unistor High performance unvented stainless steel cylinder range

Similar documents
unistor High performance unvented stainless steel cylinder range

ecotec plus New high efficiency condensing combination and system boiler ranges

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

thermocompact High performance system boiler range

ecotec range High efficiency condensing boiler range

ecotec plus 937 Power store high efficiency combination boiler

Domestic boiler range. Why Vaillant? because they are the choice of a professional. ecotec exclusive ecotec plus ecotec pro

Because our systems are the choice of a professional.

ecomax pro High efficiency condensing boiler range for traditional systems

Solar. domestic hot water systems. Using the sun s energy to provide hot water

unistor Instructions for Installation and Use Unvented hot water storage cylinder

aquaplus High performance combination boiler with integrated power store

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Why Vaillant? Because with the new ecotec Vaillant Improves Performance.

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Installation Instructions. Unvented hot water storage cylinders for use with Vaillant boilers

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

turbomax plus High performance combination boiler range

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Multipoint Technical Data

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Stainless Steel Unvented Cylinders

UNVENTED STAINLESS STEEL CYLINDERS

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

Why Vaillant? aurotherm Solar Thermal. The TECHNICAL Brochure. Because we provide the best solar systems under the sun

Instructions for Use Installation and Servicing

Exceeding the Standard

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Exceeding the Standard

INTERCYL. INTERNAL EXPANSION EXCELLENCE

UK arotherm Schematics and installation guide

WRAS TEST & ACCEPTANCE CRITERIA Issue No: 1 Date of issue: October Sheet 1 of 7

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

Broag Pressurisation equipment

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

SOLAR HEATING SYSTEMS

The new ecotec exclusive from Vaillant with Green iq technology

The iqe Boiler Range. Combination and System T Boilers.

Where gas is not an option,

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

T. +44 (0) E.

Commercial Hot Water Solutions Ltd.

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

THERMAL STORE MAINS PRESSURE SYSTEM

For latest prices and delivery to your door visit MyTub Ltd

Air to air heat pump range. Why Vaillant? because there is something in the air.

Alpha FlowSmart 25 and 50

Solar thermal domestic hot water system

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

Instructions for use Installation and Servicing. Unvented Hot Water Cylinders/ Hydracyl

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

EnergyMasterHP. user guide. Cylinder for use with NIBE heat pump systems. v12 Nu-Heat 2017 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

the electric heating company ELECTRIC BOILER HANDBOOK

flexotherm heat pump Why Vaillant? Because our heat pumps offer greater flexibility Comfort for your home Heating Hot water Renewables

THERMAL STORE MAINS PRESSURE SYSTEM

PRODUCT GUIDE 2018/19 ACV HEATING AND HOT WATER SPECIALISTS

maximise the sun s energy with warmflow solar Warmflow Solar

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Ground source heat pump range. Why Vaillant? because we can unearth the energy.

EFFICIENCY THERMAL STORAGE SYSTEMS

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Unvented Hot Water Systems for the Professionals

Kills bills. How Vaillant technologies reduce home heating bills

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Grant Wave range. High efficiency direct and indirect hot water storage solutions

Efficiency Maximiser for Solid Fuel Central Heating

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

JASPI GTV & Oval thermal storage

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

CUBEflow Thermal Store Tank

Alpha CombiMax 350 and 600

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

FlowSmart. The high efficiency, high performance space saving heating system.

HOT WATER SYSTEMS.

Installation and Servicing Instructions. Alpha FlowSmart

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

Instructions for use Installation and Servicing. Solar Hot Water Cylinders/ Flurocyl

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

aurostor Installation and maintenance instructions Installation and maintenance instructions For the competent person GB, IE VIH S GB...

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

Transcription:

unistor High performance unvented stainless steel cylinder range

High recovery, high performance Vaillant s latest range of unistor stainless steel unvented cylinders gives you the option of a broad range of capacities from 125 litres up to 310 litres. Whichever cylinder you choose, you can be sure of the quality and performance that you expect from Vaillant. In addition a high recovery heating coil and superb reheat times being best in class make unistor the only choice in unvented cylinders. And what s more, the unistor range is fully compatible both with Vaillant system boilers (high efficiency ecotec and ecomax boilers and standard efficiency thermocompact boilers) as well as any other manufacturers boilers so whatever the system you can always add an extra touch of Vaillant performance. For the ultimate level of performance and control, unistor cylinders can also be integrated in to the Vaillant total system solution ecotec high efficiency boiler, unistor cylinder, controls and VR 65 control centre all from the industry s leading manufacturer. unistor s high grade stainless steel construction with laser welded seams carries a full 25 year antiperforation guarantee on the cylinder shell for complete piece of mind. Also included with the product is an expansion vessel (up to 25 litres), all cold and hot water controls and a 2-port valve, as well as the expansion vessel mounting kit. All cylinders are equipped with a 3kW back up immersion heater with the option of a second immersion on the 260 litre and 310 litre models. unistor fits perfectly into the tightest of spaces, with all cylinders sharing a common width of 554mm. Installation is simplified by both low lift weights across the range and simple front access connections. Installation is further enhanced by easy access to all of the electrical controls and connections located behind a simply removable cover panel.

unistor unvented cylinders Typical applications Single bathroom property unistor 125 Single bathroom property with an en-suite shower room unistor 125 / 155 Two bathroom property unistor 155 / 180 Two bathroom property with an en-suite shower room unistor 180 / 210 Larger properties unistor 260 / 310

When using unistor cylinders as part of the Vaillant Total System Solution, the VR 65 control centre also includes an optional NTC cylinder sensor (VR 10) giving complete control over the hot water performance. Which offers benefits over the traditional installation 2 port valve Expansion vessel - All supplied from one manufacturer with one service supplier - Harmonised controls keeping the boiler in condensing mode for as long as possible - Ability to control the hot water temperature from the boiler or controls when using the VR 10

Total System Solution Which components form the total system solution? - ecotec plus system boilers - unistor stainless steel cylinder (supplied with 230V DHW valve) - ebus controls e.g. VRT 360, VRC 400 - VR 65 Control Centre - unistor cylinder NTC (VR 10) Note: 230V zone valves (for CH) are widely available and must be supplied separately. y Vaillant ecotec system boilers and unistor unvented stainless steel cylinders can now be integrated into one complete system together with the new Vaillant ebus controls. This total system concept brings some unique features and benefits to the installer and the home-owner. Benefits - All components supplied from one manufacturer for peace of mind - All components are compatible - DHW temperature can be set at the boiler or at the control - Cylinder re-charge with AquaCondens system which re-charges cylinder at the most economical temperature to maintain efficiency - Easy to integrate with underfloor heating systems - Simple wiring - Easy to upgrade existing systems VR 65 control centre The VR 65 control centre is the heart of the total system solution. It has been designed to allow Vaillant low voltage ebus controls to be integrated within traditional 230V S-plan or Y-plan type installations to provide a total system solution. The VR 65 control centre provides the following connection points:- - 1 x 3-port zone valve or 2 x 2-port zone valves - 230V cylinder thermostat - NTC for installation in unistor only (instead of 230V cylinder stat) - 230V connection - ebus connection

Technical Specification unistor 125 unistor 155 unistor 180 unistor 210 unistor 260 unistor 310 Size litres 125 155 180 210 260 310 Maximum water supply pressure bar 10 Expansion vessel charge pressure bar 4 Operating pressure bar 3.5 Pressure reducing valve bar 3.5 Expansion relief valve bar 6.0 T/P valve C/bar 95 / 7.0 Maximum primary circuit pressure bar 2.5 Weight (cylinder) kg 28 30 33 39 44 49 Weight (full) kg 145 175 205 245 310 340 Height mm 969 1179 1339 1499 1789 2109 Cylinder connections Cold mains inlet DHW outlet Balanced pressure cold water outlet Secondary return G 3 / 4 Primary flow Primary return (on 2 port valve) Electrical connections 3 kw Immersion heater 230V, 50 Hz 2 port valve 230V, 50 Hz Cylinder thermostat 230V, 50 Hz Coil Specifications Heat up times 16.2 27 Heat loss kw/24h 1.4 1.7 1.8 1.9 2.1 2.4 Note: Heat up time based on a primary flow rate of 15 l/min at 82 C. Temperature rise is from 15 C to 65 C for 70% of the cylinder volume. Vaillant Ltd. Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Telephone 01634 292300 Fax 01634 290166 www.vaillant.co.uk info@vaillant.co.uk 03.05 unistor brochure. 2376138