Split Air Conditioner

Similar documents
Split Air Conditioner

Split Air Conditioner

GENERAL INFORMATION CONTENTS

Split Air Conditioner. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Split Air Conditioner

Owner s Manual Window Air Conditioner

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Choosing the installation site. Installation. 07 Choosing the installation site

OWNER S MANUAL ASH-09CS ASH-12CS SLIM SERIE. Before operating the unit please carefully read this manual.

Split Air Conditioner

Owner s Manual. Wall Mounted Unit. Models LIMI-12 / LIMO-12 LIMI-18 / LIMO-18 LIMI-24 / LIMO-24

AMTCM4H4R24 AMTCM4H4R30 AMTCM4H4R36

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

ALICE HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

OWNER S MANUAL. Split Air Conditioner IAPH301A / OAPH301A IAPH361A / OAPH361A

Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC

Split Air Conditioner

IOM & Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Split Air Conditioner. Model: GSA609AE GSA609AC GSA612AE GSA612AC GSA618AE GSA618AC GSA624AE GSA624AC

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

CCH mini-splits -13 SEER

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

USER'S MANUAL CAESARE SERIES ASH-28AC

Split Air Conditioner

INVERTER SPLIT - TYPE

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

AIR CONDITIONER CONSOLE

36,000 Btu/hr Mini Split Air Conditioner

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Saunier Duval Clima, S.A.

Notices for installation

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

ROOM AIR CONDITIONER INSTALLATION MANUAL

Bosch Split-Type Ductless Air Conditioner / Heat Pump

DAIKIN AIR CONDITIONER

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

Split Portable Air Conditioner

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

PORTABLE AIR CONDITIONER OWNER S MANUAL

Refrigerated Compressed Air Dryer

Split Air Conditioner

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

OWNER S MANUAL. Split Air Conditioner AIR-MASTER Series MODELS: CH-S07RX4 CH-S09RX4 CH-S12RX4 CH-S18RX4 CH-S24RX4

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

KSD-35 DR11 KUE-35 DVN11

Split Air Conditioner

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

INSTALLATION MANUAL. R410A Split Series. Model RXS24LVJU. Installation manual R410A Split series. Manual de instalación Serie Split R410A.

PORTABLE AIR CONDITIONER OWNER S MANUAL

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Installation Instructions

OPERATION MANUAL AND INSTALLATION MANUAL

Saunier Duval Clima, S.A.

NEXXOS INVERTER USER MANUAL

XIDEKO AIR CONDITIONERS

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

USER MANUAL WATER DISPENSER WITH ICE MAKER

Split Air Conditioner

PORTABLE AIR CONDITIONER

SYSTEM Inverter Air Conditioners

Owner s Manual Super-Slim Four-Way Cassette

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Flex Match Series System-Outdoor Unit

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

Horizontal/Side Discharge Condensing Units

[FLARE CONNECTION TYPE] ATTENTION

Safety Precautions (1)

GS-1. Instruction Manual. G-Series Cooler. Manual is for the following models: GS-1-N14NF GS-1-N14NG GS-1-N14NI COUNTERTOP COOLER

Split Air Conditioner

BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS

Inverter Split-type Room Air Conditioner

Instruction Manual. Chest Freezer Model: CF.142L

SPLIT WALL-MOUNTED AIR CONDITIONER

AY-AP09DJ SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL AE-A09DJ AY-AP09DJ OUTDOOR UNIT INDOOR UNIT

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

CENTRAL AIR CONDITIONER SPLIT SYSTEM

SPLIT -TYPE ROOM AIR CONDITIONER

AIR CONDITIONER FLOOR CEILING

SPLIT TYPE. Instruction manual

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

USER MANUAL AND INSTALLATION MANUAL

Wall Mounted Mini Split Heat Pump Air Conditioner

Installation manual for room air conditioner

Transcription:

Split Air Conditioner Owner's Manual Residential Air Conditioners Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future reference.

CONTENTS Operation and maintenance Notices for operation...1 Names of each part...3 Clean and care...4 Installation service Notices for installation...5 Installation dimension diagram...7 Install outdoor unit...8 Testing operation and check after installation...10 This symbol stands for the items should be forbidden. This symbol stands for the items should be followed. Thank you for choosing Air-con split type air conditioner. For correct operation, please keep this manual well for future reference. The graphs in this manual may be different from the actual product, please refer to the actual product.

Notices for operation Please read the following notices carefully before operation. When there is an abnormal phenomenon (such as burning smell), please turn off the power supply and then contact Air-con appointed maintenance center. Caution Never operate the unit with wet hands. Never destroy or cut the power cord. If the power cord is found to be broken, please ask a professional to repair. If the abnormal phenomenon is not eliminated in time, the unit may be damaged and may cause electric shock or fire hazards. Please use professional wire in order to prevent fire hazards. Otherwise, it may cause electric shock. Fluctuation of voltage in a certain range is allowed. Over-high voltage may stimulate the breakage of electric elements. Over-low voltage may stimulate vibration of compressor which will lead to breakage of the system. Never destroy the wire or use the wire with different specification. For the wire connection of function socket or movable socket, please do not use multifunctional socket or movable socket. Otherwise, it may cause electric shock or fire hazards. Turn off the unit and cut off the power supply before cleaning the unit in order to prevent electric shock or injury. Cut off power supply - 1 -

Notices for operation Ground connection: connect to the ground reliably! Grounding wire should be connected to the appropriative grounding device of the building. Be sure to cut off the power supply when you don t use the air conditioner for a long time. Otherwise, the dusts may accumulate on it, which may cause overheating or fire hazards. Keep flammable spray and gas jar away from the outdoor unit for more than 1m. Otherwise, it may cause fire hazard or explosion. If the appropriative grounding device is not available, please ask a professional to install. Never connect the grounding wire to gas pipe, tap water pipe, blowdown pipe or other unreliable places considered by a professional. Pay attention to check if the installation rack of outdoor is broken. If the broken rack is not repaired in time, the unit may fall down and cause injury. Never stand on the outdoor unit or place objects on it. Person or objects falling from the unit may cause injury. Don t attempt to repair the air conditioner by yourself. Wrong repair may cause electric shock or fire hazard, so you should contact the appointed maintenance center to repair. - 2 -

Names of each part Outdoor unit Air in (1) power connection wire (2) Drainage pipe (1) (2) Air out - 3 -

Clean and care Caution Turn off the unit and cut off the power supply before cleaning. Or it may cause electric shock. Never wash the air conditioner with water because it can cause an electric shock. Volatile liquid (e.g. dilution agent or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth or a cloth moistened with neutral detergent.) Check before use 1 Be sure that nothing obstructs the air inlet and outlet of outdoor unit. 2 Check whether the grounding wire is properly connected. 3 Check whether the installation rack of the outdoor unit is broken or not. If broken, please contact the Air-con appointed maintenance center. If the outdoor unit is rusty, please paint the rusty place to prevent spreading. 1 Power off the unit. Maintain after use 2 Clean the filter and indoor and outdoor units' bodies. 3 Clean the dusts and foreign objects of outdoor unit. 4 Check whether the installation rack of the outdoor unit is broken or not. If broken, please contact the Air-con appointed maintenance center. If the outdoor unit is rusty, please paint the rusty place to prevent spreading. 5 You can wrap the indoor and outdoor units with special protective cover to prevent rain and dusts getting into the unit. - 4 -

Notices for installation Important notices 1. The unit installation work must be done by qualified personnel according to the local rules and this manual. 2. Contact Air-con appointed maintenance center before installation. If the unit is not installed by Air-con appointed maintenance center, the unit may not be repaired in time when there is a malfunction. 3. When moving the unit to other place, please contact Air-conappointed maintenance center. 4. Installation must be performed in accordance with the requirements of NEC and CEC by authorized personnel only. Basic requirements for installation position Installing in the following place may cause malfunction. If it is unavoidable, please contact Air-conappointed maintenance center: 1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the air. 2. The place with high-frequency devices, such as welding machine, medical equipment, etc. 3. Place the unit near coast area. 4. The place with oil (machine oil) in the air. 5. The place with sulfured gas such as sulfured hot spring. 6. Other places with special circumstance. Outdoor unit installation location selection 1. Select a location where noise and outflow air emitted by the unit will not affect neighbors, animals or plants. 2. Select a location with sufficient ventilation. 3. Select a location without obstructions which will affect air inlet and outlet. 4. The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation. 5. Select a dry location but the unit will not be exposed under direct sunlight or strong wind. 6. Make sure that the outdoor unit installation dimension should follow installation dimension diagram for convenient maintenance. 7. The height difference of indoor and outdoor unit should be within 5m. The length of connection pipe should be within 10m. 8. Select a location which is out of reach for children. 9. Select a location where will not affect public passage and city appearance. - 5 -

Notices for installation Electric safety requirements 1. The power supply should be of rated voltage and AC exclusive circuit. The diameter of power cable should me the requirement. 2. The voltage for normal operation should within 90%~110% of 208~230V. 3. Don't pull the power cable forcibly. 4. The unit should be reliably grounded and it should be connected to the appropriative grounding device of the building. The installation work should be done by the professional. There should be sufficient electric leakage protection switch and air switch in fixed circuit. The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading. 5. The minimum distance from the unit and flammable surface is 1.5m. 6. There should be a circuit breaker in fixed circuit. The circuit breaker is with all-pole disconnection and the off-contact distance should be more than 3mm. Grounding requirements 1. Air conditioner is type I electric appliance, thus please adopt reliable grounding measures. 2. The yellow-green wire in air conditioner is grounding wire and cannot be used for other propose. It can t be cut off and be fixed by tapping screw. Otherwise it will cause electric shock. 3. The power supply must have reliable grounding terminal. Please don't connect the grounding wire to the following places: 1 gas pipe 2 tap water pipe 3 blowdown pipe 4 other unreliable places considered by a professional Others 1. The connection method of unit and power cable as well as the interconnect method of each isolated component should refer to the circuit diagram stick on the unit. 2. The model of the fuse and rated value should refer to the silk-printed indication on the controller or fuse sleeve. 3. The external static pressure in testing point should be 0MPa. - 6 -

Installation dimension diagram Installation dimension diagram Space to the obstruction 50cm above Air inlet side 30cm above 30cm above Space to the wall 200cm above Air outlet side 50cm above Space to the wall - 7 -

Install outdoor unit Electric wiring 1. Remove the cable-cross board of outdoor right side plate. 2. Put the power connection wire and power cord through the wire hole. 3. Take off the wire clamp. Connect the power connection wire and power cord to the terminal and then fix them. Wiring should be coherent with the indoor unit. 4. Fix the power connection wire and power cord with wire clamp. 5. Ensure if the wires have been fixed well. 6. Install the cable-cross board. NOTE: Wrong wiring may cause malfunction of some electrical parts. After the wire has been fixed, ensure there is frees pace between the connection and fixing places on the lead wire. for 9k 12k models Sketch map of power connection wire: N(1) 2 3 Cable-cross board L1 L2 Wire hole Power connection wire Power cord for 18K 24K models N(1) 2 3 L1 L2 G blue black brown brown blue L1 L2 Indoor unit connection POWER yellowgreen yellowgreen - 8 -

Install outdoor unit Air purging method: Air purging Air purging method Use vacuum pump Length of connection pipe Not longer than 7.5m 7.5~20m Use vacuum pump (Note: R410A refrigerant special vacuum pump should be applied for R410A unit.) 1. Connect the charging hose of manifold valve to charging port of low-pressure valve. Both high-pressure valve and low-pressure valve must be tighten up). 2. Connect joint of charging hose to vacuum pump. 3. Fully open Lo (low pressure) handle of manifold valve and start the vacuum pump for vacuum pumping. 4. Usually the vacuum pumping time of 2600W AC is about 15min. The vacuum pumping time of 5000W AC is about Gas valve Liquid valve 20min. The vacuum pumping time of 7200W AC is about 5 30min. Make sure the pressure is -1.0X10 pa (-76cmHg). When vacuum pumping is finished, close Lo (low pressure) handle of manifold valve completely to stop the vacuum pump. Refrigerant charging amount Nameplate value Nameplate value +20g/m (for 9k 12k 18k cool and heat type) Nameplate value +15g/m (for 18k 24k cool type) Nameplate value +50g/m (for 24k cool and heat type) add 15g/20g/50g of refrigerant for additional 1m of pippe length Multimeter -76cm Hg Lo handle Charging hose Manifold valve Piezometer Hi handle Charging hose Vacuum pump 5. Maintain the pressure for a while after finishing vacuum pumping to see if there is leakage of the system. Usually the pressure maintenance time of the air conditioner above 5000W is 5min and the pressure maintenance time of the air conditioner below 5000W is 3min. During pressure maintenance period, the rebound of pressure should not exceed 0.005Mpa (0.05kg). 6. After finishing vacuum pumping, open the liquid valve slightly to release air in order to balance the system pressure and present air inlet when removing the hose. Fully open high-pressure valve and low-pressure valve after removing the hose. 7. Tighten bonnets of high-pressure valve, low-pressure valve and charging port. Leakage test Apply soap water to check whether the joints are leaky. Leak detector can also be applied for leakage test. Leak detection point of indoor unit Leak detection point of outdoor unit - 9 -

Testing operation and check after installation Checking items after installation Items to be checked Possible malfunction Has it been installed firmly? Have you done the refrigerant leakage test? Is heat insulation sufficient? Is water drainage well? Is the voltage of power supply is in accordance with the rated voltage marked on the nameplate? Is the electric wiring and piping connection installed correctly? Is the unit grounded securely? Does the power cord follow the specification? Is there any obstruction in the air inlet and outlet? Have the length of connection pipe and refrigerant charging amount been recorded? The unit may drop, shake or emit noise. It may cause insufficient cooling (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water dripping. It may cause malfunction or damaging the parts. It may cause malfunction or damaging the parts. It may cause electric leakage. It may cause malfunction or damaging the parts. It may cause insufficient cooling (heating) capacity. The refrigerant charging amount is not accurate. Test operation 1. Preparation of testing operation (1) Do not switch on power before installation is finished completely. (2) Electric wiring must be connected correctly and securely. (3) Cut-off valves of the connection pipes should be opened. (4) All the impurities such as scraps and thrums must be cleared from the unit. 2. Test operation method (1) Put through the power, press ON/OFF button on the remote controller to start the operation. (2) Press MODE button to select the COOL, HEAT (not available for cooling only unit) and FAN to check whether the operation is normal or not. - 10 -

66129912626