Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

Similar documents
Boekel Microplate Incubator

TTT Digital Incubator

Operating Instructions

Refrigerated Incubator Model and Operating Instructions

Water Baths. with BioCote antimicrobial protection. Find out more!

Shaking water baths. OLS26 Orbital/Linear shaking water bath. LSB12 & LSB18 Linear shaking water baths

OLS26 Aqua Pro Orbital / Linear shaking bath. Offering ultimate flexibility and usability for all applications

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Digital Heat Block User Manual

Shaking Water Bath OLS Aqua Pro

External and internal circulation with powerful pumping capability

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Unstirred Baths FLD Series. Unstirred DuoBaths. Note:

REFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument

Operator s Manual General Purpose Water Baths

Peltier cooler/heater PCH-1 / PCH-2

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

Unstirred Water Baths

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

ES-20 Orbital Shaker-Incubator

Unstirred Water Baths

Note To The User: This product has updated features not yet mentioned in the product manual.

Digital incubating/ refrigerating benchtop shakers

MD-MINI Dry Bath. Instruction Manual

Scientific Equipment. Reference Catalogue. Precision temperature control, sample preparation and life sciences products for the world s laboratories

Thermo Scientific Laboratory Products

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Operators Manual. Microprocessor Controlled. Water Baths

Pasto Sous vide water bath

NEW products for 2012

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand :

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

Mark 25 Ultrapure Water Conductivity Analyzer

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

USER S OPERATING AND INSTRUCTION MANUAL

TS-100C. Thermo-Shaker with cooling for microtubes and PCR plates. Operating Manual Certificate. Medical Biological Research & Technologies

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

CO2 Incubators The Complete Line

Corning LSE Digital Dry Bath Heater

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

Custom Products for Research. Kugelrohr Short Path Distillation

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

CLS-1450 Series Spinner Flask Instruction Manual

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Marco Beverage Systems Ltd.

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

OPERATING INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Eldex Column Heater. Operator s Manual

M770 ph Controller Owner s Manual

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

s ter k Hea y Bloc Dr

Premium Laboratory Equipment. Bio Tools

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

4L Instant Water Boiler Instructions for Use

IMPORTANT: ALWAYS FILL

Hi-Temp Bath Installation and Operation Manual

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Operators Manual. Microprocessor Controlled. Water Baths

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

P/N CC-100. Coolant Circulator. Operation manual

INSTRUCTION BOOKLET. Electric Steam Sterilizer

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

Incubators. with BioCote antimicrobial protection

OPERATING INSTRUCTIONS

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

METS MODEL E-112. (115 VAC, 50/60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE TABLE OF CONTENTS

Operating manual. English. Heating Immersion Circulator

Reacti-Therm I and III Heating Modules

i-cube Microplate Incubator E10030

Operating Manual for. Ultrawash Plus. Absorbance. Plate Washing. Luminescence. Automated Processing. Software

METS MODEL E-106. (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE

Your Pope Simple Set Automatic Tap Timer

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

HI COD REACTOR and Test Tube Heater 2008 Series

Operations Manual. Part Number: For Research Use Only

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

FGT5 & FGT6 Gelation Timer. Instructions for use

SOUS-VIDE CIRCULATOR.

TR-SERIES LIFTKLEEN PARTS DRYER

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

DOC JAN06 LT 200

Professional Warming Drawer and Warming Drawer Cabinet

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

INSTALLATION INSTRUCTION for ceiling fan

Transcription:

Shaking Hot Tubs Orbital / Reciprocating Shaking Water Bath 290400 28 Liter 115V 290400S 28 Liter 115V 290400-2 28 Liter 230V Operating Instructions 1

Table of Contents 1. Safety..3 2. Getting Started 4 3. Operation of the Shaking Hot Tub.. 5-6-7 4. Accessories. 8-9 5. Maintenance and Service...9 6. Specifications...10 7. Warranty and Service... 10 2

1. Safety The following symbols mean: Caution: Read these operating instructions fully before use and pay particular attention to sections containing this symbol. Caution: Surfaces can become hot during use. Always observe the following safety precautions: Use only as specified by the operating instructions or the intrinsic protection may be impaired. Do not place fingers or hands below the tray surface while the tray is in motion. Only use tray handles to move the tray. These baths are for water use only. Connect only to a power supply which provides a safety earth ground. Take care when topping or draining, as liquid may be very hot. Do not touch surfaces that become hot during high temperature use. Ensure that the mains switch and isolating device (power supply connector) are easily accessible during use. Connect only to a power supply which provides a safety earth ground terminal. Before moving, disconnect at the power supply socket. Do not connect to a power supply or switch on before filling the tank. If liquid is spilled inside the unit, disconnect it from the power supply and have it checked by a competent person. It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or inside the equipment. Clean the unit only with a damp cloth; do not use chemical cleaning agents. Place unit on a solid, level work surface or laboratory bench. Drain tank before moving the bath. Before draining allow the unit to cool below 50 C. Always use a lid when operating above 60 C. Take care when raising and removing the lid, it may be hot, steam and hot vapors can cause scalding. 3

2. Getting Started 2.1. Unpacking Remove packing materials carefully, and retain for future shipment or storage of the unit. 2.2. The Shaking Hot Tub package includes: 2.3. Trays 2.3. Installation The Shaking Hot Tub External Power Cord Polycarbonate Lid Drain tube Operating Instructions Refer to section 4 page 8 for a complete description of the trays available. ATTENTION The bottom of the Universal Flask Tray is comprised of magnets. Take care to ensure magnets do not come in contact with any metal components on your lab bench. Using desired tray, place the tray into the bath, the tray is self positioning and only needs to be located into the approximate center of the tank. The bath is capable of providing an orbital shake or a reciprocating shake by simple reversing the tray. If an orbital shake is desired, place the tray into the bath so that the word Orbital (which is stamp onto the tray) is position towards the font of the bath. If a reciprocating shake is desired, align the tray with the word Orbital towards the rear. Be certain that the drain hose assembly is removed from the drain port prior to filling with the tank. Use water only, fill bath to a minimum of 2 above the base of the tank and the maximum of 3 from the top of the tank when the bath is fully loaded. A lid must be used with the bath at temperatures above 60 C. After bath is filled with water, connect the power line cord to the unit. The power switch is located on the front panel and is used to turn the unit on and off. 4

3. Operation 3.1. Changing the Set Temperature 3.1.1 Press the F button once until tset is indicated on the display. The display will alternate between tset and the set temperature value. 3.1.2 Depress the S switch to enter the Set Temperature mode. 5

3.1.3 Adjust the Increment /Decrement Dial until the desired new Set Temperature is indicated on the display. 3.1.4 When the desired set temperature is achieved, depress the Set switch. This value is stored in memory and the unit will retain this value after the unit is switched off. 3.1.5 As the bath heats up the heater indicator will remain on steady, as the bath begins to reach equilibrium, the heater indicator will flash. 3.2. Setting the Motor Speed 3.2.1 Depressing the tray switch on the front panel will activate the shaking motion, and the tray indicator will illuminate. 3.2.2 Depress the F switch twice and the display will change to SPd and alternate between SPd and the current motor speed setting. 3.2.3 Depress the Set switch to enter the motor speed adjust mode. 3.2.4 Use the Increment / Decrement Dial to obtain the required motor speed. The display flashes when in the Set Motor Speed mode. 3.2.5 When the desired motor speed is indicated, press S again. This value is now stored in memory and the unit will retain this value after the unit is switched off. 3.3. Using the Timer 3.3.1 Depress the F switch three times, and the display will change to CLOC. 3.3.2 Depress the S switch to enter the Timer mode. 3.3.3 Dial the Increment / Decrement Dial clockwise to change the display from OFF to On. 3.3.4 Depress the Set switch to enter the timer adjust mode. 3.3.5 Use the Increment / Decrement Dial to select the desired timer value, a time of between 1 minute and 99 hours and 59 minutes can be selected. The timer value is displayed as HH:MM. When the desired timer value is selected, depress the set again, this turns on the timer and stores the timer duration in memory. 3.3.6 The display will now alternate between the bath temperature and the time remaining as the timer counts down. 3.3.7 When the timer reaches 00:00, the alarm will peep, the heater will shut off, the motor will motor will stop and the display will now alternate between ENd and the actual bath temperature. 3.3.8 Press the F and S simultaneously to shut the timer off and return the unit to normal operating mode. 3.4. Using the High Temperature Alarm 6

3.3.9 The unit is programmed with an adjustable high temperature alarm. The high temperature alarm value is factory defaulted at 5 C above the set temperature value. To change this value, follow the steps below. 3.3.10 Depress the F switch four times, and the display will change to ALAr and will alternate between Alar and the current high temperature alarm value. 3.3.11 Depress the S switch and the display will now flash the current high temperature alarm value. 3.3.12 If a different value is desired use the Increment / Decrement Dial to obtain the desired high temperature alarm value. 3.3.13 When the desired alarm value is indicated, press S switch. This new value is now stored. 3.3.14 If a high temperature alarm condition is encountered the display will flash ALAr, the heater will shut off, and the unit will beep. 3.3.15 This condition will persist until the bath temperature drops below the high temperature alarm set value, or the user raises the High Temperature Alarm setting above the bath temperature. This can be accomplished by depressing the F key; the display will alternate between ALAr and the actual high temperature alarm value. Depress the S switch and the display will flash the actual high temperature alarm value. Use the Increment / Decrement Dial to obtain the new desired high temperature alarm value, and depress the S key to store this new value. Note: If a change to the temperature set point is made or the unit power is cycled on and off, the high temperature alarm value will return to a default of 5 C above the set temperature value. 3.5. Catastrophic Heater Condition 3.5.1 In the event that a chamber temperature would reach 120 C the systems heater will be disabled and remain in the disable mode until the over temperature condition is corrected. 3.6 Draining the Tank 3.6.1 Allow the liquid to cool to below 60 C. 3.6.2 Place the drain hose assemble into the drain port located on the rear of the unit. As soon as the drain hose assemble is snapped into the drain port the bath will begin to drain. 3.6.3 When the bath is drained, be sure to remove the drain hose assembly by depressing button on drain port and remove hose from drain port. 7

4. Accessories 4.1 Universal Tray (290410) The Universal Tray accommodates a wide variety of different vessels. The configuration of the springs can be changed to accommodate the number of each size of Erlenmeyer flask as follows: Quantity Flask Size 43 25 ml flasks 26 50 ml flasks 15 100 ml flasks 11 250 ml flasks 6 500 ml flasks 3 1000 ml flasks The Universal Tray is designed so that springs may be added, moved, or removed to accommodate different shaped vessels. The tray has a series of holes positioned along both the long side and short sides. These holes can be used to attach the springs to fit specific sized vessels. NOTE: The bottom of the Universal Flask Tray is comprised of magnets. Take care to ensure magnets do not come in contact with any metal components on your lab bench. 4.2 Tray for Test Tube Racks (290420) The Test Tube Tray will accommodate up to 5 Test Tube Racks. The Test Tube Racks are available in 6 different test tube sizes. The chart below describes the each Test Tube Rack item number, the size and quantity of test tubes that it can hold. Test Tube Rack Item # Tube Capacity Tube Size 290421 48 10mm 290422 44 13mm 290423 24 16mm 290424 21 19mm 290425 12 25mm 290426 6 30mm 8

4. Accessories (cont d) 4.3 Perforated Tray (290430) The perforated tray is used to convert the bath to an ordinary unstirred water bath. To install, remove the tray that is presently installed in the tank. Place the Perforated Tray directly on the bottom of the tank, positioned over the roller ball bearings. 4.4 Gabled Lid, Stainless Steel (290320) 4.5 Bath Algaecide (B1906001) 5. Maintenance and Service The adjustable high temperature alarm cutout should be tested periodically by setting the high temperature alarm value below the set temperature value, when this condition is present the unit should go into high temperature alarm failure as indicated in step 3.4.6 The unit is equipped with circuit breaker(s) on the rear of the unit. The breakers are reset by depressing fully. To ensure optimal performance of the shaking mechanism, the tray, and bottom of the tank including the transfer ball assembly should be cleaned periodically to remove any scale build up. The tray and the bottom of the tank can be cleaned with warm soapy water. If desired, the transfer ball assembly can be removed and cleaned with warm soapy water as well. To remove the transfer ball assembly, remove the 3 nuts holding it in place. Be certain not to remove any of the 4 transfer balls, the positioning of these balls is critical to the operating of the unit, and their location has been factory calibrated. If bath is going to unused for more than a couple of days, it is recommended to drain the water from the tank. This will prevent the any possibility of corrosion which can occur with distilled or deionized water and even some tap water, even with the high grade of stainless steel used in the manufacture of this unit. When the bath is used under certain conditions, algal growth can occur which can be mistaken for rust. This can easily be cleaned off using warm soapy water. Boekel recommends the use of a bath algaecide, item # B1906001 to help maintain the bath water. Apply treatment at a dose of 20 drops per 1 gallon of distilled water, free of visible algae. 9

6. Specification Temperature Range Ambient +5 to 100 C Uniformity ±0.1 C Stability ±0.2 C Display Resolution 0.1 Heat up to 65 C - 45 minutes Timer Settable from 1 min. to 99 hrs. 59 min. Orbital Radius 10mm Linear Stroke Length 20mm Overall dimensions (W x L x H) 33cm x 56cm x 35.6cm (13 x 22 x 14 ) Weight 15.4kg (34lb) Power Rating 115VAC - 9.65A - 60Hz. 230VAC - 4.83A - 60Hz. 1122w 1122w 7. Warranty and Service 7.1. Warranty 7.2. Service When used in laboratory conditions and according these operating instructions Boekel warrants this product to be free of defective parts, material and workmanship for a period of two years from the date of shipment. The liability of Boekel Scientific for any defective equipment during the warranty period shall be limited to the repair of defective equipment or replacement thereof without charge for parts or labor. A Boekel Scientific Returned Material Authorization (RMA) number provided by Boekel Scientific is required before any Boekel products are returned for any reason. Contact Boekel Customer Service at 1-800-336-6929. A Decontamination Certificate must be completed, signed by the user, and returned to Boekel Scientific prior to receiving the RMA number. Please be sure to mark the outside of the returned goods package with this RMA number to ensure prompt handling. 10

Boekel Scientific 855 Pennsylvania Blvd. Feasterville, PA 18053 Phone: (215) 396-8200 or (800) 336-6929 Fax: (215) 396-8264 Email: Boekel-info@boekelsci.com 11