Technical Data Sheet

Similar documents
Adsorption Chillers Energysmart Green Cooling

Guide Specifications

SOLAR COOLING TECHNOLOGIES

Solar Heating and Cooling Systems

LECTURE-18 Vapour Absorption Refrigeration System

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

FEATURS HYUNDAI CLIMATE CONTROL CO., LTD.

Solar Air-Conditioning and Refrigeration - Introduction

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

SPACE HEATING AND COOLING A.M. NARAYANAN

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Pool heating, efficiently

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

UNIT 4: REFRIGERATION PRINCIPLE

Gas-Fired Double-Effect Chiller-Heater

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 7, Issue 11, May 2018

Methods of Desiccation

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Patent Pending CO 2 OLrac. Blade Server Cooling

Experimental Investigation of Two Stages Adsorption Chiller with Four Generators Utilizing Activated Carbon and Methanol as Working Pair

DEVELOPMENT OF THE WORLD S FIRST SMALL-SCALE TWO-STAGE ABSORPTION CHILLER/HEATER/HOT-WATER SYSTEM

K.F. Fong *, C.K. Lee, T.T. Chow

White paper Compressed air drying

INSERT NEW PHOTO HERE

Air Conditioning and process cooling Energy Components at a Glance

RISKY REFRIGERANTS AND REDUCES ELECTRICAL CONSUMPTION BY

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

SOLAR AIR CONDITONING SYSTEM USING DESSICANTS

R07. Answer any FIVE Questions All Questions carry equal marks *****

Remote Conditioners. RC-Series. ZPRC Series

ISO-9001:2008 DESICCATORS CATALOG. Phone: Fax: Web:

CUSTOMIZED ABSORPTION HEAT PUMPS FROM INDIAN INDUSTRY

products 22 º C Ventilation Air Conditioning Refrigeration Maritime Absorption Chiller Inside PROVIDED BY HEINEN & HOPMAN

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

» WITH REGASORP ROTARY HEAT EXCHANGER

Remote Conditioners. RC-Series. ZPRC Series

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Why Vaillant? Because the ecotec delivers day in, day out. Vaillant ecotec boiler range. The TECHNICAL Brochure

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

Recent Advances in Energy, Environment and Economic Development

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

WATE R -C OOLE D WATE R C H ILLE R S

LG Electronics AE Company, Commercial Air Conditioning

Low Energy Air Conditioning

ARV.

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

Refrigeration Compressed Air Dryer Boreas Variopulse

[Mali*, 4.(12): December, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

LG Electronics AE Company, Commercial Air Conditioning

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

Technical Seminar 2014 Gas Absorption Heat Pumps

Thermodynamics II Chapter 5 Refrigeration

Kawasaki centrifugal chiller using water as a refrigerant. Sep 26 th 2017 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Alternative Cooling Processes 1. Classification of Refrigeration Cycles. Agenda. Hans Jonsson

Low-Power Air Conditioning Technology with Cold Thermal Energy Storage

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

RetroAire VPRC/VPRH. Single Packaged Vertical Unit R-410A Refrigerant

Mechanical Systems Thesis Proposal: Calvert Memorial Hospital Prince Frederick, MD Holly Mawritz

HVAC Equipments and Systems

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Trane CDQ Desiccant Dehumidification

Solarthermische Kleinanlagen aus Sicht eines Systemanbieters

2 Technical overview of active techniques

Heat pump and energy recovery systems

GENERAL INFORMATIONS

Using the Open Source SorpSim for Simulation of Sorption Water Heating Applications

Enthalpy Wheel and its Application in Air Conditioning

GAS ABSORPTION HEAT PUMP

DEHUMIDIFICATION ADVANTAGES FOR WATER TREATMENT PLANTS

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Filter Driers with Replaceable Core

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

DES CHAMPS PRODUCTS 85% 4,400 CFM

Purpose of Refrigeration

GLYCOL REGENERATIVE METHOD A

REFRIGERATION COMPRESSED AIR DRYER BOREAS VARIOPULSE

EU Air Handling Units with SEMCO EXCLU-SIEVE

SOLAR HEATING AND COOLING FOR THE SOLAR CITY GLEISDORF

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Commercial 1 Track Unit 5 Gas Cooling

H4T R410A. refrigerant

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

DEHUMIDIFIERS & VENTILATORS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

recooler HP EQKR HEAT PUMP

Transcription:

Technical Data Sheet Bulletin : BAA:D0054 Effective : April. 06, 2015 Supercedes Date : ADSORPTION CHILLER ADC Series C-FRAME FEATURE HIGHLIGHTS * Ultra low electricity consumption * Ease of maintenance * Zero ozone depletion potential * Advanced microprocessor control * No dangerous chemicals * Designed for outdoor installation * Very few moving parts * Wide temperature ranges allowed MODEL C-40 C-30 C-20 C-10 Electrical Rated Capacity (Tonnes) 41 30 20 10 Voltage 415-3-50/60 Frequency 50/60 Hz Chilled Water Operating kw Consumption..0.6 kw Inlet Temperature ( C) 12.8 12.8 12.8 12.8 Maximum kw Consumption...1.7 kw Outlet Temperature ( C) 7.2 7.2 7.2 7.2 Flow Rate (l/min) 371 273 182 91 Air Supply Pressure Drop (mtr. H2O) 8.5 5.8 3.4 1.2 Air Pressure (bar)...4.89 Connection Size: (mm) 65 65 65 65 Air Consumption (cfm).....0.34 Condenser Water Unit Dimensions* Inlet Temperature ( C) 29 29 29 29 Width (mm)...2032 Outlet Temperature ( C) 35 35 35 35 Length (mm)........4826 Flow Rate (l/min) 1120 821 549 273 Height (mm).. 2388 Pressure Drop (mtr. H2O) 11.9 7.9 4.6 1.8 *with cabinets mounted on the side as shown Connection Size: (mm) 100 80 65 65 Weight Empty (kg). 7250 Hot Water Operating (kg)....8165 Inlet Temperature ( C) 90.6 90.6 90.6 90.6 Outlet Temperature ( C) 84 84 84 84 Refrigerant type Water (H2O) Flow Rate (l/min) 621 454 303 151 Pressure Drop (mtr. H2O) 4.3 2.7 1.8 0.6 Operating Range Connection Size: (mm) 80 65 65 65 Chilled Water ( C)....3 to 20 Hot Water ( C). 52 to 93 *Rated for maximum capacity mode. Higher efficiencies are Condenser Water ( C).. 10 to 39 available at reduced capacities. Maximum Pressure (bar). 4.82 *All data is preliminary and subject to change without notice. *Maximum pressure 4.82 for hot, chilled,& condenser water Page 1 of 3

DIMENSIONAL DATA & DUCT CONNECTION Page 2 of 3

PERFORMANCE CHART FEATURE OVERVIEW Factors Main Benefits Adsorption Chillers Life Expectancy Greater than 20 Years 7 to 9 Years Maintenance Negligible Maintenance Require High Maintenance Regeneration Temperature (Hot Water) Desiccant Used Replacement Requirements (Periodic Maintenance) Down to 50 C (122 F) Special Silica Gel (Inert)-S2 Not Required Absorption Chillers Shuts down at 82 C (180 F), Needs Back-up Heater Lithium Bromide (Highly Corrosive) Heat Exchangers, Boilers, Absorbent Replacement Required Additional Benefits Start up Times 5 to 7 Minutes compared to 15 minutes for absorption Chilled Water output 4 C-13 C (40-55 F) No crystallization, corrosion, hazardous leaks, or chemical disposal issues Vibration or noise & simple and continuous operations Quite High COP (Coefficient of Performance) Versatile operation Can be used for a wide range of Industrial and commercial application. ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3

Technical Data Sheet Bulletin : BAA:D0055 Effective : April. 06, 2015 Supercedes Date : ADSORPTION CHILLER ADC Series D-FRAME FEATURE HIGHLIGHTS * Ultra low electricity consumption * Ease of maintenance * Zero ozone depletion potential * Advanced microprocessor control * No dangerous chemicals * Designed for outdoor installation * Very few moving parts * Wide temperature ranges allowed MODEL D-75 D-60 D-50 Electrical Rated Capacity (Tonnes) 76 61 51 Voltage 415-3-50/60 Frequency 50/60 Hz Chilled Water Operating kw Consumption..0.8 kw Inlet Temperature ( C) 12.8 12.8 12.8 Maximum kw Consumption...1.9 kw Outlet Temperature ( C) 7.2 7.2 7.2 Flow Rate (l/min) 689 553 462 Air Supply Pressure Drop (mtr. H2O) 8.5 6.4 5.2 Air Pressure (bar)...4.89 Connection Size: (mm) 100 100 100 Air Consumption (cfm).....0.34 Condenser Water Unit Dimensions* Inlet Temperature ( C) 29 29 29 Width (mm)...2159 Outlet Temperature ( C) 35 35 35 Length (mm)........5055 Flow Rate (l/min) 2078 1669 1397 Height (mm).. 2921 Pressure Drop (mtr. H2O) 11.9 8.8 7.0 *with cabinets mounted on the side as shown Connection Size: (mm) 125 125 125 Weight Empty (kg). 11793 Hot Water Operating (kg)....13154 Inlet Temperature ( C) 90.6 90.6 90.6 Outlet Temperature ( C) 84 84 84 Refrigerant type Water (H2O) Flow Rate (l/min) 1151 924 772 Pressure Drop (mtr. H2O) 4.3 3.4 2.4 Operating Range Connection Size: (mm) 100 100 100 Chilled Water ( C)....3 to 20 Hot Water ( C). 52 to 93 *Rated for maximum capacity mode. Higher efficiencies are Condenser Water ( C).. 10 to 39 available at reduced capacities. Maximum Pressure (bar). 4.82 *All data is preliminary and subject to change without notice. *Maximum pressure 4.82 for hot, chilled,& condenser water Page 1 of 3

DIMENSIONAL DATA & DUCT CONNECTION Page 2 of 3

PERFORMANCE CHART FEATURE OVERVIEW Factors Main Benefits Adsorption Chillers Life Expectancy Greater than 20 Years 7 to 9 Years Maintenance Negligible Maintenance Require High Maintenance Regeneration Temperature (Hot Water) Desiccant Used Replacement Requirements (Periodic Maintenance) Additional Benefits Down to 50 C (122 F) Special Silica Gel (Inert)-S2 Not Required Absorption Chillers Shuts down at 82 C (180 F), Needs Back-up Heater Lithium Bromide (Highly Corrosive) Heat Exchangers, Boilers, Absorbent Replacement Required Start up Times 5 to 7 Minutes compared to 15 minutes for absorption Chilled Water output 4 C-13 C (40-55 F) No crystallization, corrosion, hazardous leaks, or chemical disposal issues Vibration or noise & simple and continuous operations Quite High COP (Coefficient of Performance) Versatile operation Can be used for a wide range of Industrial and commercial application. ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3

Technical Data Sheet Bulletin : BAA:D0056 Effective : April. 06, 2015 Supercedes Date : ADSORPTION CHILLER ADC Series E-FRAME FEATURE HIGHLIGHTS * Ultra low electricity consumption * Ease of maintenance * Zero ozone depletion potential * Advanced microprocessor control * No dangerous chemicals * Designed for outdoor installation * Very few moving parts * Wide temperature ranges allowed MODEL E-150 E-140 E-120 E-100 Electrical Rated Capacity (Tonnes) 152 142 124 104 Voltage 415-3-50/60 Frequency 50/60 Hz Chilled Water Operating kw Consumption..0.8 kw Inlet Temperature ( C) 12.8 12.8 12.8 12.8 Maximum kw Consumption...1.9 kw Outlet Temperature ( C) 7.2 7.2 7.2 7.2 Flow Rate (l/min) 1382 1291 1128 946 Air Supply Pressure Drop (mtr. H2O) 9.1 8.2 7.0 5.5 Air Pressure (bar)...4.89 Connection Size: (mm) 100 100 100 100 Air Consumption (cfm).....0.34 Condenser Water Unit Dimensions* Inlet Temperature ( C) 29 29 29 29 Width (mm)...2489 Outlet Temperature ( C) 35 35 35 35 Length (mm)........5080 Flow Rate (l/min) 4164 3887 3395 2846 Height (mm).. 2921 Pressure Drop (mtr. H2O) 13.7 12.5 10.7 8.2 *with cabinets mounted on the side as shown Connection Size: (mm) 150 150 150 150 Weight Empty (kg). 14969 Hot Water Operating (kg)....16366 Inlet Temperature ( C) 90.6 90.6 90.6 90.6 Outlet Temperature ( C) 84 84 84 84 Refrigerant type Water (H2O) Flow Rate (l/min) 2301 2150 1877 1575 Pressure Drop (mtr. H2O) 6.7 6.1 5.2 4.0 Operating Range Connection Size: (mm) 100 100 100 100 Chilled Water ( C)....3 to 20 Hot Water ( C). 52 to 93 *Rated for maximum capacity mode. Higher efficiencies are Condenser Water ( C).. 10 to 39 available at reduced capacities. Maximum Pressure (bar). 4.82 *All data is preliminary and subject to change without notice. *Maximum pressure 4.82 for hot, chilled, & Condenser water Page 1 of 3

DIMENSIONAL DATA & DUCT CONNECTION Page 2 of 3

PERFORMANCE CHART FEATURE OVERVIEW Factors Main Benefits Adsorption Chillers Life Expectancy Greater than 20 Years 7 to 9 Years Maintenance Negligible Maintenance Require High Maintenance Regeneration Temperature (Hot Water) Desiccant Used Replacement Requirements (Periodic Maintenance) Down to 50 C (122 F) Special Silica Gel (Inert)-S2 Not Required Absorption Chillers Shuts down at 82 C (180 F), Needs Back-up Heater Lithium Bromide (Highly Corrosive) Heat Exchangers, Boilers, Absorbent Replacement Required Additional Benefits Start up Times 5 to 7 Minutes compared to 15 minutes for absorption Chilled Water output 4 C-13 C (40-55 F) No crystallization, corrosion, hazardous leaks, or chemical disposal issues Vibration or noise & simple and continuous operations Quite High COP (Coefficient of Performance) Versatile operation Can be used for a wide range of Industrial and commercial application. ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3

Technical Data Sheet Bulletin : BAA:D0057 Effective : April. 06, 2015 Supercedes Date : ADSORPTION CHILLER ADC Series -Ext E-FRAME FEATURE HIGHLIGHTS * Ultra low electricity consumption * Ease of maintenance * Zero ozone depletion potential * Advanced microprocessor control * No dangerous chemicals * Designed for outdoor installation * Very few moving parts * Wide temperature ranges allowed MODEL E-190 Electrical Rated Capacity (Tonnes) 190 Voltage 415-3-50/60 Frequency 50/60 Hz Chilled Water Operating kw Consumption..0.8 kw Inlet Temperature ( C) 12.8 Maximum kw Consumption...1.9 kw Outlet Temperature ( C) 7.2 Flow Rate (l/min) 1726 Air Supply Pressure Drop (mtr. H2O) 10.7 Air Pressure (bar)...4.89 Connection Size: (mm) 100 Air Consumption (cfm).....0.34 Condenser Water Unit Dimensions* Inlet Temperature ( C) 29 Width (mm)...2489 Outlet Temperature ( C) 35 Length (mm)........5080 Flow Rate (l/min) 5201 Height (mm).. 3251 Pressure Drop (mtr. H2O) 13.7 *with cabinets mounted on the side as shown Connection Size: (mm) 150 Weight Empty (kg). 18144 Hot Water Operating (kg)....19958 Inlet Temperature ( C) 90.6 Outlet Temperature ( C) Flow Rate (l/min) Pressure Drop (mtr.h2o) 84 2877 9.1 Refrigerant type Water (H2O) Operating Range Connection Size: (mm) 100 Chilled Water ( C)....3 to 20 Hot Water ( C). 52 to 93 *Rated for maximum capacity mode. Higher efficiencies are Condenser Water ( C).. 10 to 39 available at reduced capacities. Maximum Pressure (bar). 4.82 *All data is preliminary and subject to change without notice. *Maximum pressure 4.82 for hot, chilled, & condenser water Page 1 of 3

DIMENSIONAL DATA & DUCT CONNECTION ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 2 of 3

PERFORMANCE CHART FEATURE OVERVIEW Factors Life Expectancy Greater than 20 Years 7 to 9 Years Maintenance Negligible Maintenance Require High Maintenance Regeneration Temperature (Hot Water) Desiccant Used Replacement Requirements (Periodic Maintenance) Adsorption Chillers Down to 50 C (122 F) Special Silica Gel (Inert)-S2 Not Required Absorption Chillers Shuts down at 82 C (180 F), Needs Back-up Heater Lithium Bromide (Highly Corrosive) Heat Exchangers, Boilers, Absorbent Replacement Required Additional Benefits Start up Times 5 to 7 Minutes compared to 15 minutes for absorption Chilled Water output 4 C-13 C (40-55 F) No crystallization, corrosion, hazardous leaks, or chemical disposal issues Vibration or noise & simple and continuous operations Quite High COP (Coefficient of Performance) Versatile operation Can be used for a wide range of Industrial and commercial application. ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3

Technical Data Sheet Bulletin : BAA:D0058 Effective : April. 06, 2015 Supercedes Date : ADSORPTION CHILLER ADC Series F-FRAME FEATURE HIGHLIGHTS * Ultra low electricity consumption * Ease of maintenance * Zero ozone depletion potential * Advanced microprocessor control * No dangerous chemicals * Designed for outdoor installation * Very few moving parts * Wide temperature ranges allowed MODEL F-330 F-300 F-250 F-200 Electrical Rated Capacity (Tonnes) 335 305 254 203 Voltage 415-3-50/60 Frequency 50/60 Hz Chilled Water Operating kw Consumption..1.3 kw Inlet Temperature ( C) 12.8 12.8 12.8 12.8 Maximum kw Consumption...2.4 kw Outlet Temperature ( C) 7.2 7.2 7.2 7.2 Flow Rate (l/min) 3043 2771 2309 1843 Air Supply Pressure Drop (mtr. H2O) 8.8 7.9 6.1 4.6 Air Pressure (bar)...4.89 Connection Size: (mm) 200 200 200 200 Air Consumption (cfm).....0.34 Condenser Water Unit Dimensions* Inlet Temperature ( C) 29 29 29 29 Width (mm)...3658 Outlet Temperature ( C) 35 35 35 35 Length (mm)........5334 Flow Rate (l/min) 9167 8346 6949 5556 Height (mm).. 3505 Pressure Drop (mtr. H2O) 12.8 11.3 8.8 6.7 *with cabinets mounted on the side as shown Connection Size: (mm) 250 250 250 250 Weight Empty (kg). 21319 Hot Water Operating (kg)....24040 Inlet Temperature ( C) 90.6 90.6 90.6 90.6 Outlet Temperature ( C) 84 84 84 84 Refrigerant type Water (H2O) Flow Rate (l/min) 5072 4618 3846 3073 Pressure Drop (mtr. H2O) 6.1 5.5 4.3 3.0 Operating Range Connection Size: (mm) 200 200 200 200 Chilled Water ( C)....3 to 20 Hot Water ( C). 52 to 93 *Rated for maximum capacity mode. Higher efficiencies are Condenser Water ( C).. 10 to 39 available at reduced capacities. Maximum Pressure (bar). 4.82 *All data is preliminary and subject to change without notice. *Maximum pressure 4.82 for hot, chilled, & Condenser water Page 1 of 3

DIMENSIONAL DATA & DUCT CONNECTION Page 2 of 3

PERFORMANCE CHART FEATURE OVERVIEW Factors Main Benefits Adsorption Chillers Life Expectancy Greater than 20 Years 7 to 9 Years Maintenance Negligible Maintenance Require High Maintenance Regeneration Temperature (Hot Water) Desiccant Used Replacement Requirements (Periodic Maintenance) Down to 50 C (122 F) Special Silica Gel (Inert)-S2 Not Required Absorption Chillers Shuts down at 82 C (180 F), Needs Back-up Heater Lithium Bromide (Highly Corrosive) Heat Exchangers, Boilers, Absorbent Replacement Required Additional Benefits Start up Times 5 to 7 Minutes compared to 15 minutes for absorption Chilled Water output 4 C-13 C (40-55 F) No crystallization, corrosion, hazardous leaks, or chemical disposal issues Vibration or noise & simple and continuous operations Quite High COP (Coefficient of Performance) Versatile operation Can be used for a wide range of Industrial and commercial application. ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3