ST Wiring diagram. Product description. Four-stage controller. Order number

Similar documents
ST Wiring diagram. Product description. Standard temperature controller. Order number

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Refrigerated air dryers

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Installer Manual KNX Touchscreen Thermostat

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

GMH 285 / GMH 285-BNC

Dixell Installing and Operating Instructions release 7.0

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Installation & Operating Instructions

WH7016E Thermostat Product Manual

EasyTronic III MANUAL SERVICE

PCR-300 PCR-300 RC. Installation and Operating Instructions

1 4 DIN Dissolved Oxygen Controller

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

PARAGON Commercial Refrigeration Controls

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Instruction FH-CWP Thermostat

TDF 15 MICROPROCESSOR-BASED DIGITAL ELECTRONIC THERMOCONTROLLER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA

TEMPERATURE CONTROLLER

XWA11V. Walk-In Temp / Door /Alarm / Light Module

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

/18 (JRK) MTD User Manual OJ Electronics A/S

Table 1. Serie of Digital Room Thermostats.

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

JDDT1 - Single Stage Digital Thermostat

S/601 Controller Installation Manual

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

SA-3841 User Manuel. 1U 4 Fans Unit with Thermostat Sensor. Version 1.1 Copyright All Rights Reserved

SCHMIDT LED Measured Value Display MD Instructions for Use

Capacity controller EKC 331T REFRIGERATION AND AIR CONDITIONING. Manual

Follett Performance Plus

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

OPERATING MANUAL Enertronic Control System 2

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

OPERATION MANUAL. Indoor unit for air to water heat pump and sanitary warm water tank for air to water heat pump system EKHBH007A EKHBX007A

Service Documentation

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Series Temperature Controller Instruction Sheet

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Advanced temperature controller for cold rooms

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

Introduction. OM-THA2

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Thermometers and temperature controllers

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) TC-900e POWER ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

OPERATION MANUAL. Indoor unit for hot water heat pump system and options EKHBH016AB EKHBX016AB

Installation and Operating Manual

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Owner s Manual. Part Number 33CSCPACHP-01

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

FX BLAST CHILLER ISO ISO 9001

Operating Manual Hand-held Measuring Device GMH 3690 GL. for Gaseous Oxygen and Temperature with Alarm Function

Installation Manual Tracker 221

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Autofire Express Ramp/Hold Controller Instruction Guide

User s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.

ETO 2 - Controller for ice and snow melting

DE20 INSTRUCTION MANUAL

Electronic Temperature Controller 70304,

Ver.04 IP 65 FRONT. Serial programming. Protection level FAST FREEZING (ON/OFF) ECONOMIC SETPOINT(ON/OFF) DEFROST (ON/OFF) FUNCTIONS LOCKDOWN

Q-Logic Digital Controls The Q3 and Qht for Direct Expansion Systems

SyringeHeater.com. Syringe Heater. Thermo-Kinetic Heat Clamping. Model: HEATER-KIT-1LG HEATER-KIT-5SP

Connections, displays and operating elements C D E G H. Installing the control unit

Technical Manual Binair Monobloc Heat Pump

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

SERVICE MANUAL REFRIGERATION

Transfer Switch Features

Service instruction Cold

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Operating manual. Wascator FOM71 CLS

C2 Compact Range Installation & Programming Manual

Temperature-Relay TR210

Transcription:

ST96-35.16 Four-stage controller Order number 99.2 Wiring diagram Product description The four-stage controller with 4-digit setpoint and actual value display, 3 keys and 4 relays was developed for the control of compressor groups of up to 4 machines. The switching exits can be programmed as thermostat controllers with additional protection times for the compressor. The switching input E1 allows change-over of the setpoint. The general functions which can be freely parametered open the way for a broad application area. Sensor: Pt1 Range: -99...3 C Front size: 96mm x 96mm Panel cut-out: 9.5mm x 9.5mm Connector: plug and socket

SOFTWARE.16 Adjustment options Key UP Pressing this key you can increase the parameter or parameter value or scroll the parameter list. Key DOWN Pressing this key you can decrease the parameter or parameter value or scroll the parameter list. At alarm the buzzer function can be switched off with this key. Key SET While SET key is pressed, the setpoint is indicated. In addition, the SET key is used for parameters. First control level: Parameter of the main setpoint If none of the keys is pressed, the display indicates the actual value of the temperature. Pressing the SET key, the setpoint shows on the display. If the setpoint is to be changed, the SET key is to be kept pressed while adjusting the setpoint with the keys UP and DOWN. Please note that the setpoint can only be changed within the set setpoint limits Para- Function description Adjustment range Standard meter S1 Setpoint P12...P13. C Custom

Second control level (P parameters): Setting of control parameters Simultaneously pressing the UP and DOWN key for at least 4 seconds opens a parameter list containing control parameters. With the UP and DOWN keys the list can be scrolled in both directions. Pressing the SET key will give you the value of the respective parameter. Pressing also the UP or DOWN key at the same time the value can be adjusted. Return to the initial position takes place automatically, if no key is pressed for 6 seconds Parameter Function description Adjustment range Standard P1 Delta W1-99... 99. K 1. K P2* Delta W2-99... 99. K 2. K P3* Delta W3-99... 99. K 3. K P6** Hysteresis K1.1... 99. K 1. K P7** Hysteresis K2.1... 99. K 1. K P8** Hysteresis K3.1... 99. K 1. K P9** Hysteresis K4.1... 99. K 1. K P12 Control range limitation -99... 999 C -99 C minimum setpoint P13 Control range limitation -99... 999 C 999 C maximum setpoint P19 Key-lock : no key-lock 1: key-lock P2 Indication actual value 1 N/A P21 Actual value correction -1...+1 K. K P3 Lower alarm value -99...999 C -99 C P31 Upper alarm value -99...999 C 999 C P32** Alarm hysteresis.1...99. K 1. K P33*** Total operating time contact... 25 years K1 in years P34*** Total operating time contact... 364 days K1 in days P35*** Total operating time contact... 25 years K2 in years P36*** Total operating time contact... 364 days K2 in days P37*/*** Total operating time contact... 25 years K3 in years P38*/*** Total operating time contact... 364 days K3 in days P39*/*** Total operating time contact... 25 years K4 in years P4*/*** Total operating time contact... 364 days K4 in days Custom * Some parameters are only effective if the corresponding outputs exist. ** The Hysterese is set symmetrically on the switching points. *** To delete or change the operating times P33-P34 parameter A42 must be set to.

Parameter description: P1-P3: Delta W1-W3 Main contact K1 and secondary contact K2 (K3, K4) are linked with one another via switching difference Delta W1 (W2, W3). This difference can take positive or negative values. Thus, a leading or following contact can be realised. In this configuration the controller can be also used as three-point controller. Note: Parameters P2 and P3 are only effective if the corresponding output exists and is included with parameter A44. P6-P9: Hysterese K1-K4 The hysteresis can be adjusted separately for all contacts and is set symmetrically at the setpoints, i.e. half of the hysteresis value is effective below and half of the value above the switching point. Note that a small hysteresis permits a more exact regulation, however also leads to more frequent switching frequency decreasing the lifetime of the relay. Under critical conditions the controller can be equipped with a semiconductor relay. Note: Parameters P8 and P9 are only effective if the corresponding output exists and is included with parameter A44. P12: Control range limitation minimum setpoint P13: Control range limitation maximum setpoint The adjustment range of the setpoint 1 can be limited in both directions. This is to prevent the end user of a unit from inadmissible or dangerous setpoints. P2: Actual value The here indicated temperature presents the actual measured value. P21: Actual value correction This parameter allows the correction of actual value deviations caused for example by sensor tolerances or extremely long sensor lines. The regulation measure value is increased or decreased by the here adjusted value. P3: Lower alarm value P31: Upper alarm value The exit alarm is a boundary alarm or a range alarm with adjustable hysteresis (see parameter P32). The required output contact is set with the operation mode selected with parameter A44. If boundary alarm is selected and only one switching point is required, you have to set the second switching point to a value above or below the operating range of the controller. Boundary alarm function (see fig. 1): The alarm contact is closed if the process temperature is above the upper or below the lower boundary value. Range alarm function (see fig. 2): Opposite switching behaviour to the boundary value alarm. The alarm contact is closed if the actual value remains between the boundary values. Fig. 1: Boundary alarm, rel. boundaries Fig. 2: Range alarm, abs. boundaries

P32: Alarm hysteresis Hysteresis is set symmetrically at the adjusted limit value. It becomes effective depending on alarm definition. The operating time recorded by parameters P33-P44 is mainly used in the field of refrigeration technology to register the operating time of the connected compressors. P33: Total operating time contact K1 in years P35: Total operating time contact K2 in years P37: Total operating time contact K3 in years P39: Total operating time contact K4 in years These parameters indicate the total operating times in years elapsed with the respective contact switched on. P34: Total operating time contact K1 in days P36: Total operating time contact K2 in days P38: Total operating time contact K3 in days P4: Total operating time contact K4 in days These parameters indicate the remaining total operating times in days elapsed with the respective contact switched on. Note: Time is recorded in minute cycles. Periods shorter than one minute are ignored. Storage in the non-volatile memory takes place daily, so that an inaccuracy of max. 24 hours may result if a power failure occurs. Caution: Parameters P37-P4 are only effective when the pertinent output is available and activated by parameter A44. To avoid statistical errors, it is essential that the operating mode set in parameter 44 corresponds to the number of external loads (e.g. compressors) that are connected. Failure to do this will result in incorrect operating times being recorded by parameter P33-P44. Operating times can be updated after replacement of components only if parameters P19 and A19 are unlocked together with parameter A42. Otherwise data can be irretrievable lost.

Third control level, (A parameters): Setting of control parameters Access to the third control level is granted when selecting the last P-parameter on the second control level. Continue to press the UP key for approximately 1 seconds until PA appears. Continue to press the UP key and additionally press the DOWN key for about 4 seconds and the first A-parameter of the third control level is indicated. With the keys UP and DOWN you can scroll the list in both directions. Pressing the SET key will give you the value of the respective parameter. By pressing the UP or DOWN key at the same time the value can be adjusted. Return to the initial position takes place automatically, if no key is pressed for 6 seconds, or by simultaneously pressing the UP and DOWN key for approx. 4 seconds. Parameter Function description Adjustment range Standard A1 Switch mode K1 : heating contact 1: cooling contact 1 A2 Switch mode K2 : heating contact 1: cooling contact 1 A3 Switch mode K3 : heating contact 1: cooling contact 1 A4 Switch mode K4 : heating contact 1: cooling contact 1 A5 Function of contact K1 at : relay off sensor error 1: relay on A6 Function of contact K2 at : relay off sensor error 1: relay on A7 Function of contact K3 at : relay off sensor error 1: relay on A8 Function of contact K4 at : relay off sensor error 1: relay on A1 Temperature scale : Celsius 1: Fahrenheit 2: Kelvin A11 Display mode : without decimal point, without leading zeros 1: with decimal point, 1 without leading zeros 2: without decimal point, with leading zeros 3: with decimal point, with leading zeros A12 Alarm mode : Boundary alarm 1: Range alarm A13 Activation of alarm output : not active 1: active, no flashing display 1 2: active, flashing display A19 Parameter lock : no lock 1: A-parameter locked 2: A- and P-parameter locked A2 Minimum action time K1 ON...999 sec. A21 Minimum action time K2 ON...999 sec. A22 Minimum action time K3 ON...999 sec. A23 Minimum action time K4 ON...999 sec. Custom

Parameter Function description Adjustment range Standard A24 Minimum action time K1 OFF...999 sec. A25 Minimum action time K2 OFF...999 sec. A26* Minimum action time K3 OFF...999 sec. A27* Minimum action time K4 OFF...999 sec. A3 Mutual delay of contacts...999 sec. A31 Delay after Power-on...999 sec. A32 Alarm suppression after...999 sec. "Power-On" A33 Operating time before time...999 sec. or min. 24 depending load replacement A34 Time scale for parameter A33 : seconds 1: minutes 1 A4 Time depending load replacement : no load replacement of the compressors 1: load replacement 1 A41 Sequential operation mode : not activated 1: activated 1 A42 Interlocking of total operating : not locked times 1: locked 1 A43* Function of switching input E1 : no function 1: S1 activated relative to setpoint S1 2: S1 activated absolute (freely adjustable) A44 Operating mode : 2 compressors K1, K2 alarm at K3 1: 3 compressors K1, K2, K3 alarm at K4 2: 4 compressors K1, K2, K3, K4 2 alarm at K5 Custom * If parameter A43 is set to the display will indicate an alarm message in case of closed switching input E1. Outputs K1 K4 will behave like set in parameters A5 A8. An alarm output defined with parameter A44 is not affected.

Parameter description: The following values can change the equipment characteristics and are therefore to be set with utmost care. A1: Switch mode K1 A2: Switch mode K2 A3: Switch mode K3 A4: Switch mode K4 The switch mode for the relays, i.e. cooling or heating function, can be programmed independently at works. Heating function means that the contact opens as soon as the setpoint is reached, thus power interruption. At cooling function the contact closes, if the actual value is above the required setpoint. A5: Function of contact K1 at sensor error A6: Function of contact K2 at sensor error A7: Function of contact K3 at sensor error A8: Function of contact K4 at sensor error At sensor error the display indicates F1- (flashing) and the selected relay falls back into the condition pre-set here. A8: Temperature scale Indication can be switched between Fahrenheit, Celsius and Kelvin. At conversion, the parameters and setpoints maintain their numerical value and adjustment range. (Example: A controller with the desired value of C is switched to Fahrenheit. The new desired value is then interpreted as F, which corresponds to a temperature of -18 C). NOTE: Indication limits with F can be smaller than the actual measuring range! A11: Display mode The value can be indicated with or without decimal point and with or without leading zeros. A12: Alarm mode The alarm exit evaluates an upper and a lower limit value, whereas a selection is possible as to whether the alarm is a boundary or a range alarm. In case of sensor error the following applies: at boundary alarm the relay is on and at range alarm the relay is off. A13: Activation of the alarm The alarm can be deactivated. If activated a flashing display can be set. A19: Parameter lock This parameter enables locking of each parameter level. If third level is locked, only parameter A19 may be changed. A2: Minimum action time contact K1 "On" A21: Minimum action time contact K2 "On" A22: Minimum action time contact K3 "On" A23: Minimum action time contact K4 "On" These parameters permit a delay in switching off the relay in order to reduce the switching frequency. The adjusted time sets the entire minimum time period for a switched-on phase. Note: all delays are even effective after switching mains on, after an external error message or after the elimination of sensor errors. If available the Call-LED C flashes during the period where the output contacts are suppressed by the adjusted minimum action time.

A24: Minimum action time contact K1 "Off" A25: Minimum action time contact K2 "Off " A26: Minimum action time contact K3 "Off " A27: Minimum action time contact K4 "Off " These parameters permit a delay in switching on the relay in order to reduce the switching frequency. The adjusted time sets the entire minimum time period for a switched-off phase. Caution: Parameters A3, A4, A7, A8, A22, A23, A26 und A27 are only effective if the corresponding output exists and is activated with A44. A3: Mutual delay of contacts This parameter makes a mutual switching-on delay of relays possible, depending on whichever contact is switched first. It ensures that two output contacts do not switch simultaneously. The mutual delay affects no free contacts that are not involved in the load replacement. With A44= the delay is always effective. A31: Delay after Power-on This parameter allows a switching-on delay of relays after switching-on the mains voltage. This delay corresponds with the time set here. A mutual delay set by parameter A3 becomes effective as soon as the first contact is switched on. A32: Alarm suppression after "Power-On" This parameter allows a switching-on delay of the alarm contact after switching on the mains voltage. This delay corresponds with the time set here. This suppression does not apply to sensor error alarm or, if activated, external alarms. A33: Operating time before time depending load replacement Load replacement depending on time is mainly used in the field of refrigeration technology to balance the use of the connected compressors. If only some of the outputs are continuously active, outputs that have not yet been activated will be used. This parameter determines the time to elapse before outputs are changed for the first time. If available the Replace-LED R lights up as soon as the first replacement occurs and signals the continuous operation of some of the outputs in power stages below 1%. The LED goes out if power stage % or 1% is reached and no more load replacement is possible. A34: Operating time range If operating mode with time-dependent load replacement is activated these time ranges are available for parameter A33. A4: Activation of time-dependent load replacement This parameter either activates or deactivates time-dependent load replacement to balance the use of the connected compressors. The replacement takes place after the operating time set with parameter A33. A41: Sequential operation mode This parameter either activates or deactivates the sequential operation mode. If this mode is activated different compressors will be activated or deactivated (if possible) at each change of output stage to ensure an even load of the compressors. Concerning the switching of the compressors the following applies: It several compressors are activated the first started unit will be deactivated first. It several units are deactivated the first stopped unit will be activated first. Note: The time-dependent load replacement and the sequential operation mode only make sense if there is a control circuit with several components of the same power.

A42: Interlocking of total operating times This parameter releases the locking of the total operating times in parameters P33-P4. The adjustment of time values resulting from time registration is only necessary for updating purposes when plant components are replaces. A43: Adjustment of setpoint S1 (not available on all types of controllers) By closing switching input E1, setpoint S1 can be switched to a setpoint S1. Setpoint S1 can be either relative to setpoint S1 or an independent, freely adjustable, control. The setpoint S1 can only be accessed if input E1 is closed. If setpoint S1 is deactivated and the switching input is closed, the display indicates FEH or FEHL and the output relays fall back in the condition set with parameters A5-A8. This does not effect an alarm output. A44: Operation mode The control program is intended for a maximum of four regulating output contacts plus one alarm contact. In this case 5 power stages with %, 25%, 5%, 75% and 1% are available. If less output contacts are available the operation mode can be adjusted with this parameter, namely for four power stages with %. 33%, 66% and 1% or for three power stages with %, 5% and 1% (with additional alarm contact each). A change of the operation mode may also be considered if the system has to be operated with a different number of controlling components. The contact following the last controlling output is always the alarm contact.

Status messages Message Cause Error elimination F1H Sensor error, open circuit Check sensor F1L Sensor error, short circuit Check sensor FEHL Closed switching input while setpoint S1 is deactivated _ Key lock see parameter P19 and/or A19 Flashing Temperature alarm display EP Data loss at parameter memory If error cannot be eliminated by switching on/off, the controller must be repaired LED "C" flashes during a minimum action time, if a switching request is executed. Example: A2=2, K1 is switched on, LED C flashes for 2 seconds.. LED "R" LED "S" flashes as soon as the first compressor is replaced in sequential operation mode. As a compressor replacement occurs only in partial load operation (25%-75%) the LED don t flash in power stage % and 1%. lights up if the switching input is closed. Depending on parameter A43 it has different functions: A43=: alarm function A43=1 or A43=2: if switching input is closed, a new main setpoint is effective that can be adjusted by the SET key. The LED lights up if the switching input is closed and also enabled with parameter A43=1 or 2.

Technical data of ST96-35.16 Input E1: External potential-free switching contact Measuring input F1: Resistance thermometer Pt1-3L Measuring range: -99 C...3 C Measuring accuracy:.5k +/-.5 % of scale range, without sensor Outputs K1: Relay, normally-open contact, 3(1)A 25V K2: Relay, normally-open contact, 3(1)A 25V K3: Relay, normally-open contact, 3(1)A 25V K4: Relay, normally-open contact, 3(1)A 25V K5: Relay, normally-open contact, 1A 24V Display One 3-digit LED-Display, height 13mm, for temperature display, colour red One 4-digit LED-Display, height 1 mm, colour red 7 LEDs, diameter 3mm, for status display Power supply 23V 5/6Hz Ambient conditions: Storage temperature: Operating temperature: Relative humidity: -2...+7 C...+55 C max. 75% without dew Weight ca. 2g, without sensor Connectors Plug and socket for cable up to 1.5 mm² Enclosure IP63 Installation data Unit is to be installed in an instrument panel. Front size: 96 x 96 mm Panel cut-out: 9.5 x 9.5 mm Installation depth: ca. 15 mm with connector Order No.: 152652