Ardmore, PA Atlantic City, NJ REQUEST FOR INFORMATION PROJECT: 1845 - Renaissance Hotel Renovations RFI NUMBER: 110.0 JONATHAN NEHMER & ASSOC ATTN: Lauren Maccherone Dacey 7361 Calhoun Place Suite 310 Rockville, MD 20855 301-670-1635-phone 301-670-9643-fax Requested Date: Requested Contractor: Generated By: Response Due By: Response Received: E.J. Raith Mechanical Inc Kenneth Romano 11/07/2017 The required but unavailable information is resulting in a delay in fabrication of material or prosecution of the work in the field. Once the information is received we will advise you as to the impact to the schedule and cost Subject: Drain pump for bottle filler LL2 Reference: Information Requested: Per Dwg P2.1 LL2 Spa reception area (water bottle) filler. note #5 says to locate existing sanitary line, saw cut and tap. We have a better solution after reviewing the field conditions. We would like to install a drain pump and tap into the sanitary above. attached is the cut sheets of pump and location where we want to install the pump with access panel. FYI existing LL2 sinks had these pumps and hotel management is ok with the pump. Response Requested By: Response: Per Steve Derrickson and David Drake, the plumbing engineer, the alternate solution proposed by TN Ward is acceptable. Request CCs: Response CCs:
Ardmore, PA Atlantic City, NJ REQUEST FOR INFORMATION PROJECT: 1845 - Renaissance Hotel Renovations RFI NUMBER: 110.0 JONATHAN NEHMER & ASSOC ATTN: Lauren Maccherone Dacey 7361 Calhoun Place Suite 310 Rockville, MD 20855 301-670-1635-phone 301-670-9643-fax Requested Date: Requested Contractor: Generated By: Response Due By: Response Received: E.J. Raith Mechanical Inc Kenneth Romano 11/07/2017 The required but unavailable information is resulting in a delay in fabrication of material or prosecution of the work in the field. Once the information is received we will advise you as to the impact to the schedule and cost Subject: Drain pump for bottle filler LL2 Reference: Information Requested: Per Dwg P2.1 LL2 Spa reception area (water bottle) filler. note #5 says to locate existing sanitary line, saw cut and tap. We have a better solution after reviewing the field conditions. We would like to install a drain pump and tap into the sanitary above. attached is the cut sheets of pump and location where we want to install the pump with access panel. FYI existing LL2 sinks had these pumps and hotel management is ok with the pump. Response Requested By: Response: Per Steve Derrickson and David Drake, the plumbing engineer, the alternate solution proposed by TN Ward is acceptable. -Lauren Maccherone Dacey JN+A Request CCs: Response CCs:
Install new drain pump here in the wall with new access panel big enough to pull pump if needed
Model 404 Short Profile! Only 11" Tall Drain Pump Short Profile Applications Include: Bar sinks, laundry trays, dehumidifiers, utility sinks and gray wastewater drainage below gravity lines 1/3 hp 3/8" solids-handling Featuring QuickTree technology for easy switch access! Features: Factory pre-assembled, ready to install Fully automatic operation Short profile design for compact areas only 11" tall Separate access cover for easy switch inspection (QuickTree ) Integrally molded rubber gasket for a superior gas-tight seal Standard alarm and Wi-Fi alarmed models available NEW! Models Available
MODEL 404 AUTOMATIC DRAIN PUMP FEATURES: Compact design for tight areas. Factory pre-assembled. Fully automatic operation. QuickTree technology allows quick inspection and removal of float switch without disconnecting the plumbing. Integrally molded rubber gaskets for a superior gas-tight seal. Oil-filled, hermetically sealed motor with thermal-overload protection; 10 ft., 3 wire power cord with grounded plug. Corrosion-resistant polyolefin basin with molded-in connections. Maintenance-free, permanently lubricated sealed bearings. 3/8" Solids-Handling Maximum fluid temperature 104 degrees F continuous duty, 140 degrees F intermittent duty. Not intended for use with chemicals. Total Head in Feet DIMENSIONAL DATA: Weight: 13 LBS. Height: 11-1/8" Major Width: 13-3/4" Total Basin Capacity: 4.3 Gallons MOTOR SPECIFICATIONS: 1/3 hp. 60Hz 115V 3450 RPM 5.2a Oil Filled, Thermally Protected PERFORMANCE CURVE 25 20 15 10 5 0 5 10 15 20 25 30 35 U.S. Gallons Per Minute 0 28.4 56.8 85.2 113.6 Liters Per Minute 6 4 2 0 Total Head in Meters Discharge Standard Check Valve MODEL HP Volts Inlet & Vent Alarm Wi-Fi Alarm Included 404 1/3 115 1-1/2" 404CV 1/3 115 1-1/2" X 404/A 1/3 115 1-1/2" X 404CV/A 1/3 115 1-1/2" X X 404/A-EYE 1/3 115 1-1/2" X 404CV/A-EYE 1/3 115 1-1/2" X X 404L 1/3 115 2" Alarmed models come with factory mounted alarm float in system. No assembly required. See Alarm literature for ALM-2 standard alarm or NightEye Wi-Fi alarm for complete alarm specifications. 404CV models are Certified to the UPC and IPC requirements of ASME A112.3.4 / CSA B45.9 APPLICATIONS: Laundry Trays Mop Sinks Bar Sinks Water Softener Dehumidifiers Wherever gray wastewater drainage is needed below gravity lines. QuickTree technology allows easy removal of float without disconnecting plumbing or pulling the pump. Heavy-Duty integrally molded rubber gasket provides a superior seal. Meets 10 stack test requirements. PUMPS Specifications are subject to change without notice. Liberty Pumps 7000 Apple Tree Avenue Bergen, New York 14416 Phone 800-543-2550 Fax (585) 494-1839 www.libertypumps.com Copyright Liberty Pumps, Inc. 2017 All rights reserved. LLIT4600-R08/17