American International Journal of Research in Science, Technology, Engineering & Mathematics

Similar documents
American International Journal of Research in Science, Technology, Engineering & Mathematics

International Engineering Research Journal Experimental Investigation of Effect of length on Performance of Axially Grooved Heat Pipe.

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Performance Study of Triple Concentric Pipe Heat Exchanger

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Reducing the Temperature of Machining Tool by using Heat Pipe

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Thermal Performance of a Loop Thermosyphon

Experimentation of Heat Pipe Used In Nano-Fluids

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Adsorption refrigeration system using waste heat

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 12 May 2015 ISSN (online):

Design and Development of Modified Air Cooler and Storage System

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Effect of Parameters on Internal Flow Patterns of a Top Heat Mode Closed-loop Oscillating Heat Pipe with Check Valves (THMCLOHP/CV)

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Effect of Placement of Footing on Stability of Slope

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Experimental Investigation of Two Phase Closed Thermosyphon Using Propylene Glycol As A Working Fluid

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

IJARI. 1. Introduction: Heat Pipes. Volume 3, Issue 3 (2015) ISSN International Journal of Advance Research and Innovation.

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

MICRO HEAT PIPE SYSTEM FOR SPACE AVIONICS

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Basic CFD model of heat pipe

Investigation of Metal and Metal Oxide nanocoating on Fins in HPHE with Silver Water NanoFluid

Heat Dissipation in Control Panel using Heat Pipe

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

ABSTRACT I. INTRODUCTION

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

International Journal of Informative & Futuristic Research ISSN (Online):

Design, Development and Experimental Investigation of Volumetric Air Receiver

Global Journal of Engineering Science and Research Management

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

International Engineering Research Journal

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Compression of Fins pipe and simple Heat pipe Using CFD

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Analysis of Effect of Varying Cross-Section on Thermal Efficiency of a Heat Pipe Heat Exchanger Using CFD

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

EXPERIMENTAL STUDY OF WICK STRUCTURE MATERIAL AND SCREEN MESH ON HEAT PIPE PERFORMANCE

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

DESIGN, DEVELOPMENT AND TESTING OF CROSS FLOW CIRCULAR HEAT PIPE TO COOLING OF OIL

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Transcription:

American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-3580, ISSN (CD-ROM): 2328-3629 AIJRSTEM is a refereed, indexed, peer-reviewed, multidisciplinary and open access journal published by International Association of Scientific Innovation and Research (IASIR), USA (An Association Unifying the Sciences, Engineering, and Applied Research) Experimental Study of Thermal Performance of Conventional Heat Pipe Nishtha Vijra #1, Akhil E. Chaudhari #2, T. P. Singh #3 #1 Assistant Professor, Mechanical Engineering Department, #2 M.Tech. Student, #3 Director and Professor, Symbiosis Institute of Technology (SIT), Symbiosis International University (SIU) Near Lupin Research Park, Gram: Lavale, Taluka: Mulshi, Pune (Maharashtra) - 412 115 INDIA Abstract: A conventional heat pipe is an efficient device that is used to achieve high rate of heat transfer. The purpose of this experimentation was to analyse the effect of variation in heat input and inclination angle on heat transfer of conventional heat pipe. The heat input was varied at various levels and inclination angle was varied for each heat input. The condenser was above the evaporator section in inclined and vertical positions of the heat pipe. For conducting the experiments, conventional heat pipe (HP) was fabricated with SS 304 of total length 900 mm and outer diameter 53 mm with water as a working fluid. The temperature was found to decrease from the evaporator section to condenser section along the length of heat pipe. The typical isothermal characteristic of the heat pipe was observed for all the positions and mainly for inclined and vertical positions of the heat pipe. The time observed to achieve steady state was the least for vertical position. The results conclude that with increase in heat input the thermal resistance decreased. The thermal resistance was found to be the least for the inclined position. Keywords: Conventional heat pipe; Heat Input; Inclination angle; Thermal resistance; Isothermal Characteristic I. Introduction Heat pipe is a passive heat transfer device. It is a hollow sealed pipe containing wick structure all round its inner periphery. Working fluid is present inside heat pipe which is sufficient enough to be absorbed by the wick. The heat pipe consists of evaporator section, adiabatic section and condenser section. Fig. 1 shows the working of heat pipe. Heat is supplied at the evaporator section and thus the working fluid present in the liquid form evaporates. The vapour thus generated moves towards the condenser section due to pressure difference. In the condenser section, heat is rejected in the form of latent heat of condensation and hence the vapour is converted back to liquid form and this liquid is pumped back to the evaporator section due to capillary action of wick structure. The main advantage of heat pipe is that it transfers large amount of heat with low temperature drop. Figure 1 Working of Conventional Heat Pipe Many researchers have performed experimentations on heat pipe to study the thermal characteristics and behaviour of heat pipe in various conditions. Mahjoub and Mahtabroshan [1] simulated the steady, two dimensional, heat transfer and flow equations in both vapour region and porous media using numerical model. The results showed that the thermal resistance of heat pipe increased with increasing wick porosity and decreased with increasing wall thermal conductivity and heat pipe radius. Bock et al. [2] investigated the experimental methods of testing capillary performance of wick structure from micro to nano scale. Ahmad and Rajab [3] carried experimentations on heat pipe to investigate the performance of heat pipe. It was found that the thermal conductivity of heat pipe was higher than a solid piece of stainless steel. Manimaran et al. [4] studied the detailed literature review about various parameters that affected the optimal characteristics of heat pipe. Mozumder et al. [5] carried experimentations on heat pipe for dry condition and with various working fluids for different fill ratio. It was found that 85% fill ratio was optimum for heat pipe performance. Annamalai and AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 183

Ramalingam [6] carried computational fluid dynamics (CFD) analysis of heat pipe to determine the temperature distribution. The CFD results were compared with experimental results and showed good agreement between the two. Ahmed et al. [7] performed numerical analysis of heat pipe to find out the temperature distribution on the wall of heat pipe. Gavtash et al. [8] simulated the effect of nano fluids on the heat pipe using ansys-fluent CFD package to find out temperature distribution on heat pipe wall. Boukhanouf and Haddad [9] investigated the thermal performance of a miniature flat plate heat pipe for applications in electronic cooling. Sukchana and Jaiboonma [10] investigated the thermal performance of heat pipe using R-134a as working fluid by varying the fill ratio and adiabatic length. The literature review showed that most of the work carried earlier on heat pipe was to investigate the thermal performance of heat pipe. Most of the researchers conducted experimentations and determined the surface temperature distribution on heat pipe using copper as the container material. In the present study experimentation was conducted on stainless steel as the container material and water as the working fluid in conventional heat pipe to investigate the effect of variation in inclination angle ( 0, 45 and 90 with respect to horizontal) on thermal performance of heat pipe. Different levels of heat input were applied to study the behaviour of heat pipe and overall effective thermal resistance was calculated. II. Experimental Setup SS304 heat pipe of 900 mm. was fabricated, having 100 mm. of evaporator section, 270 mm. of adiabatic section and 530 mm. of condenser section. The outer diameter of the heat pipe was 53 mm. with 2 mm. thickness. Wick structure of SS302 with single layer, 120 mesh and 0.13 mm. wire diameter was lined inside the heat pipe. 80% fill ratio was considered in present study. Band heater of 230 volt, 500 watt capacity was used to supply heat to the evaporator section. Adiabatic section was insulated with glass wool of 2 inch thickness to minimise heat losses. Number of thermowells were welded along the entire length of heat pipe for insertion of K type thermocouples which were used to measure the vapour temperature. Figure 2 Various Positions of Heat pipe for experimentations Thermocouples were also used on the surface of the heat pipe along the axial length, to measure the surface temperature of heat pipe. Dimmerstat of 230V, 0-4 amp was used to vary the heat input at evaporator section. Thermocouples were connected to 12-channel digital temperature indicator to display the temperatures at various positions. The experiments were conducted for inclination angle 0, 45 and 90 from horizontal as shown in Fig. 2. Heat input was varied from 150 W to 300 W with an interval of 50 W. All the observations of temperature i.e. surface temperature and vapour temperature were recorded. Fig. 3 shows the location of thermocouples along the length of heat pipe. Figure 3 Location of thermocouples along the length of heat pipe AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 184

III. Results and Discussions Vapour temperature and surface temperature profile were obtained along the length of heat pipe as shown in the following figures. Figure 4 Vapour temperature distribution along Figure 5 Vapour temperature distribution along length of heat pipe for 150W for horizontal position length of heat pipe for 200W for horizontal position Figure 6 Vapour temperature distribution along length of heat pipe for 150W for inclined position Figure 7 Vapour temperature distribution along length of heat pipe for 200W for inclined position Figure 8 Vapour temperature distribution along length of heat pipe for 150W for vertical position Figure 9 Vapour temperature distribution along length of heat pipe for 200W for vertical position Fig. 4, Fig. 5, Fig. 6, Fig. 7, Fig. 8 and Fig. 9 show the graphs of vapor temperature Vs axial distance for various positions of heat pipe. These graphs depict the diffrence of temperature between the evaporator section and condenser section and was observed to be maximum for horizontal position of heat pipe, where as this was reduced for inclined and vertical positions. This clearly states the isothermal behaviour (a typical characteristic of heat pipe) for the inclined and vertical position of the heat pipe. This depicts that gravity plays an important role even though the experiments were conducted on heat pipe with wick. Figure 10 Surface temperature distribution along Figure 11 Surface temperature distribution along length of heat pipe for 150W for horizontal position length of heat pipe for 200W for horizontal position AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 185

Figure 12 Surface temperature distribution along length of heat pipe for 150W for inclined position Figure 13 Surface temperature distribution along length of heat pipe for 200W for inclined position Figure 14 Surface temperature distribution along length of heat pipe for 150W for vertical position Figure 15 Surface temperature distribution along length of heat pipe for 200W for vertical position Fig. 10, Fig. 11, Fig. 12, Fig. 13, Fig. 14 and Fig. 15 show the graphs of surface temperature along the axial distance for horizontal, inclined and vertical positions. From these graphs, it could be observed that for heat input of 150 W in horizontal position, during the initial 60 min. of heat supply there was a continous and sharp rate of decrease of temperature throughout the length of heat pipe from evaporator section till the condenser section which may be due to heat supplied to evaporator section being utilized only to heat the water in heat pipe. During the next 60 minutes, before attainment of steady state, the rate of temperature rise decreased sharply indicating the process of evaporation and condensation in the respective sections. Similar trend was observed when experiments were conducted for heat input of 250W and 300W also. Figure 16 Vapour temperature variation along length for various heat input at horizontal position Figure 17 Surface temperature variation along length for various heat input at horizontal position Fig.16 shows the graph of vapour temperature distribution along the length of heat pipe for horizonatal position. From the graph it is visible that for low heat input of 150 W and 200 W the temperature of vapour decreased continously in the axial direction from evaporator section to condenser section. At high heat input where the overall vapour temperature was also high, a slight increase of the vapour temperature was found towards the end of condenser. A very possible reason may be that vapour did not have enough space to expand and being a heat rejection section, superheating of vapour may have taken place although marginally. AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 186

Figure 18 Vapour temperature variation along length for various heat input at inclined position. Figure 19 Surface temperature variation along length for various heat input at inclined position Fig.18 and Fig. 20 show the graphs of vapour temperature along axial distance for inclined and vertical positions of the heat pipe. Decrease in temperature distribution from evaporator section to condenser section for all heat input was observed. The time required to achieve the steady state condition at inclined position was found to be lesser than for horizontal position. Maximum temperature reached was also less for inclined position. Figure 20 Vapour temperature variation along Figure 21 Surface temperature variation along length for various heat input at vertical position. length for various heat input at vertical position Fig.17, Fig. 19 and Fig. 21 show the graphs of surface temperature along the axial distance for horizontal, inclined and vertical positions of the heat pipe respectively. Temperature of the surface was observed to decrease continously from evaporator section to condenser section. From these graphs it was concluded that the temperature drop was the least for inclined position of the heat pipe. Thermal Resistance of heat pipe was calculated by the equation given below [5] R th Te T Q Where, T e is average temperature of evaporator, T c is average temperature of condenser and Q is heat input in watts. Figure 22 Graph of Thermal resistance w.r,t, Heat Input for 0, 45 and 90 positions c Thermal resistance was calculated for 150 W, 200 W, 250 W and 300 W for horizontal position, vertical position and inclined position as shown in Fig. 22. The nature of the graph was found to be almost similar for all the three positions. With increase in heat input, the thermal resistance decreased at all inclination angles. Maximum resistance was noted for 150 watts and minimum resistance was calculated for 300 watts for all the three positions of heat pipe. The graph clearly indicates that for inclined position the overall thermal resistance was observed to be the least (0.035 C/W) of all the heat input supplied. AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 187

IV. Conclusions The experimental analysis of natural convection, stainless steel heat pipe with water as the working fluid was performed. The results concluded that steady state was achieved after 120 minutes of heat input for horizontal position of heat pipe, for all the ranges of power supplied. This time was reduced to 100 minute from 120 minute for the inclined position and was observed to be lowest (90 minute) for vertical position. The variation of temperature in axial direction of heat pipe explains the evaporation and condensation phenomenon after certain period of time. The thermal resistance of inclined position was found to be the least for all heat input. With increase in the heat input for a particular position, the thermal resistance decreased which clearly states the improvement of nucleate boiling in the evaporator section and hence the heat pipe performance was better at high heat input. The performance of heat pipe was found to be the best at inclined position (45 from the horizontal).isothermal behaviour of the heat pipe was also ascertained by experimental results. REFERENCES [1] Shoeib Mahjoub, and Ali Mahtrabroshan, Numerical Simulation of a Conventional Heat Pipe, World Academy of Science, Engineering and Technology, pp. 117-122, 2008. [2] H. Peter J. de Bock, Kripa Varanasi, Pramod Chamarthy, Tao Deng, Ambarish Kulkarni, Brian M. Rush, Boris A. Russ, Stanton E. Weaver, Experimental Investigation of Micro/Nano Heat Pipe Wick Structures, in International Mechanical Engineering Congress and Exposition IMECE2008-67288, 2008. [3] Dr. Hussain H. Ahmad and Raqeeb H. Rajab An Experimental Study of Parameters Affecting a Heat Pipe Performance, Al- Radidain Engineering, Vol. 18, pp. 97-115, 2009. [4] R. Manimaran, K. Palaniradja, N. Alagumurthi and J. Hussain Factors Affecting the Thermal Performance of Heat Pipe a Review, Elixir Thermal Engg. 37A, pp. 4143-4146, 2011. [5] Aloke Kumar Mozumder, Mohammed Shafiul Hasib Chowdhari and Abul Fahad Akon, Characteristics of Heat Transfer for Heat Pipe and Its Correlation, ISRN Mechanical Engineering, vol. 2011, 2011 [6] Arul Selvan Annanalai and Velraj Ramalingam, Experimental Investigation and Computational Fluid Dynamic Analysis of a Air Cooled Condenser Heat Pipe, Thermal Science, Vol. 15, No. 3, pp. 759-772, 2011. [7] Nouman Zahoor Ahmed, Pawan K. Singh, Isam Janajreh, Youssef Shatilla Simulation of Flow Inside Heat Pipe: Sensitivity Study, Conditions and Configuration, in International Conference on Energy Sustainability ES2011, 2011. [8] Barzin Gavtash, Khalid Hussain, Mohammad Layeghi, Saeed Sadeghi Lafmejani, Numerical Simulation of the Effect of Nanofluid on a Heat Pipe Thermal performance, World Academy of Science, Engineering and Technology, pp. 549-555, 2012. [9] R. Boukhanouf and A. Haddad, Simulation and Experimental Investigation of Thermal Performance of a Miniature Flat Plate Heat Pipe, Advance in Mechanical Engineering vol. 2013, 2013. [10] Thanaphol Sukchana, Chaiyun Jaiboonma Effect of Filling Ratios and Adiabatic Length on Thermal Efficiency of Long Heat Pipe Filled with R-134a, Eco-Energy and Material Science and Engineering, pp. 298-306, 2013. AIJRSTEM 14-576; 2014, AIJRSTEM All Rights Reserved Page 188