FLOOD SERIES DATA SHEET

Similar documents
Monitoring Solutions

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Affordable wireless monitoring without compromise

Affordable wireless monitoring without compromise

SMS GSM Alarm Messenger

Ontech GSM 9040/50. Reference Manual English -1 -

Wireless DC Voltage Detector

DATAssure. Laboratory wireless alarm & monitoring system

English. Doro CareIP Mobile. User Guide

Smart Wireless Sensor

status AW1 Plus WiFi Alarm System User Manual

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

They ll never know... LEADERS IN WIRELESS SECURITY SURVEILLANCE EQUIPMENT

Manual GPRS Data Logger PCE-GPRS 2


Mobeye CM2410 GSM fire alarm communicator

Cold chain monitoring technologies. Facility monitoring

Smart Wireless Sensor

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!


FarmGuard External Wireless Security

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

1. Functions of GPS locator ETLOC-30S 3

USER MANUAL Mobeye ThermoGuard CM2200

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Kwêbeam GSM/Interface/Repeater Module

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm


IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

Wireless Call Point ( )

Сontrol panel Contact GSM-9N

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

LIGHTNING PROTECTION SYSTEM

SC-F3G User Manual 1.0

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

User s guide Personal radio trigger Erik 9100

S3 Sim Secual Alarm system with GSM transmitter

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

COMMUNICATOR ET08 / ET081

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Product Catalogue. Complete Wireless Sensor Solutions SYSTEMS. 100% Peace of Mind! WEB ID WEB ID WEB ID

PERMACONN PM1030 Includes DI300. Installation Manual

GSM WIRELESS ALARM SYSTEM Model: GSM-0308W

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

FDCW241 Radio gateway Mounting

IP & SMS Alarm Communicator

2G & 3G GSM Wireless Beam Alarm

GSM RFID VOICE Alarm System

Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

CG500SKE SKYEYE GATEWAY USER MANUAL VERSION OCTOBER Disclaimers and Copyright

Laboratory Refrigerator/Deep Freezer TC 802

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

your silent and loyal servant

GRADESHIFT UDL INSTRUCTION MANUAL 2.5 APPENDIX

2G & 3G GSM Door Contact Alarm


Humidistats CH1, CH2, CH3

VDC. The Leading Enterprise Internet of Things Solution. Wireless DC Voltage Detection Sensors (0-50 VDC) General Description

2G & 3G GSM Portable PIR Alarm

Elderly Care Alarm System

Smart Hub. User & Installation Guide

GSM Senior Guarder GSM SOS Call System GSM Elderly Guarder

Wireless 0-5 Volt Meter Sensor

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

GSM 3G AUTO DIALLER PLUS

DET-RWATER Flood Detector Installation Guide

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

MOBILE CALL GSM Alarm System User s Manual

The complete wirefree security alarm solution

HOBO U30 Remote Monitoring Systems

1. Introduction. 2. Product overview

Chromatographic Air circulated Refrigerator, two-door TC 603

Intelligent Wireless GSM Alarm System

600 Range Dialer Installation Manual. Version 1.0

S3b Sim Secual / S3b Sim Vid Secual GSM Alarm System

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Specifications Minimum Typical Maximum Unit

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

ThinkPro Security and Automation Panel User Guide

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

IRIS Connect Series Quick Installation & Maintenance Guide. Version 1.1

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

APPLICATION DATA SHEET

Photoelectric Beam Detector

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

THE BELLMAN & SYMFON WAY Visit technical training

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

SilentMAlert. ClofieldMLimited. ProductMDataMSheetsM. PagingMSystem. Silent

Vesta Family. Home Smart Gateway Series. A Complete ZigBee Smart Home Solution. ZigBee Gateway Solution

Transcription:

FLOOD SERIES DATA SHEET Instr strument mentation tion for Science and a Industry try ISI sa-nv Rue du Doyenné 3-1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : sales@isi-be.com

FLOOD SERIES The flood series of radio transmitters and GPRS transmitters are have been specifically designed as a solution to flood or leak damage in buildings and for remote locations. The radio transmitters are connected to a highly responsive flood detection cable. These cables can be run along key areas enabling rapid notification of water leakage before serious damage can be done. The flood cable consists of eight cores wrapped around a central strain relief plastic core to provide some rigidity. Of the eight cores, two are the conductors. These are uninsulated copper so, if the cable comes into contact with water, it will short and provide an alarm signal. The cable is sheathed in a black plastic overbraid to keep the cores in place and to prevent the conductors shorting on any metal surfaces the cable may run over. The obvious inherent advantages of the flood series are that the units offer low installation costs and a minimal wiring solution. Each sensor is either powered by its own internal battery, which can last up to 2 years and is easily replaced or by an external 12V DC power supply. See page 2 for more information. The GSM transmitters can be used with float switches to detect a risk of flood in remote locations with immediate SMS alerts. See page 4 for more information. Product Features Radio and GPRS transmitter formats available High performance technology with advanced flood detectors Low power radio for long distance transmission (Over 3km over open ground) Up to 3 years battery life (depending on format of data retrieval, see below) Superior performance hardware with high accuracy sensors Easily accessible battery and USB socket Complies with RoHS, EU directives and WEEE Carries CE Mark Format Data Logger Radio Transmitter GSM Benefits Provides users with critical alarm notifications Assists users with damage prevention Can utilise a vast array of digital sensors such as float switches Provides users with the tools to warn of impending damage Radio Transmitter Functions Frequency Options: A range of frequencies are available between 433-458MHz. Country specific regulations apply. Radio Power: 10mW Radio Range: 3km over open ground Battery Life: Up to 18 months Software required: W400 RadioLog 8.4+ W119 RadioLog 8.4+ Validated software for Heritage W500 RadioLog 8.4+ Validated software for all other industries: Industrial, Food, Pharma & Hospital Hardware required: CR2 Controller SR2 Smart Receiver REP Repeater Accessories: 88706 3.6V AA Lithium battery N.B Instrument operating range -20 C to +60 C in a non-condensing RH environment GSM Functions Network Compatibility: For use on GSM/ GPRS networks at 850MHz to 1900MHz (Quad Band). Aerial Connection: SMA Socket Aerial Type: Stubby straight/right angle and remote mount on 2mtrs cable Power Supply: 5 x 1.5v alkaline C cells (recommended option) 12v DC connection 2.1mm DC Jack Battery Life: Up to 2 years Software included: Configuration Utility Accessories: 1.5v alkaline C cell battery G116 DC power supply G117 UK power cord G118 EU power cord G122 US power cord L455 AUS power cord N.B Instrument operating range -20 C to +60 C in a non-condensing RH environment Disclaimer The information contained herein is believed to be reliable. The IMC Group Ltd is not responsible for any incorrect or incomplete information on this datasheet and the information or product may be changed without notice. Customers should obtain and verify the latest relevant information before placing orders for IMC products. Issue: 1 1

Outdoor/Remote Monitoring For a cost effective solution the flood cable is connected to the wireless transmitter via an inline junction box using low cost 2-core signal cable. This allows the transmitter to be located in a good radio position and avoids running the specialist cable down walls or along floors which do not require flood monitoring. When the flood cable is shorted by water, the transmitter unit immediately sends a change of status signal six times to the receiving equipment. This multiple transmission is to ensure the signal is received straight away. Additionally, the RadioLog system can also be fitted with an alarm relay which triggers for example an autodialler, for out of hours instant notification. Another built in feature of RadioLog is the ability to sends email and SMS messages. For SMS messages additional hardware is required. Flood Cable Connecting Cable Junction Box SR2 PC SR2 Product Code: RL4805/ RL4806 (left) Dimensions: 150 x 88 x 50mm Weight: 485 grams Power Supply: 3.6 V AA Lithium battery Product Code: RL8008 (middle) Dimensions: 216 x 117 x 48mm Weight: 740g Power Supply: 12 Volts DC Case Material: Brushed stainless steel Product Code: FW01 (right) Dimensions: 200 x 120 x 80mm Weight: 950 grams Power Supply: 5 x 1.5V Alkaline C cells battery (recommended option) 9V DC connection 2.1mm DC Jack Technical Specifications Description 1 Zone flood alarm 2 Zone flood alarm 8-Zone flood alarm GSM FloodWatch Radio Transmitter Code Product Sensor RL4805-434.075 RL4806-434.075 RL8008-434.075 Input Channels: 1 2 8 4 FW01 Above picture: Flood cable Issue: 1 2

Outdoor/Remote Monitoring The flood series of radio transmitters have also been used to monitor water levels in outdoor and remote environments. The unit has a battery life expectancy of up to 2 years, creating a long term solution with easy access for battery replacement. The system stores up to eight telephone numbers for sending SMS messages to. Once an alarm has been registered the alarm message is sent to the first programmed number. If there is no response the other numbers are called in order until a response is received. The delay time for a response is user programmable. The Alarm message contains alarm number, alarm information and site name. All set up is done via USB interface using the simple setup program, which is supplied free. A heartbeat message can be programmed at user-defined intervals, low battery text message is sent on low battery. SIM card required. 1. Normal conditions The GPRS transmitter saves battery life by resorting to a sleep mode. 2. Flood conditions The GPRS transmitter wakes when activity occurs. The float turns upside down and the unit sends SMS alert to the programmed contacts. 1. 2. Product Code: RL4805/ RL4806 (left) Dimensions: 150 x 88 x 50mm Weight: 485 grams Power Supply: 3.6 V AA Lithium battery Product Code: RL8008 (middle) Dimensions: 216 x 117 x 48mm Weight: 740g Power Supply: 12 Volts DC Case Material: Brushed stainless steel Product Code: FW01 (right) Dimensions: 200 x 120 x 80mm Weight: 950 grams Power Supply: 5 x 1.5V Alkaline C cells battery (recommended option) 9V DC connection 2.1mm DC Jack Technical Specifications Description 1 Zone flood alarm 2 Zone flood alarm 8-Zone flood alarm GSM FloodWatch Radio Transmitter Code Product Sensor RL4805-434.075 RL4806-434.075 RL8008-434.075 Input Channels: 1 2 8 4 FW01 Above picture: CSM cable ball float switch This and similar items can be ordered/ sourced from IMC and will work with the FloodWatch transmitter. Issue: 1 3

Intelligent monitoring and control solutions: In Buildings In Transit Outdoor/Remote Instr strument mentation tion for Science and a Industry try ISI sa-nv Rue du Doyenné 3-1180 Brussels Tel +32 (0) 2 343 30 81 Fax 02/ 343 12 05 web : http:// www.isi-be.com mail : sales@isi-be.com