AND ARCHITECT SPECIFICATIONS

Similar documents
AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Advanced Protection System

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

AND ARCHITECT SPECIFICATIONS

Specification/ Data Sheet

MXL/MXLV 19 Rack Mount Equipment

Conventional Releasing Control Panel

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

30.45 Electric Release PDRP-2001

Release Control Fire Alarm Systems

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

AL800ULADA. NAC Power Extender. Installation Guide

TECHNICAL DATA OBSOLETE

AL600ULADA. NAC Power Extender. Installation Guide

Electric Release Panel Wiring Tips

s Notification Appliances

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

good things in small packages

Addressable Fire Alarm Control Panel

PSN-1000 & PSN 1000(E) Installation Manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

FMR Installation Instructions. Addressable Fire System Controller

'08 Series Notification A liances

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Fire Safety. Installation Instructions Model CSM-4 Controllable Signal Module OPERATION INSTALLATION

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

Commercial and Light Industrial Fire Alarm Control Panel

Signature Series Auto-Sync Output Module (CC1S)

MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4

Desigo TM Fire Safety System A comprehensive fire-protection system

SELECT-A-HORN/STROBE SERIES

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Control Panels

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Installation Instructions Model DLC

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Addressable NAC Output Module D327A

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

TrueAlert Addressable Notification Appliances

ANNUNCIATOR FIXED MODULE

1. POWERPATH Operation

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

NETWORK FIRE ALARM CONTROL PANEL. Features

Cerberus PRO A comprehensive fire-protection system

Air Duct Housings. Description

The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel

Z-20 Fire Control Panels

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

TrueAlert Notification Appliances

Agent Release Control Panel

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TrueAlert Addressable Notification Appliances

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

INTELLIGENT FIRE ALARM CONTROL PANEL

Control/Communicator Installation Manual

D7024 Fire Alarm Control Panel

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Desigo TM Fire Safety System A comprehensive fire-protection system

ARCHITECT AND ENGINEER SPECIFICATIONS

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

MR-2602 Two Zone Fire Alarm Control Panel

4100U City and Relay Cards Installation Instructions

Installation Instructions Model ABHW-4S

FireNET Plus Wiring Instructions

TrueAlert Multi-Candela Notification Appliances

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

Dimensions of the Optional Mounting Box (BB-400R/W)

The PDRP-1002/PDRP-1002E Agent Release Control System

SP40S-D. Kingfisher Company, inc. Features: Description:

INSPECTION AND TESTING FORM

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

DS7400Xi Addressable Control/ Communicator

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

TrueAlarm ES Analog Sensing

TrueAlert Multi-Candela Notification Appliances

MPC-6000 / MPC-7000 / RND-2

Transcription:

CSM-4 Controllable Signal/Releasing Module ENGINEER AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices Class A (Style Z) or Class B (StyleY) Circuits 4 VDC.5 Amps Per Circuit City Tie or Lease Line Output Releasing Service Fully Programmable Coded Audibles On Board Microprocessor March Time/Uniform Code 3 Selectable Degrade Operation Silencable/Non-Silencable Option Automatic/Manual Control Circuits Power Limited Per NEC 760 Listed, ULC Listed CSFM, NYMEA, FM Approved NFPA 3, Pre-Action and Deluge NFPA 00, FM-00 Releasing NFPA A, Halon Releasing Description The Controllable Signal Module CSM-4 provides two fully supervised, programmable notification appliance circuits. The CSM-4 supplies two Class B (Style Y) or Class A (Style Z) type output circuits for the supervision and control of listed audible or visual notification appliances such as horns, bells, strobes, etc. Each circuit can provide up to.5 amps (4 VDC) of current to power indicating appliances. Any output on a CSM-4 may be configured as either a supervised connection to a local energy type Master City Box or a supervised connection to a Leased Line remote monitoring system. CSM-4 circuits may also be configured for pre-action or deluge releasing service per NFPA 3, extinguishing agent releasing (Halon, FM-00) per NFPA A and NFPA 00. Each circuit or output may be controlled automatically through the MXL program logic or manually using the MXL keypad. Automatic control may also be time based. Each circuit or output can be manually Armed or Disarmed through the MXL keypad. When any circuit or output has been Disarmed, the MXL LCD annunciator will indicate the affected circuit or output and the Partial System Disable LED will illuminate, until the circuit or output has been returned to the Armed condition. The CSM-4 contains an on-board microprocessor which allows notification circuit outputs to function in a degrade mode even if the main MXL processor or the local network communication link has failed. Each circuit s degrade mode of operation can be separately configured to respond to an alarm in the following manner: OFF, ON, CONTIN- UOSLY or SECOND ON - SECOND OFF. In a degrade mode a CSM-4 will respond to an alarm from any Intelligent/Analog (ALD) initiating device or Conventional Zone (CZM) connected to the same network node. CSM-4 notification appliance circuit outputs may be configured to provide a coded, march time, or uniform code 3 output. This equipment is approved for operation over the temperature range of 0 C to 49 C. CATALOG NUMBER 500

Engineer and Architect Specifications Notification Appliance Circuits shall be provided by a Cerberus Pyrotronics Model CSM-4 plug-in controllable signaling module. The unit shall provide two alarm notification application circuits which may be configured as either Class A (Style Z) or Class B (Style Y). Each circuit will be capable of activating up to.5 amps of listed audible or visual notification appliances. These circuits shall also be capable of being configured for activation of a local energy Master City connection or polarity reversal type Leased Line connection. Each circuit shall also be capable of being configured to activate a solenoid for pre-action or deluge releasing service per NFPA 3, as well as extinguishing agent releasing (Halon, FM-00) per NFPA A and NFPA 00. The notification appliance circuits shall be capable of a degrade mode of operation in the event of main processor failure or loss of network communication. All notification appliance circuits shall be capable of automatic activation or de-activation through control by event or time based programming contained in the control panel. They shall also be capable of manual activation or de-activation using the system keypad. Disarming any circuit or output shall result in the alphanumeric display indicating the circuit or output which has been disarmed as well as the illumination of the System Partial Disable LED. The CSM-4 shall be a plug-in type module using gold plated edge connectors to interface with the MOM- or MOM-4 expansion card cages. It shall occupy one half slot in the card cages. Notification circuit, City Tie and Leased Line power shall be provided to the CSM-4 through the main control power supply or through the supervised remote power supplies. Dimensional Data 6.500 Wiring CSM-4 Installation Slots The municipal tie and leased line applications require the LLM- interface module. The notification appliances and leased line applications are power limited. ELECTRICAL CONNECTIONS FOR NOTIFYING APPLIANCES (NFPA 7 Local). All wiring must be in accordance with Article 760 or NEC or local building codes. 3. Both circuits are power limited to NFPA 70 per NEC 760. 4. Electrical Ratings: Supervisory: Alarm: 8 to 3 VDC, ma max 8 to 3 VDC,.5A max 5. End of line device: Use Cerberus Pyrotronics EOL device,.k, ½ watt, P/N 40-80380 6. Line Resistance: 3 ohms max 4.50 4.500 CSM-4 Board CSM-4 Loop Wiring for Supervised Notifying Appliance Circuit

Polarity shown in Normal State Leased Line Circuits are Power Limited per NEC 760 External Resistance K-5K OHMS NOTES:. Polarity shown in supervisory state.. The total loop resistance from the LLM- to the Municipal Tie, including the 4.5 OHMS in the Municipal Tie, should not exceed.5 OHMS. 3. Either circuit may be used. 4. Municipal Tie circuits are not power limited. CSM-4 Loop Wiring of Supervised Municipal Tie CSM-4 Leased Line Circuit COMPATIBLE NOTIFICATION APPLIANCES Chime/ Strobes Vibrating Bells Electro-Mech. Horn/Strobes Electronic Horns -Tone with Strobe Single Stroke Bells EC-S5-C/F/S EC-S7-C/F/S EC-S75-F/S EC-S0-F/S Strobes S5-F/FS/FT/S/ST S7-F/FS/FT/S/ST S75-F/FS/FT/S/ST S0-F/FS/FT/S/ST HN-S5S-C/F/S HN-S7S-C/F/S HN-S75S-F/S Electronic Horns -Tone EH-C/F/S MH-G/GW MH-U/UW MH-S5-U/UW MH-S7-U/UW MH-S75-U/UW MH-S0-U/UW BE-F/LC BF-F/LC BS-F/LC BT-F/LC Electronic S.W./Strobes EW-S5-C/F/S EW-S7-C/F/S EW-S75-F/S EW-S0-F/S Sync. Electro-Mech. Horn/Strobes Mini-Horns HNH-S5S-C/F/S HNH-S7S-C/F/S HNH-S75S-F/S Chimes EC-C/F/S CH-F/LC/SS MHT-G/GW MHT-U/UW MHT-S5-U/UW MHT-S7-U/UW MHT-S75-U/UW MHT-S0-U/UW ELECTRICAL CONNECTIONS FOR MUNICIPAL TIE (NFPA 7). All wiring must be in accordance with Article 760 of NEC or local building codes. 3. Both circuits are not power limited. 4. Electrical Ratings: Trip Coil: Trip Current: Supervisory Current: Voltage: HN-S5-C/F/S HN-S7-C/F/S HN-S75-F/S HN-S0-F/S Horns/ 3-Tone MC-C/F/S MC-S5-C/F/S MC-S7-C/F/S MC-S75-F/S MC-S0-F/S Sync. Horns/ 3-Tone MC-S5S-C/F/S MC-S7S-C/F/S MC-S75S-F/S Electronic Slow Whoop EW-C/F/S MHST-G/GW MHST-U/UW MHST-S5S-U/UW MHST-S7S-U/UW MHST-S75S-U/UW HNH-S5-C/F/S HNH-S7-C/F/S HNH-S75-F/S HNH-S0-F/S Horns/ 3-Tone MTL-C/F/S MTL-S5-C/F/S MTL-S7-C/F/S MTL-S75-F/S MTL-S0-F/S Sync. Horns/ 8-Tone MTL-S5S-C/F/S MTL-S7S-C/F/S MTL-S75S-F/S Electro-Mech. Horns HN-C/EP/F/S HNH-C/EP/F/S Mini-Horns/Strobes 8-Tone MMT-G/GW MMT-U/UW MMT-S5-U/UW MMT-S7-U/UW MMT-S75-U/UW MMT-S0-U/UW EH-S5-C/F/S EH-S7-C/F/S EH-S75-F/S EH-S0-F/S Sync. Strobes S5S-F/FS/FT/S/ST S7S-F/FS/FT/S/ST S75S-F/FS/FT/S/ST Synchronizing Control Module SCM-F/FW SEA TTH Tri-Tone Horns Sync. Mini-Horns/ Strobes 8-Tone MMT-S5S-U/UW MMT-S7S-U/UW MMT-S75S-U/UW The SCM-F/FW Synchronizing Control Module must be used with these modules to synchronize the strobes. 4.5 ohms 0 to 30mA DC (momentary) ma DC 8 to 3 VDC The total loop resistance from the LLM- to the Municipal Tie, including the 4.5 ohms in the Municipal Tie, should not exceed.5 ohms. 5. Minimum emergency power: 60 hour standby 5 minute alarm BE-SS BF-SS BS-SS BT-SS Bell/Strobe Plate S5-6060H/6090V S7-6060H/6090V S75-6090V S0-6090V Sync. Bell/Strobe Plate S5S-6060H/6090V S7S-6060H/6090V S75S-6090V Suffixes C = Ceiling EP = Explosion Proof F = Flush FT = Flush w/terminals G = Gang Mount H = Horizontal LC = Low Current S = Surface SS = Single Stroke ST = Surface w/terminals U = Universal Mount V = Vertical W = White ELECTRICAL CONNECTIONS FOR LEASED LINE (NFPA 7 Remote Station). When a CSM-4 circuit is used as a Leased Line trouble output, SW and SW on switch S must be set. These positions permit the default trouble bus to activate the trouble line. Refer to TABLE 3 to set them. 3. All wiring must be in accordance with Article 760 of NEC or local builsing codes. 4. Both Leased Line circuits are power limited to NFPA 70 per NEC Article 760. 5. Leased Line circuit rating: 4 VDC open circuit Load must be a compatible polarity reversal labeled remote station receiver unit. Rated current: 3mA to 9mA, alarm/supervisory External circuit resistance: K to 5K ohms 6. Minimum emergency power: 60 hour standby / 5 minute alarm

Notes:. Polarity shown in supervisory state.. Maximum line resistance 3 ohms. 3. Releasing zones are not power limited to NFPA 70 per NEC 760. 4. Releasing solenoids are supervised for opens only. Table Setting the Mode Of Operation (Using S3, S4 and G, G) For Circuit S3 Position G Audibles [NAC] (NFPA 7 Local) Municpal Tie (NFPA 7) Leased Line (NFPA 7 Remote Station) Releasing Service (NFPA A)** Releasing Service (NFPA3)** Releasing Service (NFPA 00)** Illegal (Results in a trouble on the CSM-4) For Circuit S4 Position G CSM-4 Loop Wiring for use as Releasing Service (per NFPA A, NFPA 3, and NFPA 00) ELECTRICAL CONNECTIONS FOR RELEASING SERVICE (per NFPA A, NFPA 3, and NFPA 00). Set all positions of switch S to OFF (OPEN). 3. All wiring must be in accordance with Article 760 of NEC or local building codes. 4. Both circuits are not power limited. 5. Solenoids are supervised for opens only. 6. Electrical Ratings: Solenoids: 4 VDC, 6.8 watts max, 700mA max Supervisory Current:mA max Alarm Current: 800mA max Wire Resistance: 3 ohms max 7. Compatible Solenoids: NFPA 3: ASCO Model T80A07 ASCO Model R80A07 ASCO Model 80A07 SKINNER Model LVLBX5 NFPA A: PYRO P/N 500-9863 PYRO P/N 500-8665 PYRO P/N 500-083377 PYRO P/N 500-08699 NFPA 00: KIDDE FENWAL Model 486500-8. No End of Line Device used. Audibles [NAC] (NFPA 7 Local) Municpal Tie (NFPA 7) Leased Line (NFPA 7 Remote Station) Releasing Service (NFPA A)** Releasing Service (NFPA3)** Releasing Service (NFPA 00)** Illegal (Results in a trouble on the CSM-4) ** Canada Only: Do not cut jumpers G and G for NFPA A, NFPA 3 and NFPA 00 Table 3 Setting the Degrade Trouble Modes on S Leased Line Trouble Note: If circuit or circuit is not used for leased line trouble, dipswitches SW or SW must be off (open). OFF (no default activation) For Circuit SW4 SW3 CONTINUOUS (active on default alarm) SEC ON, SEC OFF (infinite repeat) DO NOT USE For Circuit No Trouble Activation Leased Line Trouble For Circuit No Trouble Activation OFF (no default activation) For Circuit SW6 SW5 SW SW Table 4 Setting the Degrade Alarm Modes on S CONTINUOUS (active on default alarm) SEC ON, SEC OFF (infinite repeat) DO NOT USE Note: When circuits are used for leased line supervisory, the alarm default modes must be set to OFF (open)

MXL Releasing Service Wiring Diagram (per NFPA A, NFPA 3, and NFPA 00) Notes:. Use only listed solenoids from Table.. Solenoids supervised for opens only. 3. Polarity shown in supervisory condition. 4. Releasing circuits are not power limited. 5. No end of line device used. 6. Configure CSM-4 circuits as Municipal Tie. 7. Maximum of 5 Pre-Action/Deluge zones per MOM-4. 8. Each MOM-4 must be powered from a separate ALARM-SAF power supply. 9. Set all position of S on the CSM-4 ro OFF (OPEN). Table Application Make Model Maximum # per MOM-4 NFPA 3 (Preaction Deluge) NFPA A (Halon) NFPA 00 (FM-00) Skinner LVLBX5, 4V 5 ASCO TB0A07, 4V 5 ASCO R80A07, 4V 5 ASCO 80A07, 4V 5 CPY 500-9863, 4V 8 CPY 500-8665, 4V 8 CPY 500-083377, 4V 8 CPY 500-08699, 4V 8 CPY 500-486500 8

NOTICE: The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a misapplication of Cerberus Pyrotronics equipment and as such void all warranties either expressed or implied with regards to loss, damage, liabilities and/or service problems. Cerberus Pyrotronics 8 Ridgedale Avenue Cedar Knolls, NJ 0797 Tel: (0) 67-300 FAX: (0) 397-7008 Website: www.cerbpyro.com 5/97 0M CPY-IG Printed in U.S.A. Cerberus Pyrotronics 50 East Pearce Street Richmond Hill, Ontario L4B, B7 CN Tel: (905) 764-8384 FAX: (905) 73-98 May 997 Supersedes sheet dated 3/96