XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

Similar documents
XUX0AKSAM12 photo-electric sensor - XUX - multi - Sn 0..40m VDC - M12

XUM0APSAM8 photo-electric sensor - XUM - multi - Sn 0..10m VDC - M8

XVUC29 Ø60mm LED unit - steady/flash/rotate, multicolor unit, IP65, 24VAC/DC

Series Description. Features. Available Models. Specifications. Specifications for All Models. Specifications for Standard Models

culus and CE Marked for all applicable directives Operating Environment Operating Temperature [C (F)]

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Retro-reflective Sensing range: 0mm to 2000mm

5.0. Photoelectric Sensors. Technical Reference. Introduction

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Class 1 laser beam sensor safe for your eyes

SENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -

Overload relays. General descriptions. Configuration of the front

Retroreflective sensor with polarization filter

Retroreflective sensor with polarization filter

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Class 1 laser beam sensor safe for your eyes

Plug-in Base, Long Range Sensor E3B2

Class 1 laser beam sensor safe for your eyes

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

Laser Collimated Beam Sensor

M7100 Pressure Transducer

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

200mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - 250V DC

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

UNIVERSAL COMPACT SENSORS

Safety Light Curtains Area Access Control

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

E3M-V. Mark Sensor. Applications

Gas cylinder scale Model GCS-1

Throughbeam photoelectric sensor for the detection of aqueous liquids. Dimensioned drawing

onlinecomponents.com

160W High Intensity UV LED Light - UVA/365NM V AC - Acrylic Lens

GuideLine 2. Highly Visible Alignment Lasers for Visually Demanding Surfaces

BOS 23K. Photoelectric Sensors BOS 23K

50mW Red Crane Warning Laser - Red Pedestrian Safety Laser - 120/277V AC - IP54 Rated

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

OWNERS MANUAL OPERATION GUIDE

Technical Data. Dimensions

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

5mW Red Crane Warning Laser - Red Pedestrian Safety Laser - Projects Red Line on Floor - IP54

M5200 Industrial Pressure Transducer

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

NLC C61 Air-Cooled Argon-ion Laser

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Technical Data. Dimensions

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

E3FA PHOTOELECTRIC SENSORS

M5800 Pressure Transducer with Rotatable Display

Vibracon LVL-A* Level limit switch for liquids, compact design

M5800 Pressure Transducer with Rotatable Display

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Online data sheet WS/WE45-P260S01 W45 PRODUCT PORTFOLIO

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Technical Data. Dimensions

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

CR Series Command Relays

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Technical Data. Dimensions

More Precision. thicknesssensor // The sensor for precise thickness measurements

Vacuum suction nozzle OVEM-...-1P/1N

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

02/11/2015

OG-Cube Photoelectric Sensors Optical sensing technology

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Sensing light curtain as per DIN 18650/EN 16005

PHOTOELECTRIC AMPLIFIER SERIES

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

U5300 Industrial Pressure Transducer

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Synchronous Detector

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

optris Outdoor protective housing

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Adjustable Range Reflective Photoelectric Sensor. panasonic.net/id/pidsx/global

M12 Class 2 Laser Emitter

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

2 General Application Photoelectric Sensors

Sensing light curtain as per DIN 18650/EN 16005

ISIS SAFETY SYSTEM Installation guide

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

Ultrasonic Proximity Sensor

Transcription:

Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply voltage Supply voltage limits Switching capacity in ma Switching frequency Voltage drop Current consumption Power consumption in W Delay first up Delay response Delay recovery Setting-up Product weight Kit composition Main Range of product Series name Electronic sensor type Sensor name Sensor design Detection system Material Type of output signal Supply circuit type Wiring technique Discrete output type Discrete output function Electrical connection Cable length Emission [Sn] nominal sensing distance PBT PMMA 0 mm Solid state OsiSense XU Application material handling Photo-electric sensor XUB Cylindrical M18 Thru beam Plastic Discrete DC 3-wire PNP 1 NO or 1 NC programmable Cable 2 m Red laser (class 1), wavelength: 670 nm conforming to IEC 825-1 100 m 1 LED (green) for supply on and teaching 1 LED (red) for stability 1 LED (yellow) for output state and alignment aid 12...24 V DC with reverse polarity protection 10...30 V DC <= 100 ma (overload and short-circuit protection) 1500 Hz <= 1.5 V (closed state) 25 ma (no-load) < 1 W < 80 ms < 0.4 ms < 0.4 ms With sensitivity adjustment 0.18 kg Transmitter + receiver XUBLAKCNL2T + R The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Jun 15, 2017 1

Environment Product certifications CE CSA UL Ambient air temperature for operation -10...45 C Ambient air temperature for storage -40...70 C Vibration resistance 7 gn, amplitude = +/- 0.75 mm (f = 10...55 Hz) conforming to IEC 60068-2-6 Shock resistance 30 gn (duration = 11 ms) conforming to IEC 60068-2-27 IP degree of protection IP67 (double insulation) conforming to IEC 60529 Offer Sustainability Sustainable offer status RoHS (date code: YYWW) Product environmental profile Product end of life instructions Not Green Premium product Compliant - since 0901 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity Available Product Environmental Available End Of Life Manual Contractual warranty Warranty period 18 months 2

Dimensions Drawings Dimensions Dimensions 3

Mounting and Clearance Mounting Adjustment (1) Adjust the focusing point of the laser beam by rotating the serrated sleeve (2) Located on the face of the sensor. Re-tighten fixing screws 4

Connections and Schema Wiring Schemes PNP Transmitter (+) Brown BN : (-) Blue BU : (Output) Black BK : Input Not connected: beam made, connected to (-): beam broken 2/VI : 5

Performance Curves Curves Detection Curve (Set to Infinity) Excess Gain Curve (X) (Y) Distance (m) Gain Standard Curve (X) (Y) Distance focusing point (m) Minimum size of the object to be detected (mm) 6

Detection Limit Curve (X) (Y) Distance focusing point (m) Minimum size of the object to be detected (mm) 7