XFlat Blade. Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL. CoolingOnly,Heat Cool,and Heat Pump MULTI-STAGE SEVEN DAY PROGRAMMABLE

Similar documents
Installation Instructions

Installation Instructions

1 For All Programmable Digital Thermostat

OWNER S MANUAL Venstar Inc. 08/07

Small Digital Thermostat Controller Temperature Control

Programmable Digital Thermostat

Installation, Start-Up, and Operating Instructions

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

HEAT HEAT HEAT COOL COOL

2 - Wire Programmable Digital Thermostat

HEAT COOL. Meets Commercial California Title 24

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEM22P7S COMMERCIAL. Model HVAC SERVICE PARTS

Installation, Start-Up, and Operating Instructions

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

Owner s Manual. Part Number 33CS250-01

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

OWNER S MANUAL Venstar Inc. 08/07

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Installation, Start-Up, and Operating Instructions

Owner s Manual. Digital Thermostat

OWNER S MANUAL Venstar Inc. 08/07

5+2 Day. up to HEAT COOL

OWNER S MANUAL. Part Number P CONTENTS

7-Day. Digital Thermostat. residential. & 2-cool

5+2 Day. up to HEAT COOL

Owner s Manual. Part Number 33CSCPACHP-01

OWNER S MANUAL. Part Number P

Installation Instructions HEAT COOL FAN POWER

Installation Instructions

Programmable Digital Thermostat

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

Owner s Manual Use with most Heat Pump systems: 1-Heat, 1-Cool 2-Heat, 1-Cool

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

Non-Programmable Digital Thermostat

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCPS101 TSTATBBPS101 P Digital Thermostat 6:03

7-Day. Digital Thermostat. residential. & 2-cool

Owner s Manual. Part Number 33CS250-RC

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Installation Instructions

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

Owner s Manual. Digital Thermostat. Non-Programmable

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

Auto-Changeover: Cool Setpoint: Deadband: Differential: Heat Setpoint: Icon: Mode: Non-Programmable Thermostat: Programmable Thermostat:

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

OWNER'S MANUAL T0140. Contents Page #

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

HEAT COOL HEAT PUMP. Installation Instructions TSTATCCNB001 TSTATBBNB001 P Digital Thermostat

COMMERCIAL. model SFTHCP742WFC. Premier Series Digital Thermostat. Programmable. Owner s Manual. and Installation Instructions

NON- INSTALLATION INSTRUCTIONS Venstar Inc. 08/07. Digital Thermostat T2700. commercial. & 2-cool. up to 2-heat PROGRAMMABLE

HEAT HEAT HEAT COOL COOL

HEAT HEAT PUMP TOTALINE. Installation Instructions DIGITAL THERMOSTAT MODEL P FM. I2:00 Mo COOL

HEAT COOL 5+2 DAY PROGRAMMABLE 1-STAGE HEAT, 1-STAGE COOL. Installation Instructions TSTATCCPQ501 TSTATBBPQ501 P Digital Thermostat I2:00

Installation Instructions

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

Owner s Manual. Digital Thermostat. Heat/Cool & Heat Pump 7-Day Programmable S1-THEU22P7S RESIDENTIAL. Model HVAC SERVICE PARTS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

SC Installation, Operation & Application Guide

OWNER S MANUAL. Part Number P RF

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

SC Installation, Operation & Application Guide

Smart Temp. Model

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Owner s Manual. Premier Series Digital Thermostat. and Installation Instructions. Non-Programmable with Humidity Control COMMERCIAL

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Installation, Service, and Troubleshooting Instructions

TC --- NHP, TC --- NAC Comfort Series Non---Programmable Thermostat. Owner s Manual

Programmable Thermostat

DAY/TIME Button: Selects hour, minute and day setting.

Programmable Thermostat

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

asy Single Day up to 2-heat & 2-cool Stat

CAUTION: ELECTRICAL HAZARD

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

5+2 DAY PROGRAMMABLE DIGITAL THERMOSTAT

SAT-3 Room Temperature Controller

ATP21W02 CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS REMOVING OLD THERMOSTAT 2 THERMOSTAT DETAILS

Installation Instructions

For Quick Set-Up go to Page 14

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Commercial Touchscreen Thermostat

SC Installation, Operation & Application Guide

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Programmable 5-2 Day Digital Thermostat

Operator: Save these instructions for future use!

INSTALLATION INSTRUCTIONS

DAY/TIME Button: Selects hour, minute and day setting.

Product Data TSTAT. Thermostats Thermidistat TM Control BUILDER S THERMOSTAT NON-PROGRAMMABLE THERMOSTAT FEATURES/BENEFITS

Performance Non-Programmable Owner's Manual

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

SMART TEMP UNIVERSAL 7-DAY PROGRAMMABLE THERMOSTAT (FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS) INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Installation Instructions DIGITAL THERMOSTAT 53DFS250-SL CoolingOnly,Heat Cool,and Heat Pump B. Assemble tools: o MULTI-STAGE SEVEN DAY PROGRAMMABLE XFlat Blade Screwdriver Wire Cutter and Stripper C. Carefully unpack the thermostat. Save the screws, bracket, and instructions. D. Turn off the power to the system at the main fuse panel. Most systems have a separate breaker for disconnecting power to the indoor and outdoor units. STEP #1 PREPARATION STEP #2 WIRE CONNECTIONS SAMPLE WIRING DIAGRAMS STEP #3 TEST OPERATION ADVANCED SETUP ABOUT ADVANCED FEATURES AND OPERATION TROUBLESHOOTING CALIBRATION I IMPORTANT: Follow Installation Instructions carefully CAUTION: DISCONNECT POWER TO THESYS- TEM BEFOREINSTALLING THE NEW THERMOSTAT, SERIOUS PERSONAL INJURY MAY RESULT, This device complies with Part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. 1 1 2 2 2 3 5 5 _ / :l-jf_p-1 i'_'ii tit:l [_o] _,I_,I<q / [o] _,[,.'t Refer to the chart below, or the wiring diagrams that follow for thermostat functions and corresponding thermostat connectors. Remote FUNCTION Lo Fan Compressor Heating 24 v Power Common Rev. Valve Hi Fan Sensor +5vdc Remote Sensor Signal Remote Sensor Ground Dry Contact Switch 1 Dry Contact Switch 2 Defrost *Only used with Heat Pump systems. INSTALL ON THE NEW THERMOSTAT CONNECTOR MARKED Gt Y H2 R C O* G2 RS+5 RS RS GND CK1 CK2 H1 _I:l:_ r_ I"J-'l=1;/-'I-'Y-'I/ [o]_,i A. Proper installation of the thermostat will be accomplished by following these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 02-DFC535SI Printed in U.S.A. Form 53-5SI Pg 1 11-05 Replaces: 53-2SI

F..,lZ_TI_ kv_vtf'il_jii,._j_j_l i_i4 I: I al/ I'.JI]F4"j 0 o o the thelmostat to the RS+5 CKt I-0 RS R_od cabn from lho to th_ equipment. t_at OK2 A. Turn the power on to the HVAC (heating, ventilation, and air conditioning) system. B. Press the Mode button until the HEAT icon appears on the display. Press the Up or Down buttons until the set temperature is 10 degrees above room temperature. The unit will turn on and supply heat. C. Press the Mode button until the COOL icon appears on the display. Press the Up or Down buttons until the set temperature is 10 degrees below room temperature. The unit will turn on. NOTE: Most equipment has a time delay between cycles. This feature is defeatable on the thermostat. See the Advanced Setup section. D. Press the Mode button repeatedly until OFF is displayed on the thermostat. COMMON o _ POWER cc /_t LO FAN... Follow the steps below to complete Advanced Setup, which begins with Step 3. Refer to the Owner's Manual to complete Setup Steps 1 and 2. COMPRESSOR >- _... REVERSINGvALVEO I_t located NOTE: ateach the top step number corner is of MODE Press the Mode button, right While holdtn# the Mode button, the display for easy reference. AUX HEAT _: I_) PROGRAM enter the Advanced Setup screens HIGH FAN _ I( } DEFROST _: I_ '_... J On Select residential Heat OFF button to Q press the Program _ On or Off. (_ Pump, Off (_ Adjustthe deadband (_ frorn t (1to to6 6degrees. F) (_ Adjust the minimum _between cooling and heating J 3 conductor 18 gage unsmelded cable from the thermostat to the _ setboints, (0 to 6 P) RS43ND Select hour _) lirng. the cycles per d=cycles per hour I- Or_ 8Condoctor 1_, 1_g_th unshieldedca e rorn e thermostat the equipment. to dl=d + defeat 5 rain. limit defeated. _) Combresso_ lockout. (d, dt,2-6) COMMON 0 Select the security level: O=no security in effect 24 v POWER Cc LOFAN _ t 2=1+ =set program point range on all limited times 3=2 _ prohibits set point changes COMPRESSOR >- AUXNEAT_: NIGNPAN_ NOTE: For cooling only the H2 connection is not required. _) Adjust the maximum allowable heat set point when (Step security 8 only appears is in effect. if Step 7 is not O) (35-99 F) Adjust the minimum allowable cool set point when security is in effect. (Step 7gisonly not appears O) if (35-99 F) Page 2

c i Select thermostat operation in degrees j) Fahrenheit or Celsius. F _On Select the display backlight always On, or Off (_ after 8 seconds. off Adjust the preoccupancy fan purge timer. 0:00 = off 0-3 hours. 'Soft Start'. This is used in multiple installs to [r4'am] on times. 0 = off. stagger equipment turn (_ Select Each Number the unit= ID(30seconds) for y second delay, (0 to 99) ON F Z _3 {ttp n Press the Mode button. While holding the Mode, press the Program button to leave the Setup screens, If no buttons are pressed, the display will leave the setup screens after 30 seconds. Se/up _J This minimum difference is enforced during Auto changeover and Program On operation. ENERGY SAVING SMART FAN -- If Fan On is selected, the fan will run continuously at all times, except in Off, and will only run if there is a heating or cooling demand in Unoccupied periods. OVERRIDE -- Press the Override button during a programmed, Unoccupied period to force the thermostat into the Occupied 1 period, temporarily, up to 4 hours. If the Override button is pressed during an Occupied period, the thermostat will be forced into the Unoccupied period and the occupied number (1,2 or 3), it was forced out of will be turned off, only for that day. During Override periods the set point temperature may be adjusted, but it will not be remembered after Override ends. HEAT-- First Stage = Heat Pump. Second Stage = Heat Pump and Electric Heat. FAN PURGE TIMER -- When this feature is activated, the fan will turn on during the Unoccupied period at a preset amount of time prior to the Occupied 1 period. This preoccupancy fan purge timer may be set as instructed on this page, Step 12, from 0 to 3 hours. 0 = this feature turned off. KEYPAD LOCK -- To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or 'lock' the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will appear on the display. Advanced Setup Table STEP DESCRIPTION RANGE FACTORY NO. DEFAULT 1 Time of day clock set 24 hour 12:00 Am 2 Day of the week Su - Sa Mo 3 Heat Pump Off / On Off 4 Deadband or Temperature swing 1-6 F 2 F Forced minimum difference heat/ 5,_ool 0-6 F 2 F 6 Cycles per hour d, dl, 2-6 6 7 Security Levels 0-3 0 8 Maximum allowable Heat set point 35-99 F 80 F 9 Minimum allowable Cool set point 35-99 F 65 F 10 Fahrenheit or Celsius F/C F 11 Thermoglow TM backlight Off / On On 0:00-3;00 12 Fan Purge timer min, 0:00 min, 13 Soft Start 0-99 0 TWO-STAGE OPERATION -- The second stage of heat (heat pump models only) is turned on when (1) the first Stage has been on for a minimum of two minutes, and (2) the temperature spread from the set point is equal to or greater than: the setpoint temperature plus the deadband, plus 2 degrees. Heating Coo_ing Press all 3 for _ [ _i_[_in_ n _S Keypad Lockout _ "_ [ ON Looked To unlock the buttons, again press and hold the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will disappear from the display. DRY CONTACT SWITCH -- The terminals are 'normally open.' Closing or completing the circuit will cause the thermostat to enter the Occupied 1 period. This feature allows an external device such as a central time clock, occupancy sensor, or a telephone-activated device to force one or more thermostats into the Occupied 1 period. For the dry contact switch to work, the thermostat must be in Program On. Set Occupied 1 to Off for all 7days, so the contact closure will be in control. When the thermostat is forced into the Occupied 1 period via the Dry Contact closure, the icon Occupied 1 will blink. IMPORTANT: Forcontrol of multiple thermostats by [ one source, refer to Potential Phasing Problems (document part no. 88-173) prorto nsta ng. SS I 2ndStage lststage Heat Coo_ rnon turnon SetPoint Se/PoJnt turnon 3rdStage 2nd Stage 1st Stage Low Mad High _ Fan Speeds High Mad LOW MINIMUM HEAT/COOL SET POINT DIFFERENCE -- The Heat and Cool set point temperature will not be allowed to come any closer to each other than the value set in Advanced Setup Step 5, on page 2. Page 3

HOLIDAY MODE -- This feature forces the thermostat into Unoccupied for a preset duration, up to 99 days, The Holiday setup display is entered as follows: @ HOLIDAY S HOL acti the display i_ counts remainingdown days _Anlbl blinking. Unoccupied appears. / /, Press the Up or Down buttons to select the... _ number of days the thermostat will be in Holiday mode. 0 = Off. To exit Holiday setup, / press the Mode button. The thermostat will enter the Holiday mode when the clock crosses midnight. During Holiday mode Unoccupied period set points are enforced. The Override button is active during Holiday mode. It will override to the Occupied 1 period settings up to 4 hours then return to Holiday mode. The dry contact switch is ignored. The thermostat will exit Holiday mode at midnight of the final programmed day. To terminate the Holiday mode immediately, enter the Holiday mode setup screen and select O. SOFT START -- This feature is utilized in multiple thermostat installations controlled by the dry contact terminals. Assigning a unique soft start number to each thermostat will stagger the turn on times, even though the dry contact closes, for all the thermostats connected, at the same time. Each soft start number represents a multiple of 30 seconds from the dry contact closure. For example, no. 1 = turn on 30 seconds after dry contact closure, no. 2 = turn on 60 seconds after closure, no. 3 = turn on 90 seconds after closure, and so on. See page 3, Step 13, to configure the thermostat for Soft Start. DUAL SET POINT BEHAVIOR -- The adjustable set point range is: 35 to 99 degrees in Fahrenheit and 7 to 35 degrees in Celsius. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming Occupied and Unoccupied set points, the thermostat will not allow the Heat set point to get closer to the Cool set point than the value programmed as the minimum difference in Step 5, page 2. When entering the Auto mode from Cool, the Heat and Cool set points will remain spread apart by the also amount that they were adjusted, Auto mode. prior to entering For example: If the Cool set point was set to 80 F while in the Cool mode and the Heat set point was adjusted to 70 F while in the Heat mode, upon entering the Auto mode the Heat and Cool set points would be 80 F and 70 E Both set point temperatures would then move up and down together, (in this example spread by 10 degrees), by pressing the up or down buttons. To move the Heat and Cool set point temperatures closer together, enter the Cool or Heat mode by pressing the Mode button, then adjust the set point temperatures closer together. Heat is limited to how close it can come to Cool by Step 5, page 2. REMOTE SENSORS (Optional Accessory) -- When connected to terminals RS+5, RS, and GND on the back of the thermostat, the thermostat will read the temperature from the remote sensor and ignore the temperature sensor inside the thermostat. The thermostat automatically recognizes when a remote sensor is connected. When reading the temperature from the remote, the degree icon above the room temperature blinks once a second. The Override button on the remote sensor works slightly different than the Override button on the front panel. Optional Each press of the Remote Sensor 'External' Override button Optional Sensor adds 2 hours to the override timer, if the timer was already active, the first button press will round the runtime to either 2:00 or 4:00. Subsequent button presses will not wrap around as the Override button on the thermostat does, so the second or subsequent button presses will set the runtime to 4:00. The Locked feature has no effect on the external Override button. The wired remote sensor is connected to the thermostat with up to 450 ft of 22 gage, 300 ft of 20 gage or 150 ft of 18 gage thermostat wire. See the Remote Sensor instructions for further details. FACTORY DEFAULTS -- Before restoring factory defaults, set thermostat to OFF mode. If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Fan button for 5 seconds. All icons will appear. Press and hold in the Fan button until Fd appears. This resets all factory settings. To calibrate room temperature, see the Calibration section on page 5. Page 4

ii ;[oil] :] II:[,.']:[oIo]l/ I_[_ SYMPTOM When not using a common wire the air conditioning equipment tries repeatedly to turn on, but cannot. At times the display dims or disappears. CAUSE There is not enough _ower available to 3ower share." The air conditioning The compressor timer does not attempt to lockout may prevent turn on. the air conditioner from turning on, for a )eriod of time. The display is blank. Lack of proper power. The air conditioning does not attempt to turn on. The heating does not attempt to turn on. The strip heater turns off well before reaching set point. The cooling set point is set too high. The heating set point is set too low. Heat pump is incorrectly selected "on" in the Advanced Setup. REMEDY Connect a 270 ohm, 10 watt power resistor at the unit as shown below. For Problem A/C For Problem Heat See the Advanced Setup section to defeat the cycles per hour and compressor time guard. Check for 24 vac between R and C. Press the down arrow until the cooling set _oint is 10 degrees lower than the room temperature. Press the up arrow until the heating set _oint is 10 degrees higher than the room temperatu re. Select heat pump "off" during Advanced Setup programming. See the Advanced Setup section [@±IeI:1;T±'ai [e]zi Every thermostat is calibrated before it leaves the factory. Under normal circumstances there will never be a need to recalibrate the thermostat again. To accommodate special needs, the thermostat may be recalibrated following these steps: 1. While holding the Mode button in, press the fan button in for 5 seconds. After all the icons in the display appear, release the buttons. 2. Press the Up and Down arrow buttons simultaneously, twice. 3. Press the up or down buttons until the flashing number equals the current room temperature. 4. Press the Mode button to return to normal operation. Page 5

Copyright 2005 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. 02-DFC535SI Printed in U.S.A. Form 53-5SI Pg 8 11-05 Replaces: 53-2SI