IF-L/RF Protection Switch

Similar documents
AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Instruction Manual Model L2 RF Switch

Instruction Manual Model Backup Switch, 1 for 8

STATUS ALARM HISTORY ALARM RESET

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

21-light Remote Annunciator. Owner s Manual

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

ACCURATE ELECTRONICS INC

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Model 4001 Series Single Channel Controller

6502B RF Distribution

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Pump-Down Controller MODEL 4052

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

PTE0705 Electric Fence Monitor

GAS MONITOR Model Model

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SIMATRIX NEO Modular Video Matrix

TC Channel Serial-over-T1/E1 Multiplexer. User Manual MNL

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Pump-Up Controller MODEL 4062

20 Light Remote Annunciator

Ethernet to Serial Bridge Owners Manual Circuit Board: AB Converter: Digi Connect ME

Alarm Tone Generator Model AG17

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

ME 3011C / Alarm Indication / Quick Reference Guide

AIS750 Series Alarm Annunciator

TC CH. 600Ω Analog & Dry Contact over T1/E1 Multiplexer. User Manual MNL

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

HRX Technical Manual. Version 1.2

Smart Series TAS-05-11, TAS-05-12

Beacon 410A Gas Monitor Operator s Manual

Installation Instructions for the

Lopolight navigation light control panel External monitoring and control. Protocol NMEA 0183 interface IEC:2010(E)

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

DETECTION SYSTEMS. GCM Auto Alarm. Instruction Manual. GA0203P01 Rev. D

WM3000 WIRELESS MODULES

Galaxy Pulsar Plus Digital Battery Plant Controller

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Installation Manual COPYRIGHT NOTICE

Model AD C AD RS-422 Distributor

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

Mark 25 Ultrapure Water Conductivity Analyzer

Ethernet General Purpose

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

FW-RA-LED Remote Multiplex Annunciator Panels

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Model A1700 Series Annunciator

4 & 8-POINT ANNUNCIATORS Instruction Manual

USER MANUAL FOR OPERATING SYSTEM

Temperature Controllers

ESP TECHNOLOGIES LIMITED

Protocol Station Remote Alarm

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

RTD TEMPERATURE SENSING SYSTEM

Beacon 800 Gas Monitor Operator s Manual

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Panel Mounted Heat Exchangers by Dantherm, Inc.

Sierra Series 900 Single & Dual Channel System. Instruction Manual

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

OPERATING MANUAL. EchoThermJ DIGITAL HOT PLATE MODEL HP30 AND HP30A. DOCUMENT NUMBER HP30-03 Revised 10 December 2011

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Installation Instructions

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

E340 BOILER CONTROL INSTALLATION MANUAL

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

VPS3 Installation Manual

Global Water Instrumentation, Inc.

LUMA-NET 804CP / 808CP REMOTE CONTROL PANEL

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

MODEL EPC-D-F-ATS INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

7EF/7HF/7EC/7ES Temperature Controllers

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Fratech Multipath-IP

Single Station Remote Alarm

Transcription:

Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC. Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. Printed in USA. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alphabet, Georgia 30005 (770) 886-8005 FA (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com

INSTRUCTI MANUAL MODEL 1582-1152 IF-L/RF Protection Switch TABLE OF CTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 4 1.3 Monitor and Control Interface 6 1.4 M&C Commands 7 2.0 Installation 11 2.1 Mechanical 11 2.2 Input and Output Signals 12 2.3 Controls and Indicators 13 2.4 Operation 14 3.0 Environmental Use Information 17 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alphabet, Georgia 30005 (770) 886-8005 FA (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com 1582-1152 Manual, Rev. 0 Page 2 08/14/14

MODEL 1582-1152 IF-L/RF Protection Switch 1.0 General 1.1 Equipment Description The 1582-1152 1:1 Switch, IF-L/RF provides Auto, Manual or Remote (M&C) relay switching between CH1 and CH2, IF-L and RF signals. The M&C provides monitoring of all parameters and Channel Selection (when in Auto mode only). Alarm conditions on CH1 and CH2 are either a contact closure to ground or an open (selectable by a rear panel DIP switch). Auto has three modes: Auto - CH1 PRIME ; The CH1 preferred mode - switches from CH1 to CH2 only if CH1 alarms and CH2 is good. The unit switches back to CH1 when CH1 is no longer in alarm or both CH1 and CH2 are alarmed. Auto - LATCH2; Latch to CH2 mode - switches from CH1 to CH2 if CH1 alarms and CH2 is good and stays in CH2 regardless of CH1 or CH2 alarm conditions until reset to CH1 by the front panel Switch Reset switch or M&C command. Auto - MIN SW; Minimum Auto switching mode - switching occurs if the active channel (set by the front panel Manual Select switch or M&C command) alarms and the other channel is clear. It switches back if this channel then alarms and the other is clear.when power is lost, CH1 is selected; with option -L, the last latched state is selected. Front panel LEDs indicate CH1 and CH2 alarms, Remote or Manual mode, and redundant power supplies on. Rear panel DIP switches set alarm polarity (NO or NC for alarm), M&C interface, and Auto modes (CH1 PRIME, LATCH2, or MIN SW). The front panel switch selects the signal path in the Manual mode or selects AUTO switching. The RS232 or RS422/485 M&C (Ethernet optional) monitors switch positions, LED and alarm status, and selects the RF switch position (when in Auto mode only). A contact closure to ground indicates an internal fault condition or loss of power. Connectors are SMA for RF, BNC for IF-L signals and DB9 for M&C and alarm input and output contact closures. The 1RU chassis has separately fused, redundant power supplies with 100-240 ±10% VAC input connectors. CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC. FRT PANEL ACE ACE GND CFIGURATI 1 8 (Ether net Optional) 5 4 3 2 1 9 8 7 6 UNIT 1 M&C 5 4 3 2 1 9 8 7 6 J16A 5 4 3 2 1 9 8 7 6 J24 A1 J25 A J26 A2 S1 J14 REAR PANEL M&C J18 UNIT 2 M&C J16B J4 J5 J6 FIGURE 1.1 Model 1582-1152 IF-L/RF. Front and Rear Panels CH 1 IF/L-BAND IN CH 2 IF/L-BAND IN CH 1 RF. IN CH 2 RF. IN ED IF/L-BAND OUT ED RF. OUT ALARM CHI ALARM CHI CTROLLER REAR PANEL DIP ES M&C SUMMARY ALARM CTACT CLOSURE 1582-1152 BLOCK DIAGRAM FIGURE 1.2 Model 1582-1152 IF-L/RF Switch Block Diagrams 1582-1152 Manual, Rev. 0 Page 3 08/14/14

1.2 Technical Characteristics TABLE 1.0 1582-1152 IF-L/RF. Specifications* IF/L-Band Switch Characteristics Impedance / Connectors Return Loss, db Frequency Response Isolation, minimum Switch Time Insertion Loss, maximum Type, Configuration RF Switch Characteristics Impedance/Connectors Return Loss, db Frequency Response Isolation, db Switch Time Insertion Loss, db Type Configuration Alarm and Control, M&C Alarm Output Signal M&C Interface / Baud Rate Connectors, Indicators Auto/Manual Switch Reset, History Reset Power, Remote, Manual, Alarm Connectors, Other RF, IF-L Connectors Ext. Alarms In, M&C Connector Size Power 75Ω / BNC 12 to 1.5 GHz; 10 to 2.5 GHz ±0.5 db, any 40 MHz BW, DC to 2.5 GHz 55 db to 1.5 GHz; 45 db to 2.5 GHz 10 Milliseconds 1.5 db DC to 1.5 GHz; 2.5 db to 2.5 GHz Relay, SPDT 50Ω / SMA > 18 to 4 GHz; > 15 to 8 GHz; > 12 to 15 GHz ±0.5 db, 40 MHz BW; ±1 db, 1 GHz BW > 70 to 4 GHz; > 60 to 8 GHz; > 50 to 15 GHz 10 Milliseconds 1 to 4 GHz; 1.5 to 8 GHz; 2.0 to 15 GHz Relay, SPDT, no termination Form C relay: 30VDC, 0.5A maximum RS232C or RS422/485, Selectable / 9600 (Ethernet Optional) Front Panel Switch Front Panel Switches or M&C Green, Yellow, Red, Red LED - Form C contact closure, M&C 50Ω SMA (female), 75Ω BNC (female) DB9 (female) 1 RU, 19 inch Standard Chassis, 1.75 high x 12.0 deep Redundant 100-240 ±10% VAC, 47-63 Hz., 20 Watts maximum Power Supplies. *10 C to 40 C; Specifications subject to change without notice. Cross Technologies, Inc. (Technical Characteristics continued on page 5...) 1582-1152 Manual, Rev. 0 Page 4 08/14/14

(Technical Characteristics continued from page 4...) Available Options L - Remote M&C Interface W- 8 W-18 W-28 W-31 Connectors/Impedance S - Latched Relay Switching (relay position preserved on power loss) Ethernet Ethernet with SNMP (and MIB) Interface Ethernet with Direct TCP/IP Interface -0 to +50 degrees C Operation 50Ω SMA (RF), 50Ω BNC (IF-L) SF - 50Ω SMA (RF), 75Ω F (IF-L) * 10 C to 40 C; Specifications subject to change without notice Cross Technologies, Inc. 1582-1152 Manual, Rev. 0 Page 5 08/14/14

1.3 Monitor and Control Interface A) Remote Serial Interface Protocol: RS232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit. (RS232C, RS-422, or RS-485) M&C Cable Diagram - Cross Technologies Frequency Converters Female DB-9 PC Com Port 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 Connector: Rear panel, DB-9 Female: J15 Pinouts (RS-232C/422/485) Pin Function 1 Rx- 2 Rx+ (RS-232C) 3 Tx+ (RS-232C) 4 Tx- 5 GND 6 Alarm Relay: Common 7 Alarm Relay: Normally Open 8 Not Used 9 Alarm Relay: Normally Closed 1582-1152 Manual, Rev. 0 Page 6 08/14/14

1.4 M&C Commands The following tables summarize the commands and status queries applicable to the 1582-1152 Protection Switch. * PLEASE NOTE: The two character {aa} prefix, shown in the table below, is present LY when RS485 is selected. Table 2.0 Model 1582-1152 - M&C Remote Commands Table 2.0: Model 1582-1152 M&C Remote Commands Command Function Syntax Command Description Set RF Switch Position {aacrx} R = Command Code x = desired switch position, 1 or 2. Once the switch position is selected remotely, the uni is in "Remote Mode" and the front panel remote indicator will light. The unit will remain in Remote Mode until one of the following occurs: 1. A Switch Reset command ( {CB} ) is issued. 2. The front panel Switch Reset button is pressed. If the switch is already in manual mode (i.e, the front panel toggle switch is in the CH1 or CH2 position) then the unit will ignore this command. example: {CR2} Will (remotely) set the switch to CH2. The unit will ignore this command if the unit is in manual mode. The unit will reply with the '<' character if the command is not processed because the unit is in Manual Mode. The unit will reply with the '>' character if the command is successfully processed. Switch Reset {aacb} B = Command Mode This command has the same effect as pressing the front panel Switch Reset button. example: {CB} Will return a unit to Auto mode if it is in Remote mode. Also, this command will reset the switch position if it is currently latched to CH2 mode (and if CH1 is not alarmed). The unit will reply with the ʻ>ʼ character if the command is successfully processed. Alarm History Reset {aachx} H = command mode x = 1 to reset the CH1 Alarm History State x = 2 to reset the CH2 Alarm History State example: {CH2} Will clear the CH2 Alarm History Status and LED Table 2.0 M&C Remote Commands Continued on page 8... 1582-1152 Manual, Rev. 0 Page 7 08/14/14

1.4 M&C Commands (continued) Table 2.0 M&C Remote Commands Continued from page 7... Table 2.0: Model 1582-1152 M&C Remote Commands Continued Command Function Set RS485 Address Syntax {aacxx} Command Description x = command code xx = unit address, range = 00 to 31 example: {C12} Will set the unitʼs RS485 address to 12 1582-1152 Manual, Rev. 0 Page 8 08/14/14

1.5 M&C Queries Table 2.1 Model 1582-1152 - M&C Status Request/Inquiries Table 2.1: Model 1582-1152 M&C Status Request/Inquires Command Function Syntax Command Description Get Switch State {aasz} Returns; {aaszbcdefgh} Z = Command Code b = Switch Position: 1 or 2 c = Switch Mode: M if in Manual Mode, R if in Remote Mode, and A if in Auto Mode. The unit will append the ʻ>ʼ character if the command is successfully processed. Get Channel 1 Alarm Status {aas1} Returns: {aas1bc} 1 = Command Code b = CH1 alarm status: 0 if alarm is off, 1 is alarm is on c = CH1 alarm history status: 0 if no alarm history. i if an alarm occurred The unit will append the ʻ>ʼ character if the command is successfully processed. Get Channel 2 Alarm Status {aas2} Returns: {aas2bc} 2 = Command Code b = CH2 alarm status: 0 if alarm is off, 1 is alarm is on c = CH2 alarm history status: 0 if no alarm history, i if an alarm occurred The unit will append the ʻ>ʼ character if the command is successfully processed. Get Auto Switching Mode {aasa} Returns: {aasax} A = Command Code x = 1 fo CH1 Prime Mode, x = 2 for Latch to CH2 Mode, x = 3 for Minimum Auto Switching Mode. The unit will append the ʻ>ʼ character if the command is successfully processed. (M&C Status Request/Inquiries Continued on page 10...) 1582-1152 Manual, Rev. 0 Page 9 08/14/14

1.5 M&C Queries (continued) Table 2.1 Model 1582-1152 - M&C Status Request/Inquiries (Continued from page 9) Table 2.1: Model 1582-1152 M&C Status Request/Inquires Command Function Syntax Command Description Get RS485 Address {aas} Returns; {aasxx} = Command Code xx = unitʼs RS485 address The unit will append the ʻ>ʼ character if the command is successfully processed. Get Ch1 Alarm Polarity {aask} Returns; {aaskx} K = Command Code x = Alarm input polarity, 0 if logic low = alarm, 1 if logic high = alarm The unit will append the ʻ>ʼ character if the command is successfully processed. Get Ch2 Alarm Polarity {aasl} Returns; {aaslx} L = Command Code x = Alarm input polarity, 0 if logic low = alarm, 1 if logic high = alarm The unit will append the ʻ>ʼ character if the command is successfully processed. 1582-1152 Manual, Rev. 0 Page 10 08/14/14

2.0 Installation 2.1 Mechanical The 1582-1152 consists of one RF./Controller PCB and one IF piggyback PCB housed in a 1 RU (1 3 4 inch high) by 12 inch deep chassis. Redundant switching power supplies provide power for the assembly. The 1582-1152 can be secured to a rack using the 4 holes on the front panel. FIGURE 2.1 1582-1152 RF Switch Assembly 1582-1152 Manual, Rev. 0 Page 11 08/14/14

2.2 Input and Output Signals Figure 2.2 shows the input and output connectors on the rear panel. AC1 - POWER IN 1 AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. AC2 - POWER IN 2 AC input for switching power supply. 100-240 ±10% VAC, 47-60 Hz. CFIGURATI Selects CH1 and CH2 alarm polarities and Auto Switch mode. See Table 3.0 AC1 AC2 GND CFIGURATI 1 8 S1 UNIT1 and UNIT2 M&C (J16A, J16B) Alarm inputs for CH1 & CH2. RF SIGNALS (J24, J25 & J26) IN/OUT is the input to or the output from the converter. SMA (female) 50Ω. UNIT 1 M&C 5 4 3 2 1 9 8 7 6 J24 J25 J26 J16A A1 A A2 (Ethernet Optional) 5 4 3 2 1 9 8 7 6 5 4 3 2 1 9 8 7 6 J14 M&C J15 UNIT 2 M&C J16B J4 J5 J6 M&C (J15) Remote operation via the RS232 or RS422 M&C. DB9 (female) connector. See table 2.1 IF SIGNALS (J4, J5, J6) IN/OUT is the input to or the output from the converter. BNC (female) 75Ω. FIGURE 2.2 1582-1152 IF-L/RF Switch Rear Panel Inputs/Outputs 1582-1152 Manual, Rev. 0 Page 12 08/14/14

2.3 Controls and Indicators Figure 2.3 shows the front panel controls and indicators. CH1 LEDs LEDs indicate alarm state, alarm history state and online status for Unit 1. CH2 LEDs LEDs indicate alarm state, alarm history state and online status for Unit 2. MODE LEDs LEDs indicate Manual, Remote or Auto switching. INDICATOR LEDs LEDs indicate switch position and alarm status. CH1 HISTORY AUTO CH2 HISTORY MANUAL ALARM MODEL 1582 CROSS TECHNOLOGIES INC. HISTORY RESET ALARM LINE MANUAL SELECT ALARM LINE RESET REMOTE AUTO PS1 PS2 HISTORY RESET Push-button resets ALARM HISTORY LEDs only. MANUAL SELECT 3-position switch manually selects CH1 or CH2 or puts the unit in. AUTO mode (Switch position determined by Alarm and Remote closures). RESET Push-button resets switch to CH1 if it is good and switch is in LATCH mode. Also resets REMOTE SELECTI to normal AUTO operation. FIGURE 2.3 1582-1152 Front Panel Controls and Indicators 1582-1152 Manual, Rev. 0 Page 13 08/14/14

2.4 Operation 1. Set the on board controls as desired (Tables 2.0, 2.1, Figure 2.3). 2. Install the 1582-1152 in the equipment rack. 3. Connect RF to the SMA connectors (J24, J25, J26). 4. Connect to signals on the MITORS AND CTROLS connectors, J16A & J16B, as desired (see Figure 2.2, Table 2.1). 5. Connect power via two power cords to AC1 and AC2. 6. Manually switch between channels 1 and 2 and be sure switching occurs. 7. Switch to AUTO. Alarm channel 1 and note that automatic switching occurs. Remove alarm to CHI and note that the output switches as desired. Push RESET if in LATCH mode. Repeat for CHI. 8. Check that CHI and CHI are selected when in AUTO and momentary ground is applied to J7 pins 1 and 2. Momentarily ground Remote Reset pin 4 on J7 if in LATCH mode to return to AUTO operation. FUSE DRAWER SPARE FUSE AC Fuse - 2 amp slow blow (Type T), 5 mm 20 mm ~ INPUT 100-240± 10%VAC 47-63 Hz 2A MA FUSE TYPE T 2A GDC 250 VOLT FOR 100-240 V~ FIGURE 2.4 Fuse and Spare Fuse Locations 1582-1152 Manual, Rev. 0 Page 14 08/14/14

2.5 Auto Switching Description Automatic control determines switch routing by monitoring alarm inputs on two channels (CH1, CH2) and selecting the initial source. Local and remote control of RF sources is also provided. Latching relays allow the switch to remain in its "current" state independent of power loss. The 1582-1152 detects an external alarm condition on CH1 and CH2 by either a contact closure to ground or an open (selectable). Switching logic can be selected as follows: 1) CH1 Prime Mode - Switches from CH1 to CH2 only if CH1 alarms and CH2 is good Switches back to CH1 when it is no longer in alarm or when both CH1 and CH2 are in alarm 2) Latch to CH2 Mode - Switches to CH2 if CH1 alarms and CH2 is good. Latches to CH2. Push Manual Reset or ground Remote Reset pin to return to CH1 if it has no alarm or both CH1 and CH2 are in alarm. 3) Minimum AUTO switching, Initial Channel Select (ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO. AUTO switching occurs only if current channel alarms and the other channel is clear. Switching is accomplished using latching relays so if power is removed from the 1582-1152, CH1 and CH2 RF will continue to go to the output selected prior to power loss and will remain there when power is applied assuming no change in alarm status from when power was lost. The channels can be manually switched by the front panel Manual Select switch. If operating in the ICS mode, the last channel manually selected (CH1 or CH2) will be the initial channel when returning the Manual Select switch to AUTO. External REMOTE contact closures can force selection of CH1 or CH2 when the Manual Select switch is in the AUTO position independent of the alarm conditions of CH1 or CH2. Front panel LEDs indicate alarms, alarm history (prior occurrence of alarms which have now cleared), switch conditions for CH1 and CH2, REMOTE or MANUAL operation and presence of power. RF connectors are 50Ω SMA, female and IF-L connectors are 75Ω BNC, female. Contact closure inputs are via barrier strip. Dual power supplies provide redundant power to the 1582-1152. The chassis is a 1 3/4 rack mount. 1582-1152 Manual, Rev. 0 Page 15 08/14/14

Table 3.0 Model 1582-1152 - Configuration DIP Switch Table 3.0 Model 1582-1152 Configuration DIP Switch Select Serial M&C Interface (SW1, SW2) SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 RS232 RS422 RS485 Ethernet (Optional) Select Auto Switching Mode (Switch A if Dual) (SW3, SW4) SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 CH1 Prime Latch to CH2 Minimum Auto Switching Select Alarm Input Polarity (Switch A if Dual) (SW5) SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Normally Closed (Open = Alarm) (Logic High = Alarm) Normally Open (Closed = Alarm) (Logic Low = Alarm) Select Auto Switching Mode (Switch B if Dual) (SW6, SW7) SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 CH1 Prime Latch to CH2 Minimum Auto Switching Select Alarm Input Polarity (Switch B if Dual) (SW8) SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Normally Closed (Open = Alarm) Normally Open (Closed = Alarm) 1582-1152 Manual, Rev. 0 Page 16 08/14/14

3.0 Environmental Use Information A. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the user manual furnished by the manufacturer of your equipment rack. B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition does not exist due to uneven weight distribution. C. Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack may be greater than room ambient temperature. Therefore, consideration should be given to Tmra. D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Additional space between units may be required. E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on over current protection and supply wiring. Appropriate consideration of equipment name plate rating should be used, when addressing this concern. F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connection to the Branch (use of power strips). G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed. If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED prior to Top Cover screw replacement. FAILURE TO DO this may cause INGRESS and/or EGRESS emission problems. 1582-1152 Manual, Rev. 0 Page 17 08/14/14

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alphabet, Georgia 30005 (770) 886-8005 FA (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com Printed in USA 1582-1152 Manual, Rev. 0 Page 18 08/14/14