Remote Control Operation Manual Split Type Air Conditioner

Similar documents
HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM. Quick-Start Guide ON/OFF TEMP MODE SILENCE FP FAN SPEED SWING TIMER ON SWING TIMER OFF SLEEP

SYSCONTROL RM 52. SYSPLIT Type Remote controller user manual CR090 RG52A A

CR034-RG36F

REMOTE CONTROL MANUAL

AIR CONDITIONER REMOTE CONTROLLER MANUAL

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

DVC/DVH 09/12/18/24 Series

CONTENTS ,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons...

,,,,,, ,,,, Remote controller Specifications Operation buttons Indicators on LCD How to use the buttons Auto operation...

USER MANUAL MIDEA FAIRWIND

Remote Control User Manual

SPLIT-TYPE ROOM AIR CONDITIONER

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR004-RG35/

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR054-RG51B

REMOTE CONTROLLER CR057-RG51Q&J MANUAL

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

SET TEMPERATURE( F) AUTO COOL DRY HEAT TEMP MODE SWING RESET LOCK LED DISPLAY

VMH 09/12/18/24 SD Series Inverter Single Zone Ductless Mini-Split

Portable Room Air Conditioner Remote Control for:

CR166-RG57A6EU- 6 INFRARED WIRELESS MULTI FUNCTION REMOTE CONTROLLER OWNER S MANUAL

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CR137-RG51F

SERIES AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION

Thank you very much for purchasing our air conditioner. Please read this owner's manual carefully before using your air conditioner.

A IR CONDITIONE R REMOTE CONTROLLER ILLUSTRATION CR087-RG05F2EU

Remote Control Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

OWNER S & INSTRUCTION MANUAL

CR193-RG70E2(2)BGEU

Remote Control Instructions

Remote Controller Manual

REMOTE CONTROLLER OWNER S MANUAL

Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

REMOTE CONTROL MANUAL

Owner's Manual TABLE OF CONTENTS

WA-1240E: 12,000 BTU Cooling only WA-1240H: 12,000 BTU Cooling and Heating WA-1420E: 14,000 BTU Cooling only WA-1420H: 14,000 BTU Cooling and Heating

Remote Control Features & Functions. (78) Symphony Solo Series Remote Control USERS GUIDE

Owner's Manual TABLE OF CONTENTS

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Owner s Manual TABLE OF CONTENTS

Inverter Air Conditioner User Manual KSV25HRH, KSV35HRH, KSV50HRH, KSV71HRH, KSV90HRH, KSD25HRH, KSD35HRH, KSD50HRH, KSD71HRH, KSD90HRH

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

USER S MANUAL. Remote Controller 88-MACC007-1A-EN

REMOTE CONTROLLER KSWM units

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Hi Wall Split Air Conditioners

Slim Line Ceiling Concealed Ducted Split Systems

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

DLFEHA. OWNER S MANUAL High Wall Ductless System Sizes 09 to 24 TABLE OF CONTENTS

Owner s Manual Split Type Wall Mounted Air Conditioner

Remote Controller. <Open the front cover> <ARC452A4>

Spectrolink Comfort Control. Home Owner's Manual Heating

Owner s Manual TABLE OF CONTENTS

2. Pictographs 2.1 Basic Operation

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

High Wall Split Air Conditioners 53QHCT KHCT

Portable Air Conditioner Instruction Manual

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

CR103-RG57A3. REMOTE CONTROLLER ILLUSTRATION (Function selection)

USER'S OPERATING INSTRUCTIONS

HOME OWNER S MANUAL. Spectrolink Comfort Control - Heating

PORTABLE AIR CONDITIONER

WIRED CONTROLLER MANUAL

Inverter Split System Room Air Conditioner User Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE

Owner s Manual TABLE OF CONTENTS

Buttons on remote controller

AM/FM Clock Radio User Manual

Operating Functions Temperature Parameters

Owner s Manual TABLE OF CONTENTS

WORKING PROGRAM. Heating dehumidifying cooling T 27

ENGLISH REMOTE CONTROL MANUAL

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

BTU Units WORKING PROGRAM MANUAL

INVERTER SPLIT - TYPE ROOM AIR CONDITIONER

53 KNL / 53 QNL OWNER S MANUAL

CR2003 ROBERTS. 3 band Auto set PLL Synthesised Clock Radio. Sound for Generations. Please read this manual before use

OWNER S MANUAL. Split Air Conditioner

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

AF-Q100VX AF-Q120VX AF-Q100VX, AF-Q120VX) 15%

Operation Manual Split Type Wall Mounted Air Conditioner Models: RINV25RC / RINV34RC / RIN51RC / RINV70RC

OWNER S MANUAL. Split Air Conditioner IVIH121A / OVIH121A IVIH241A / OVIH241A IVIH361A / OVIH361A

HMCI 125F-EH MOVABLE TYPE AIR CONDITIONER WITH OZONE-FRIENDLY R410A REFRIGERANT USER S MANUAL CAUTION:

SAT-3 Room Temperature Controller

CASSETTE TYPE

Q Series. Inverter Split Systems

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

42XQ 42XQA. 42XQ : Cooling only direct expansion Fan Coil Unit (Wireless Control) 42XQA : Cooling only direct expansion Fan Coil Unit (Wired Control)

WINDOW / WALL-TYPE ROOM AIR CONDITIONER

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

15,000 BTU Portable Air Conditioner

Operating Instructions Air Conditioner

SC-305/9H. SPLIT TYPE AIR CONDITIONER Instruction manual

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

Owner s Manual TABLE OF CONTENTS

Kelvinator Air Conditioning front/rear view 1

Operation Manual Split Type Wall Mounted Air Conditioner

Using the Remote Control Unit

R9968 ROBERTS. Analogue World Radio. Sound for Generations. Please read this manual before use

RC3-LCD remote control

Transcription:

Remote Control Operation Manual Split Type Air Conditioner cool SET. - + To Suit Models Wall Mounted Cassette HINRA6M CIN050A HINRA5M CIN00A HINRA50M CIN00A HINRA0M CIN0A HINRA0 CIN40A Head Office Australia Pty. Ltd. ABN 4 005 6 00 Atlantic Drive Keysborough VIC P.O. Box 460 Braeside Victoria 5 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service please call our National Help Line. Rinnai recommends that this appliance be serviced once a year. Product Sales and Service - National Phone: 00 555 545* Fax: 00 555 655* Technical Helpline and Spare Parts National (Mon-Fri am - 5.0pm EST) Phone: 00 555 545* Fax: 00 00 4* *Cost of a local call higher from mobile or public phones. E-mail: enquiry@rinnai.com.au For further information visit: www.rinnai.com.au Part Number: B060 December 06 EQPL5655 Issue A This appliance shall be installed in accordance with: Manufacturer s Installation Instructions Current AS/NZS 000 Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained accordance with the manufacturer s instructions.

DIRECT FRESH CTENTS Handling the Remote Control... Remote Control Specifications... Function Buttons...... 5 Handling the Remote Control m Location of the remote control. Use the remote control within a distance of meters from the appliance pointing it towards the receiver. Reception is confirmed by a beep. Indicators on LCD... System Operation... Auto Operation... Cooling/Heating/Fan Operation... Dehumidifying (DRY) Operation... Adjusting Air Flow Direction... Timer Operation... 0 CAUTIS The air conditioner will not operate if curtains doors or other materials block the signals from the remote control to the indoor unit. Prevent any liquid from falling into the remote control. Do not expose the remote control to direct sunlight or heat. If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver. If other electrical appliances react to the remote control either move these appliances or consult your local dealer. Replacing Batteries The remote control is powered by two AAA batteries housed under the removable rear cover. () Remove the cover by pressing and sliding off. () Remove the old batteries and insert the new batteries placing the (+) and (-) ends correctly. () Reattach the cover by sliding it back into position. NOTE: When the batteries are removed the remote control erases all programming. After inserting new batteries the remote control must be reprogrammed. CAUTIS Do not mix old and new batteries or batteries of different types. Do not leave the batteries in the remote control if they are not going to be used for or months. Do not dispose batteries as unsorted municipal waste. Batteries can be taken to specialist waste transfer stations.

Remote Control Specifications Function Buttons Model RG6F5/BGEF Button Operation starts when this button is pressed and stops when this button is pressed again. Rated Voltage Signal Receiving Range Environment Performance Features.0V( x AAA.5 Volt Batteries). Operating Modes: AUTO COOL DRY HEAT and.. Timer Setting Function in 4 hours.. Indoor Setting Temperature Range : C~0 C. 4. Full function LCD (Liquid Crystal Display). NOTE: m -5 C ~ 60 C Remote control button design may be slightly different from the one supplied depending on the individual model All the functions described are associated with the relative indoor unit. If the indoor unit does not have a particular feature there is no corresponding operation performed by the indoor unit. 4 5 6 0 4 5 Button Each time the button is pressed the operation mode is selected in a sequence as follows: AUTO COOL DRY HEAT Swing Button Used to stop or start horizontal louver movement or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If pressed for more than seconds the louver will swing up and down automatically. 4 Swing Button Used to stop or start vertical louver movement and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press. And the temperature display area of indoor unit displays for one second. If pressed for more than seconds the vertical louver swing feature is activated. And the display area of indoor unit displays IIII flashes four times then the temperature setting reverts back. If the vertical louver swing feature is stopped it displays LC and remains on for seconds. 5 Button Active/Disable sleep function. It maintains the most comfortable temperature and saves energy. For details see operation in USER S MANUAL. NOTE: While in mode the mode is cancelled when the or buttons are pressed. 4

Function Buttons 4 5 6 0 4 5 6 / Button: Press this button to initiate the function. Press and hold this button for more than seconds and the function is initiated. When the Follow Me function is activated the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner at minute intervals until you press the button again. The Follow Me function is not available under DRY and mode. Switching the operational mode or turning off the unit will cancel the function. + UP Button ( ) Press this button to increase setting temperature or to increase Hours during Timer setting. DOWN Button ( - ) Press this button to decrease setting temperature or to decrease Hours during Timer setting. 0 Button: When you press the recessed button all current settings are cancelled and the control will return to the initial settings. Button Used to restore the current settings or resume previous settings. When first connected to power pressing the button will activate the AUTO O mode 4 C and fan speed is Auto. Pressing this button when unit is on the system will automatically revert back to the previous settings including operating mode setting temperature fan speed level and sleep feature (if activated). If pressed and held for more than seconds the system will automatically restore the current operation settings including operating mode setting temperature fan speed level and sleep feature (if activated). 4 5 6 0 4 5 4 Button Used to select the fan speed in four steps: AUTO LOW D HIGH Button Press this button to initiate the auto-on time sequence. Each press will increase the auto-timer setting in 0 minutes increments. When the setting time displays 0H each press will increase the auto-timer setting 60 minutes increments. To cancel the auto-timer program simply adjust the auto-on time to 0.0. Button Press this button to initiate the auto-off time sequence. Each press will increase the auto-timed setting in 0 minutes increments. When the setting time displays 0H each press will increase the auto-timer setting 60 minutes increments. To cancel the auto-timer program simply adjust the auto-off time to 0.0. / function Press this button to initiate the function. Press and hold this button for more than seconds and the function is initiated. When the Follow Me function is activated the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner at minute intervals until you press the button again. The Follow Me function is not available under DRY and mode. Switching the operational mode or turning off the unit will cancel the function. 5 Button When you press the recessed button all current settings are locked in and the remote control does not accept any operation except that of the. Press again to cancel the mode. 5 6

Indicators on LCD System Operation auto cool dry heat fan SET. silence sleep follow me lock run F Transmission Indicator This transmission indicator lights when remote control transmits signals to the indoor unit. Mode Display Displays the current operation mode. Including auto( ) cool( ) dry( ) heat( ) fan ( ) and back to auto ( ). Temp./Timer Display O O Displays the temperature setting( C~0 C). When you set the operating mode to no temperature setting is displayed. If in mode shows the and settings of the. Fan Speed Display Displays the selected fan speed AUTO (no display) and three fan speed levels " " (LOW) " " (D) " " (HIGH) can be indicated. The fan speed is AUTO when the operating mode is either AUTO or DRY. Display Displayed by pressing the button. Press the button again to change. Auto Operation Ensure the unit is plugged in and power is available. The OPERATI indicator on the display panel of the indoor unit will start flashing.. Press the button to select Auto.. Press the UP/DOWN button to set the desired temperature. The temperature can O O O be set within a range of C~ 0 C in C increments.. Press the button to start the air conditioner. NOTE. In the Auto mode the air conditioner will logically choose Cooling Fan or Heating mode by sensing the difference between the actual ambient room temperature and the set point temperature on the remote control.. In the Auto mode you can not control the fan speed. It is automatically controlled by the unit.. If the Auto mode is not comfortable for you set the desired mode manually. Cooling /Heating/Fan Operation Lock Display Displayed when mode is activated. Display Displayed when function is activated. Sleep Display Displayed during mode. Press the button again to exit mode. Silence Display (where fitted) Displayed when SILENCE function is activated. Note: All indicators shown in the figure are for the purpose of presentation. During the actual operation of the remote control only the relative functional signs are shown in the display window. 4 Ensure the unit is plugged in and power is available.. Press the button to select COOL HEAT or mode.. Press the UP/DOWN buttons to set the desired temperature. The temperature can O O O be set within a range of C~ 0 C in C increments.. Press the button to select the fan speed in four steps- Auto Low Medor High. 4. Press the button to start the air conditioner. NOTE In the mode the temperature setting is not displayed on the remote control and you are unable to control the room temperature. In mode only steps and 4 may be performed.

Dehumidifying (DRY) Operation Ensure the unit is plugged in and power is available. The OPERATI indicator on the display panel of the indoor unit starts flashing.. Press the button to select DRY mode.. Press the UP/DOWN buttons to set the desired temperature. The temperature O O can be set within a range of C~ 0 C O in C increments.. Press the button to start the air conditioner. NOTE In Dehumidifying mode you can not control the fan speed. It is automatically controlled by the unit. Adjusting Air Flow Direction Use the and buttons to adjust the desired airflow direction.. Press the button and the horizontal louver changes 6 degree in angle for each push. Press and hold for more than seconds and the louver will automatically swing up and down.. Press the button and the vertical louver changes 6 degree in angle for each push. Press and hold for more than seconds and the louver will automatically swing left and right. NOTE: When the horizontal/vertical louver swing moves to a position which may affect the cooling or heating effect of the air conditioner it may automatically change the horizontal or vertical position. Timer operation Press the button to set the auto-on time of the unit. Press the button to set the auto-off time of the unit. To set the Auto-on time.. Press the button. The remote control shows the last Auto-on setting time and the signal "H" will be shown in the LCD display area. Now it is ready to reset the Auto-on time to the START time.. Press the button again to set desired Auto-on time. Each time you press the button the time increases by half an hour between 0 and 0 hours and by one hour between 0 and 4 hours.. After setting the function there will be a one second delay before the remote control transmits the signal to the air conditioner. Then after approximately another seconds the signal "H" will disappear and the set temperature will re-appear in the LCD display window. To set the Auto-off time.. Press the button. The remote control shows the last Auto-off setting time and the signal "H" will be shown in the LCD display area. Now it is ready to reset the Auto-off time to stop time.. Press the button again to set desired Auto-off time. Each time you press the button the time increases by half an hour between 0 and 0 hours and by one hour between 0 and 4 hours.. After setting the function there will be a one second delay before the remote control transmits the signal to the air conditioner. Then after approximately another seconds the signal "H" will disappear and the set temperature will re-appear in the LCD display window. 0

! CAUTI The effective operation time set by the remote control for the timer function is limited to the following settings: 0.5.0.5.0.5.0.5 4.0 4.5 5.0 5.5 6.0 6.5.0.5.0.5.0.5 0 4 56 0 and 4. Example of timer setting Set Off Start 6 hours later (Auto-on Operation) The feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time. Example: To start the air conditioner in 6 hours.. Press the button the last setting of starting operation time and the signal "H" will show in the display area.. Press the button to display "6.0h" on the display of the remote control.. Wait for seconds and the digital display area will show the temperature again. The " " indicator remains on and this function is activated. On Set On Set hours later after setting Stop 0 hours later Stop Start 0 hours later after setting (Auto-off Operation) The feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time. Example: To stop the air conditioner in 0 hours.. Press the button the last setting of stopping operation time and the signal "H" will show in the display area.. Press the button to display "0h" on the display of the remote control.. Wait for seconds and the digital display area will show the temperature again. The " " indicator remains on and this function is activated. COMBINED (Setting both and timers simultaneously) (On Stop Start operation) This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home. Example: To stop the air conditioner hours after setting and start it again 0 hours after setting.. Press the button.. Press the button again to display.0h on the display.. Press the button. 4. Press the button again to display 0h on the display. 5. Wait for seconds and the digital display area will show the temperature again. The " " indicator remains on and this function is activated.

Set Off hours later after setting Start Stop 5 hours later after setting (Off Start Stop operation) This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house. Example: To start the air conditioner hours after setting and stop it 5 hours after setting.. Press the button.. Press the button again to display.0h on the display.. Press the button. 4. Press the button again to display 5.0h on the display. 5. Wait for seconds and the digital display area will show the temperature again. The " " indicator remains on and this function is activated. NOTE: The timer setting ( or ) that occurs directly after the set time will be activated first. This page is intentionally blank 4