FIRE ALARM: BY OTHERS, IF REQUIRED.

Similar documents
FIRE ALARM: BY OTHERS, IF REQUIRED.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings


RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION (16140) - WIRING DEVICES

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Electrical Design Guidelines Table of Contents

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

PANELBOARDS & BUILDING DISTRIBUTION

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST

CHAPTER 20 SERVICE EQUIPMENT

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Allegany College of Maryland ACM Welcome Center M&D Project No

CONTINUING EDUCATION FOR OREGON ELECTRICIANS. AMERICAN ELECTRICAL INSTITUTE PO Box Spokane, WA

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Residential Wiring (2014 NEC) (Homestudy)

Residential Wiring According to 2011 NEC (Homestudy)

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

GARCIA GALUSKA DESOUSA Consulting Engineers

PART GENERAL 1.01 SECTION INCLUDES

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Element D Services Electrical

C. Pigtail: Short lead used to connect a device to a branch-circuit conductor.

2011 and 2014 National Electrical Code Changes Residential Only

Page 1 of General

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

2009 ELECTRICAL CODE REQUIREMENTS

Lord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

Renovate MCRC Facilities Great Lakes, IL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Construction Management at Risk Services. New North East Branch Library Project. August 3, 2018

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

Division 26 ELECTRICAL TABLE OF CONTENTS

DIVISION 16 ELECTRICAL

Residential Wiring (2017 NEC) (Homestudy)

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Spring Test 6 due 04/26/2013

Units 2, 3, 4, 5, 6, 8, 9, 10, Electrical Wiring Residential Unit 2 (Unit 5 Fourth Edition)

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

The following information shall become and form part of the contract documents.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.


DONALD H. BERG, ARCHITECT

SOUTHVIEW MEDICAL CENTER

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

ELECTRICAL DESIGN BRIEF

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

BASIC ELECTRICAL ENGINEERING FOR CE

Instructor: L. Keith Lofland

Library stacks and records storage 150 LB/SF live load

SECTION ISOLATED POWER SYSTEMS

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

Photovoltaic (Solar) Array Installation Guide

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

SECTION ELECTRICAL IDENTIFICATION

Understanding Your Options: AFCI Protection and the 2015 CE Code

TOM BURNS, PLANNING DIRECTOR

SECTION LOW VOLTAGE LIGHTING CONTROLS

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

Chapter 1 General... 5

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

NEC Study Guide CORRECT: C NEC (A)(1)

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

A. This Section includes the following lighting control devices:

Appendix B. Facilities Assessment Report

SECTION LIGHTING

SECTION FIRE ALARM SYSTEMS

13. ELECTRICAL - TECHNICAL

DIVISION SECTION ELECTRICAL. A. Provisions of General Requirements, Division 1, are a part of this section.

ELECTRICAL DESIGN GUIDELINES SECTION GUIDELINE SPECIFICATIONS-DUVAL COUNTY PUBLIC SCHOOL

District 1. 1 Tony Tadysak Craig Mulder

Transcription:

x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE. WALL MTD. LIGHT FIXTURE, IE. WALL PACK, SCONCE, CYLINDER, ETC. CEILING MTD. LIGHT FIXTURE, IE. GLOBE, DOWNLIGHT, PENDANT, ETC. SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. SPOT LIGHT CAPITAL LETTER DENOTES TYPE. BOLLARD, CAPITAL LETTER DENOTES TYPE. POLE LIGHT, SEE LIGHT FIXTURE SCHEDULE AND DETAILS FOR POLE SPECIFICATION. CAPITAL LETTER DENOTES TYPE. TRACK HEAD CAPITAL LETTER DENOTES TYPE. FLUORESCENT LIGHT FIXTURE WITH EM BALLAST, EM BALLAST TO PROVIDE 1000 LUMENS MINIMUM. EMERGENCY LIGHT FIXTURE, IE FROGEYE, ALL EMERGENCY LIGHTS TO HAVE 1HR MINIMUM BATTERY BACKUP. EXIT SIGN, ALL EXITS LIGHTS TO HAVE 1HR MINIMUM BATTERY BACKUP. SHADING INDICATES ILLUMINATED FACE, PROVIDE CHEVRONS AS INDICATED. MOUNT 7'6" TO BOTTOM OF FIXTURE ABOVE FINISHED FLOOR. TOGGLE SWITCH, 20A, SINGLE POLE, VOLTAGE AS REQUIRED. MOUNT 48" AFF. 3-WAY, TOGGLE SWITCH, 20A, SINGLE POLE, VOLTAGE AS REQUIRED. MOUNT 48" AFF. 4-WAY, TOGGLE SWITCH, 20A, SINGLE POLE, VOLTAGE AS REQUIRED. MOUNT 48" AFF. ROCKER SWITCH WITH DIMMER ADJUSTABLE SLIDE, SINGLE POLE SWITCH, 1000W, 120V, UNO., MOUNT 48" AFF. 0-10V. DUAL TECH OCCUPANCY SENSOR, WALL MTD., 48" AFF. PROVIDE 0-10V DIMMING ADJUSTABLE SLIDE. DUAL TECH OCCUPANCY SENSOR, WALL MTD., 48" AFF. PROVIDE 0-10V DIMMING ADJUSTABLE SLIDE. DUAL TECH OCCUPANCY SENSOR, CEILING MTD. DUAL TECH OCCUPANCY SENSOR, WALL MTD. PHOTOCELL SWITCH, MOUNT ON FACING EXTERIOR WALL, UNO. POWER S DUPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO. SUBSCRIPT DENOTES TYPE. IE. IG=ISOLATED GROUND, GFI=GFCI, WP=WEATHERPROOF QUAD RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO. SUBSCRIPT DENOTES TYPE. IE. IG=ISOLATED GROUND, GFI=GFCI, WP=WEATHERPROOF SIMPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO. SUBSCRIPT 'C' DENOTES CLOCK RECEPTACLE, MOUNT AT HEIGHT DIRECTED ARCHITECT. SPECIAL RECEPTACLE, 220V, TYPE AS INDICATED OR MATCH EQUIPMENT CAP. MOUNT AT HEIGHT AS REQUIRED PER EQUIPMENT. DUPLEX RECEPTACLE, 20A, 120V, 3 WIRE GROUNDED, NEMA 5-20R, UNO. WITH TIE-BAR REMOVED FOR SWITCHING. SPECIAL PURPOSE RECEPTACLE, NEMA TYPE AS INDICATED. MOUNT AT HEIGHT AS REQUIRED PER EQUIPMENT. PLUGMOLD, MULTI-OUTLET RACEWAY, RECEPTACLES SPACED 12" OC, UNO. MOUNT ABOVE COUNTER. MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PUSHBUTTON OPERATOR. CEILING MTD. SPEAKER WALL MTD. SPEAKER NURSE/EMERGENCY CALL BUTTON NURSE CALL LIGHT KRONUS TIME CLOCK ADT TOUCH PAD PUSH BUTTON DOOR BELL TRANSFOMER TELEPHONE OUTLET. WIRING OTHERS, UNO. TELEPHONE OUTLET. WIRING OTHERS, UNO. WALL PHONE, MOUNT 48" AFF. DATA OUTLET. WIRING OTHERS, UNO. DATA/TELEPHONE OUTLET, WIRING OTHERS UNO. CATV OUTLET, WIRING OTHERS, UNO. CIRCUIT RUN, #12W, 1/2" CONDUIT UNO. HOMERUN, #12W, 1/2" CONDUIT UNO., ARROWS INDICATE QUANTITY. CIRCUIT RUN, UNDER FLOOR OR GROUND, #12W, 1/2" CONDUIT UNO. BRANCH CIRCUIT WITH REQUIRED EQUIPMENT CONNECTION. BRANCH CIRCUIT BREAK HORN ONLY HORN AND STROBE STROBE ONLY MANUAL PULL STATION SMOKE DETECTOR HEAT DETECTOR DUCT SMOKE DETECTOR MAGNETIC DOOR HOLD OPEN FIRE/ SMOKE DAMPER FIRE ALARM CONTROL PANEL ANNUNCIATION PANEL SPECIAL SYSTEM S COMMUNICATION SYSTEM S CIRCUITING SYSTEM S FIRE ALARM S ONE-LINE S CIRCUIT BREAKER, FRAME AND TRIP AS INDICATED. POWER TRANSFORMER, RATING AS INDICATED. GENERAL: THESE DRAWINGS REMAIN THE SOLE PROPERTY OF MCSHEA CONSULTING AND MAY BE USED ONLY FOR THE PROJECT AS INDICATED NAME AND LOCATION. ANY OTHER USE REQUIRES PRIOR, WRITTEN PERMISSION. THE CONTRACTOR WILL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, TOOLS, TRANSPORTATION, LICENSES, FEES, PERMITS, ETC. TO COMPLETE THE WORK DESCRIBED ON THE DRAWINGS. THE CONTRACTOR WILL WARRANT EQUIPMENT, MATERIAL AND WORKMANSHIP FOR A MINIMUM PERIOD OF ONE YEAR FROM THE OF ACCEPTANCE. WARRANTY SHALL INCLUDE REPLACEMENTS OR REPAIRS WITHOUT COST TO THE OWNER DURING THE WARRANTY PERIOD. WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL CODE (NEC) 2014 AND ALL OTHER APPLICABLE LOCAL CODES AND ORDINANCES. ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS. USE OF DRAWINGS: DO NOT SCALE FROM THE DRAWINGS. FOR EXACT LOCATIONS USE ARCHITECT'S DIMENSIONED DRAWINGS, SHOP DRAWINGS AND FIELD MEASUREMENTS. VERIFY ALL LOCATIONS WITH THE ARCHITECT PRIOR TO ROUGH-IN. WIRING: ALL WIRING FOR LIGHTING AND POWER SYSTEMS WILL BE IN CONDUIT OR CABLE ASSEMBLIES APPROVED THE GOVERNING AUTHORITIES. CONDUCTOR SIZES SHOWN ARE BASED ON AMPACITIES FOR COPPER CONDUCTORS, UNLESS OTHERWISE NOTED. WHEN APPROVED ENGINEER, FEEDERS MAY BE ALUMINUM CONDUCTORS OF EQUIVALENT AMPACITIES. GROUNDING CONDUCTORS SHALL BE PROVIDED FOR ALL CIRCUITS SHOWN ON THE DRAWINGS. PROVIDE BLOCKING AND OTHER NECESSARY SUPPORTS IN WALLS AND CEILINGS FOR MATERIAL AND EQUIPMENT TO BE PROVIDED. BRANCH CIRCUIT NUMBERS SHOWN ON THE DRAWINGS MAY BE REARRANGED WITHIN A GIVEN PANELBOARD TO SUIT THE NEEDS OF THE INSTALLATION. BRANCH CIRCUITS SHALL BE BALANCED BETWEEN LINES AND PHASES. UTILITY COORDINATION: PROVIDE ALL COORDINATION WITH THE UTILITY INCLUDING LOAD DATA FORMS AND APPLICATION FOR SERVICE AS APPLICABLE. INSTALLATION OF SERVICE, PRIMARY OR SECONDARY FEEDERS AND METERING SHALL BE PERFORMED IN ACCORDANCE WITH THE UTILITIY REQUIREMENTS. GROUNDING: PROVIDE A COMPLETE GROUNDING SYSTEM AS REQUIRED THE NEC AND LOCAL AUTHORITIES HAVING JURISDICTION. ALL BRANCH CIRCUITS SHALL INCLUDE A GROUND CONDUCTOR. USE OF RACEWAY FOR GROUNDING IS NOT PERMITTED. GALVANIZED GROUND RODS ARE NOT PERMITTED. PANELBOARDS: PROVIDE MINIMUM INTEGRATED EQUIPMENT SHORT CIRCUIT RATING AS INDICATED ON PANEL SCHEDULES. PROVIDE BOLT-ON BREAKERS UNLESS OTHERWISE NOTED. PROVIDE CIRCUIT BREAKERS SHOWN ON THE PANELBOARD SCHEDULES. ALL TERMINATIONS AND LUGS SHALL BE RATED FOR 75-DEGREE CONDUCTORS. PROVIDE TYPEWRITTEN CIRCUIT SCHEDULES TO IDENTIFY PANELBOARD AND EACH BRANCH BREAKER. ACCEPTABLE MANUFACTURERS ARE SQUARE D, SIEMENS AND EATON. WIRING DEVICES: PROVIDE SPECIFICATION GRADE 15 AND 20- AMPERE SWITCH AND RECEPTACLE DEVICES, AS APPLICABLE. OTHER DEVICES SHALL BE PROVIDED AS INDICATED AND SHALL MATCH PLUG-CONNECTED EQUIPMENT FURNISHED FOR THE PROJECT. DEVICE WALL PLATES SHALL BE SMOOTH, NYLON TYPE AND SHALL BE OFFICE WHITE IN COLOR OR AS OTHERWISE SPECIFIED. DEVICE COLOR SHALL MATCH WALL PLATES. DISCONNECT SWITCHES: HEAVY DUTY QUICK-MAKE, QUICK-BREAK TYPE, NON-FUSED UNLESS OTHERWISE NOTED. PROVIDE MEANS TO LOCK SWITCH IN OFF POSITION WITH PAD-LOCK. ENCLOSURES SHALL BE NEMA TYPE 1 OR NEMA TYPE 3R FOR OUTDOOR INSTALLATION. PROVIDE PERMANENT LABELS FOR DISCONNECTS TO INDICATE EQUIMENT SERVED. LIGHTING FIXTURES: SEE LIGHT FIXTURE SCHEDULE. PROVIDE ALL FIXTURES WITH LAMPS AS INDICATED. WHERE REQUIRED, FIXTURES SHALL BE WET OR DAMP LOCATION LABELED. VERIFY MOUNTING HEIGHTS PRIOR TO ROUGH-IN. ALTERNATES NOT ACCEPTABLE UNLESS NOTED AS "OR EQUAL" ON LIGHT FIXTURE SCHEDULE. VOICE/DATA: RACEWAY SYSTEM CONTRACTOR. ALL RACEWAYS SHALL BE PROVIDED WITH PULLSTRINGS OF MINIMUM OF 400-LB. TEST STRENGTH. ALL EQUIPMENT, RECEPTACLES AND CABLING OTHERS. PROVIDE BLANK COVERS OVER ALL UNUSED OUTLETS. CABLES, DEVICES AND CABLE TERMINATION IS OTHERS. FIRE ALARM: OTHERS, IF REQUIRED. CONTRACTOR TO VERIFY CONNECTION TYPE, POWER REQUIREMENTS, MOUNTING HEIGHTS, AND LOCATIONS OF ALL EQUIPMENT WITH TENANT PRIOR TO ROUGH IN. SEE MANUFACTURER'S INSTALLATION MANUALS FOR SPECIFIC DETAILS ON ALL EQUIPMENT. (E) DENOTES DEVICE IS EXISTING. EXISTING DEVICES TO REMAIN ON EXISTING CIRCUIT AND/OR SWITCHES UNLESS SHOWN OTHERWISE. (R) DENOTES DEVICE IS BEING RELOCATED FROM WITHIN EXISTING SPACE AND TO REMAIN ON EXISTING CIRCUIT AND/OR SWITCH UNLESS SHOWN OTHERWISE. INFORMATION ON EXISTING CONDITIONS ARE BASED ON EXISTING PANEL DIRECTORIES, AVAILABLE DRAWINGS FROM LOCAL BUILDING DEPARTMENTS, AND ON SITE VERIFICATIONS WHERE POSSIBLE. CONTRACTOR TO COORDINATE WITH ALL EXISTING CONDITIONS PRIOR TO NEW CONSTRUCTION. NOTIFY ENGINEER OF ALL DISCREPANCIES. NEC ARTICLE 406.11: ALL 125-VOLT 15 AND 20-AMPERE RECEPTACLES IN AREAS SPECIFIED IN 210.52 SHALL BE LISTEDTAMPER-RESISTANT RECEPTACLES. 1512-1528 FLOOR BOX, FLUSH MOUNTED PROVIDE DEVICE, BOX AND COVER AS SPECIFIED. 4"X4" JUNCTION BOX, FLUSH/SURFACE MTD. POWER POLE WITH COMM AND POWER. MOTOR NON FUSIBLE DISCONNECT SWITCH, RATING AS INDICATED. RATING AS INDICATED. GROUND ELECTRODE CURRENT TRANSFORMER (CT) NON-FUSIBLE SWITCH, RATING AS INDICATED. FUSIBLE SWITCH, RATING AND FUSE SIZE AS INDICATED. FEEDER SCHEDULE KEY TAG UTILITY TRANSFORMER NEC ARTICLE 210.12(A): ALL 120-VOLT, SINGLE PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, ROOMS, ROOMS, PARLORS, LIBRARIES, DENS, S, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. SMOKE ALARMS INSTALLED PURSUANT TO SECTION R314.1 OF THE IRC ARE NOT REQUIRED TO BE PROTECTED AN ARC-FAULT CIRCUIT INTERRUPTER. PER IECC 404.1: AT LEAST 50% OF THE LAMPS IN PERMANENT INSTALLED LIGHTING FIXTURES WILL BE HIGH-EFFICACY LAMPS. FUSIBLE DISCONNECT SWITCH, RATING AS INDICATED. UTILITY ELECTRIC METER UNO OC TVSS EWC E H TP SURFACE MTD. PANELBOARD/LOADCENTER. FLUSH MTD. PANELBOARD/LOADCENTER. UNLESS NOTED OTHERWISE. OVER COUNTER, MOUNT RECEPTACLE HORIZONTALLY, 1" ABOVE BACKSPLASH. TRANSIENT VOLTAGE SURGE SUPPRESSOR ELECTRIC WATER COOLER EXISTING DEVICE TO REMAIN. MOUNT DEVICE 6" AFF, HORIZONTALLY. TAMPER-PROOF ABBREVIATIONS MOTOR WITH DISCONNECT MOTOR WITH CONTROLLER AND DISCONNECT GENERATOR TRANSFER SWITCH WEATHERHEAD PANELBOARD OR LOADCENTER, IDENTIFICATION, AMPERES AND VOLTAGE. NOTE: NOT ALL S ARE USED. VERIFY ALL CONNECTIONS AND RECEPTACLE TYPES FOR EQUIPMENT FROM APPROVED MECHANICAL AND EQUIPMENT SUBMITTALS PRIOR TO INSTALLATION. HOMERUNS AND BRANCH WIRING FOR 20 AMP CIRCUITS SHALL BE AS FOLLOWS: LENGTH 1FT TO 50FT 51FT TO 75FT 76FT TO 120FT 121FT TO 190FT 191FT TO 300FT CIRCUIT WIRE SIZE NO.12 AWG NO.12 AWG NO.10 AWG NO.10 AWG NO.10 AWG FIRE ALARM WIRING NOTE: (IF APPLICABLE TO PROJECT) HOMERUN WIRE SIZE NO.12 AWG NO.10 AWG NO.8 AWG NO.6 AWG NO.4 AWG 1. FIRE ALARM INSTALLER TO COORDINATE WITH FIRE MARSHALL ON REQUIRED DOCUMENTATION NEEDED. 2. FIRE ALARM INSTALLER TO VERIFY LOCATION OF FIRE ALARM PANEL. 3. FIRE ALARM INSTALLER TO PROVIDE DUCT SMOKE DETECTORS FOR HVAC UNITS PER SECTION 606 OF THE INTERNATIONAL MECHANICAL CODE. REFER TO MECHANICAL RTU SCHEDULE FOR DETERMINATION OF UNITS TO RECEIVE SMOKE DETECTORS. 1 ONE-LINE DIAGRAM E1.0 NOT TO SCALE PLANS ONE-LINE AND DETAILS E1.0

1 09.05.18 1512-1528 A R C H I T EC T U R E BLDG REVS. PLANS FAULT CURRENT CALCULATIONS E1.1 RAF

1512-1528 UNFINISHED BATH 3 UNFINISHED 1 1ST LEVEL LIGHTING PLAN E2.0 SCALE: 1/4" = 1'-0" LIGHTING PLAN E2.0

OFFICE/ OPT. BEDRM H. BATH OPEN TO BELOW EDGE OF FLOOR ABOVE PWDR OPEN TO BELOW OFFICE/ OPT. BEDRM H. BATH 1512-1528 PWDR 1 2ND LEVEL LIGHTING PLAN E2.1 SCALE: 1/4" = 1'-0" LIGHTING PLAN E2.1

W D W D LAUND. D W D W LAUND. 1512-1528 SITTING SITTING 1 3RD LEVEL LIGHTING PLAN E2.2 SCALE: 1/4" = 1'-0" LIGHTING PLAN E2.2

1512-1528 UNFINISHED BATH 3 UNFINISHED 1 1ST LEVEL POWER PLAN E3.0 SCALE: 1/4" = 1'-0" PLANS POWER PLAN E3.0

EDGE OF FLOOR ABOVE OFFICE/ OPT. BEDRM H. BATH OPEN TO BELOW OPEN TO BELOW OFFICE/ OPT. BEDRM H. BATH 1512-1528 PWDR PWDR 1 2ND LEVEL POWER PLAN E3.1 SCALE: 1/4" = 1'-0" POWER PLAN E3.1

W D W D D LAUND. W D LAUND. W 1512-1528 SITTING SITTING 1 3RD LEVEL POWER PLAN E3.2 SCALE: 1/4" = 1'-0" POWER PLAN E3.2