GROWING DEMAND FOR COGENERATION SOLUTIONS

Similar documents
96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

HIGH EFFICIENCY COMMERCIAL BOILERS

Stainless Steel Indirect Water Heaters

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

HIGH EFFICIENCY COMMERCIAL BOILERS. Thermal Efficiency RIDE THE LOCHINVAR WAVE. Registered under U.S. Patent #9,746,176

HIGH EFFICIENCY CONDENSING GAS COMBINATION BOILERS FIRE TUBE COMFORT DONE RIGHT. 95% AFUE Efficiency. f ive. nt y. pa rts w a

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Lochinvar Leadership. Innovative High-Efficiency Water Heating Products

iq751/iq1001/iq1501 Specifications (Floor-standing units)

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

THE NEXT GENERATION IN CONDENSING BOILERS M-SERIES

Stainless Steel Indirect Water Heaters

M-SERIES. endless. quality and support. The highest standards of quality. 100 years of smart comfort. rinnai.us rinnai.ca

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

Tankless Condensing High Efficiency Water Heaters

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Date: Project #: Engineer: Prepared By: Bid Date:

Heat Pumps COMFORT NEED IT. When You

High Efficiency Commercial Gas Water Heaters

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Warmth and Comfort. cy and savings.

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

THE NEXT GENERATION IN CONDENSING BOILERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Project Name: Location: Engineer: Contractor: I. GENERAL

Outdoor Reset Control Theory FULL versus PARTIAL reset

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

AHRI Certification Program Scopes - COOLING

VENDED. Speed Queen Stack Tumble Dryers. 30 lb Tumble Dryer 45 lb Tumble Dryer

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

High Efficiency Commercial Gas Water Heaters

LE Series. Electrode Steam Humidifiers

JH Series Installation

Endless water. Zero waste. Commercial. High-output, on-demand water heaters. iq Series, Gen II

Best Practices for Condensing Boilers

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Energy Efficiency & Commercial Building Natural Gas Technologies. Presented by: Eric Burgis Energy Solutions Center

Going allstate of. the art. Pumps bring university dorms in New Hampshire into next decade ALSO:

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

P-K MACH HIGH EFFICIENCY, COMMERCIAL BOILERS

TABLE B Remote Wire Connection

iq251, Gen II Submittal Data

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

Update Dedicated Heat Recovery Chiller Technology. Don Frye. Gulf South

heat interface units A BOILER WITHOUT A FLAME

Commercial Applications

i200, Gen II i250, Gen II Submittal Data

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Industrial Applications

Hubbell NX500 High Efficiency Gas Condensing Water Heater

HIGH EFFICIENCY RESIDENTIAL BOILERS FIRE TUBE A PERFECT BOILER FOR EVERY NEED

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

GEOTHERMAL DESIGN GUIDE

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

TANKLESS PRODUCT GUIDE

Utica Boilers MAC Submittal

MECHANICAL VENTING VERSATILITY

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Danfoss Solar Solutions Application Handbook

Commercial Gas Water Heaters

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

CONDENSING HIGH EFFICIENCY BOILERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Concrete Applications

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

HL SERIES Fluid heating for commercial applications

High temperature air-to-water heat pumps

Installation & Operation Manual Models: TSU

MAYTAG Maytag, 403 W. Fourth St. N., Newton, IA CL654 PRINTED IN THE U.S.A. 02/02

LAARS MINI-THERM Gas-Fired Residential Hydronic Boilers

prestige Control Application Supplement - TriMax

It won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

iq1001, Gen II Submittal Data

Energy Efficiency Potential of Heat Pump Water Heaters in Commercial Buildings

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Indirect Fired Water Heater

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

CodeNotes. Solar Water Heating Systems Based on the 2018 International Solar Energy Provisions (ISEP ) Introduction OFFICIAL

Submittal Data GAHP Line W LB Series Ground Source Gas Fired Absorption Heat Pump Heating and Cooling

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

The Brute MagnaTech. A Perfect Balance of Size, Form, and Function. Commercial, High Efficiency Condensing Boiler and Volume Water Heater

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

A Better Boiler Just Got Better. Better Boilers. New Size Available. Express Setup. Load Status. User Setup. Installer Setup. Diagnostics.

Copeland Scroll Outdoor Refrigeration Unit

Transcription:

Greater savings and efficiency in areas where electricity costs are high. GROWING DEMAND FOR COGENERATION SOLUTIONS XRGI 25 MICRO COMBINED HEAT AND POWER APPLICATION GUIDE

THE LOCHINVAR DIFFERENCE BROADEST LINE OF WATER HEATING SOLUTIONS IN THE INDUSTRY NO ONE BRINGS IT ALL TOGETHER LIKE LOCHINVAR For nearly 80 years, Lochinvar has been a leader of innovation in high-efficiency water heating. Through Lochinvar s pride in leadership, proven product ingenuity and commitment to excellence, the company has continually improved year after year. Today, Lochinvar touts the broadest line of high-efficiency water heating solutions, a world-class research and development department, comprehensive service with every sale, and industry-leading training through Lochinvar University. That s why no one brings it all together like Lochinvar. INDUSTRY-LEADING ONLINE TRAINING THROUGH LOCHINVAR UNIVERSITY A WORLD-CLASS RESEARCH & DEVELOPMENT DEPARTMENT THAT CONTINUOUSLY INTRODUCES NEW AND INNOVATIVE TECHNOLOGY an industry leader in the making, 1954. ALWAYS LEADING THE CHARGE A COMMITMENT TO IN-DEPTH SERVICE BEFORE, DURING AND AFTER EVERY SALE Lochinvar redefined the industry with the space-saving, high-efficiency Power-Fin design. It was the first major step we took in becoming the industry leader. Since that time, we ve become the leader other companies call upon for the most advanced and efficient water heating products in the world. Now we are ready to lead the charge in a new direction with our new Micro Combined Heat and Power (CHP) solution.

THE NEXT GENERATION IS COGENERATION Combined Heat and Power (CHP) technology often called cogeneration is a game changer for light commercial facilities across North America. Our new MicroCHP solution (< 50 kw/hr) gives you the high-efficiency water heating you d expect from Lochinvar while simultaneously generating electricity as it heats. This means once it s installed, you will see an instant drop in your electricity bill. Our commitment to give you the broadest lineup of water heating solutions has led us to partner with EC POWER. As the #1 European producer of commercial MicroCHP systems where cogeneration technology is already widespread, EC POWER shares our value for providing the most reliable and efficient products possible. LEVERAGING THE SPARK SPREAD: WHERE MICROCHP MAKES SENSE Since our cogeneration unit runs on natural gas, MicroCHP technology is an ideal heating solution for regions where the spark spread the difference between the cost of electricity and natural gas is wide. A cogeneration system uses relatively low-cost natural gas to generate supplemental electricity on site, immediately reducing your reliance on more expensive electricity from the grid. Even within these regions, MicroCHP doesn t make sense for every customer. Businesses that would benefit most from MicroCHP technology have a high hot water load that lasts for extensive periods of time multifamily housing, hotels, hospitals, colleges, restaurants and swimming pools. INGENUITY YOU EXPECT FROM LOCHINVAR Since MicroCHP is a relatively new technology in North America, its adoption is being driven by a company with the resources and know-how to introduce new products. At Lochinvar, we have what it takes to offer customers the benefits of both proven water heating technology and on-site electricity generation. With the ability to provide storage tanks, control units and everything else needed for easy installation, nobody brings the power of cogeneration together like Lochinvar. MICROCHP FEATURES 1. EASY INSTALLATION Lochinvar's MicroCHP is designed to be easily installed by most trained contractors, making a traditionally complex system much easier to install and service. 2. FULL SYSTEM COMPATIBILITY Not only is Lochinvar providing a top-of-the-line MicroCHP, but also the additional storage tanks and control units to complete the system. Once installed, cogeneration systems like MicroCHP can achieve extraordinary conversion efficiencies of 75 to 90 percent.

TECHNICAL DATA FOR THE XRGI 25 Cogeneration Specification Sheet XRGI25-01 POWER UNIT Manufacturer EC POWER Generator Output kw (Btu) 24 (81,891) Type Asynchronous / Induction Engine Cylinders Qty Ignition Distributorless, Direct Fire Combustion Stoichiometric Rotation Speed RPM EFFICIENCY Electrical (LHV/HHV) 100% Load Heat (LHV/HHV) 100% Load Overall (LHV/HHV) 100% Load ELECTRICAL iq25 Contral Panel 4 1850 31%/28.2% 62%/56% 93%/84.2% Input 480 V/ 3 PH / 60 Hz 480 Leg (3 hot, 1 neutral, 1 ground) Input, Max Fuse Amps Output (3 phase) Amps kw Short Circuit Rating (SCCR) 63 36 24 ka 10 Grid Connection Direct Protection Grade IP Q70 Heat Distributor 54 Input 240 Volts Input, Max Fuse Amps (1 hot, 1 neutral, 1 ground) 10 EXHAUST 3 in. Adapter Included Material UL 1738 Approved Length ft (m) 150 (45.7) Temperature Max F ( C) FUEL 250 (121) Input Btu (kw) 262,000 (76.8) Type Natural Gas Input Max (Static) WC (in.) 20 Input Min (Static) WC (in.) 4.5 Connection NPT 3/4 in. Adapter Included HYDRONIC Piping, Unit Connection Size Piping, System Connection Size BSP 1-1/4 in. Hoses Included Rated Hot Water Outlet F ( C) Max. Hot Water Max Rated Hot Water Return NPT 1-1/4 in. Adapters Included 185 (85) F ( C) 185 (85) F ( C) 167 (75) Output Btu (kw) 163,000 (47.7) iq25 CONTROL PANEL DIMENSIONS Width in. (mm) 23-5/8 (600) Height in. (mm) 23-5/8 (600) Depth in. (mm) 8-3/4 (210) Weight lb (kg) MAINTENANCE 66.1 (30) Interval (run hours) Hours ENVIRONMENT Maximum Ambient Temperature 4000 F ( C) 95 (35) POWER (ENGINE) UNIT DIMENSIONS Width in. (mm) 29-1/2 (750) Length in. (mm) 44-1/8 (1120) Height in. (mm) Weight (ready to operate) 46-1/8 (1170) lb (kg) 1501 (681) Q70 HEAT DISTRIBUTOR DIMENSIONS Width in. (mm) 21-3/4 (550) Height in. (mm) 23-5/8 (600) Depth in. (mm) Weight lb (kg) 11-5/8 (295) 97 (44)

INSTALLATION REQUIREMENTS Piping diagrams within this document are for reference only. Design and install any necessary hydronic, safety and control components in accordance with local regulations. Only install this system with storage tanks designed for µchp (general use storage tanks are not designed to meet the needs of the µchp system). High return temperatures can cause malfunctions. Avoid excessive flow in the µchp system. Operate the heating system at the lowest possible return temperatures. Refer to the Installation and Operation manual for information on hydronic and electrical connections. NOTES Always set TF higher than the system set point in the control settings to give the MicroCHP priority over the heating system so the unit always supplies the base load heat. Select the flow master size based on the discharge capacity required. Use a minimum of two (2) storage controls with eight (8) temperature sensors in system utilizing more than one MicroCHP. Proper hydronic integration (and prevention of short cycling) is necessary to comply with warranty conditions. PIPING DIAGRAM: HYDRONIC INSTALLATION

PIPING DIAGRAM: HYDRONIC RETROFIT NOTES Always set TF higher than the system set point in the control settings to give the MicroCHP priority over the heating system so the unit always supplies the base load heat. Select the flow master size based on the discharge capacity required. Use a minimum of two (2) storage controls with eight (8) temperature sensors in system utilizing more than one MicroCHP.

PIPING DIAGRAM: DHW NEW INSTALLATION NOTES Use a minimum of two (2) storage controls with eight (8) temperature sensors in system utilizing more than one MicroCHP.

PIPING DIAGRAM: DHW RETROFIT NOTES Use a minimum of two (2) storage controls with eight (8) temperature sensors in system utilizing more than one MicroCHP.

FLOW MASTER SENSOR INSTALLATION GUIDE Flow Master injection pipe TF= FLOW TEMPERATURE TB= BYPASS TEMPERATURE TR= RETURN TEMPERATURE TS= SUPPLY TEMPERATURE }*) No obstruction Main Return Return to Storage Tank Flow Master injection pipe Return to Storage Tank ABOVE: installation in Horizontal pipework (connect to underside of main): Main Return LEFT: Installation in vertical piprework (upward flow) CONSIDERATIONS Ensure there are absolutely no obstructions to the flow (e.g. check valve) on the main pipe between the Flow Master and Storage Tank. The Flow Master will automatically maintain the correct direction of flow between these connections. Note the following when installing the temperature sensors: Install temperature sensors in immersion sleeves to obtain accurate and faster readings. Ensure that the heating water in a vertical piping configurations flows upwards (ascending). Ensure that the temperature sensors (in immersion sleeves) in horizontal piping configurations are fitted from above and the supply and return connections are fitted from below. Distance from Tf to the injection line of the µchp/storage Tank: minimum of 5 x D (pipe diameter). Distance from Tb to the injection line of the µchp/storage Tank: minimum of 5 x D (pipe diameter). Distance from Tr to the return line of the µchp/storage Tank: maximum of 5 x D (pipe diameter). When installing the injection line from the Flow Master, ensure that the 185 F hot water injected from the µchp is well mixed within the main flow of heating water and that there is no temperature stratification in the pipe (particularly at low flow rates).

INCLUDED WITH MICROCHP FLOW MASTER FLOW MASTER CONTROL HOW IT WORKS The Flow Master Control is supplied with the Flow Master and regulates the delivery of heat from the µchp to the system supply (via the Flow Master valve and variable speed pump) to maintain the required supply temperature Tf set on the IQ Control Panel. The Flow Master Control also protects the µchp system from excessively high return temperatures, automatically prevents reverse flow between µchp/flow Master connections, and ensures minimal consumption of electricity by the pump. The Flow Master maintains the set temperature at Tf by mixing 175-185 F water from the µchp system into the supply system water. Variations in heat loads and flow rates are compensated for by the Flow Master valve operation and the pump speed; the supply temperature Tf is therefore maintained regardless of the heat load. The pump will stop if the Flow Master valve closes completely (i.e. no heat load). The heat storage will fill up if the heat load is lower than the heat produced by the µchp. The µchp will stop production once the heat storage is full. During periods of peak demand, it will wait until there is sufficient cooling capacity in the heat storage before it restarts, otherwise it will wait until the minimum heat reserve has been reached before starting - none of this affects the steady supply from the Flow Master. If the heat load is greater than the heat produced by the µchp, the heat storage will discharge. When the storage has fully discharged, the temperature Ts at the Flow Master will fall and the Flow Master Control accordingly calculates a maximum supply temperature Tf as basis of control. The Flow Master Control automatically adjusts to actual flow rates and return temperature conditions to achieve stable and precise control. Abrupt changes in supply loads and flow rates are compensated for by special functions to immediately recover and maintain steady control under all circumstances. FIGURE SHOWS FM TYPE 350 FLOW MASTER HOW IT WORKS The Flow Master is a motorized valve and variable speed pump unit controlled by the supplied Flow Master Control module. The heat storage enables the µchp system to service short-term peak loads way beyond the normal output of the Power Unit. This minimizes the need for supplemental heat from backup heating units and maximizes the number of runtime hours and electrical production of the Power Unit. The Flow Master should therefore always be able to deliver at least twice the normal Power Unit heat output, and generally significantly more. The normal heat outputs are based on a delta T of 35 F between the µchp flow and main return, corresponding to a main return temperature of 140-150 F. The Flow Master heat output will increase proportionally with lower return temperatures. The Flow Master provides steady regulation down to approximately 2% of maximum load (provided it has been installed correctly).

FLOW MASTER CONTINUED FM Type Thermal output ΔT Maximum flow rate (at a return of 140 to 150 F) FM 50 170,000 BTU/HR 35 F 9.5 GPM FM 150 512,000 BTU/HR 35 F 28.5 GPM FM 250 853,000 BTU/HR 35 F 47.5 GPM FM 350 1,194,000 BTU/HR 35 F 66.5 GPM STORAGE CONTROL INCLUDED WITH MICROCHP STORAGE TANK HOW IT WORKS The Storage Control is supplied with and manages the storage tank(s). The temperature sensors detect the stratification layer between hot supply water and cold return water. The clear separation of the two is crucial for proper operation of the µchp system. The µchp system requires at least one storage control with four (4) temperature sensors. Operation is not possible without this control. Fully automated Storage Tank management is achieved with the following characteristics: 1. Ensuring a minimum runtime for each start: The Power Unit only starts when there is sufficient cold water in the Storage Tank. 2. Maximum servicing of heat demand by the µchp system: The Power Unit starts before the Storage Tank is empty. The heat reserve needed is continuously determined based on the actual supply profile. The reserve capacities determined by the µchp system vary according to season and heat demand profiles. For instance, in the colder months the system will try to maintain a very high heat reserve, whereas the cold reserve requirement will be minimal. The situation will be reversed in lower heat demand periods, with the system maintaining a much smaller heat reserve along with a larger cold reserve to ensure sufficient periods of operation.

TANKS INCLUDE STORAGE CONTROL STORAGE TANK HOW IT WORKS The Storage Tank forms an integral part of the µchp system and is REQUIRED for proper operation of the system. It ensures that any temporary drops in heat load below the output of the Power Unit do not cause the Power Unit to stop, and enables the µchp system to service temporary heat loads beyond the output of the Power Unit. When heat loads are below the output of the Power Unit for extended periods of time, the Storage Tank allows the µchp system to operate longer and schedule operation according to power load patterns on site. If multiple Storage Tanks are used, they must be installed in series. Experience has shown that parallel or reverse return circuits do not operate satisfactorily and must not be utilized. Use a minimum of one (1) Storage Control with four (4) temperature sensors for a storage capacity of 250 gallons. The Lochinvar Storage Tank with built-in Storage Control ensures proper operation of the µchp system. TANKS INCLUDE STORAGE CONTROL DHW TANK HOW IT WORKS The Domestic Hot Water (DHW) Tank works in much the same way as the Storage Tank, with the addition of an indirect coil installed in the tanks interior. It functions alongside the µchp s control system to ensure proper operation and control over the heat stored in the tank. 1. Potable water is passed through the coil allowing it to absorb heat stored in the tank by the µchp. 2. Cold water is fed into the bottom connection of the coil maintaining the stratification effect within the volume of the tank. 3. Indirect heat transfer provides a second layer of separation between potable DHW and the Power Unit s cooling glycol. Application of the µchp in DHW systems is quite flexible. In new installations, auxiliary heat can be supplied by a boiler tied directly to the DHW Tank as shown in the piping diagrams. Retrofit applications may be directly supplemented by injecting the heated DHW to existing storage.

BOILER CONTROL INCLUDED WITH MICROCHP STORAGE TANK HOW IT WORKS The Boiler Control ensures optimum operation of the µchp and the peak load heating unit (boiler or water heater). A contact in the Boiler Control activates the heating unit to produce heat when consumption exceeds the heat produced by the µchp and the storage tank is almost empty. The heating unit stops as soon as heat production by the µchp exceeds consumption. THE BOILER CONTROL IS CONTROLLED BY THE TWO TOP STORAGE CONTROL SENSORS S1 & S2 IN THE STORAGE TANK AND THE PREDETERMINED FLOW TEMPERATURE TF. If the heat consumption is higher than the heat produced by the µchp over the long term, the top storage tank sensor S1 reads cold. The Boiler Control enables the peak load heating unit to produce heat until the second storage tank sensor from the top S2 reads a sufficient temperature. When this occurs, the Boiler Control disables the peak load heating unit. The optional installation of the Boiler Control ensures that the peak load heating unit is only enabled when it is needed in order to maximize the operation time of the µchp.

Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 LEARN MORE AT WWW.LOCHINVAR.COM