Inside. Wall Gasket. Fixture Wall. Certifications. Year Warranty. -40 C C Operating

Similar documents
MaxLite LED MICRO-T PANEL

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

MaxLite LED High Bay Fixtures

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

MaxLite LED Vapor Tight Linear Fixture

MaxLite LED Round Pendant Highbay Series

TrueClean ToteCleaner

Blade Series Heat Exchanger Operation and Installation

DUST FREE CARBON Whole House Air Purifier

LED RETROFIT CONVERSION KITS

BACKUP BATTERY INSTALLATION INSTRUCTIONS

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Compact Equipment Warranty Policy

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

OPERATION, SERVICE & PARTS MANUAL

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

TrueClean ToteCleaner

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

6502B RF Distribution

MaxLite Polygon Linear LED Light

ion Genesis Pump Controller

INSTRUCTION MANUAL HS-229G

INSTALLATION INSTRUCTIONS TALKBACK MODULE

OPERATION, SERVICE & PARTS MANUAL

Installation Manual. Top of Pole Mount Edition v1.01. For models:

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Remote Relay Module (RRM)

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

Humidity Monitor model 01080

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

DHL-LP-LED Low Profile LED Linear High/Low Bay

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

LOSBAY800. BAY SENSOR Installation Manual. LOSBAY800 Specifications

INTEGRATED LIGHTING CONTROLS

Duct Mount. Installation Instructions

America s Walk-In Tub. Installation & Instructions. Manufactured by. A Division of Spa World Corp NW 35th Avenue ANSI-Z124.1

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Installation Instructions

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Roof Mounting System. Installation Manual. Light Rail (XRL) 2013 Edition v1.3. Solar Mounting Made Simple

WATCHMAN AREA VOLTAGE DETECTOR

Roof Mounting System. Installation Manual. Standard Rail (XRS) 2013 Edition v1.3. Solar Mounting Made Simple

Surge Protective Devices Installation, Operation and Maintenance Manual. LowProfile Series: 080 and 120

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

INSTALLATION MANUAL. PP2 Ozone System (No Filter Cartridge) PP3 Ozone System (With Filter Cartridge) nspdevelopment.com

INSTALLATION MANUAL. PP1 Ozone System Designed for use within pool skimmer

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

V-Line Gen3 V3285. Installation Guide

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Patent Pending invent for New Construction

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

FAQ s- 30mm Stacklights

ALM100 Alarm Module. User s Manual

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Model: 1001T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Dimensions of the Optional Mounting Box (BB-400R/W)

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

Light Construction Equipment Consumer Warranty Policy

Instruction Manual. AcuRite Atlas Outdoor Device model 06059

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

Whynter Portable Ice Maker 33 lb capacity - White

GG-CO-EXP CARBON MONOXIDE SENSOR. Installation and Operation Manual

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Tri-level Control HF Sensor

Instruction Manual. Carmel Apple-Dip Warmer

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

CLS-EXP-DIM. Functional Summary. Specifications

User's Manual H-VC5. Chore-Logic. H-VC5 User manual. Version HPS 11/11/2006 User manual 1.02 ST50737MA 3/07. Page 1

Ultrasonic Reflective Sensor

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

CA 120 Owners Manual of 10

GASGUARD H2S EXP. Hydrogen Sulfide Sensor OPERATING & INSTALLATION MANUAL

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Instruction Manual. AcuRite Atlas. Indoor Display model 06061

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

View the expanded manual: GEN5

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

False Ceiling HF Sensors

FW-RA-LED Remote Multiplex Annunciator Panels

Series: MBC1-TC Mini Benchtop Temperature Controller

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Radio Frequency Do s & Don ts

CD6102 / CD6102 OC / CD6102-2

GASGUARD SO2 Sulfur Dioxide Sensor OPERATING & INSTALLATION MANUAL

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Transcription:

The BRl823-B-D mounts in an outdoor lighting fixture and provides multi-level control based on motion and/or daylight contribution. t controls 0-1 0 VDC LED drivers or dimming ballasts, and is rated for wet and cold locations. All control parameters are adjustable via a wireless configuration tool capable of storing and transmitting sensor profiles. Application The slim, low-profile BRl823-B-D is designed for installation inside the bottom of a light fixture body. When fully assembled and installed in an P65-rated fixture, the PR sensor module parts are P65 outdoor rated. The sensor is ideal for areas such as parking facilities, gas stations, pedestrian pathways and warehouses. A choice of two PR Lens ensures complete coverage for mounting heights up to 40. Features Provides line voltage On/Off switching and 0-10VDC dimming control Works with ballasts or LED drivers High and low modes fully adjustable from 0 to 10V Time delay from 5 to 30 minutes Optional cutoff delay Adjustable ramp up and fade down times CLASS 2 for whole sensor Optional daylighting setpoints feature automatic calibration, or permit manual adjustment. Polycarbonate, flame retardant, UV resistant, impact resistant. UL773A and FCC Operation Typically, the sensor ramps lighting On to the selected High mode level when motion is detected and the ambient light level is below the hold off setpoint. After the sensor stops detecting movement and the time delay elapses, lights fade to the Low mode level. f there is no motion during the subsequent cut off time delay, the lights will turn Off. For dusk to dawn control, the integral photocell can switch the lights On and Off based on the ambient light level so that lighting remains on overnight even without motion detection. Mounting ted Se e BR1823-B-D Tightening Tightening Nut Nut Lens Lens Assembly Assembly LED LED Controller Wireless Handheld Configuration Tool nitial setup and subsequent sensor adjustments are made using a handheld configuration tool (RC-100). This tool enables adjustment of parameter, is also used to initiate automatic calibration of the BRl823- B-D ambient light level setpoint. The setpoint is used to hold the controlled lighting off or at low level when there is sufficient daylight. The wireless tool stores up to five sensor parameter profiles to speed configuration of multiple sensors. BR1823-B-D Fixture ubber nside Rubber Wall Gasket Fixture Wall Gasket 1 Outside Outside Fixture Wall Fixture Wall Tightening Nut Nut 0.2 (minimum) Tightening Nut Lens Assembly Rubber Gasket Fixture Wall Specifications Power Supply Maximum Load -40 C-70 C Dim Control Output Detection Radius/ Angle 120-277VAC 50/60Hz Resistive/Tungsten - 600W@120V Ballast Electronic (LED) -800/1200VA@120/277V 0-10V, max. 25mA sinking current 30ft@40ft height/360 Certifications Year Warranty Qm a P65 Mounting Height Max 24ft. @LW1 Max 40ft. @LS2 Remote Range 50ft. (15m) indoor, no backlight Humidity Temperature Max. 95% RH -40 C - +70 C -40 C -+ 70 C Operating

Sensor g 3.5 [89. 75] 3.5 ( 81.16 ) 3.2.2 2.4 1.6 [41]. 6 1.4 Dimensions.5 1.7.7 1.3 Lens Qm a 2.32 \\ ( J;_t, p, i m.75 2.32.75 19.1nvn \\( J/6 '('" Rubber Gasket Lens Nut Rubber Gasket L N Threaded Collar Threaded Collar

Parameter Setting Parameter Setting By Dip Switch Consider the picture: 1, 2 set sensitivity; 3, 4 set hold time; 5, 6 set the lux; 7, 8 stand-by light level ; 9,10 set stand-by time ; Detection Range Setting (sensitivity) Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground after mounting the sensor light at a height of 8-40ft, pull switch to the position as" + ", pull switch to the position as"+", switch location and detection range of the [n SENSTVTY 2 20% 50% 75% SENSTVTY:1, 2 Hold Time Setting 100% The light can be set to stay for any period of time between approx.10sec and a maximum of 60min. Any movement detected before this time elapse will re-start the timer. t is recommended to select the shortest time for adjusting the detection zone and for performing the walk test. Pull switch to the position as "t", pull switch to the position as"+", switch location and detection range of the TME 3 4 + ll TME:3, 4 10S 10Min 30Min 60Min Light-control Setting The chosen light response threshold can be infinitely from approx. 10-501ux, pull switch to the position as "+", switch to the position as"+", switch location and light-control of the + 8 8 6 LUX:5, 6 Stand-by Light Level Setting LGHT 5 6 (light sensor disable) 10Lux 30Lux 50Lux Switch to the on is "t ", switch to the off is"+"; he corresponding file of switch location and detection distance as follow: + 8 8 0% STAND-BY LEVEL 7 8 + 10% 7 8 30% STAND-BY LEVEL:7, 8 50% Stand-by Time Setting File of switch location and detection distance as follow: file of switch location and detection distance as follow: STAND-BY TME B 9 10 oo 1Min 30Min STAND-BY TME: 9, 10 60Min pull

Wiring wiring with dimming ballast or LED driver. Dimming Driver LOAD LOAD(Red) (Red) NEUTRAL NEUTRAL(White) NEUTRAL(White) LNE(Black) Dimming Driver Dimming Driver GRAY(-) (-) VOLET(+) VOLET (+) Coverage LW1 LW1 Coverage Side View Coverage Side View 30' 20' 10' 0' 10' 20' Coverage Coverage Top Top View l 60' 24' 11' 7' 3'0' 3' 7' 11' LW1: 360 Coverage Coverage 2 4' 20' 10' 0' 10' 20' 30' LS2 Coverage Coverage Top Top View View LS2 Coverage Side Side View View,l 40' 30' 20' 12' 6' 0' 6' 12' 20' 30' LS2: 360 Coverage Coverage O' 15' 0' 15' 30'

10 Year Warranty ATG Electronics ndustry Leading 10 Year Limited Warranty For North American LED Lighting Fixtures ATG Electronics warrants to the original purchaser of ATG Electronics Domestic LED products listed above that were manufactured for which the ATG Electronics Spec Sheet located on our website contains the words 10 year limited warranty that, subject to the below terms and conditions of this warranty, when such LED products are properly installed they will comply with ATG Electronics published product specifications for such products and will be free from material defects in material and workmanship for a period of ten (10) years from the date of sale by ATG Electronics, or, if lesser, 50,000 hours of operation (at an average of 13.6 hours per day operation). The LED arrays in the Product(s) will be considered defective in material or workmanship only if a total of 15% or more of the individual light emitting diodes in the Product(s) fail to illuminate. The above express limited warranty is extended by ATG Electronics only to the original or first end-user purchaser and only for the original installed location. This warranty only applies to products purchased after June 1, 2017. This warranty is non-transferrable, whether by assignment or operation of law. The original purchaser must provide warranty claims to ATG Electronics within the warranty period promptly upon discovery and in accordance with ATG Electronics Return and Repair Procedures as outlined within this document. Should any defects be found by ATG Electronics upon its inspection of the properly returned product, ATG Electronics sole responsibility and liability under this warranty will be, at its option, to either repair or replace the defective part or parts or else make available a new replacement unit that will provide equal or better performance. All decisions regarding the existence or non-existence of defects or otherwise affecting the warranty shall be made by ATG ELECTRCS and shall be final and binding on all parties. Where a defective LED product is replaced under this warranty, the balance of the original warranty period shall remain effective. Conditions and Exclusions This warranty is conditioned upon proper installation, use and maintenance. This warranty will automatically become null and void and shall not be applicable to any LED fixture which (i) has not been timely paid for, (ii) is not installed and operated in accordance with the current edition of The National Electric Code (NEC), the Standards for Safety of Underwriters Laboratory, nc. (UL) or with ATG Electronics instructions and guidelines, (iii) has been moved from its original installation, (iv) has been installed within an area that has exposure to sulfur or any area with high acidic compounds in use, (v) has been operated in an ambient temperature or humidity that is higher than 35 degrees Celsius, (vi) has been subjected to a lightning strike, power surge or overvoltage condition, (vii) has its LED Board subjected to static electricity due to failure to discharge same prior to connecting or disconnecting the lead from the LED board, (viii) was not installed and/or operated in accordance with ATG Electronics instructions and guidelines, (ix) has been mishandled, misused, abused, tampered with, modified or altered by anyone other than ATG ELECTRCS, (x) has been subjected to abnormal stresses and operating conditions, or (xi) has been operated without overvoltage and lightning protection devices in place. Limitations Disclaimers & Limitations of Liability The foregoing warranty is exclusive of all other statutory, written or oral warranties and no other warranties of any kind, statutory, by operation of law or course of performance, or otherwise, are given, herein expressed or otherwise received. EXCEPT AS EXPRESSLY PROVDED ABOVE, ATG ELECTRCS DSCLAMS ALL REPRESENTATS, WARRANTES AND CDTS OF ANY KND, EXPRESS OR MPLED, REGARDNG THE LED PRODUCTS AND TS SERVCES, NCLUDNG, WTHOUT LMTAT, THE MPLED WARRANTES OF MERCHANTABLTY AND FTNESS FOR A PARTCULAR USE OR PURPOSE. LMTAT OF LABLTY. Other than the obligation to repair or replace as provided above, ATG Electronics shall have no liability for any losses, expenses or damages as a result of the installation, use, inability to use, removal or replacement of any LED product. ATG Electronics will not under any circumstances whether as a result of breach of contract, breach of warranty, tort, strict liability or otherwise be liable for consequential, incidental, special or exemplary damages including but not limited to, loss of profits or revenues, loss of any other goods or associated equipment or damage to any associated equipment, cost of capital, cost of substitute products, facilities or services, down time cost or claims of claimant s customers. ATG Electronics liability on any claim of any kind for any loss or damages arising out of, resulting from or concerning any LED product, any aspect of this warranty or for any products or services furnished hereunder shall not exceed the price of the fixture which gives rise to the claim. Return and Repair Procedures All warranty requests and or questions are to be directed to ATG Electronics Customer Service Department (CSD) at 888-618-7298. f deemed necessary, the CSD will issue a Returned Merchandise Authorization (RMA) number which must be included on both the packing slip of the component or fixture being returned and on the outside of the box. You must include your name and contact information, including your email address, on the packing slip so that we can contact you easily. Each component or fixture must be packaged very carefully and properly so as to prevent damages in shipment and must be shipped freight prepaid. Please obtain a proof of delivery to ensure that the material is received. Once the component or fixture has been received and tested, an evaluation report will be provided to the end user via email. This report will clarify the following: A) The component / fixture is covered under the warranty policy and will either be repaired or replaced. B) The component / fixture is not covered under the warranty policy and the reason for this determination. f ATG ELECTRCS determines that the component or fixture is covered under the warranty, then the appropriate repairs will be started or a replacement fixture will be manufactured and shipped. Please note that in the event the returned component or fixture is found not to be covered under this warranty, you may be subject to a labor charge for the evaluation process and will be responsible for all return shipping charges and fees. For components and fixtures determined to be covered under this warranty prior to the first anniversary of the Sale Date, the repaired or replacement component or fixture will be returned to you at no charge. You will be responsible for all other shipping charges. No Labor Reimbursement All components and fixtures determined to be covered by this warranty as provided above, will be repaired or replaced at no charge to the customer, however, except as expressly provided above with respect to recessed and linear fixtures during the first year, the customer must hire and pay for an electrician to remove and reinstall such components and fixtures. No labor costs will be covered for the removal or reinstallation of any components or fixtures. The warranty does not cover modifications, repairs or replacements, or the related labor or materials costs, that may be necessary to facilities or third party products in connection with the removal, repair, or replacement of any LED product under this warranty.