NOVEL BOREHOLE- AND TEST PROCEDURES FOR UNDERGROUND GAS STORAGE ASSETS BY USING AN INTELLIGENT PIG FOR DOWNHOLE INSPECTIONS

Similar documents
HELPCOS THE HELICOPTER BASED PIPELINE CONTROL SYSTEM OF VNG - VERBUNDNETZ GAS AG

INCREASED RELIABILITY / REDUCED RISK BY APPLYING INTELLIGENT PIGGING TECHNOLOGY TO INSPECT COILS IN PROCESS HEATERS

CASED HOLE SERVICES

A new fully digital system for RT inspection of metal tube to tube sheet joints of heat exchangers

Managing technical risks

QuestIntegrity.com CHALLENGE CONVENTION

Chapter 1 Introduction

SOLUTION MINING RESEARCH INSTITUTE

Technology, expertise, quality, and service. Slickline. Measurement and activation services

TECHNICAL PUBLICATION

RELAY. Digital Slickline System INTELLIGENT SLICKLINE CONVEYANCE FOR WELL INTERVENTION

Mud-Motor Characterization

6 th Pipeline Technology Conference 2011

Sensor Network Design Technique for Monitoring Railroad Structures

Compression of Fins pipe and simple Heat pipe Using CFD

International Gas Union Research Conference Limitation of detection range in guided wave testing of buried pipeline

Surviving the Survivable Cable Crunch

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

RLDS - Remote LEAK DETECTION SYSTEM

Automated Infrared Thermography Complete Solutions from a Single Source

FIBER-OPTIC SENSING TECHNOLOGIES

Study and Design Considerations of HRSG Evaporators in Fast Start Combined Cycle Plants. Govind Rengarajan, P.E.CEM, Dan Taylor

Roxar Flow Measurement Topside Flow Assurance Solutions. Søren Forné, Sales Manager Scandinavia

A Comprehensive Approach to Leak Detection

Distributed Temperature Sensing. On Demand. OPTICall. Thermal Profile and Investigation Service

Fire Sprinklers Working Group Final Report

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

GROUNDING AVOIDANCE SYSTEM (GAS)

55 years of know how on flame monitoring systems from Leipzig

REAL-TIME SOFTWARE TO ESTIMATE FRICTION COEFFICIENT AND DOWNHOLE WEIGHT ON BIT DURING DRILLING OF HORIZONTAL WELLS

Monitoring of Penetration System Performance due to ISO by using Test Panels due to ISO

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

Ground Freezing Bilfinger Spezialtiefbau GmbH

NEW APPROACHES IN BATCH CENTRIFUGAL DESIGN AND ITS OPERATIONAL BENEFITS

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

NATIONAL INSTITUTES of HEALTH FUME HOOD TESTING PROTOCOL. For CONSTANT VOLUME FUME HOODS

SONAPHONE. Performance test of steam traps Supplement to the operating manual

Geological disposal program of Switzerland

Smart Defrost Control for Refrigeration System

Y003 Multi-offset Seismic Acquisition Using Optical Fiber Behind Tubing

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

WHAT IS LASER ULTRASONIC TESTING?

SITRANS F. SITRANS FUG1010 Clamp-on Gas Flowmeters. Answers for industry.

DYNALINK TELEMETRY SYSTEM Reliable, real-time, wireless downhole communication

The Roxar Downhole product portfolio Permanent downhole monitoring system

Fire Protection Regulatory Approach for Nuclear Power Plants in Canada

Induction Billet Heaters with Enthalpy Controlled Zone Heating

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

Piles subject to excavation-induced soil movement in clay

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

Groundwater Flow Modeling of ROW Bioswales Adjacent to Residential Buildings

OptiDrill. Real-time drilling intelligence service

Dynamic Lights Towards Dynamic, Intelligent and Energy Efficient Urban Lighting

Procedure for the Approval of New Fire Detection and Alarm Technologies

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

sense the difference 23 rd April 2018

CROWD-SOURCED REMOTE ASSESSMENTS OF REGIONAL-SCALE POST-DISASTER DAMAGE

INTRODUCTION: COOLING TOWER INTRODUCTION: COOLING TOWER FANS. The cooling Tower is commissioned since 2006 and 1 st failure was encountered in 2007

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

BEKA ceiling heating versus traditional underfloor heating

Evaluation of the Incon TS-LLD Line Leak Detection System

ICONE DRAFT Proceedings of the 16th International Conference on Nuclear Engineering ICONE16 May 11-15, 2008, Orlando, Florida, USA

When Precision is not good enough

Mapping the orientation of downhole sensing cables and control lines using an engineered hybrid distributed acoustic sensing system

SOCIETY OF FIRE PROTECTION ENGINEERS POSITION STATEMENT P THE ROLE OF THE FIRE PROTECTION ENGINEER IN THE CONSTRUCTION DESIGN PROCESS

Sensor Technology. Summer School: Advanced Microsystems Technologies for Sensor Applications

FISHING WITH THE AGITATOR SYSTEM

LAUDA TecInfo Viscometry No 3

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

OPTIMISATION OF NOZZLE ARRANGEMENTS ON DESCALING HEADERS. Jürgen W. Frick Lechler GmbH D Metzingen / Germany

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

PREPARED FOR: PLATTEVIEW ROAD CORRIDOR STUDY EXECUTIVE SUMMARY

DRAFT NFPA 805 TRANSITION PILOT PLANT OBSERVATION GUIDANCE

FIBER-OPTIC SYSTEM FOR MONITORING EXTENDED OBJECTS «FOSM»

SUBJECT: Waterfront Hotel Planning Study Update TO: Planning and Development Committee FROM: Department of City Building. Recommendation: Purpose:

Evaluation of the Red Jacket Fx1, Fx2, Fx1V and Fx2V Line Leak Detectors For Hourly Monitoring on Rigid Pipelines. Final Report

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Long-range Ultrasonic Non-destructive Testing of Fuel Tanks

Contents. EN :2012 (E) Issue 5 ( ) Page

Best Freeze Drying Solutions

Integrated Cased-Hole Services. Maximum Well Performance

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

CO 2 Laser. High Reliability and Performance

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

ACCESS AND ALARM SAFETY SYSTEMS ACTIVITIES FOR THE 2012/2013 LONG SHUTDOWN*

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Greenhouse Automation. Small or big solutions State-of-the-art and cost-effective.

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

DEVELOPMENT OF A MODULAR AND COMPACT CHARGE AND DISCHARGE UNIT FOR LARGE-SCALE SOLAR THERMAL SYSTEMS

Fixed fire protection solutions

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

ECB S Recommendation for Service, Repair and Modification Operations on ECB S Certified Secure Storage Units, Data Cabinets and Data Rooms

HEUFT SPECTRUM. Modular HEUFT systems of the new generation. Highly automated, self-explanatory and SIMPLY EASY!

Nothing lasts forever planning for successful mine closure

SECTION SECURITY TESTING AND COMMISSIONING

Transcription:

23rd World Gas Conference, Amsterdam 2006 NOVEL BOREHOLE- AND TEST PROCEDURES FOR UNDERGROUND GAS STORAGE ASSETS BY USING AN INTELLIGENT PIG FOR DOWNHOLE INSPECTIONS Main author Claudia Becker, Untergrundspeicher- und Geotechnologie-Systeme GmbH, Mittenwalde, Germany Co-authors Herr Winfried Becker, VNG - Verbundnetz Gas AG, Leipzig, Germany Robert Scheler, VNG - Verbundnetz Gas AG, Leipzig, Germany

ABSTRACT Defects both within the base material and within areas of casing connections (screwed / welded) can particularly affect the integrity of boreholes apart from numerous other operational demands/stresses as well as material and environment characteristics. The weld condition is vitally important for the evaluation of welded installed casings. For this reason on behalf of the VNG - Verbundnetz Gas AG by the UGS - Untergrundspeicher- und Geotechnologie-Systeme GmbH 2004 a comprehensive research regarding an appropriate inspection method/inspection tool that offers improvements to previously used methods/tools was done. Since in the pipeline industry integrity evaluations of pipelines based on the inspections results of intelligent pigging systems are successfully performed, in connection with the research also the possibility of the application of an adapted standard pigging system of the pipeline industry for downhole inspections was investigated (figure). The research tied in with former investigations of the UGS GmbH. On the basis of the study The application of intelligent pigging systems in the field of downhohle inspections and after the consideration/evaluation of different tool concepts, it could be estimated that the umbilical operated inspection system offered by GE Oil & Gas Pipeline Solutions, PII - Pipetronix in partnership with the company AGR - PipeTech AS basically achieves the main requirements for an underground application. The inspection tool is based on the conventional ultrasonic inspection principle combined with the TOFD-principle (time of flight diffraction). It offers a tool-cable-connection by default and therefore also an online data communication / data transfer. With the inspection tool of PII / AGR the acquisition of the casing condition (production casing / last cemented casing), viz the measurement of geometry, wall thickness, corrosion and crack detection, shall be realized. Therefore the special emphasis is the investigation of welded casing connections with their specific flaw indications (corrosion-/ crack features, manufacturing defects), which is not possible with the present used inspection technique. Within the project progression PII as the case may be AGR rebuilt the inspection tool from the formerly flexible to the currently rigid tool configuration. In addition a tool-cable-adaptor for the connection to a standard Wireline-Service for downhole applications was developed. The results of the witnessed trial (testing casing) and first downhole experience in storage well will be reported in the presentation. Statements regarding the tool-movement within vertical casings as well as statements in terms of the measuring ability of the inspection tool during the tests will be demonstrated. In the context of the analysis/evaluation of the inspection data collected during the various tests a comparison between the results of the inspection campaigns and the results of the inspection tool used so far will be likewise led. On the basis of the increase in information possibilities for extending the present evaluation standards with respect to the quantifiable reliable evaluation of casing conditions will be explained. Within the presentation the possible evaluation of girth welds as well as potential statements in terms of the production period/technical risks will be prioritized. Additional analyses/research programs, such as fracture mechanical analyses, for the establishment of updated evaluation directives will be introduced.

TABLE OF CONTENTS 1 PRELIMINARY REMARKS 2 DOWNHOLE INSPEKTIONS 2.1 RELEVANT FLAWS 2.2 TECHNICAL REQUIREMENTS FOR INSPECTION-TOOLS 2.3 EQUIPMENT CONFIGURATION OF INSPECTION TOOL 3 TOOL TESTS 2005 3.1 WORKSHOP TEST 3.2 FUNCTIONAL TESTS 3.3 FIELD TEST 4 CONCLUSIONS

Paper 1 PRELIMINARY REMARKS During the last 20 years the UGS - Untergrundspeicher- und Geotechnologie-Systeme GmbH (UGS) has developed a method for evaluation of downhole equipment for underground storage facilities. Right now there is no official legislation regarding the evaluation of mining safety of downhole equipment available. For this reason on behalf of the VNG - Verbundnetz Gas AG (VNG) standard evaluation rules concerning all storage facilities of VNG were developed. Those rules had been approved by the mining authorities as standard procedures. Associated with that, continuous revisions have to be specified. A very special issue of the evaluation of downhole equipment is the identification of the casing geometry by using modern geophysical logging services. There exists an extensive evaluation routine by the use of the finite elements method based on survey logging data. For further developments the key aspects of activity are the advancement of the methodology as well as the use of new tools which can achieve more logging data, higher resolution and higher accuracy of measurement. On behalf of the VNG the UGS did a comprehensive research regarding an appropriate inspection method / inspection tool that offers improvements to previously used methods / tools. Therein also the possibility of the adaption of standard pipeline-pigging systems for downhole inspections and therewith possible test-procedures were investigated. The umbilical operated inspection system offered by GE Energy, PII Pipetronix (PII) in partnership with the company AGR - PipeTech AS (AGR) turned out to be most suitable for underground applications. Using this tool the investigation of the casing condition (production casing / last cemented casing), viz the measurement of geometry, wall thickness, corrosion and crack detection, was essential. The special emphasis was the investigation of girth welds with their specific flaw indications (corrosion-/ crack features, manufacturing defects). 2 DOWNHOLE INSPECTIONS 2.1 RELEVANT FLAWS The integrity of casings can be particularly affected by relevant flaws within the base material as well as flaws within the casing connections (girth welds). Possible flaws can be: - Corrosion-dependent areal defects (metal loss, wall thickness thinning), - Cracks within the base material and in girth welds, - Fabrication defects or - Defects due to mechanical loads/operational demands. During the project progression the main focus was the detection of metal loss and cracks. 2.2 TECHNICAL REQUIREMENTS FOR INSPECTION-TOOLS The new inspection tool should be preliminary used within an 11 3/4" last cemented casing over a gas filled storage cavern. Thereby the casing was totally filled with saturated brine and backed up by different packer systems.

In order to be applied the tool configuration had to meet the main following requirements: - It must be a stiff tool configuration, - The system must be adapted to a standard wire line-system considering standard rated breaking points, - The tool must insure online data communication and - The tool must be pressure-resistant for a maximum inspection depth of 600 m. Within in certain tests the tool had: - To prove the ability of bi-directional moving through a vertical casing, - To investigate the present casing condition, like - Wall thickness and - Casing geometry and possible ovalities; - To prove the ability to measure/investigate existing defects within the base material and girth welds while meeting the set requirements, such as - The detection and sizing of defects and - The differentiation into different defect types; - To document, interpret and evaluate all measured defects, - To reveal measurement and tool restrictions respectively. 2.3 EQUIPMENT CONFIGURATION OF INSPECTION TOOL The inspection tool is based on the conventional ultrasonic inspection principle combined with the TOFD-principle (time of flight diffraction). The tool provider rebuilt the inspection tool from a formerly flexible to the currently rigid tool configuration. During the project the inspection tool consisted of two modules, one for the wall thickness measurement and the other for the circumferential crack detection. Figure 1: Tool modules for crack detection (left) and wall thickness measurement (right) The standard pigging system offers a tool-cable-connection by default and therefore also an online data communication/data transfer. However due to its technical specification and material condition the existing cable system could not be used for downhole inspections. For this reason a toolcable-adaptor for the connection to a standard Wireline-service was developed.

Figure 2: Tool-cable-connection including adaptor piece and standard cable head For all adaptation procedures, functional tool tests as well as the Wireline service during the field test the project parties worked in close collaboration with the company Schlumberger (SLB). For the field test a Cable Interface Service (CIS), viz the supply of sufficient wire line equipment and the recording of the depths and loads during the inspection campaign was provided by SLB. 3 TOOL TESTS 2005 3.1 WORKSHOP TEST For the performance of the workshop test a testing casing containing 3 girth welds and artificial defects were manufactured. By applying mechanical methods as well as sparks erosion artificial defects (root defects, pores, pitting, fabrication defects and slag) were placed in/on the testing casing. All defects were documented in order to insure the subsequent comparison between the actual and measured defects. The results of the workshop test can be summarized as follows: - Bi-directional moving through a vertical casing was successful, - The tool was able to pass changes in wall thickness, offsets and eccentricity and - Online presentation of the inspection data was possible. Wall thickness measurement: - Clearly identification of all girth welds, - Detection, localization and sizing of defects (wall thickness thinning, areal defects, pitting), - Differentiation into different defect types, - Documentation, interpretation / evaluation of defects and - Comparison between actual and measured defects. Crack detection: - Inspection of all three girth welds, - Detection, localization and sizing of flaws within the welding areas, - Sporadically differentiation into different defect types and - Number of placed defects number of measured defects. Based on the results of the workshop test the accomplishment of different functional tests and finally the realization of a field test were decided. 3.2 FUNCTIONAL TESTS In order to meet all safety regulations and due to the fact that for the first time an adapted pipeline pigging system was used for downhole inspections several functional tests had to be performed prior to the actual field test.

The tests are as follows: 1. First adaptation test for the verification of the mechanical and electrical tool-cableconnection, 2. Pressure test of the adapted inspection tool at a test pressure of max. 85 bar, 3. Final functional test in order to prove the complete tool functionality after the pressure test and 4. Tool check at the test-site and final acceptance test. The results of all four tests approved the use of the adapted pigging system for a casing inspection over a gas filled storage cavern. 3.3 FIELD TEST For the field test the main goals were the initial mentioned requirements for downhole inspection tools. By using the adapted tool system the actual casing condition (production casing / last cemented casing) should be analyzed, viz the measurement of geometry, wall thickness, corrosion and crack detection. The special emphasis was the investigation of girth welds with their specific flaw indications (corrosion-/ crack features, manufacturing defects). The results of the field test can be summarized as follows: - Bi-directional moving through a vertical casing, maximum depth was 540 m, - Appearance of few restrictions in movement due to the little tool-weight, interior casing roughness and the low operation-speed, - The tool was able to pass changes in wall thickness, offsets and eccentricity, - Tool-cable-connection mechanically and electronically functional, - Selective data transfer, viz simplified online presentation of the inspection data was possible and - Appearance of tool restrictions due to the increasing pressure. Wall thickness measurement: - Identification of all girth welds, - Detection, localization (internal / external), sizing of selective and areal defects (wall thickness thinning, areal defects, pitting) and - Documentation, interpretation / evaluation of defects. Crack detection: - Partly inspection of selected welding areas and - Tool restrictions due to the increasing pressure. In order to perform further field tests several optimizations are necessary. The optimizations regard: - The inspection tool incl. fabrication of a tool housing, - The tool-cable-connection, - The online presentation of the inspection data, software optimization, - The data recording, - Repeatability of the inspection data, - The sensor constancy and - The amplification of the inspection intervals (temperature / pressure resistance).

4 CONCLUSIONS With the field test the bi-directional movement through a vertical casing could be proved even though few restrictions appeared. By increasing the tool weight with the use of drill collars and by raising the operation-speed the bi-directional movement could be smoothed. For further projects the inspection tool as well as the software has to be optimized. Furthermore the repeatability of the inspection data has to be proved (reference measurements). A decision-making in terms of the usability of an adapted pigging system for downhole inspections can not only be based on the performed field test because only a partly comparison between different inspection tools but not the compensation against the actual defects were possible. A realistic evaluation regarding the suitability of such adapted pigging system can only be given after accomplishing the inspection of a production casing. Thereby a real comparison between the measured and actually present defects can be made after the production casing was taken off and be analyzed. For the upcoming years summarized the following steps have to be accomplished: - Modification / optimization of the inspection tool and the software, - Development of smaller tool dimensions, - Development of the module for axial crack detection, - Further field tests, viz inspection of production casings to assure the comparison between the measured and actually present defects and - Update of existing evaluation standards on the basis of the increasing in information.