Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Similar documents
Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Using the Model 1500 Portable Chilled Mirror Hygrometer

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Using the DewTrak II Dew Point/ Humidity Transmitter

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

DEW POINT HYGROMETER MODEL DPH-2020/2012 BULLETIN DPH-2020/2012 can be used to extend the lower measurement limit of the system.

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

BC-HTO RELIABLE SENSING TECHNOLOGY

LC1350 Level Controller

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

DEW POINT PROBES. with RS485 IN THIS ISSUE. PN 02 February 2009 DEW POINT PROBES. 1. Applications

Complete packages with Software and Controller

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Measurement and Control Technology

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Sensors & Accessories Compatible with ENVIROMUX-2D/5D/16D ENVIROMUX

Sensors & Accessories Compatible with ENVIROMUX-2D/5D/16D ENVIROMUX

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Accuracy by Design Products for the HVAC Professional

Low Dew Point Instrumentation for Process Control Operations

Sensor Selection Guide. Sensing for Building Applications

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Relative Humidity Transmitters

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Sitron s CF Line of Flow Switch Monitors

Pressure Swing Desiccant Dryers

Hygro/hygrothermal transducers (hygrometric)

Gas Controller Module GC-06

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Constant climate chambers

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

0-10 V Wall & Duct Humidistat Installation Instructions

IMR Environmental Equipment, Inc Central Ave. St. Petersburg, FL Phone:

Duct and Rough Service Carbon Monoxide Sensor

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

Potential Applications

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Duct Humidity/Temp Sensor

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

Seamlessly integrated. The new sensor range from Belimo.

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

SDR Dry Room. Outstanding performance

Product Manual SZ1145

NHRS Series RESISTIVE ELEMENT STEAM HUMIDIFIER. Engineering Manual. Manual No. H

TDS Conductivity Probe In-Line conductivity measurement

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

Environmental simulation chamber for complex alternating climate profiles

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Series A3 and A4 Differential Pressure Controller

icountms Range Fluid Condition Monitoring Moisture Sensors

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

MR SERIES CARD LOGGERS

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

TrueAlarm Analog Sensing

Product Manual SZ1144

EasyLog Data Logger Series

CORPORATE OVERVIEW Canton Rd. Marietta, GA T: F: flwse.com

TrueAlarm Analog Sensing

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

CORPORATE OVERVIEW Canton Rd. Marietta, GA T: F: flwse.com

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

Supertron Sensing Pte Ltd Certificate No. : LA C Blk 16 Kallang Place #07-04 Issue No. : 4 Singapore Date : 04 February 2015

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

KMF Environmental test chamber for constant climate

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

INSTALLATION & USER MANUAL

Heatless Regenerative Compressed Air Dryers. Compressed Air System Products. Made in America

ECOLOG-NET LA8 and WA8 (wireless), 8 x 4..20mA signals

Power and Energy Management Solutions

Hydrazine Analyzer Series 2171 Specifications

Room Humidity/Temp Sensor

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

HUM-M2 Humidity Sensor Module Description

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

Transcription:

The RO120 is a precision transmitter that provides quick and accurate humidity, barometric pressure, temperature, absolute pressure and dew point measurements in a wide range of applications. It has a wide temperature range of -40 C to 120 C and is resistant to most chemicals. This remote type transmitter comes standard with a 6 foot cable and is ideally suited for many different applications such as environmental chambers, compressed air, furnace and industrial applications. Roscid also offers a wall mount and duct mount configuration. Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE: RH: 0-95% (non-condensing)

Temperature: -40 C to 120 C Wall-mount T-range 0C to +60C Dew Point: -60 C to 95 C Pressure rated: up to 700psia Typical model (RO120-P: transducer to 200psi, the RO120-PS transducer reads up to 400psi Barometric Pressure: 1100mB +/-5 mb

Model Type: Description: RO120 A temperature / dew point / RH transmitter with three 0-10V outputs and a RS232 programmable output RO120-B RO120-P A temperature / barometric pressure / RH transmitter or dew point with three 0-10v outputs and a programmable RS232 programmable output A temperature / Pressure (psia) / dew point transmitter with 6-foot cable, three 0-10v outputs and a RS232 programmable output RO120-PS RO120-DIS RO120-B-DIS RO120-P-DIS RO120-PS-DIS A temperature / Pressure (psia) / dew point transmitter with 6-foot cable, three 0-10v outputs and a RS232 programmable output, pressure transducer readings to 400psi A temperature / dew point / RH transmitter with a 2-line LCD display, three 4-20mA outputs, 2 programmable alarm relays and a RS232 programmable output A temperature / barometric pressure / RH transmitter or dew point with a 2-line LCD display, three 4-20mA outputs, 2 programmable alarm relays and a RS232 programmable output A temperature / Pressure (psia) / dew point transmitter with a 2- relays and a RS232 programmable output, transducer reads up to 200psi A temperature / Pressure (psia) / dew point transmitter with a 2- relays and a RS232 programmable output transducer reads up to 400psi RO120-W- DIS A wall mount temperature / dew point / RH transmitter with a 2- relays and a RS232 programmable output

RO120-W-B- DIS RO120-D RO120-D-B RO120-D-DIS RO120-D-B- DIS RO120-SC A wall mount temperature / barometric pressure/rh transmitter with a 2-line LCD display, three 4-20mA outputs, 2 programmable alarm relays and a RS232 programmable output A duct mount configuration with dew point/ temperature / RH transmitter with 6-foot cable, three 0-10v outputs and a RS232 programmable output A duct mount configuration with temperature / barometric Pressure / RH transmitter or dew point with 6-foot cable, three 0-10v outputs and a RS232 programmable output A Duct mount temperature / dew point / RH transmitter with a 2- relays and a RS232 programmable output A duct mount temperature / barometric pressure/rh transmitter or dew point with a 2-line LCD display, three 4-20mA outputs, 2 programmable alarm relays and a RS232 programmable output RO120 Sample Chamber RO120-AB For RO120 probes only, an adapter board that the sensor plug into and the customer is allowed to hard wire to a terminal block GENERAL: Speed of Response: 12 Second response time that is T63, 0 to 90% Storage temperature 150C Cable length: 6 feet, for other lengths contact factory: (for remote and duct mount configurations only) Probe length: 8in (20.3cm): (for remote and duct mount configurations only) Probe Material: 316 stainless steel (for remote and duct mount configurations only) Filter: Sintered filter top, removable

(for remote and duct mount configurations only) Sensor: Polymer-capacitive: for all configurations Fitting: Adjustable ¾ NPT (for remote only) Connections: Screw terminals Wire (20-24awg) standard wire required RO120-SC (Sample Chamber) RO120-AB Sample chamber dimensions (LWD): 5 (127mm) x 3.5 (88.9mm) x 2.125 (53.9mm) OPTIONAL: Sample test chamber: Adapter Board Field Replaceable Sensor tip: RO120-SC RO120-AB (for probe only) FRRO for RO120 FRROP for RO120-P FRROB for RO120-B

DIS: A 2-line LCD display with three 4-20mA out puts, 2 programmable alarm relays and a RS232 programmable output POWER REQUIREMENTS: 18 to 30Vdc, unregulated, 200 ma max