Different types of Fire Alarm System

Similar documents
Advanced FireAlarm Panel 1-4Loop

The EN54 Part 2, 4 and 13 Fire System

False Alarm Management

Reliably Advanced Extinguishing Control

Reliably Advanced Extinguishing Control

Intelligent Single Loop Fire Alarm Control Panel

The Leading Multiprotocol Intelligent Fire Panel

Solution F2. Fire Alarm Control Panels one step ahead.

False Alarm Management

Intelligent 2 & 4 Loop Fire Alarm Control Panels

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel

Consultant Specification AGILE Wireless Fire Detection System

The EN54 Part 2 & 4 Fire System

For Complete Fire and Gas Solutions

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Australia s Advanced Fire System

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Product Data Sheet. Remote Terminals. Features:

The Leading Multiprotocol Intelligent Fire Panel

ZXSe Range Data Sheet

Intelligent Security & Fire Ltd

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

The Worldwide Fire System ANSI/UL 864 9th Edition

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

HART XL High Sensitivity Smoke Detection

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ID50series. intelligent fire alarm panels

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent Security & Fire Ltd

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Answers for infrastructure. Cerberus PRO enjoy protecting

LaserFOCUS VLF-250 Engineering Specification

Vigilant MX4428 Fire Alarm System

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

SUPREMATouch. Modular Fire & Gas Detection System

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

Fire control panels FC726 FC726-XA

Installation, Operating and Maintenance Manual

Fire alarm system EBL512 G3

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Product Catalogue. Intelligent Control Equipment for Life Safety. Issue 1

Engineer Paging. Staff Paging. Deaf Alert.

DCS-100. intelligent damper control & monitoring system

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

The Worldwide Fire System ANSI/UL 864 9th Edition

CSP-204 CSP-208 CSP-104 CSP-108

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

The Worldwide Fire System ANSI/UL 864 9th Edition

intelligent fire alarm ID60series panels

HART XL High Sensitivity Smoke Detection

Planning Instructions MEW01472 Revision -

Solution F1. Fire Control Panels the new generation

Fire control panel detect 3004 plus and accessories

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

user manual Document No , Revision 03 November 2015

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

CATALOG NUMBER. Features. Description

On the job around the clock 24/7: Fire detection systems

Intelligent Addressable Fire Alarm System

Planning Instructions MEW01776 Revision -

Laptop / PC Programming Manual

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

Why Hart XL Aspirating Smoke Detection?

The supplier and installer of the system should be approved by the local civil defence authority.

System 800 Addressable Fire Detection & Alarm System

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

SUPREMATouch. Modular Fire & Gas Detection System

ID2000. intelligent fire alarm panel

TrueAlarm Fire Alarm Controls

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

AUTROSAFE 4 A new level in interactive fire detection systems

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Addressable Fire Alarm Control System 2100 series

Touch 10. The operation and functions described in this manual are available from Software Version onwards.

Modular Fire Panel 5000 Series Just as flexible as your plans

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Electronics Ltd. Life Safety System Specialists

Security Alarm Systems

Conventional & Twin-wire Fire System

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

CATALOGUE Fire Alarm Systems

Healthy. Atmosphere. for Pigs and Poultry. for a

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

HERCULES 6 GRAPHICS SYSTEM

/ / White Paper. Focusing on user experience

Fire control panels FC360

Transcription:

Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer has different loop capacity. Aspirating Smoke Detection System Independent unit installed for very early smoke detection system. It can be connected to Fire Alarm system. Video Smoke detection system Standalone system can be connected to Fire Alarm system

Easily More R&D & Support Over half the business dedicated to R&D and Support Investment in leadership Less requirement for support Leading industry expertise Sit on industry bodies across the globe Worldwide approvals Industry first approvals EN54 Part 13 Entire Australian product range to BCA AS1670

Lifetime Personalised Online Support Open support tickets View support history Download software/firmware Download warranty certificates Book training Download training certificates Download manuals etc Request marketing support Book product demos Order Approved Partner certs Available 24/7 from anywhere

Approvals & Memberships

Legendary Customer Service Training & Tech Support

Instant telephone and online support Team of over 30 fire experts Designers, coders, engineers Full system network simulators Full system training at 3 UK and 3 overseas tech centers Lifetime training passport On site tech support service After sales service team Built to fit individual customers

The Leading Multiprotocol Choice

Choose your panel, Choose your detector, Choose your installer. Real Freedom. Advanced Quality.

The Fire System for the EN54 World

The Fire System for the UL 864 World

Ultra-dependable Extinguishing Control

Fire Alarm System Features Design Guideline NFPA 72 UL Listed & En Approved Fire Alarm Systems. 1 to 4 loop capacity with UL listed panel. Loop capacity 125 detectors/devices per loop. 1 to 8 loop capacity with En approved Panel. 240 detectors + Devices per loop. (En Approved System) Redundant CPU Panel available. Touch Screen Repeater panels All Devices are with inbuilt isolators. Lite detector series available without inbuilt isolator. Networkable upto 200 nodes.

EN54 Part 13 Be wary of products designed to (all advanced products are approved) Ensure all components are sourced and manufactured in house Indication and response times from CIE are set-out in the EN standards and EN54-13:2005 (E) 4.3.2.1 states that a fire alarm condition shall be indicated on the main CIE with 20 seconds. The typical delay for a panel to indicate a fire from any zone on 50 panel ad-net+ network is less than one second and well within specification on a fully loaded 200 panel system.

EN54 Part 13 Requirements: Component approvals Transmissions paths All components are individually tested and certified to the relevant harmonised product standard Work together and fully operate as specified Do not interfere with any mandatory function For system compliance, all components that are to be connected must be identified in the documentation and must be tested for compatibility All components fully approved to the appropriate harmonised standard. All components been tested together for system compatibility in all modes of operation. A system capable of indicating partial short and partial open conditions for ALL possible load conditions. (Can be hidden until fire condition)

MxPro 5 Our Most Advanced Panel

MxPro 5 Features EN54 Parts 2,4 & 13 1-8 Loop 3 protocols Up to 2,000 zones 200 Node networks True peer-to-peer network Fault tolerant networking 200,000 devices per network Unique on-board diagnostics tools On-board scope RCTs, BMS, ipgateway, I/O drivers Huge range of peripherals Simple installation and configuration Primary/second activation. i.e. Flash if fire started here. Drift and new Warning State can be downloaded to service tool. Dirty detectors can give warning instead of a fault

MxPro 5 Features Autolearn facility In built P-Bus 20 on board programmable LEDs 4 programmable push buttons 201 programmable false alarm management zones per panel Complete device history from any panel Timed enablement of isolated zones, input and output devices Advanced logic and easily programmed cause-and-effect Service Tool Backward compatible Multiprotocol network MODBUS/BACNET compatible

Programming Up to 200 Output Groups available per panel Panel is pre-configured with default Output Groups for on-board and loop powered devices Outputs can be programmed to operate upon Zone Range, Time-Clock, General Event, Input Events & Logic Statements Programmable Ringing Styles provide a solution to programming Phased Evacuation Common graphical LCD user interface & software Common menu structure for day-to-day operation of panels Tools configuration software common to all panels Powerful Cause & Effect features Common range of peripheral devices All Outputs are fully programmable to respond to any combination of Input signal type (Logic) Outputs can be programmed across network by zone, input device, general event, time clock, or logic statement Test alarms can be programmed to have a completely independent Cause & Effect (Local Panel) User-friendly Windows based Dynamix

False Alarm Management Day/Night sensitivity modes Investigation delay for selectable Inputs and Outputs Multiple On-board, 7 day time-clocks can be used to control any Input/Output device Any Input device can be gated with a time clock to provide a manual control Categories of False Alarm Management Alarm Verification features can be used to help verify if an activated condition from a device is considered to be a genuine alarm before the fire alarm condition is displayed on the panel. Investigation Delays to Outputs can be used to delay the operation of certain outputs after the Fire Alarm condition is displayed

False Alarm Management Divide a building into up to 10,000 independent false alarm building areas Network points can be assigned to the building areas Assign verification and investigations to the building areas Assign detection thresholds, sounder styles etc.

Intelligent Alarm Acknowledgeme nt & False Alarm Reduction

False Alarm Management Verification Method; Type A (Not Displayed) or Type B (Displayed) If Type B selected Verifying (Pre-Alarm) is displayed on the panel during the verification period Verification Time- If one or more devices in the same area stays in alarm for longer than time specified the panel will enter a fire condition. Min Time in Verification - Devices will not return to normal until this time has time has elapsed Second Stage Time - Further time to clear the alarm condition if stage 1 is acknowledged ( all other times n/a in stage 2). Sounder Ringing Style - Any sounders operated during verification will use this ringing style (Note, irrespective of output rules!) Max Areas in Verification - Maximum areas allowed in verification mode simultaneously across the network. (Fire Alarm displayed if number exceeded) Time clock Day / Night time settings

False Alarm Management Alarm verification is used in Building Area 1 during the day time only The verification time can be extended using a designated acknowledgement button Alarm Verification is used for all Heat, Smoke and Multi sensor detectors in the area. Other devices (such as Input modules and Call Points) are selected by device. All Sounders and Beacons in Area 1 will be operated during the verification period when the device activated is also in area 1. This will happen automatically regardless of any cause and effect rules. Relays would not be operated.

Integrated Smoke & Fan Control

Integrated Smoke & Fan Control Integrated control interface and PCBs Simple configuration software colour coded for status settings Set multiple smoke and/or damper compartments Define compartment detection zones Map fans, duct probes and node settings

MxPro 5 Networking

Networking Up to 200 control panels. Peer to Peer, token passing ring technology Up to 20Km as Standard. Fully monitored and Secure network. Communications bus all achieved using standard 2 core fire resistant cable Capable of withstanding single faults between nodes Communications bus all achieved using standard 2 core fire resistant cable Fibre optic networking Non-confusing zone config (Up to 2000) Allows larger sites to be protected by distributing fire panels instead of taking all detection circuits back to one point Increased system integrity, reduced installation costs Allows information from any input or output point to be passed over network and displayed on any MxPro 5 control panel Two types of network available: Standard Network Radial configuration Fault-tolerant Network Loop configuration

Software Overview Designed by fire engineers to be quick, intuitive and easy to use. Design Check Calculator Dedicated Service/Config/Maintenance tools Virtual panel & logo programming Service Tool provides a complete Device History data base providing information such as device installation, test, isolation to information such as last activation. Windows based

48 Way I/O 48 way programmable I/O driver card Up to 16 cards can be connected = 768 I/O Switch/LED module Flexible programming Internal RS 485 Bus

LED Mimic Display Card Can be mounted locally in a multi-loop panel to display zones in fire Alternatively can be mounted in bespoke remote enclosure together with a building plan All mimics are fully programmable units that connect to the network

The ipgateway is a web based IP solution providing the following functionality: Internal/External IP Network Access Browser in-built to ipgateway Direct Network Connectivity Full Level 2 Management Control Network Event Log Events can be sent via Email

MxGraphics HD resolution 16 million colours 2000 graphics & zoom explorer Test Instruction Page for operators Isolation and fire panel controls Unlimited history/log Report printing Site graphic control Site navigation Event listings History search

SmartCube What is it? SmartCube is a Black-Box PC for remote panel networks that are connected using a TCP/IP solution. Each remote network requires a BMS/Graphical Interface. Each remote network connected via Smart Cube supports a maximum of 200 networked panels. Maximum number of 2047 remote networked panels using software license offset.

Smart Cube How it works? Advanced Fire Network (see text) Advanced Electronics BMS interface RS232 RSM TCP/IP ethernet to local network or the internet Maximum number of panels per Network is 200!

Smart Cube Basic Network Schematic RS232 to monitored equipment RS232 to monitored equipment RS232 to monitored equipment RSM module RSM module RSM module Existing site ethernet network AMX1

Smart Cube Advanced Network Schematic

Thank you.. Questions??? Swarjita Rawool e-mail - swarjita@newagefireprotection.com HP - +91 97 6966 1333