What is the principle of Infra-Red detection? Humans and most other live forms radiate infra-red waves in band lengths from 7 to 14 microns so pyro-elements in PIR detectors are set to detect these bands. PIRs detect sudden changes in Far Infrared radiation levels and produce corresponding electrical signal. In principle, PIR detectors sense the temperature differences between the background and moving object in a predetermined detection areas
Curtain-Shaped Coverage 4 m (13 ft) Each curtain has this field of view: 1-8 m (4-25 ft) Continuous curtain no gaps! 2 m (9 ft) Nominal range Detectors feature one or more zones that are sensitive to objects moving into or through them
PRO E Features Best performance in alarm and nuisance alarms in the industry, proven in countless applications and specific tests by independent experts. NEW: Anti Masking alarm NEW: 360PROtect : Covers the area between -1 to +8m to eliminate creep zones NEW: Advanced 3D-tamper detection signals an alarm if detector alignment is altered, in addition to traditional cover switch New: Digital Compass also detects very slow horizontal misalignment which an acceleration sensor would not pick up NEW: Wall and pole removal detection NEW: included cable managed bracket for pole and wall mounting NEW: icommision tool allows *remote* vertical alignment NEW: up to 5 freely configurable alarm outputs (3: Standard, 5 H-Version) Modular design allows to replace silicon wafer / plastic filter in the field replace or retro-fit heater module in the field Wireless versions with sophisticated solar and battery power management and Inovonics wireless integration
Vandal and Manipulation Detection New Feature: Anti Masking Active IR proximity sensor protects ca. 50cm in front and below detector Any obstruction in that area will be detected If completely covered, immediate (!) specific alarm (competition takes around 2 minutes)
Vandal and Manipulation Detection New Feature: Advanced 3D Tamper Altering the alignment which is stored during setup, horizontal, vertical or pitch, triggers a tamper alarm. Digital compass detects even very slow (!) horizontal alignment changes
Vandal and Manipulation Detection New Feature: Proximity sensor in main housing Active IR proximity sensor in main housing Will even trigger when parts of lid are removed (e.g. by sawing), which would not affect a standard cover switch Only way to detect flooding or foaming of the housing
Creepzone coverage and beyond New Feature: 360PROtect An additional dual PIR sensor in the top-front covers the area between up to 1m behind the detector and up to 8m in front of it, eliminating all creep zones (other than 51/85) Covers all the way up to any wall and even *behind* the pole the detector is mounted to An additional 360PROtect output signal allows localization Concept allows stand-alone application of curtain detector
Product Line Overview Standard model PRO E-xxx Operating temperature: 20º to +60ºC (-4º to +140ºF) 3 outputs High-performance model PRO E-xxxH Silicon wafer front filter Extended operating temperature range starting at 40ºC/F About 25% greater detection range Heated optics (to avoid fogging) 5 outputs Wireless model PRO E-xxxRF 300m wireless data transmission intelligent power management of internal and external sources custom data bus for commissioning
Volumetric Medium-Range PRO E-18 (CH10055001) PRO E-18H (CH10055101) Model Standard H-Version Nominal Range Width @ NR 21 m (70 ft) 24 m (80 ft) 30 m (100 ft) 27 m (90 ft)
Volumetric Wide-Angle PRO E-18W (CH10053001) PRO E-18WH (CH10053101) Model Standard H-Version Nominal Range Width @ NR 21 m (70 ft) 27 m (90 ft) 24 m (80 ft) 30 m (100 ft)
Volumetric Medium-Range PRO E-30 (CH10073001) Model Nominal Range Width @ NR Standard 30 m (90 ft) 20 m (100 ft) *Use PRO E-18H as H-version of PRO E-30
Volumetric Medium-Range Narrow-Angle PRO E-40 (CH10073001) Model Standard Nominal Range 40 m (130 ft) Width @ Nominal Range 10 m (33 ft) *Use PRO E-45H as H-version of PRO E-40
Medium-Range Curtain PRO E-45(CH10023001) PRO E-45H(CH10023101) Model Standard H-Version Nominal Range 50 m (165 ft) 60 m (200 ft) Width @ Nominal Range 3.3 m (11 ft) 3.9 m (13 ft)
Directional Medium-Range Curtain Dual Channel PRO E-45D(CH10023201) PRO E-45DH(CH10023301) Typical 5 times lower nuisance alarm rate compared to the PRO E-45(H) if configured in unidirectional mode (left to right or right to left)! Model Standard H-Version Nominal Range 50 m (165 ft) 60 m (200 ft) Width @ Nominal Range 3.6 m (12 ft) 4.2 m (14 ft)
Long-Range Curtain Triple Channel PRO E-100(CH10033001) PRO E-100H(CH10033101) Model PRO E-100 PRO E-100H Nominal Range 120 m (400 ft) 150 m (500 ft) Width @ Nominal Range 2.7 m (9 ft) 3.3 m (11 ft) Multi-zone detector with separate amplifier / signal processing for each zone Zone information as separate outputs and data protocol
SUPER Long-Range Curtain Triple Channel PRO E-400H(CH10100001) 220m Model Nominal Range Width @ Nominal Range PRO E-400H 220m 4.7 m Multi-zone detector with separate amplifier / signal processing for each zone Zone information as separate outputs and data protocol
Wireless Detectors
Same great Features as our wired PRO E detectors 1. Same industry leading performance in nuisance alarms and alarm recognition as our wired detectors as = > proven in countless tests and applications 1. Same extensive accuracy and quality test of each detector = > reliable unit out of the box 1. Same extensive set of functions* as our wired detectors (360PROtect, anti-masking, 3D tamper, digital compass, etc.). = > No competitor with a comparable feature set, wired or wireless 2. Same software interface** for commissioning, fine tuning and maintenance as our standard detector. = > exact, customizable installation, unique for each site * only minor exception is tamper switch in main housing instead of proximity switch ** Custom interface module necessary (PRO E-IFM-RF), not RS-485 compatible
Wireless Detector Features 1. Detector Range Long (PRO E-100RF) and mid range curtain (PRO E-45RF) Volumetric (PRO E-18WRF) 2. Power Management Powered by 4 off-the-shelf D-type batteries ( mono, 1.5 V Alkaline or 3.6V Lithium) Running on Alkaline up to 2y*, running with Lithium Thionylchlorid up to 5y* Optional external power input (solar panel, wind generator, etc). Optional internal Solar Storage Module to store power during the day and use the stored power during night Optional back up battery to keep full function for 30 days if main battery is discharged (fault massage will be generated) Intelligent power management handles all different power sources to optimize battery life time 3. Wireless outdoor range up to 300m/1000ft, repeater to double the range 4. Main alarm, tamper alarm, low power alarm via RF and one local alarm dry contact (NO/NC). 5. Inovonics panels (supporting from 4 up to 32 detectors, up to 12 relay outputs) *assuming moderate temperatures and typical amount of alarms
Certified Geographic Markets
Medium-Range narrow Curtain PRO E-45-RF Mid range 50x3.3m (165x11ft) ideal for limited optical range (e.g. common fog) or matched with video analytics
Long-Range Curtain Triple Channel PRO E-100-RF 120m(400ft) long range ideal for efficient coverage of long straight section Multi-zone detector with separate amplifier / signal processing for each zone Alarm localisation through zone information as separate outputs and data protocol
Medium Range Volumetric Wide-Angle PRO E-18W-RF Precision segmented mirror optics Unique pulse count feature massively reduced nuisance alarm, taking advantage of the discrete areas of detection Covering a nearly square 21x24m (70x80ft)
Inovonics wireless modules 1. Uni-directional transmitters, part of any RF detector 300m range indoors, 150m if receiver inside http://www.inovonics.com/products/rf-modules/ 1. Uni-directional receiver panels for wireless alarm management of the associated RF detectors PLEASE NOTE: The number of channels means *NOTHING* The number of outputs divided by 3 counts!! (12 outputs => 4 detectors) http://www.inovonics.com/products/add-on-receivers/ 1. Repeater modules, extending the standard range by RFe: 300m; RFn: 3000m (!!) Repeaters need an additional power supply http://www.inovonics.com/products/repeaters/
RF Detectors Topology Wireless detectors are connected to the Inovonics uni-directional receiver panel for wireless alarm management Inovonics Panel ift-e CMS
RF Detectors Topology Additional more remote detectors are connected to the Inovonics repeater module which is wirelessly connected to the receiver panel Inovonics Panel ift-e CMS
Installation Tools and Accessories
Accessories of PRO E series and PRO E Wireless series Universal Telescopic Sight IFM-485-ST Interface Module icommision PRO Software scope view and configuration PRO E-IFM-RF Interface Module and Inovonics Receiver Module CT PRO X Wireless Walk Tester
Installation and use of Long Distance PIR Detector PRO E-400H (range up to 220 m)
SUPER Long-Range Curtain Triple Channel PRO E-400H 220m Model Nominal Range Width @ Nominal Range PRO E-400H 220m 4.7 m Multi-zone detector with separate amplifier / signal processing for each zone Zone information as separate outputs and data protocol
Product Highlights Industries first 220m PIR detector Save installation cost due to reduced poles, cabling, number of detectors and installation time Double-knock functionality of two detectors results into 7 detection zones, managed by FastTrace or HeiTel VidoeGateway for accurate visual verification Integrated Cable Management - Invisible cable routing for tamper protection Remote configuration and alarm management via RS485-communication
PRO E-100H vs. PRO E-400H
Application Example Solar Field High value due to copper cabled and photovoltaic modules Remote location, long ways, difficult to reach Example: Solar field of 600 x 600 meters (36 ha)
At a distance of 600 meters four units are needed At a distance of 600 meters three units are needed Result: at a solar field of 600m x 600m up to four detectors can be saved using the super long range PIR. The bigger the area the less the number of needed detectors
Installation hints - deflection A small deflection will influence the detection range and the sensitivity enormous. The following chart gives an overview about the allowed pole deflection of various detection ranges. Especially for long range detectors with e.g. 200m the deflection must be as small as possible. The calculation depends on the installation height (pole length) and the wind speed (max. 150km/h) and will be calculated with [pole height] / [wind speed] = [allowed pole deflection]. An example would be 400cm / 150 km/h = 2.7