Gas expansion thermometer

Similar documents
Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Mounting and Operating Instructions EB 2231 EN

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

SECTION METERS AND GAGES FOR HVAC PIPING

Indoor/outdoor resistance thermometer Model TR60

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SECTION METERS AND GAGES FOR PLUMBING PIPING

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Gas cylinder scale Model GCS-1

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

INSTRUCTIONS CertoClav EL

Thermometers with capillary tube. Bimetal thermometers. Industrial thermometers. Resistance thermometers

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Blue Ribbon Corporation

PROFIBUS-PA Display RID 261 PROFIBUS-PA

FAST RESPONSE TEMPERATURE SENSORS 42.11a

B. Product Certificates: For each type of meter and gage, from manufacturer.

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

Druck DPI 705/DPI 705 IS Series

Temperature Measurement Transmitters for field mounting

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Technical Data. Dimensions

BINDER Scientific Product Catalog

Model 144H. Product Data Sheet , Rev DB February Content

Constant climate chamber with ICH-compliant illumination

Safety vacuum drying oven for flammable solvents

MEASUREMENT TECHNOLOGY. Pressure and Temperature Measurement

Model 144H. Product Data Sheet , Rev DB February Content

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Temperature Sensor TRG Original Installation Instructions English

Constant climate chamber with humidity

OEM Sensors for HVAC manufacturers Heat recovery Chiller

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Beck. The differential pressure transmitter for air

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Mounting and Operating Instructions EB 5206 EN. Thermostats. Type 5343 Safety Temperature Monitor (STM) Type 5344 Temperature Regulator (TR)

Environmental simulation chamber for complex alternating climate profiles

Rosemount 4500 Hygienic Pressure Transmitter. Start

Thermometers Installation, Operation and Maintenance WINTERS INSTRUMENTS. MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Technical Data. Dimensions

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Fan Heaters Type VLEx

Rosemount 248 Temperature Transmitter

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

1. Division 23 Section "Steam and Condensate Heating Piping" for steam and condensate meters.

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

SECTION METERS AND GAUGES FOR HVAC PIPING

Aspirations-Psychrometer Assmann Model / 000

Oil & Gas Oil & Gas. Control Control. every move. Directional Control Valves & Regulators Pressure Controls Temperature Switches Level Controls

Operating Instructions SIPLUS CMS4000 MCN11. Preface 1. Product Overview 2 SIPLUS CMS4000. Installation 3. Media Converter Node (MCN11) Wiring 4

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Oil & Gas Oil & Gas. Control. every move. Directional Control Valves & Regulators Pressure Switches Temperature Switches Level Switches

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

Rosemount 2090F Hygienic Pressure Transmitter

Installation and Operating Instruction

-REOTEMP s TC/RTD Background - Field Solutions - Product Overview -The REOTEMP difference

Flow Switches. Series VHS, VKS, VH

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Inductive slot sensor

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Rosemount 2090F Hygienic Pressure Transmitter

Grohtherm Grohtherm 1000

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Certificate: / 29 April 2014

MANUAL Oil Level Sensor

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

Rosemount 248 Temperature Transmitter

MANUAL Overflow sensor NVF-104/34-PF

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

Analog Transmitter AT1000 AT1

Sitron s CF Line of Flow Switch Monitors

Certificate: / 9 February 2011

Datasheet - AZM 161SK-12/12RK-024

BIMETAL THERMOMETERS Universal Mount All Star Adjustable Union All Pro Replaceable Element Slip-Fit 3A Sanitary Surface Thermometers Thermowells

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

LTFX Electric Tank Immersion Heaters Installation Instructions

Exp, pressurized systems

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Transcription:

Gas expansion thermometer Type series FN. Features High quality case with bajonet ring /160, degree of protection IP 66 Nominal ranges -40 C 700 C, further nominal ranges from -200 C...700 C upon request Case and wetted parts of stainless steel Different connections can be supplied Temperature detecting element 6, 8 and 10 mm diameter Short immersion lengths of the temperature detecting element may be used Accuracy class 1 as per EN 13190 Micro adjusting pointer for indication correction EAC declaration (upon request) Options Approvals/Certificates - Explosion protection (ATEX) for mechanical devices - Certificate of measuring equipment for Russian Federation - Calibration certificate as per EN 10204 Case with liquid filling Electronical angle-of-rotation sensor, Type series PL1100, see data sheet D6-020 Connection to zone 0 with thermowells (upon request) Application area Shipping Machinery construction Chemical and petrochemical industry General process technology Application These thermometers are suitable for use outdoors and in aggressive environments. The devices can also be supplied with additional liquid damping for use in extreme conditions. Suitable thermowells see product group T5. Technical data Constructional design / case Design: High quality case with bajonet ring, material: stainless steel mat.-no. 1.4301 (304) Nominal size: or NS 160 Degree of protection per EN 60529: Case filling: IP 66 Labofin Further filling liquids upon request. Window: Movement: Scale: Pointer: Non-splintering laminated glass. Option: non-splintering plastic (Macrolon) with adjustable reference pointer Stainless steel with compensation Pure aluminium, white with black inscription. Alternatively with marking or fixed reference pointer. Pure aluminium, black with micro adjustment for zero point correction Case seal: Material gasket: NBR

Weights: Bottom or centre back connection Nominal range : without filling: with filling: NS 160: without filling: approx. 0.6 approx. 0.8 approx. 1.1 Nominal range (EN 13190): -40 700 C Measuring spans 60 C, see order details Further nominal ranges from -200 C up to 700 C (no normal range) upon request. with filling: Adjustable angel stem approx. 1.9 Without screwing and temperature detecting element Accuracy Accuracy class: 1.0 per EN 13190 Process connection Design: Measuring element Measuring element: Temperature sensor Temperaturedetecting element: : without filling: approx. 1.0 with filling: approx. 1.2 NS 160: without filling: approx. 1.4 with filling: approx. 2.0 rigid temperature detecting element, bottom connection. rigid temperature detecting element, centre back connection. rigid temperature detecting element, adjustable angle stem, latching every 20. Various process connections can be supplied (see order details). Bourdon tube, dead zone free with noble gas filling. Diameter 6, 8 and 10 mm. Standard lengths and active lengths see order details, further sizes upon request Material: stainless steel mat.-no. 1.4404 (316L) Temperature ranges Ambient: Per EN 13190. Storage and transport: Ambient temperatures that deviate from EN are to be specified. -20 60 C Tests and certificates Explosion protection: Further temperature ranges upon request. Ex- protection (ATEX) for mechanical devices II 2G c TX II 2D c TX Further details and temperature limits see Ex Instruction XA_005. EAC declaration (upon request) Certificate of measuring equipment for Russian Federation Instructions for use The loading capacity of the temperature detecting element depends on the following parameters: Media Media pressure Media temperature Flow velocity Insertion length Material A technical examination might be necessary as well as the use of a separate thermowell (Product group D5). Information on other models see order details or upon request. Further information to mounting and operation see Operating Instruction BA_017.

Dimensions Dimensions bottom and centre back connection Temperature detecting element diameter d5, insertion length l1 and active length l2 see order details. Dimensions (mm) h * see order details t * see order details case d1 b a D1001 D1107/1109/1122 D1207 D2007 D2009 D1001 D1107/1109/1122 D1207 D2007 D2009 100 59 15 98 83 98 98 98 108 93 108 108 108 NS 160 160 60 15 128 113 128 128 128 108 93 108 108 108 * For nominal ranges 160 C dimension increases by 36 mm. Dimensions adjustable angle stem Temperature detecting element diameter d5, insertion length l1 and active length l2 see order details. Dimensions (mm) z * see order deatails case d1 b g D1001 D1107/1109/1122 D1207 D2007 D2009 100 59 92 83 68 83 83 83 NS 160 160 60 92 83 68 83 83 83 * For nominal ranges 160 C dimension increases by 36 mm.

Dimensional drawing of process connections for bottom connection, centre back connection and adjustable angle stem

Gas expansion thermometer Type series FN. Order details FN. FN2400 FN3400 NS 160 bottom connection FN2600 FN3600 NS 160 FN2300 FN3300 case design NS 160 centre back connection FN2500 degree of protection IP 66 FN3500 NS 160 FN2310 FN3310 NS 160 adjustable angel stem FN2510 FN3510 NS 160 without liquid filling with liquid filling without liquid filling with liquid filling without liquid filling with liquid filling nominal ranges A2340-20...40-10...30 A2346-20...60-10...50 A2322-30...50-20...40 A2220-40...40-30...30 A2222-40...60-30...50 A2520 0...60 10...50 A2522 0...80 10...70 A2524 standard ranges [ C], 0...100 10...90 accuracy class 1 A2540 per EN 13190 0...120 20...100 A2544 0...160 20...140 A2548 0...200 20...180 A2560 0...250 30...220 A2565 0...300 30...270 A2627 0...400 50...350 A2630 0...500 50...450 A2640 0...600 100...500 A2650 0...700 100...600 D1107 D1109 D1122 shank, fixed D1207 process connection shank, rotating G1/2 B D2007 G1/2 union nut D2009 G3/4 D1001 without screwing F6 6 mm (l2 180 mm) 1 F8 temperaturing detecting element Ø d5 8 mm (l2 80 mm) 1 F10 10 mm (l2 50 mm) 1 D11.. shank fixed D1207 shank rotating G1/2 B measuring ranges G1/2 B G3/4 B D2007 union nut G1/2 1/2 NPT D2009 union nut G3/4... 100 080 089 093 100... insertion lenght l1 (mm) 2 160 140 126 130 160... 250 230 186 190 250... 400 380 276 280 400... - - 426 430-999 deviating length; please specify D1001 without screwing LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com

Additional features (to be indecated if required) S30 Ex-protection (ATEX) for mechanical devices 3 II 2G c TX II 2D c TX R13 window macrolon with adjustable reference pointer 4 T2 on scale (please specify) marking T3 fixed reference pointer (please specify) W1204 per EN 10204-3.1, 3 measuring points calibration certificate W1201 per EN 10204-3.1, 5 measuring points W2673 certificate of measuring equipment for Russian Federation 4 Order code (example): FN2400 - A2524 - D1107 - F6100 -... 1 the active length l2 shall reach the media temperature completely. The insertion length l1 should have adequate size. 2 standard insertion length to be specified in order code, e.g. Ø d5= 6 mm, l1 = 100 mm: order code F6100 3 within the temperature limits according to Ex instruction XA_005 4 not for devices with Ex-protection LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Phone: +49 (0) 4408 804-0 Fax: +49 (0) 4408 804-100 e-mail: info@labom.com www.labom.com