USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Similar documents
RUNNER 8/64. 8/64 Zones Control Panel. Program Summary Guide

CC408. Quick Reference Guide Solution 880

CC488. Quick Reference Guide Solution Ultima 880

Quick Programmer s Manual

16 ( Ver: Installation & Programming Guide. Power Wave 16 Zone Control Communicator. Crow Electronic Engineering (Australia) Pty Ltd

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

Power Wave Zone Alarm Panel V8.5. Installation Manual

Solution 862 Installation Manual ISSUE 1.30

Control/Communicator Installation Manual

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Version 1.03 January-2002 USER S MANUAL

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Installation & Programming Guide

CHEAT SHEET: SPECTRA V2.1

Elite Version. 8 Zone Control Communicator. Installation & Programming Guide. Proudly Designed and Manufactured in New Zealand

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

NESS 5000 SERIES DIALLER

SPECTRA 1728, 1738 CHEAT SHEET:

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Property of Monitronics Inc

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Training Manual Multi-Language with Wireless

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Property of Monitronics Inc

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

AXI LED USER MANUAL (REV. 1.0)

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

Solution Ultima 862 Operators Manual ISSUE 1.10

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

Installation & Programming Guide. ELITE S LITE Version. (8/16 Zone Control Communicator) Arrowhead Alarm Products Ltd

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Solution Ultima Series Operators Manual ISSUE 1.00

First Alert 1200C Installer Notes M. Leuck

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

INSTALLATION MANUAL & PROGRAM RECORD SHEET


Solution 880 Operators Manual. Issue 1.00

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

Solution 844 Operators Manual ISSUE 1.10

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

Proudly Designed and Manufactured in New Zealand. By Arrowhead Alarm Products Ltd

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1

4-PGM Expansion Module

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

HILLS Series LED Code Pad User Manual

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

NESS D8 CONTROL PANEL AND DIALLER

BURGLAR ALARM PANEL BS-468

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Radionics D4112 Program Sheet

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

(Updated Defaults) (Covers Ver: 8.64 and above)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Powerwave Series. Technical Manual

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

2000 Series. Program Entry Guide. Control Panels

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

System Introduction. 1.1 Specifications

Series. NX-4-EUR Control Panel. Installation manual

ATS2000/3000/4000/4500 Control Panel. Programming guide

User's MANUAL A$ Rev 1.4

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

8-zone Expansion Module

Contents. Glossary

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Destiny Destiny Owners Manual

Programming Worksheets

Solution 6+6 Wireless - AE Operators Manual ISSUE 1.10

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

SCORPION Z16040C, Z8040C and Z5120C

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

P Zone Expandable Hybrid Security System

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

Transcription:

User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0 User 7 7 31 55 79 0 User 8 8 32 56 80 0 User 9 9 33 57 81 0 User 10 10 34 58 82 0 User 11 11 35 59 83 0 User 12 12 36 60 84 0 User 13 13 37 61 85 0 User 14 14 38 62 86 0 User 15 15 39 63 87 0 User 16 16 40 64 88 0 User 17 17 41 65 89 0 User 18 18 42 66 90 0 User 19 19 43 67 91 0 User 20 20 44 68 92 0 User 21 21 45 69 93 0 User 22 22 46 70 94 0 User 23 23 47 71 95 0 User 24 24 48 72 96 0 Installer Code 99 0 0 0 0 0 0 Duress Digit (Area A) 197 0 Duress Digit (Area B) 297 0 Duress Digit (Area B) 397 0 USER CODES Area 'A' Area 'B' Area 'C' ARM Disarm in this Manual belongs to Crow Australia P/L. Written permission must be obtained from the directors of Crow Australia P/L before this Manual is reproduced in any way in whole or part. This Manual may not be stored in any electronic or other form without the written permission of the directors of Crow Australia P/L. STAY Arm (if code needed) STAY Disarm Can operate 'Control' Can override DOTL Change Phone Numbers Change Clock Start a Printout Answer call for Upload Change Your Code Only Change all Codes Access to Programming Time Zone 1-8

Zones are N/O Wireless Detector Zone Area 'A' Area 'B' Zone is bypassable Zone Options Entry Delay - Sec 331 Zone 1 401 20 332 Zone 2 402 20 333 Zone 3 403 0 334 Zone 4 404 0 335 Zone 5 405 0 Handover (requires an Entry Delay to work) Pulse Count 24 Hour Zone On in STAY Mode Chime when Disarmed Swinger Shutdown Auto Isolate Access Control Door Position Input* Access Control Request to Exit Input* Chime Zone only Send Multiple Alarms to C.S. 336 Zone 6 406 0 337 Zone 7 407 0 338 Zone 8 408 0 339 340 341 342 343 344 345 346 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 *Access Control allowed when AREA 'A' is Armed 199 x x x x x x x Turn Option 8 ON *Access Control allowed when AREA 'B' is Armed 299 x x x x x x x Turn Option 8 ON *Access Control allowed when AREA 'C' is Armed 399 x x x x x x x Turn Option 8 ON ZONES 1-8

Zones are N/O Wireless Detector Zone Area 'A' Area 'B' Zone is bypassable Zone Options Entry Delay - Sec 351 Zone 9 409 0 352 Zone 10 410 0 353 Zone 11 411 0 354 Zone 12 412 0 355 Zone 13 413 0 Handover (requires an Entry Delay to work) Pulse Count 24 Hour Zone On in STAY Mode Chime when Disarmed Swinger Shutdown Auto Isolate Access Control Door Position Input* Access Control Request to Exit Input* Chime Zone only Send Multiple Alarms to C.S. 356 Zone 14 414 0 357 Zone 15 415 0 358 Zone 16 416 0 359 360 361 362 363 364 365 366 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 *Access Control allowed when AREA 'A' is Armed 199 x x x x x x x Turn Option 8 ON *Access Control allowed when AREA 'B' is Armed 299 x x x x x x x Turn Option 8 ON *Access Control allowed when AREA 'C' is Armed 399 x x x x x x x Turn Option 8 ON ZONES 9-16

Miscallaneous Panel Tamper/Keyswitch Input Area 'A' Pulse Count 451 60 Tamper/Keyswitch Zone 201 Area 'B' Pulse Count 452 60 Area 'C' Pulse Count 453 60 Zone Response Time 709 6 270ms (1-32 in 45ms increments) Zone Doubling 300 Area 'A' 180 Area 'B' 280 Area 'C' 380 Keyswitch Zone Area 'A' 199 Keyswitch Zone Area 'B' 299 Keyswitch Zone Area 'C' 399 Disable STAY Exit Delay Disable Arm Exit Delay Key Switch Enabled Input 1 is Zone Doubled Input 2 is Zone Doubled Input 3 is Zone Doubled Input 4 is Zone Doubled Disable STAY Entry Delay Input 5 is Zone Doubled Disable Arm Entry Delay Spare Disable Zone Tampers in Exit Delay Double EOL for 2nd K/Switch STAY Arm/Disarm = Off Input 6 is Zone Doubled Input 7 is Zone Doubled Input 8 is Zone Doubled Seconds Low Keyswitch is Momentary/Latching High Keyswitch is Momentary/Latching N/C or EOL ZONES/Partition Misc.

AREA 'A' AREA 'B' AREA 'C' Output 1 171 271 371 Output 2 172 272 372 Output 3 173 273 373 Output 4 174 274 374 Output 5 175 275 375 Output 6 176 276 376 Output 7 177 277 377 Output 8 178 278 378 Output 1 181 281 381 Output 2 182 282 382 Output 3 183 283 383 Output 4 184 284 384 Output 5 185 285 385 Output 6 186 286 386 Output 7 187 287 387 Output 8 188 288 388 Exit Beeps Control Button Arm/Disarm STAYArm/Disarm Duress Code Zones isolated Auto Isolate Warning Entry Beeps Smoke Reset Pulse on Arm Chime Zone Zone Alarms 24 Hour Alarms STAY Mode Alarms Arm/Disarm STAYArm/Disarm Exit Beeps Control Button Arm/Disarm STAY Arm/Disarm Duress Code Zones isolated Auto Isolate Warning 24 Hour Alarms Entry Beeps Exit Beeps Control Button Zone Alarms 24 Hour Alarms 2 Sec Arm/Disarm Pulse Duress Code 2 Sec Arm/Disarm Pulse Smoke Reset Pulse on Arm Chime Zone Zones isolated Auto Isolate Warning Entry Beeps STAY Mode Alarms Zones Sealed (Ready) 2 Sec Arm/Disarm Pulse Zones Sealed (Ready) Smoke Reset Pulse on Arm Chime Zone Zone Alarms STAY Mode Alarms Zones Sealed (Ready) OUTPUTS

24 Hour Events to Output State Pulse Time Reset Time Delay on Time Output 1 111 101 441 0 421 600 431 0 Output 2 112 102 442 0 422 600 432 0 Output 3 113 103 443 0 423 600 433 0 Output 4 114 104 444 0 424 600 434 0 Output 5 115 105 445 0 425 0 435 0 Output 6 116 106 446 0 426 0 436 0 Output 7 117 107 447 0 427 0 437 0 Output 8 118 108 448 0 428 0 438 0 Keypad Panic Keypad Tamper (wrong code) Zone Tampers System Tamper R/C Panic Mains Fail Battery Low Phoneline Failure Invert Output Pulsing Single Pulse One Shot (lockout) DTMF Phone Control Keypad "Control" button Chime zones via pulse timer Pulse output for 24 Hour Alarm 1/10 Second 1-999 Seconds 1-999 Seconds Area Pulses Chime Zone Duration Area 'A' to Addr 171-178 opt.6 199 457 2 Seconds Area 'B' to Addr 271-278 opt.6 299 458 2 Seconds Area 'C' to Addr 371-378 opt.6 399 459 2 Seconds OUTPUTS 2 2 Sec Arm pulse 2 Sec Disarm Pulse

Keypad Options Chime Mode Timer Exit Delay Keypad Area Area 'A' 198 457 2 417 60 140 Area 'B' 298 458 2 418 60 141 Area 'C' 398 459 2 419 60 142 Spare ARM Button before Code to set STAY Button before Code to set Disable ARM Button Code required for 'Control' key Control' toggles O/P via reset timer Control' to O/P via pulse timer Control key disables Chime Zones 1-999 Seconds 0-999 Seconds Keypad 1 Keypad 2 Keypad 3 Keypad 4 Keypad 5 Keypad 6 Keypad 7 Keypad 8 Keypad Panics ing Keypads Output 1 111 Output 2 112 Output 3 113 Output 4 114 Output 5 115 Output 6 116 Output 7 117 Output 8 118 Keypad Panic Wrong Code Alm KEYPADS

AREA 'A' AREA 'B' AREA 'C' Arm Key Disarms during Exit Delay 189 289 389 Monitor Key can Disarm Monitor Mode 190 290 390 Chime Mode Beeps 191 291 391 Zone Alarms operates Buzzer 192 292 392 Zone 'Monitor' Alarms operates Buzzer 193 293 393 24 Hour Alarms operates Buzzer 194 294 394 Exit Beeps 195 295 395 Entry Beeps 196 296 396 Keypad 1 Keypad 2 Keypad 3 Keypad 4 Keypad 5 Keypad 6 Keypad 7 Keypad 8 Keypad 1 Keypad 2 Keypad 3 Keypad 4 Keypad 5 Keypad 6 Keypad 7 Keypad 8 Keypad 1 Keypad 2 Keypad 3 Keypad 4 Keypad 5 Keypad 6 Keypad 7 Keypad 8 Can Arm Can go into 'STAY' Mode Can use 'Control' Key Can Bypass Zones Can Listen-in to Phoneline Can enter Master Code Programming Can enter Installer Programming Turns Off LED's after Exit Delay Keypad Tamper operates Buzzer Zone Tamper operates Buzzer Cabinet Tamper operates Buzzer Panic Button Enabled Keypad Panic operates Buzzer Phoneline Failure Operates Buzzer 143 144 145 146 147 148 149 152 153 154 155 156 157 158 KEYPADS 2 Keypad 1 Keypad 2 Keypad 3 Keypad 4 Keypad 5 Keypad 6 Keypad 7 Keypad 8

Day of Week ON Time OFF Time Time Zone 1 681 682 0000-2359 683 0000-2359 Time Zone 2 684 685 0000-2359 686 0000-2359 Time Zone 3 687 688 0000-2359 689 0000-2359 Time Zone 4 690 691 0000-2359 692 0000-2359 Time Zone 5 693 694 0000-2359 695 0000-2359 Time Zone 6 696 697 0000-2359 698 0000-2359 Time Zone 7 699 700 0000-2359 701 0000-2359 Time Zone 8 702 703 0000-2359 704 0000-2359 Sunday Monday Tuesday Wednesday Thursday Friday Saturday Invert TZ Enable/Disable TZ Output 1 131 121 O/P Auto ON/OFF Output 2 132 122 AREA Auto-Arm Output 3 133 123 Area 'A' 170 180 Output 4 134 124 Area 'B' 270 280 Output 5 135 125 Area 'C' 370 380 Output 6 136 126 Output 7 137 127 Output 8 138 128 TIME ZONES TZ 1 TZ 2 TZ 3 TZ 4 TZ 5 TZ 6 TZ 7 TZ 8 TZ 1 TZ 2 TZ 3 TZ 4 TZ 5 TZ 6 TZ 7 TZ 8 TZ 1 TZ 2 TZ 3 TZ 4 TZ 5 TZ 6 TZ 7 TZ 8 Arm when TZ ends Disarm when TZ Starts

Enabling Wireless Zones Enable 332 352 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 Wireless Detector Learning Wireless Detector Types Zone 1 501 Learn Mode 521 0 Zone 2 502 Learn Mode 522 0 Zone 3 503 Learn Mode 523 0 Zone 4 504 Learn Mode 524 0 0 27MHz Transmitters Zone 5 505 Learn Mode 525 0 1 Ness Wireless devices Battery Low Zone 6 506 Learn Mode 526 0 2 Ness Wireless Reed Switch Zone 7 507 Learn Mode 527 0 3 Crow Wireless PIR Battery Low Zone 8 508 Learn Mode 528 0 4 Visonic K900 Radio PIR Zone 9 509 Learn Mode 529 0 5 Electronics Line Cougar Radio PIR Zone 10 510 Learn Mode 530 0 6 Crow Wireless Reed Switch Zone 11 511 Learn Mode 531 0 7 Spare Zone 12 512 Learn Mode 532 0 8 Spare Zone 13 513 Learn Mode 533 0 Zone 14 514 Learn Mode 534 0 Zone 15 515 Learn Mode 535 0 Zone 16 516 Learn Mode 536 0 WIRELESS DETECTORS

Remote Control Learning Arm/Disarm Options Output Options Buttons to Outputs Button 1 541 Press Button to Learn 561 581 601 Button 2 542 Press Button to Learn 562 582 602 Button 3 543 Press Button to Learn 563 583 603 Button 4 544 Press Button to Learn 564 584 604 Button 5 545 Press Button to Learn 565 585 605 Button 6 546 Press Button to Learn 566 586 606 Button 7 547 Press Button to Learn 567 587 607 Button 8 548 Press Button to Learn 568 588 608 Button 9 549 Press Button to Learn 569 589 609 Button 10 550 Press Button to Learn 570 590 610 Button 11 551 Press Button to Learn 571 591 611 Button 12 552 Press Button to Learn 572 592 612 Button 13 553 Press Button to Learn 573 593 613 Button 14 554 Press Button to Learn 574 594 614 Button 15 555 Press Button to Learn 575 595 615 Button 16 556 Press Button to Learn 576 596 616 REMOTE CONTROLS 1 Area 'A' Area 'B' Area 'C' Can Arm Can Disarm STAY Mode On STAY Mode Off Disabled In Alarm Turn 'Control' ON Turn 'Control' OFF Turn Output ON Turn Output OFF Spare Hold Down button 'Panic' Immediate Hold Down 'Panic' 1.5sec Delay Ness 24hr Battery Low Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8

AREA 'A' AREA 'B' Panic to O/P Chirps to O/P Chirps to O/P Output 1 111 171 271 371 AREA 'C' Chirps to O/P Output 2 112 172 272 372 Output 3 113 173 273 373 Output 4 114 174 274 374 Output 5 115 175 275 375 Output 6 116 176 276 376 Output 7 117 177 277 377 Output 8 118 178 278 378 R/C Panic to Output R/C Chirps R/C Chirps R/C Chirps Area 'A' 199 Area 'B' 299 Area 'C' 399 Chirps when armed Chirps if 'STAY' armed REMOTE CONTROLS 2

Account Numbers Area Dialling Scenarios Area Reporting Options Area 'A' Account # 266 0 0 0 0 323 322 Area 'B' Account # 267 0 0 0 0 325 324 Area 'A' Account # 268 0 0 0 0 327 326 Scenario 1 Scenario 2 Scenario 3 Scenario 4 Telephone Numbers Dialling Protocols Telephone #1 Telephone #2 Telephone #3 221 222 223 16 Digits 16 Digits 16 Digits 231 232 233 Send Open/Close Send Monitor Open/Close Send Open After Alarm Send Duress Alarms 24Hr Alarms to Voice/Domestic Send Open Immediately Telephone #4 224 16 Digits 234 Telephone #5 225 16 Digits 235 Telephone #6 Dialling Scenarios Dialling Attempts Dialling Scenarios Key Dialling Scenario #1 211 1,7 (Monitoring) 215 10 1 = Dial Telephone #1 2 = Dial Telephone #2 Dialling Scenario #2 212 216 10 3 = Dial Telephone #3 4 = Dial Telephone #4 Dialling Scenario #3 213 217 10 5 = Dial Telephone #5 6 = Dial Telephone #6 Dialling Scenario #4 214 218 10 7 = Return to step 1 until all numbers kissed off 8 = Return to previous step if not kissed off 9 = Stop if kissed off 0 = Stop whether kissed of or not DIALLER 226 16 Digits 236 Contact ID Domestic Pager Voice Spare 0-99 Detect busy Tone Spare Spare

General Options Contact ID Codes Test Call Hour/Minute 707 2300 (0-2359) Zone 1 621 130 Zone 1 S/C Tamper 641 137 Test Call Days of Week 706 (Mon - Sun) Zone 2 622 130 Zone 2 S/C Tamper Auto Answer Ring Count 329 25 (0-99) Zone 3 623 130 Zone 3 S/C Tamper Mains Fail Report Delay 460 600 (0-999 Seconds) Zone 4 624 130 Zone 4 S/C Tamper Upload/Download Panel Code 718 8 Digits Zone 5 625 130 Zone 5 S/C Tamper 642 643 644 645 137 137 137 137 Report Delay on Zone Alarms 450 0 (0-999 Seconds) Zone 6 626 130 Zone 6 S/C Tamper 646 137 Zones 1-8 Dial multiple alarms 346 Zone 7 627 130 Zone 7 S/C Tamper Zones 9-16 Dial multiple alarms 366 Zone 8 628 130 Zone 8 S/C Tamper 647 648 137 137 Dialler Options 260 Zone 9 629 130 Zone 1 O/C Tamper Dialer ON DTMF or Decadic NZ Decadic Blind Dial Send Restores Send Group # or separate Acct # Double Call Disable Line Monitoring Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 630 631 632 633 130 Zone 2 O/C Tamper 130 Zone 3 O/C Tamper 130 Zone 4 O/C Tamper 130 Zone 5 O/C Tamper 651 137 651 137 651 137 651 137 651 137 634 130 Zone 6 O/C Tamper 651 137 635 130 Zone 7 O/C Tamper 651 137 Upload/Download Options 719 Zone 16 636 130 Zone 8 O/C Tamper DIALLER Misc. Data Transfer allowed Can get Data from Panel Can Send Data to Panel Can see Keypad Activity Can see Panel Status Can Change Panel Status Can Clear Event Buffer V.21 or Bell 103(off) Duress 620 121 651 137

Zone Alarms Dialling Scenarios Zone Exclude Dialling Scenarios Zone Tamper Dialling Scenarios System Dialling Scenarios Zone 1 Alarms 241 Zone 1 Exclude 461 Zone 1 S/C Tamper 481 Keypad Panic 311 Zone 2 Alarms 242 Zone 2 Exclude 462 Zone 2 S/C Tamper 482 Battery Low 312 Zone 3 Alarms 243 Zone 3 Exclude 463 Zone 3 S/C Tamper 483 Mains Fail 313 Zone 4 Alarms 244 Zone 4 Exclude 464 Zone 4 S/C Tamper 484 Phone Line Restore 314 Zone 5 Alarms 245 Zone 5 Exclude 465 Zone 5 S/C Tamper 485 Radio PIR Batt Low 315 Zone 6 Alarms 246 Zone 6 Exclude 466 Zone 6 S/C Tamper 486 R/C Battery Low 316 Zone 7 Alarms 247 Zone 7 Exclude 467 Zone 7 S/C Tamper 487 Keypad Tamper 317 Zone 8 Alarms 248 Zone 8 Exclude 468 Zone 8 S/C Tamper 488 Cabinet Tamper 318 Zone 9 Alarms 249 Zone 9 Exclude 469 Zone 1 O/C Tamper 491 R/C Panic 319 Zone 10 Alarms 250 Zone 10 Exclude 470 Zone 2 O/C Tamper 492 Test Calls 320 Zone 11 Alarms 251 Zone 11 Exclude 471 Zone 3 O/C Tamper 493 Zone 12 Alarms 252 Zone 12 Exclude 472 Zone 4 O/C Tamper 494 Zone 13 Alarms 253 Zone 13 Exclude 473 Zone 5 O/C Tamper 495 Zone 14 Alarms 254 Zone 14 Exclude 474 Zone 6 O/C Tamper 496 Zone 15 Alarms 255 Zone 15 Exclude 475 Zone 7 O/C Tamper 497 Zone 16 Alarms 256 Zone 16 Exclude 476 Zone 8 O/C Tamper 498 Scenario 1 Scenario 2 Scenario 3 Scenario 4 Scenario 1 Scenario 2 Scenario 3 Scenario 4 Scenario 1 Scenario 2 Scenario 3 Scenario 4 Scenario 1 Scenario 2 Scenario 3 Scenario 4 DIALLER Alarm Mapping

Miscellaneous Setting Clock System 201 Hour/Minute 731 0-2359 Clear Memory 745 Mains input AC or DC Ignore Mains Fail Installer Lockout Area 'C' is Common Area Serial Port is 9600 or 2400Bps Day 730 1=Sun 2=Mon 3=Tue 4=Wed 5=Thu 6=Fri 7=Sat Walk Test 735 Date 732 1 to 31 Start Event Printing 726 Month 733 1 to 12 Clear all output parameters 740 Year 734 0-99 Answer Incoming Call 728 Daylight Saving 712-717 Preset - See P38 of Manual Manufacture Date 747-749 View Active Time Zones Viewing System Parameters 720 Read/Write to Programming Chip Write to Chip 736 Daylight Saving Active (8=on) 721 Read from Chip 738 Display Current Keypad 723 1-8 Display current Keypad Partition 724 A, B, C Defaulting Panel Default User Codes 741 Phoneline Listen-in options Keypad 727 Default Dialler Default Wireless es Default All Other es MISCELLANEOUS 742 743 744 Only while Dialling During Entire Call At all times

Alarms to Voice Messages Panic to Voice Message # 660 Voice Messages 1-8 Zone 1 to Voice Message # 661 Voice Messages 1-8 Zone 2 to Voice Message # 662 Voice Messages 1-8 Zone 3 to Voice Message # 663 Voice Messages 1-8 Zone 4 to Voice Message # 664 Voice Messages 1-8 Zone 5 to Voice Message # 665 Voice Messages 1-8 Zone 6 to Voice Message # 666 Voice Messages 1-8 Zone 7 to Voice Message # 667 Voice Messages 1-8 Zone 8 to Voice Message # 668 Voice Messages 1-8 Zone 9 to Voice Message # 669 Voice Messages 1-8 Zone 10 to Voice Message # 670 Voice Messages 1-8 Zone 11 to Voice Message # 671 Voice Messages 1-8 Zone 12 to Voice Message # 672 Voice Messages 1-8 Zone 13 to Voice Message # 673 Voice Messages 1-8 Zone 14 to Voice Message # 674 Voice Messages 1-8 Zone 15 to Voice Message # 675 Voice Messages 1-8 Zone 16 to Voice Message # 676 Voice Messages 1-8 Battery Low to Voice Message # 679 Voice Messages 1-8 ('0' at any of these addresses stops any dialling attempts) SPEECH DIALLER Programming