Welcome. Important Safeguards. Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS:

Similar documents
15,000 BTU Portable Air Conditioner

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Portable Air Conditioner USER MANUAL

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Portable Air-conditioner

Portable Air-conditioner Use and Care Manual

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

PORTABLE AIR CONDITIONER

Portable Air Conditioner. Instruction Manual

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER

Reverse Cycle Portable Air Conditioner with Dehumidifier

Welcome. Safety Instructions

30-pint Dehumidifier User Guide

MODEL: DC10RCDH / DC12RCDH

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

Instruction Manual Item No.: V~, 60Hz

PORTABLE AIR CONDITIONER OWNER S MANUAL

PORTABLE AIR CONDITIONER OWNER S MANUAL

PORTABLE AIR CONDITIONER MODEL NO: AC9000

IMPORTANT SAFETY INSTRUCTIONS

CONTENTS 1 SAFETY INSTRUCTIONS.. 2 FEATURES AND OPERATION... 3 PARTS LIST AND INSTALLATION. 4 CONTROL PANEL AND SETTINGS...

WELCOME IMPORTANT SAFEGUARDS

Portable Air Conditioner User Manual

PORTABLE AIR CONDITIONER (LOCAL)

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Instruction Manual Item No.: V~, 60Hz

Local Air Conditioner

PLEASEREADANDSAVETHESEINSTRUCTIONS. NewAir AC-14000E, AC-14000H Portable Air Conditioner Owner's Manual

Instruction Manual. Portable Air Conditioner

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

PORTABLE AIR CONDITIONER (LOCAL)

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

Moveable Air-conditioner User s Manual

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Dehumidifier. Instruction Manual. Model DH-320/A

Owner s Manual Super-Slim Four-Way Cassette

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Local air conditioner

Portable Air-conditioner Use and Care Manual

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

- Cooling - Heating - Dehumidifying - Fan. Please read this owner s Manual carefully before operating the unit. -1-

LOCAL AIR CONDITIONER

Portable Air Conditioner

KSD-35 DR11 KUE-35 DVN11

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

Dehumidifier. User Manual

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

EVAPORATIVE AIR COOLER SERVICE MANUAL

OPERATING INSTRUCTIONS

PORTABLE AIR CONDITIONER (LOCAL)

Dehumidifier Owner s Manual Read and save these instructions before use

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

AC-12200E Portable Air Conditioner

Dimplex Air Conditioner DAC 12000R

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Arctic EVAPORATIVE COOLER USER MANUAL


Portable Air Conditioner

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

METAL CERAMIC FAN HEATER

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Portable Air Conditioner

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

Operating Instructions

12L Dehumidifier Model: HG00923

Dual-Hose Portable Air Conditioner User Manual

MeacoCool MC Series Portable Air Conditioner

Table of contents. Installing the charcoal filter 18 Cleaning the prefilter 18 Long term storage 18 Troubleshooting 19 Limited warranty 22

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

PORTABLE AIR CONDITIONER (LOCAL)

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Sunleaves Air Conditioner

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

OP40R 40cm Remote Control Pedestal Fan

Portable Air Conditioner User Manual Read and save these instructions before use

PORTABLE AIR CONDITIONER

USER MANUAL PORTABLE AIR-CONDITIONER 2011 FE A4320A BR14081R-1

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

DUE-1237 DEHUMIDIFIER Owner s Manual

5) Do not start or stop the unit by inserting or pulling out the power plug.

FAN HEATER FH118 User Manual

GDDEM10 DEHUMIDIFIER

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

13500 BTU RV Air Conditioner Installation and Operating Instructions

OPERATING INSTRUCTIONS

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Transcription:

Welcome Thank you for purchasing the new Portable Air Condition SY-AC1200. Read this instruction booklet carefully in order to benefit fully from this product. Store the user manual in a safe place for future reference. Important Safeguards Please read the Manual carefully before operating the machine ELECTRICAL CONNECTIONS: Before plugging the appliance into the socket, check that:. The voltage corresponds to the value indicated on the rating plate that is located on the back of the appliance.. The power socket and the electrical circuit are suitable for the device.. The socket matches the plug. If not, have the plug replaced.. The power outlet is properly grounded. Failure to comply with these instructions exempts the manufacturer from all liability. The appliance is for indoor use only. Place the air conditioner on a fat surface and keep it placed vertically to ensure the normal operation of its compressor. This appliance is for domestic use only and not for commercial use. Before inserting, the mains plug into the socket, check that the mains supply voltage and current rating corresponds with the power supply details shown on the rear specification plate of the unit. Read all instructions, Rated Power Supply: Please connect the unit with Grounded Power Source: 220-240VAC, 50HZ. Never share the power outlet with other appliances Never connect or disconnect the power plug with wet hands to avoid electric shocks Disconnect the power plug before dismantling, assembling or before cleaning. Avoid touching mobile parts of the appliance. Never insert fingers, pencils or any other objects though the guard whenever the power plug is connected, especially while running. Persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge do not intend this appliance for use, unless a person responsible for their safety has given them supervision or instruction concerning use of the appliance

The appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the unit safely. Young children should be supervised to ensure that they do not play with the appliance. Do not use the appliance for any other purposes than its intended use. The appliance must not be used if the guards are not fasten according to the instructions. When the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid hazard Do not use your appliance with an extension cord or adapter unless it has been checked and tested by a qualified electrician or electrical supplier In the case of any malfunction, return to an authorized service agent. Never open the unit and try to repair it by yourself. The air conditioner unit must always be stored and transported upright, otherwise you may cause irreparable damage to the compressor; in case of doubt we suggest to wait for at least 24 hours before you start airconditioning unit. Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off, or the compressor may be damaged. Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel. Do not place the Portable Air conditioner next to heat sources or direct sunlight. Always place the portable air conditioner on a dry stable place. Always use the original supplied accessories. Any third party accessory might damage the appliance. The ideal environmental temperature for the portable air conditioner should be 15-35ºC. The appliance shall not be installed in the laundry. The appliance must be positioned so that the plug is accessible and it shall be installed in accordance with national wiring regulations. Clean the portable air conditioner according to the manual reference The tension of the portable air conditioner must meet the requirements. Any damage incurred by an incorrect power source is not included in the warranty. Do not place the portable air conditioner in any place with water or other liquid. Prevent water or any liquid from entering the portable air conditioner. Use the accessories provided by the manufacturer of the portable air conditioner; otherwise, the portable air conditioner may damage. The following ambient temperature is suggested for the portable air conditioner (cooling / heating): 15-35 ºC / 5-27 ºC.

Special warning Place the A/C on even ground and install it vertically so as to ensure normal operation of the compressor. The A/C should be at least 50cm away from surrounding objects. Keep air inlet and outlet smooth. Do not operate the A/C near gasoline or any other inflammable liquid. Do not use spraying agent and other solvent or flammable substances near the A/C; otherwise, its plastic may deform and electric parts may be damaged. Do not expose the unit under direct sun light to avoid surface color fading Do not tilt the unit more than 35 degrees or upside-down while transporting Energy Saving Tips Do not cover or restrict the airflow from the Outlet or Inlet grills. The minimum distance from furniture and wall should be 50CM. Keep the filters clean. Under normal conditions, the filters should be cleaned approximately every 30 days. Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the indoor air quality. Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start-up, then set the fan switch to Low cool and lower the thermostat to a comfortable setting. Suggestions If you want to get better effect, we suggest you not to use cooling function when ambient environment is higher than 35 ºC. Basic functions This unit offers cooling, dehumidifier and fan mode, ideal for home and office use. The unit include 3 fan-speed level accessible by the panel control or the remote control. This unit is designed with various protection functions such as 24 hours programmable timer, auto condensation, intelligent temperature sensor and water control with warning. The ideal temperature for using the portable air conditions is from 15ºC~35ºC.

Parts of the SY-AC1200 1. Top cover 2. Air outlet grille 3. Control panel 4. Front cover 5. Caster 6. Handle 7. Power cord 8. Drain port 9. Upper filter frame 10. Protective net 11. Lower filter frame 12. Water plug 13. Remote control 14. Exhaust hose 15. Window kits 16. Hose adaptor

Installation Warning: Before using this unit, it is important to keep it upright for at least 2 hours. The unit can later transported to another room. Please note the following instructions: Assemble hose adaptor (picture 1) (Picture 1) 1. Prepare the male and female parts of the hose adaptor. 2. Each side holds one part and can be assembled easily. Remark: Do not push too hard to prevent any damage. Assembly of the exhaust hose (picture 2) (Picture 2) 1. Lengthen one head of the hose; screw it into the unit in an anti-clockwise manner. 2. Remarks: screw it into its place, no less than three rounds. 3. The same way to connect the hose to the assembled adaptor( At least three circles) Installation of window kits 1. Partially open the window and then fix the window kits to the window (pictures 3 & 4 below). 2. The window kits can be installed on most normal and vertical windows, and adjustable. (Picture3) (Picture 4)

Please make sure the unit is upright. 1. The unit should be placed on a flat floor and 50cm away from surrounding objects (Picture 5) (Picture 5) 2. Fix the other end of the exhaust hose to the air-outlet window kit (pictures 6 & 7) Warning: (Picture 6) (Picture 7) The length of the soft tube extends from 28cm to 150cm, which is exclusively built for this model. Do not use the fully lengthened hose or any other hoses instead as this will cause damage to the unit. The air-exhaustion pipes and openings must have a good ventilation If not the unit may overheat causing it to malfunction. Please note: Do not bend the tube at any time, as this will cause damage to the tube.

Controls and Settings The portable air conditioner (Cooling only) has three main functions: cooling, dehumidifying and fan. (Please refer to the below diagram picture) Display Fan Timer Mode Sleeping area Swing speed Max cool Up Down Signal Receptor On/Off 1.1 When you first plug in the unit, it will enter into standby status. The digital screen will indicate the temperature (Range: 5~35 ºC / 41~95 ºF). If the ambient temperature is above 35 ºC, the screen will show H. If it is below 5 ºC, it will indicate L and the unit will enter into standby status. 1.2 ON/OFF button: When you press the On/Off button, the unit will enter into cooling mode (Setting temperature 24 ºC /75 ºF), and the speed of the fan will be on high. Press it once again to turn off the unit. 1.3 Mode button: Press the Mode button to select between Cooling, Fan, or Dehumidifying Mode. 1.4 Fan Speed button: Press the Fan button to change between the 3 speed levels. HIGH MEDIUM LOW 1.5 Timer button: a. Under cooling mode (High/Medium/Low) b. Under fan mode: (High/Medium/Low) c. Under dehumidifying mode, the fan only works on low speed. d. If you switch between cooling and fan modes, the fan speed will not change. Press the button buttons. and the icon will start to flash. Set the hours and minutes using the Adjust the hours and the minutes as per your choice. The interval in the hours is one hour and those in the minutes in intervals of 10.

The Auto-shut-off timer is only available when the unit is on. The Auto-run timer is only available when the unit is off. Once the timer is set, the icon will keep on flashing until it reaches the due time. If the timer needs to be set again, the previous record will be deleted automatically. 1.6 Up and Down buttons: Use the Up and Down buttons to set the temperature and timer. When in cooling mode, the temperature ranges from 18~30 ºC / 64~86 ºF. Press the Up and Down buttons simultaneously to switch between ºC and ºF 1.7 Sleeping key : When in cooling mode, press the Sleep key to turn the unit into sleeping mode. The temperature will automatically adjust to 27ºC and the fan will run at the low speed. If the room temperature is <27ºC the compressor will be off. When the temperature of the room raises over >27ºC, the compressor will automatically start to work. The LCD will indicate icon. Press the same button once again to cancel the Sleeping function. 1.8 Swing button : Press the swing key to activate the auto swing function. This will circulate the air in a uniformly manner in the room. Press it once more to off the function. 1.9 Max cool key : The portable Air conditioner cooling mode only works when the room temperatures is above 18ºC. If the temperature ambiance is below 18ºC, the unit will only work under Fan mode or dehumidifying mode. The Max Cool function ignores all the above and when activated will work under cooling mode under any temperature range. The speed of the fan is automatically set to the highest level. (This function is ideal to lower quickly the temperature of a room)

Remote control LOCK RESET Power : Press the Power key to turn on or off the unit. Mode : Press the Mode key to select between cooling, dehumidifying or fan function. Up : Press the Up key to increase the temperature or adjust the time. Down : Press this down key to decrease the temperature or adjust the time. Fan : Press the Fan key to set the fan speed. Swing : Press the Swing key to activate the Auto swing function. Temperature : Press this key to select between Celsius and Fahrenheit. Sleeping : Press the Sleeping key to enable this function. (Only under cooling function)

Timer : Press the Timer key to set the time. The first 5 hours can be set in intervals of 30 minutes. The remaining hours can only be set in fractions of hours. Once the timer has been set, the number will blink 5 times on the remote control to confirm the setting. Max. Cool : Under cooling mode, press the Max key to achieve the maximum output. Keypad lock: Use a thin pointed device to lock the buttons of the remote control. A lock appears on the display as per the following picture. Press the same key once again to unlock all the buttons and be able to use the remote control again. (This function can prevent children from using the unit without supervision) Reset: Use a thin pointed device to press the Reset key on the remote control. The remote will set all its parameters back to the default settings. Important Note: Never turn off the air conditioner by unplugging it from the power supply or pulling it from the cord. Always press the "On/Off" button and wait a few minutes before unplugging it. This allows the device to perform a check cycle to verify operation. Anti-freezing protection control When in Cooling mode, if the compressor has worked for over 10 minutes and the copper coil temperature is continuously <2ºC for over 20 seconds, then the compressor and water motor will stop working and the LCD will display E4. The unit at this moment initiates the anti-frost protection and all buttons on the control panel (except for power button) are inactive. Once the copper coil temperature increases back to >8ºC, the anti-freezing protection will stop automatically and the compressor, water motor will start working once again and the machine will recover back to its previous operating state, (in order to protect the compressor, it will be restarted 3min. later) Water-full protection When the water level in the water plate exceeds the warning level, the machine will alert the user automatically and the LCD will display FL. You will need to drain the water from the machine following the section of Water Drainage Compressor delay-protection The compressor will always have a small delay of about 3 minutes in order for it to begin. This means that the compressor is in recovery mode. Only during the first use of the unit, the compressor will come on immediately.

No refrigerant protection When in Cooling mode and dehumidifying mode, if the compressor has worked for over 10 minutes, but the temperature difference between the coil temperature and the room temperature is still less than 3 ºC and this temperature difference has lasted for over 30 minutes, the machine will enter into norefrigerant protection. This means, there is no refrigerant in the unit, so the compressor and water spring motors will stop working, the down fan will stop running, the up fan will run at low speed and lastly the LCD will display E3. Water Drainage The product has an automatic water evaporation system. The circulation of condensed water, cools down the condenser. This not only increases refrigeration efficiency but also saves energy. 1. Manual drainage : a. When the water tank is full and the unit stops working, please turn off the unit and unplug it from the mains. Please do not move the unit abruptly, or the water will spilt out from water recipient. b. Screw off the water cover and unplug the water blocker. (Please see part 12 under section Parts of the SY-AC1200 ) c. Use a water container to remove the water from under the unit. d. When the water is out, plug in the water blocker once again and screw on the water cover properly. (Please see part 12 under section Parts of the SY-AC1200 ) 2. Continuous drainage: a. Screw off the water plug and unplug the water blocker. (Please see part 12 under section Parts of the SY-AC1200 ) b. Use a water pipe to connect it to the water outlet. Lead the pipe to the outside or washroom. c. When the water is out, plug in the water blocker and screw on the water cover (Please see part 12 under section Parts of the SY-AC1200 ) This model has a self-evaporative function, under the cooling mode it is recommended not to use continuous drainage in order to get a better cooling effect.

Maintenance Cleaning Please turn off the unit and unplug the unit before cleaning or carrying out any sort of maintenance Cleaning the surface Clean the housing with a duster or a soft wet cloth. Do not use any chemical solvent (such as benzene, alcohol, gasoline). The surface may damage or may even deform the complete outer casing. Air filter cleaning Clean the air filters every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce. 1) Pull the filter out towards you and then pull it up as shown below. 2) Wash the air filters by immersing it gently into warm water (about 40 ºC) with a neutral detergent, rinse it and dry it thoroughly in a dry place. 3) Install the air filters carefully after cleaning the filters. Make sure these are well assembled before using the unit again.

Open from here If the filter is not too dirty, If the filter is very dirty, use a vacuum cleaner clean it with warm water to suck the dust. The ideal temperature of the water is 40ºC (Picture 8) After Season Maintenance 1. Pull out the plug in a drainage hole and empty the water-receiving plate, or drain out the water by leaning the unit. Then enter into the fan mode, and press the button for 5 seconds until it sets to the low fan speed. Keep this mode on for half a day until its inside becomes dry. 2. Turn off the unit and pull out the plug. 3. Clean its filter screen and reinstall back. 4. Tie the wire and bind it together, then put it into the accessories storage space. 5. Remove the exhaust pipe and accessories and keep them safely. 6. Put the unit into a plastic bag, and then keep it in a cool and dry place. 7. Take out the batteries of remote control and safely keep them. * All accessories can be placed in the accessories storage on the back of the unit. Using the unit after a long time 1. Check whether the water plug and filter screen are installed. 2. Check whether the power cord is intact. If it has any signs of breakage, do not use the A/C 3. Reinstall the remote control batteries. 4. Reinstall other parts following the installation instructions.

Troubleshooting Do not attempt to disassemble, repair or alter the equipment yourself. This will void the warranty. The following table lists the common failures and maintenance methods of the series of portable air conditioners. When the machine runs abnormally, the following table can be a simple diagnose and repair prescription. If the problem persists, contact Sytech Technical service center. TROUBLE POSSIBLE CAUSE SOLUTION The A/C doesn t work The refrigeration effect of the conditioner is not good Not plug in Plug in The display panel displays Restart the A/C after power off and P2 drainage process. The unit should work fine. The Off timer function is activated Restart the unit after turning it off for 3 minutes. Direct sunlight Doors or windows are open. Room is too crowded or heat source placed in the room Dirty filter screen Air inlet or air outlet is blocked Draw the curtain Close the doors and windows and remove the heat source Clean or replace the filter screen Remove the blockage The air conditioner makes too much noise The compressor Does not work The A/C is not placed on a flat level The compressor delay protection has been activated Place it on a flat and solid surface and try avoid shaking. Wait 3 minutes and restart the machine when its temperature is reduced. E1 on LCD Coil temperature sensor failure check coil temperature sensor or relevant E2 on LCD E4 on LCD Remote control doesn t work Indoor temperature sensor failure Anti-freeze protection. When the coil temperature is below 0ºC, the whole machine will stop. When the coil temperatures raises to 8ºC or more, the protection will disconnect and the unit will restore to its original working state. The distance is too far. Control panel has not received the signal from remote control. The batteries are weak. circuit check room temperature sensor or relevant circuit Wait for the coil to defrost. The machine will restart automatically. Get closer to the unit and aim the remote control to the Air outlet grille Change the batteries

Important information for the correct disposal of the product in accordance with directive 2002/96 / EC. At the end of its useful life, the product should not be disposed off with household waste. It must be taken to a special selective collection center of the municipal agencies or to a distributor who presents this service. The correct elimination of an electrical appliance avoids possible negative consequences for the environment and health derived from an inadequate elimination and allows to recover its materials to obtain significant savings in energy and resources. As a reminder of the need to dispose of the appliances selectively, the product is marked with a trash can with wheels crossed with an X. DECLARATION OF CONFORMITY Manufacturer Name: Satyatrade S. L. Address: Pol. Ind. La Raya. C/ Guadalquivir, 2. Camarma de Esteruelas, 28816 Madrid Tel: 902 430 967 Fax: 91 8864285 NIF: B83254763 Manufacturing country: China Description: Portable Air Condition Sytech SY-AC1200 complies with the following directives: EMC Standard: Directive 2014/30/EU LVD Standard: Directive 2014/35/EU EER Standard: Directive 2009/125/EC ROHS Standard: Directive 2011/65/EU Restriction of Hazardous Substances Signed: Ajeet Nebhwani Utamchandani Sole Administrator