SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Similar documents
SEC Signature Process Gas Analyzer

SEC Millenium Carbon Dioxide Gas Detector

Hydrocarbon Gas Detector

SEC 5000 IREvolution Gas Detector

SEC Millenium Hydrocarbon Gas Detector

Operation and Maintenance Manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

PUV, PIR and PFO Series BROCHURE

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger PIR 7200 Toxic Gas Detection Transmitter

SIMRAD GD10PE IR GAS DETECTOR

Dräger Polytron Pulsar 2 Open Path Gas Detector

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

INSTRUCTIONS. PointWatch Infrared Hydrocarbon Gas Detector PIR9400

Model D12-IR. Digital Gas Transmitter...

GAS PLUS ALARM SYSTEM

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

Instructions

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Lamp Supply (Recommended)

Compact Sensor Heads for In-situ and Non-Contact Standoff Gas Sensing using TDLAS in Harsh Environments

SIMRAD GD10 IR GAS DETECTOR

An FT-NIR Primer. NR800-A-006

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

DF-340E PROCESS ANALYZERS APPLICATIONS FEATURES

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Key Features. General Description

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

IR15 Dual Gas Series Datasheet

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

IR25 Dual Gas Series Datasheet

Dräger PIR 3000 Detection of flammable gases and vapours

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector. PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW

Operation and Maintenance Manual

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Datasheet: K-22 LO Sensor

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

Instructions. PointWatch TM Infrared Hydrocarbon Gas Detector Model PIR Rev: 9/

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

Accuracy by Design Products for the HVAC Professional

Sitron s CF Line of Flow Switch Monitors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

Using the Model 1500 Portable Chilled Mirror Hygrometer

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Dräger PIR 7000 Flammable Gas Detection

OPEN PATH DETECTION OF ACROLEIN LEAKS

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

CO 2 Laser. High Reliability and Performance

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Oxygen Deficiency Monitor and Oxygen Analyzers. Oxygen Sensors for 0-25% and ppm

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SIEMENS ULTRAMAT 6 IR CARBON MONOXIDE ANALYZER METHOD VALIDATION FOR TESTING CARBON MONOXIDE IN NITROGEN, NF

-smartgas- A new low cost infrared gas sensor for domestic and automotive applications

Ronan Model X96S Series Weighing System

OPTISENS TUR 2000 Technical Datasheet

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Products and performance

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

CLARITY II TURBIDIMETER

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

SEC 2000 Millenium Infrared Gas Detector

IR1 Single Gas Series Datasheet

Technologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Model OEM-2 INSTRUCTIONS FOR USE

Section B Field Instruments

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

InfraSpec NR800. FT-NIR Analyzer. Bulletin12Y03A03-01E

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

Intelligent Infrared Carbon Dioxide Module (Model: MH-Z14A)

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Dew-Point Transmitters and Instruments

User Manual. PolyGard CO LC-1112 V3. Electrochemical analog carbon monoxide transmitters serial no. EC-S 002. August 29, 2006

Instructions. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev: 3/

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

Basic Vehicle Fire Protection Manual

Transcription:

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SEC SIGNATURE ETO MONITOR SIGETO1420597 PRODUCT INTRODUCED TO ETHYLENE OXIDE STERILIZATION INDUSTRY IN 2001. OVER 850 UNITS IN FIELD WORLDWIDE INSTALLED ON STERILIZATION CHAMBERS USING VARIOUS STERILANT GASES 100 % ETO ETO / CO2 OXYIFUME PROPYLENE OXIDE

GENERAL INFORMATION OPERATES ON 24 VDC SOURCED A 4-20 MA OUTPUT TO CONTROL SYSTEM EXPLOSION PROOF ALUMINUM HOUSING INFRARED SENSING TECHNOLOGY LIFE EXPECTANCY GREATER THAN 10 YEARS

SPECIFICATIONS Model: SEC Signature Process Gas Analyzer Ethylene Oxide P/N SIGETO-142-0597 Range (adjustable) Ethylene Oxide 0 2000 mg/liter Max. 0 500 mg/l Min. Detection Method: Infrared Optical / Diffusion Construction: Housing is anodized aluminum with sapphire windows. Rating: Class 1, Division 1, Groups B,C,D CSA (Canadian Standards Association) RFI/EMI Protection: EN-50081-1 EN-50082-1 Accuracy: +/- 5% measured value or +/- 3% full scale (whichever greater) Repeatability: +/- 3% Operating Temperature Rating: -40 to +70 C at 0 to 99% RH (non-condensing) Operating Pressure: 1 PSIA 55 PSIA Altitude: 0-2000 Meters Operating Voltage: 24 VDC. Operating range 18 to 32 VDC measured at the detector head. Output (analog): 4-20 ma (Non-isolated, sourcing) 1000 Ohm load (Max.) at 24 VDC supply voltage. Output (digital): Interactive PC Link Average Power Consumption at 24 VDC: 6 watts Current Draw at 24 VDC: 250 ma (average) 450 ma (peak) Mechanical connection: ¾ NPT male Electrical connection: ¾ NPT male Weight: 18 ounces Wire Connections: Red wire (+ 24 VDC) Black wire (D.C. common) Blue wire (4-20 ma output signal) White wire (Calibration / digital interface) Installation Category: Cat. I, Pollution Degree 2 Approvals: CSA/NRTL Class 1, Division 1 Groups B,C,D (-40C to 50C)

FEATURES CONTINUOUS MONITORING GAS VAPORS INFRARED SENSOR MID INFRARED SPECTRUM EXPLOSION PROOF COMPACT LIGHTWEIGHT FAST RESPONSE TIME SIMPLE CALIBRATION BY END USER SELF COMPENSATING OPTICAL CHAMBER LINEAR OUTPUT UNAFFECTED BY PRESSURE HEATED OPTICS NO MIRRORED SURFACES SELF DIAGNOSTICS DIRECT INSTALLATION ON STERILIZATION CHAMBER SEC SIGNATURE MEASURES GAS VAPOR DENSITY 0 20 MA OUTPUT IMMUNE TO POISONING AND ETCHING LIFETIME GREATER THAN 10 YEARS TOLERANCE AND ACCURACY TOLERANCE IS +/- 2%. ACCURACY: + 5% OF READING OR + 3% FULL SCALE WHICHEVER VALUE IS GREATER. APPLY ACCURACY FOR ANY FOUND READINGS. TOLERANCE IS THE READING AFTER THE INSTRUMENT IS CALIBRATED, THEN TESTED WITH GAS A SECOND TIME. THE TOLERANCE IS +/- 2% WHEN TESTING A CALIBRATED INSTRUMENT. ZERO GAS READINGS +/- 7 MG/L SPAN GAS READINGS +/- 38 MG/L.

100% Infrared Gas Sensors Are Gas Molecule Counters HOW DOES IT WORK? Dual Channel Thermopile Detector Analytical Sensing Channel and Reference Channel 0% Infrared Energy Gas Concentration The SEC Signature Process Analyzer uses infrared absorption technology to identify and measure gas concentrations. Gases absorb infrared light at certain wavelengths due to molecular resonance. Since each gas has a unique molecular structure, each causes a unique light absorption signature. The Signature Process Analyzer measures light absorption at critical wavelengths and uses embedded algorithms to quantify the concentration. The SEC Signature Process Analyzer uses an infrared energy source at one end of the optical path and an infrared sensors at the opposite end. The reliable optical system and lack of delicate components such as beam splitters and mirrors make the Signature Process Analyzer very stable and robust in harsh process environments. Infrared Source Micromachined Black Body

chamber wall IR-ray EO-sensor chamber wall TYPICAL INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION

CONTROL SYSTEMS

CONTROL SYSTEM GRAPHS

MAINTENANCE HYDROPHOBIC FILTERS

HYDROPHOBIC FILTERS TOP PHOTO VERY DIRTY FILTERS REPLACEMENT FILTERS WITH PART NUMBERS SENSOR WITH REPLACEMENT FILTERS

CALIBRATION BENCH TOP CALIBRATION FIRST ZERO THE SENSOR WITH CLEAN AIR OR NITROGEN APPLY 70 % VOLUME ETHYLENE BALANCE NITROGEN TO SPAN CALIBRATE THE SENSOR. 70 % VOLUME ETHYLENE IS THE EQUIVALENT OF 500 MG/L ETHYLENE OXIDE.

ON CHAMBER CALIBRATION ZERO CALIBRATE THE SENSOR WITH HUMIDITY IN THE CHAMBER PRIOR TO ETHYLENE OXIDE INJECTION SPAN CALIBRATE THE SENSOR TO THE CALCULATED IDEAL GAS LAW GAS CALCULATION.

SENSOR CALIBRATION DESCRIPTION IT IS RECOMMENDED THAT AN EMPTY CHAMBER STERILIZER CALIBRATION CYCLE BE ESTABLISHED AND RUN FOR CALIBRATING THE SEC SIGNATURE ETO MONITOR. THE CALIBRATION CYCLE CAN BE A NORMAL OR COMMON CYCLE ALREADY ESTABLISHED. THE MAIN DIFFERENCE IS THAT AFTER THE AFTER THE ETO MONITOR IS SPANNED, THE CYCLE CAN BE ABORTED (ELIMINATING THE ENTIRE ETO DWELL TIME). ONCE THE UNIT IS SPANNED THE CHAMBER CAN RUN THROUGH ITS NORMAL WASHES. THE SEC SIGNATURE IS SPANNED 10 TO 15 MINUTES INTO THE ETO DWELL TIME. THIS GIVES THE CHAMBER TIME TO EQUILIBRATE AND THE ETO CONCENTRATION TO STABILIZE. THE ETO CONCENTRATION DURING THE DWELL TIME IS A CALCULATED VALUE TYPICALLY BASED ON THE IDEAL GAS LAW. THE SEC SIGNATURE IS LINEARIZED THROUGHOUT THE FULL SCALE RANGE OF 0-2000 MG/L. THE SEC SIGNATURE S FULL SCALE RANGE IS A FUNCTION OF THE SPAN PROCEDURE. THE SPAN POINT IS THE 50% VALUE OF FULL SCALE (12 MA). IF THE IDEAL GAS LAW CONCENTRATION CALCULATION IS 550 MG/L AND THE SEC SIGNATURE IS SPANNED AT 550 MG/L THE SEC SIGNATURE S RANGE IS THE FOLLOWING: 4 MA = 0 MG/L 12 MA = 550 MG/L 20 MA = 1100 MG/L THE DEVICE RECORDING THE SEC SIGNATURE OUTPUT SHOULD BE RANGED ACCORDINGLY. 1). CONNECT SEC PC IR LINK TO SEC SIGNATURE. IF SEC SIGNATURE IS POWERED BY A POWER SUPPLY EXTERNAL FROM THE SEC PC IR LINK BOX, CONNECT THE DC COMMON AND WHITE WIRE ONLY TO THE SEC PC IR LINK BOX. IF YOU ARE USING THE SEC PC IR LINK BOX TO POWER THE SEC SIGNATURE FOLLOW THE WIRE OF THE SEC PC IR LINK BOX. 2). ESTABLISH COMMUNICATION BETWEEN THE PC AND THE SEC SIGNATURE, READ SERIAL NUMBER OF SEC SIGNATURE, IT WILL BE 30XXX. NOTE: THE PASSWORD FOR ZEROING AND SPANNING COMMANDS IS: sec 3). START THE CYCLE DURING THE HUMIDITY DWELL TIME, BEFORE ETO GAS INJECTION ZERO THE SEC SIGNATURE ETO MONITOR. USE THE ZERO UNIT COMMAND, IF PROMPTED FOR PASSWORD TYPE: sec THE 4-20MA SIGNAL WILL DROP FOR A FEW SECONDS TO 2.2 MA AND RETURN TO 4 MA. 4). AS THE CYCLE ADVANCES TO ETO INJECTION THE ONCE THE GAS ENTERS INTO THE CHAMBER THE 4-20 MA SIGNAL WILL INCREASE. AFTER ETO INJECTION IS COMPLETE WAIT 10 TO 15 MINUTES FOR THE CHAMBER TO STABILIZE. MAKE SURE THE CHAMBER RECIRCULATION BLOWER IS ON. USE THE SPAN UNIT COMMAND TO SPAN THE SENSOR, PASSWORD IS SEC. THE 4-20 MA SIGNAL WILL DROP TO 2.0 MA FOR A FEW SECONDS WHILE THE SPAN PROCEDURE OCCURS. THEN THE 4-20 MA SIGNAL WILL GO TO 12 MA. THE CALIBRATION IS COMPLETE, THE CYCLE CAN BE SAFELY ABORTED.

MOST COMMON PROBLEMS WATER CONDENSATION IN THE OPTICAL CHAMBER TO RESOLVE THIS ISSUE ADD EXTERNAL HEAT SOURCE TO THE SEC SIGNATURE SENSOR ERRATIC READINGS DURING CYCLE. ETO READINGS WHEN NO GAS IS IN CHAMBER CHECK O RINGS IN THE SEC SIGNATURE SENSOR FOR SHREDDING. IF SHREDDED THE SEC SIGNATURE MUST BE SENT BACK TO SENSOR ELECTRONICS

TROUBLESHOOTING USING PC LINK TO TROUBLE SHOOT THE SEC SIGNATURE SENSOR