Pa or 2 bar) IP 67 (when plugged in) The meets the requirements according to article 3(3) of the directive, 97/23/EC ("pressure equipment directive"). Measurement conditions Conductivity measuring range Temperature range Max. admissible overpressure Minimum depth of immersion Maximum depth of immersion (at temperature) Operating position 0.01 S/cm... 200 S/cm -5... 70 C (100 C) 23... 158 F (212 F) 2 x 10 5 Pa (2 bar) 30 mm Whole sensor + cable up to 70 C (158 F) Sensor shaft only (=120 mm) up to 100 C (212 F) Any Storage conditions Recommended storing method Storage temperature In air 0... 50 C (32... 122 F) 10 ba75825e03 12/2015

Technical data Characteristics when delivered Temperature responding behavior Accuracy of the temperature sensor t 99 (99 % of the final value display after) <20s ± 0.2 K 5.2 Measuring ranges and resolution Measuring ranges, resolution Measured parameter Measuring range Resolution ӕ [µs/cm] 0.01... 19.99 0.0... 199.9 0.01 0.1 ρ (resistivity) [kohm*cm] 5,00... 19,99 20.0... 199.9 200... 1999 ρ (resistivity) [MOhm*cm] 2.00... 19.99 20.0... 199.9 0.01 0.1 1 0.01 0.1 T [ C] 5,0... + 100,0 0.1 5.3 Accuracy of the IDS measuring technique Measured parameter Accuracy (± 1 digit) ӕ, ρ ± 0.5 % of measured value T [ C] ± 0.1 ba75825e03 12/2015 11

Wear parts and accessories 6 Wear parts and accessories Accessories for LR 925/01-P (IDS plug variant) Description Model Order no. IDS connection cable, 1,5 m AS/IDS-1.5 903 850 IDS connection cable, 3 m AS/IDS-3 903 851 IDS connection cable, 6 m AS/IDS-6 903 852 IDS connection cable, 10 m AS/IDS-10 903 853 IDS connection cable, 15 m AS/IDS-15 903 854 IDS connection cable, 20 m AS/IDS-20 903 855 Blind plug for IDS plug (sensor) BPO/IDS 900 908 371 Blind plug for IDS socket (cable) BPI/IDS 900 908 370 Further accessories are listed in the price list of the WTW catalog "Laboratory and field instrumentation". 12 ba75825e03 12/2015

What can Xylem do for you? We're a global team unified in a common purpose: creating innovative solutions to meet our world's water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com. Service address: Xylem Analytics Germany Sales GmbH & Co. KG WTW Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany Tel.: Fax: E-Mail +49 881 183-325 +49 881 183-414 wtw.rma@xyleminc.com Internet: www.wtw.com Xylem Analytics Germany GmbH Dr.-Karl-Slevogt-Str. 1 82362 Weilheim Germany