FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

Similar documents
FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

SINGLE-ROOM HEAT AND ENERGY RECOVERY UNITS

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KOMFORT EC DB Suspended heat recovery air handling units

SINGLE-ROOM VENTILATION. for schools and public spaces

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Series VENTS VUT R WH ЕС

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

10-year industry best core warranty. 5-year warranty on balance of unit.

TECHNICAL SPECIFICATIONS

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

AIR HANDLING UNIT WITH HEAT RECOVERY

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Residential Heat & Energy Recovery

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

COMMERCIAL VENTILATION

TURBO HOODS. Product Brochure

Ventilation Unit Zehnder ComfoAir 350

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

Outside Air Requirements... SOLVED!

The Sentinel Kinetic Horizontal Range

Heat recovery unit RDKS

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

PRODUCT RANGE: ROOFTOP PACKAGE

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Lo-Carbon Sentinel Kinetic Horizontal

Small Room Heat Recovery Ventilation

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

SINGLE-ROOM ENERGY RECOVERY VENTILATORS

Overview and Specifications

Ventilation unit Zehnder ComfoAir 200

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

MODELS TR & TRC TOTAL RECOVERY FOR ALL CLIMATES RESIDENTIAL OR COMMERCIAL APPLICATIONS

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

BROAN ERVS100 Part no. ERVS100S CFM (0.4 in. w.g.)

Limited Lifetime core warranty. 5-year warranty on balance of unit.

Caution: The fans must not be used in bath or shower enclosures.

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

UV-TURBO HOODS. Product Brochure

ENERGY RECOVERY VENTILATOR

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Description of components and operating logic of the unit MICRA Ventilation system arrangement example based on the unit MICRA 60...

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Flexit air handling units C2 and UNI 2, 3,4

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Domestic fans. Circular duct fans 1. Rectangular duct fans 2. Roof fans 3. Axial fans 4. Smoke evacuation fans 5.

Flexit air handling units UNI 2, 3 og 4

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Heat and energy recovery ventilators

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

HEAT RECOVERY AIR HANDLING UNIT

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

HEAT RECOVERY VENTILATOR

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Residential and Commercial HRVs & ERVs. Heat Recovery Ventilators & Energy Recovery Ventilators

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

HRV / ERV. Heat or Energy Recovery Ventilation Systems. You need fresh air, so does your home.

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

Air handling units with an integrated heat pump and rotary heat exchanger

G Installation manual Solitude - dmev unit

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

HRV Enthalpy. Catalogue

Heat Recovery Air Handling Units

Zehnder ComfoAir 550. Ventilation unit

TSEK VHR EC HEAT RECOVERY UNITS

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

VERTICAL FAN COIL UNITS

TR Series - The Ultimate ERV

Energy Recovery Total Recovery Ventilators. Balanced Ventilation for Residential and Commercial Buildings. Advancing Ventilation

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Transcription:

Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 %

2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed spaces. Low-energy EC fans. Silent operation. Supply air purification ensured by two built-in MERV8 and MERV14 filters (optionally HEPA filter). Upgradeable with an exhaust duct to provide air extraction from the bathroom. Easy installation. Compact size. Air flow: up to 59 CFM 28 l/s Heat recovery efficiency: up to 96 % Design Polymer coated metal casing decorated with an acrylic front panel. Heat and noise insulation is ensured by a layer of 10 mm cellular synthetic rubber. The front panel provides convenient access for filter maintenance and has a lock for extra security. The unit has two Ø3 15/16" pipes for fresh air intake and stale air extraction outside. The third Ø3 15/16" pipe (included in the scope of delivery) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom. Fans The units feature efficient electronically commutated (EC) motors with an external rotor and impellers with forward curved blades. These state-ofthe-art motors are the most advanced solution in energy efficiency today. EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %. MERV8 Extract filter Supply fan Plug MERV14 supply filter Counter-flow heat recovery core Lock MERV8 intake air filter Control panel Control unit Exhaust fan Supply air shutters with automatic actuator Exhaust air shutters with automatic actuator Drain pan Designation key Model Nominal air flow [m³/h] Heat exchanger core type Color Freshbox 100 _: standard type ERV: enthalpy type _: white casing Black: black casing 2

Air dampers The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off. Air filtration Supply air cleaning is provided by the MERV8 and MERV14 panel filters (PM2.5 > 75 %). To meet more stringent air purity requirements the MERV14 filter can be replaced with an HEPA Filter type C (PM2.5 > 95 %) (purchased separately). Exhaust air is cleaned by the panel filter MERV8. Operating principle The cold outdoor air passes through the filters and the heat exchanger and then is delivered to the serviced space by the supply centrifugal fan. Warm stale air from indoors passes through the filter and the heat exchanger and is discharged outdoors by the centrifugal fan. The supply and exhaust air flows are fully separated which helps eliminate the possibility of odour or microbial transfer between the streams. Heat and energy recovery The Freshbox 100 units are equipped with a counter-flow heat recovery core with a polystyrene core. In the cold season the exhaust air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses. Some condensate may form during heat recovery. The condensate is collected in the drain pan and is removed from the exhaust air duct. In the warm season the intake air heat is transferred to the extract air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load. The Freshbox 100 ERV units are equipped with a counter-flow energy recovery core with an enthalpy membrane at the core. In the cold season the exhaust air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses through ventilation. Consequently, it is the intake air heat and moisture transferred to the extract air stream through the enthalpy membrane in the warm season. This allows for a considerable reduction of the supply air temperature and humidity which, in turn, reduces the air conditioning load. From indoor To indoor Control The unit is equipped with a control panel. The remote control is supplied as standard. FUNCTIONS Freshbox 100 Freshbox 100 ERV To outdoor From outdoor Speed changeover Filter replacement indication From a bathroom Alarm indication To indoor Speed setting Timer To outdoor Weekly schedule FREEZE PROTECTION Freshbox 100 (ERV) features an exhaust air temperature sensor downstream of the heat exchanger which disables the supply fan to let the warm extract air warm up the heat exchanger. After that the supply fan is turned on and the unit reverts to the normal operation mode. Operating principle with extra spigot for bathroom exhaust ventilation SINGLE-ROOM HEAT RECOVERY UNITS 2018 3

2018 SINGLE-ROOM HEAT RECOVERY UNITS Technical data Parameters Freshbox 100 Freshbox 100 ERV Speed I II III I II III Voltage [V / 50 (60) Hz] 1~120 Max. power [W] 12 21 45 12 21 45 Max. current consumption [A] 0.35 Maximum air flow [CFM (l/s)] 18 (8) 35 (17) SFP [W/l/s] 1.44 1.26 1.62 1.44 1.26 1.62 RPM [min ¹] max 2200 Sound pressure level at 10 ft [dba] 13 27 39 13 27 39 Transported air temperature [ F] -13...+122 59 (28) 18 (8) 35 (17) 59 (28) Casing material polymer coated steel Insulation thikness [in] 3/8" Extract filter MERV8 Supply filter MERV8 + MERV14 (Option: MERV14 Carbon; HEPA Filter type C) Connected air duct diameter [mm] 100 Weight [lb] 68.3 Heat recovery efficiency [%]* 96 92 87 90 86 80 Heat recovery core type counter-flow Heat recovery core material polystyrene enthalpic membrane SEC class *Heat recovery efficiency is specified in compliance with EN 13141-8. A Sound power level, A-filter applied. Sound-power level, A - weighted General Octave frequency band [Hz] 63 125 250 500 1000 2000 4000 8000 Sound pressure level at 10 ft, A-filter applied Sound pressure level at 3 ft, A-filter applied L WA to environment [dba] 4000 45 40 44 38 33 29 27 22 28 38 Airflow [CFM] Airflow [CFM] Static pressure [Pa] 250 200 150 100 0 10 20 30 40 50 1 0,9 0,8 0,7 0,6 0,5 0,4 Static pressure [in W.G.] Sound pressure level @ 1 m, LpA [db(a)] 50 45 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 0 20 40 60 80 100 0,3 Airflow [m 3 /h] 50 0,2 0,1 0 0 0 20 40 60 80 100 Airflow [m 3 /h] Overall dimensions [in] 23 1/4" 7 7/8" Airflow [CFM] Recovery eff. [%] 0 10 20 30 40 50 100 95 90 85 80 75 0 20 40 60 80 100 7 7/8" 10 1/8" 3 15/16" 3 15/16" Freshbox 100 Freshbox 100 ERV Airflow [m3/h] 4

Accessories Name Description MS Freshbox 100 chrome Mounting kit: Two Ø 3 15/16" mm air ducts, 500 mm long Ventilation outer hood made of polished steel Cardboard template MS Freshbox 100 white Mounting kit: Two Ø 3 15/16" mm air ducts, 500 mm long Ventilation outer hood, painted white Cardboard template AH Freshbox 100 chrome Ventilation outer hood made of polished steel. AH Freshbox 100 white Ventilation outer hood, painted white EH Freshbox 100 Heater to prevent condensate freezing in the drain pipe and outer ventilation hood FP 193x158x18 G4 PPI MERV8 Filter FP 193x158x47 F8 MERV14 Filter FP 193x158x47 F8 C MERV14 Carbon Filter FP 193x158x47 H13 HEPA Filter type C HR-S Humidity sensor CD-1 CO2 Sensor with LED lights for indication of CO2 concentration and a touch button for operation mode switching CD-2 CO2 Sensor SINGLE-ROOM HEAT RECOVERY UNITS 2018 5

Blauberg Ventilatoren 174 N. 36th Street Lafayette, IN 47905 tel.: +1 765 780 7139 info@blauberg.us www.blaubergventilatoren.de Technical changes reserved. Illustrations and texts are non-binding. 11/2017