Assembly. Host Sub-D Alarm

Similar documents
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

Technical Data. Dimensions

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Inductive slot sensor

Temperature Measurement Transmitters for field mounting

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Technical Data. Dimensions

technical datasheet technical datasheet

Manual Power relay SR853

operational excellence Solutions for

Technical Data. Dimensions

VERSAFLOW VORTEX Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Engineering Guideline. pac- Carriers Type Universal

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. Dimensions

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

Product Information to the manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Instrumentation Products and Applications

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

PEPPERL+FUCHS GmbH

Segment design & and Bus Diagnostics

OPTIBAR DP 7060 Supplementary Instructions

Indoor/outdoor resistance thermometer Model TR60

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Temperature measurement with SITRANS T siemens.com/processinstrumentation

OPTIBAR P 1010/2010 C Supplementary instructions

Fieldbus Foundation TM Bus diagnostics and troubleshooting

Two global companies, one solution.

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Operating Manual MS220DA

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

AO Annunciator Module

Dräger Polytron 7000 Fixed gas detector

Model 144H. Product Data Sheet , Rev DB February Content

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

explosion protection automation global partner of the process industry

Ultrasonic Level Measurement nivopuls FDU 10 S

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Operating Instructions Edition 02/2007

INTERFACE PRODUCTS SYSTEMS AND SOLUTIONS

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Integrated Solutions Low Voltage Systems

Safety instructions VEGAPULS 64

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Dräger Polytron 8700 IR Detection of flammable gases and vapors

custom cabinets and junction boxes

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

M2500 Engine Controller Installation Manual

Tank Gauging System Special Safety Instruction

SCHMIDT LED Measured Value Display MD Instructions for Use

Technologies, Solutions, and Applications. Radiation-based Level

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Annubar Flowmeter Series

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Intelligent sensing for every temperature and condition

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

Enraf Servo Gauge 854 XTG

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

SITRANS T temperature transmitters A broad product family for every application. sitrans

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

SIL2-Interface/ -Signal Conditioners Series DuoTec

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Transcription:

HighDensity Power Hub, Generic Interface Features Assembly 4 segments, loadsharing redundancy Output: 22... 24 V/360 ma, Ex ib IIC for intrinsically safe, highpower segments Redundant connection to PROFIBUS DP For FOUNDATION Fieldbus H1 and PROFIBUS PA Customizable for any host system Individual modules per segment Optimized for size and quality, low heat dissipation Passive impedance for high reliability Installation in Zone 2 Function The FieldConnex Highdensity Power Hub is a modular fieldbus power supply for four segments. It supports optional Advanced Diagnostics for fast fieldbus commissioning and online monitoring. The kit comprises one motherboard and eight power supply modules (2 modules per segment). (Dynamic Arc Recognition and Termination) enables the intrinsically safe HighPower Trunk Concept for a completely intrinsically safe segment certified acc. to IEC 6007911. A SubD 2pin connector with fieldbus power hooks up to the Segment Coupler for direct PROFIBUS DP connection. Through designed custom cables this power hub is easily adaptable to any FFcontrol system. Sockets for all modules enable simple installation and replacement without tools. Power redundancy is loadsharing with either module supplying half of load current. Threeport isolation between segment, bulk power and host enhances system reliability. Availability and a long service life is achieved through: only one passive impedance filter per segment, optimized design for low power dissipation, highavailability fieldbus termination and plugin connectors with retaining screws. R Connection PS Diagnostic Bus Host 1... 4 SubD 2 + S Trunk 1 Trunk 2 Trunk 3 Trunk 4 Bulk 1 Bulk 2 + + Alarm + Host SubD 2 T Z + S Trunk Bulk 1 Bulk 2 + + www.pepperlfuchs.com painfo@us.pepperlfuchs.com painfo@de.pepperlfuchs.com painfo@sg.pepperlfuchs.com 1

General specifications Design / Mounting Motherboard based Supply Connection redundant Rated voltage U r 19.2... 3 V SELV/PELV Rated current I r 3230... 1820 ma Fieldbus interface Number of segments Redundant 4 Rated voltage U N 20.8... 22.3 V Rated current I N 360... 10 ma Shortcircuit current 413 ma Hostside 2pin SubD socket Hostrated voltage 10.1... 11 V Hostrated current... 40 ma Host shortcircuit current... 0 ma Terminating resistor 100 Ω, integrated Indicators/operating means LED ERR red flashing: shortcircuit or undervoltage at output LED PWR green if U out > 21 V Fault signal VFC alarm output via connectors Rated voltage 0 V Rated current 1 A Galvanic isolation Hostside/Supply 0 V functional insulation acc. to IEC 62103 Fieldbus segment/hostside 20 V safe galvanic isolation acc. to EN 6007911:2007 Fieldbus segment/fieldbus segment 60 V safe galvanic isolation acc. to EN 6007911:2007 Fieldbus segment/supply 20 V safe galvanic isolation acc. to EN 6007911:2007 Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 613261:2006 Standard conformity Electromagnetic compatibility NE 21:2006 Degree of protection IEC 6029 Fieldbus standard IEC 61182 Shock resistance EN 60068227 Vibration resistance EN 6006826 Ambient conditions Ambient temperature 40... 60 C (40... 140 F) when mounted on a horizontal DIN rail Storage temperature 40... 8 C (40... 18 F) Relative humidity < 9 % noncondensing Shock resistance 1 g, 11 ms Vibration resistance 1 g, 10... 10 Hz Pollution degree max. 2, according to IEC 60664 Corrosion resistance acc. to ISAS71.04198, severity level G3 Mechanical specifications Connection type plug with screw flange Core crosssection 2. mm 2 Housing material Polycarbonate Degree of protection IP20 Mass approx. 2.4 kg Dimensions see dimensions Mounting DIN mounting rail, according to DIN EN 6071 Data for application in connection with hazardous areas EUType Examination Certificate PTB 10 ATEX 2034, PTB 10 ATEX 2020 X, PTB 11 ATEX 2010 X Marking II 2 G Ex ib IIC T4, II (2) D [Ex ib] IIIC, II 3(2) G Ex nac [ib] IIC T4 Supply Host interface Alarm output Directive conformity Directive 94/9/EC EN 600790:2009, EN 6007911:2007, EN 600791:2006, EN 600792:2010, EN 6124111:2006 www.pepperlfuchs.com painfo@us.pepperlfuchs.com painfo@de.pepperlfuchs.com painfo@sg.pepperlfuchs.com 2

International approvals IECEx approval IECEx PTB 12.0022X IECEx PTB 12.0023X IECEx PTB 12.0024X Approved for [Ex ib] IIC [Ex ib] IIIC Ex nac II T4 Certificates and approvals FOUNDATION Fieldbus FF831 Marine approval DNV A14038 General information Supplementary information ECType Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Dimensions 1 2 3 4 2 1 200 (7.8) 10 (.9) 163, (6.4) 8 7 6 All dimensions in millimeters and inches (values in brackets) and without tolerance indication. : 1 Connections for alarm voltage free contact and diagnostics bus Diagnostics link cable, optional accessory 2 Connections for redundant bulk power supply 3 SUBD Host 4 Diagnostic Module, see separate data sheet Power supply module HD2FBPSIBD1.24.360 6 Ground connection clamp 7 Connections for fieldbus trunk 8 Motherboard Scope of Delivery 1 x MBHDFBD4R.GEN Motherboard 4 segments, for redundant power modules 8 x HD2FBPSIBD1.24.360 Power Supply Module, isolated, output 360 ma, max. 24 V Diagnostic module selection The following diagnostic modules are compatible with this motherboard. HD2DMB HD2DMA HD2DMA.RO Diagnostic Module, basic version Diagnostic Module, advanced version Diagnostic Module, advanced version, relay output The stationary and mobile Advanced Diagnostic Module (ADM) and related components provide measurement tools for the fieldbus physical layer. The ADM monitors many quality indicating values of the fieldbus physical layer. An expert system, which www.pepperlfuchs.com painfo@us.pepperlfuchs.com painfo@de.pepperlfuchs.com painfo@sg.pepperlfuchs.com 3

is included, analyzes the values and issues easy to understand messages indicating cause and remedy. The ADM is recommended for: Faster commissioning and plant startup: Installation issues are known and corrected before loop check commences Reliable operation through online monitoring: The quality of the physical layer and installation is monitored making fieldbus a manageable asset Efficient troubleshooting: An expert system guides the user through issues and faults in the fieldbus installation Many other tools are included that enhance fieldbus installation and upkeep. Please see datasheet on HD2DMA. Connection to DCS PROFIBUS motherboard / SubD cable connection PROFIBUS Power Hub Gateway Modules are mounted on a separate motherboard that is connected to the motherboard with the power modules via a SubD cable. The SubD cable comes with the gateway motherboard. Motherboards: MBFBGT MBFBGTR Gateway Module: HD2GTR4.PA Gateway Motherboard Gateway Motherboard, redundant PROFIBUS DP/PA Gateway Module Invensys cable connection The motherboard can be connected to Foxboro I/A Series with FBM228 host modules using a dedicated system cable ACCMBHGC.FOX.010 FieldConnex Power Hub system cable for Foxboro FBM228, length 1 m ACCMBHGC.FOX.020 FieldConnex Power Hub system cable for Foxboro FBM228, length 2 m ACCMBHGC.FOX.030 FieldConnex Power Hub system cable for Foxboro FBM228, length 3 m ACCMBHGC.FOX.00 FieldConnex Power Hub system cable for Foxboro FBM228, length m ACCMBHGC.FOX.100 FieldConnex Power Hub system cable for Foxboro FBM228, length 10 m ACCMBHGC.FOX.10 FieldConnex Power Hub system cable for Foxboro FBM228, length 1 m ACCMBHGC.FOX.200 FieldConnex Power Hub system cable for Foxboro FBM228, length 20 m Honeywell cable connection The motherboard can be connected to Honeywell Series C with FIM4/FIM8 host modules using a dedicated system cable. ACCMBHGC.HON.010 FieldConnex Power Hub system cable for Honeywell C300, length 1 m ACCMBHGC.HON.020 FieldConnex Power Hub system cable for Honeywell C300, length 2 m ACCMBHGC.HON.030 FieldConnex Power Hub system cable for Honeywell C300, length 3 m ACCMBHGC.HON.00 FieldConnex Power Hub system cable for Honeywell C300, length m ACCMBHGC.HON.100 FieldConnex Power Hub system cable for Honeywell C300, length 10 m ACCMBHGC.HON.10 FieldConnex Power Hub system cable for Honeywell C300, length 1 m ACCMBHGC.HON.200 FieldConnex Power Hub system cable for Honeywell C300, length 20 m Accessories ACCMBHDC ACCMBHGC Diagnostic link cable, length 6 cm Motherboard connection cable, spare part www.pepperlfuchs.com painfo@us.pepperlfuchs.com painfo@de.pepperlfuchs.com painfo@sg.pepperlfuchs.com 4

1 2 3 4 6 7 8 9. 0 1 2 3 4 6 7 8 9. 0 1 4 7. 2 8 0 3 6 9 The intrinsically safe HighPower Trunk with PS max. 1000 m Zone 2 Zone 1 max. 120 m protects the fieldbus trunk. The power supply limits energy on the trunk to intrinsically safe levels Ex ib IIC. Fieldbus components i.e. Fieldbus power supply, Segment Protectors, and related accessories must be compatible with each other. They are covered under a single system certificate. The Segment Protector provides outputs certified Ex ib IIC for today's intrinsically safe fieldbus instruments. www.pepperlfuchs.com painfo@us.pepperlfuchs.com painfo@de.pepperlfuchs.com painfo@sg.pepperlfuchs.com