Adsorption refrigeration system using waste heat

Similar documents
Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Review of Experimental Evaluation of Adsorption Cooling System Powered By Exhaust Heat of an Automobile

COMPACT ADSORPTION CHILLERS WITH COATED ADSORBER HEAT EXCHANGERS

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

EFFICIENT ADSORPTION REFRIGERATORS INTEGRATED WITH HEAT PIPES

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Efficient adsorption refrigerators integrated with heat pipes

Performance investigation of Air-conditioning system using ejector as expansion device

INSTITUTE FOR ENVIRONMENTAL RESEARCH & SUSTAINABLE DEVELOPMENT NATIONAL OBSERVATORY OF ATHENS (NOA)

Fabrication of Hot and Cold Water Dispenser

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Effect of Exhaust Gas Temperature on the Performance of Automobile Adsorption Air-Conditioner

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Design & Fabrication of Hybrid Cooler

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

SOLAR COOLING TECHNOLOGIES

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Design of LPG Refrigeration System

K.F. Fong *, C.K. Lee, T.T. Chow

Enhancement of COP using Nanoadditives in Domestic Refrigerator

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

Adsorption Refrigeration System for Cabin Cooling of Trucks

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Adsorption Chillers Energysmart Green Cooling

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Enhancement of COP in Vapour Compression Refrigeration System

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Performance Study of Triple Concentric Pipe Heat Exchanger

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

SOLAR THERMAL COOLING TECHNOLOGIES

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

PRODUCING COOLING FROM SOLAR ENERGY BY USING ADSORPTION CYCLE WITH ACTIVATED CARBON AND METHANOL PAIR

Numerical Simulation of Window Air Conditioner

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

CHAPTER 1 INTRODUCTION

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance Assessment of Water Cooled Condenser Refrigeration System

International Journal of Informative & Futuristic Research ISSN (Online):

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Solar Drying Techniques And Performance Analysis: A Review

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

DEEPAK PALIWAL, S.P.S.RAJPUT

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

System Modeling of Gas Engine Driven Heat Pump

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

EXPERIMENTAL INVESTIGATION OF THE AIR CLEANING EFFECT OF A DESICCANT DEHUMIDIFIER ON PERCEIVED AIR QUALITY

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

REFRIGERATION AND AIR CONDITIONING

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

A Comparison Between Refrigerants Used In Air Conditioning

II. OBJECTIVE OF RESEARCH

PERFORMANCE OF REFRIGERATOR USING R-600A AS REFRIGERANT

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Performance of an Improved Household Refrigerator/Freezer

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

Performance Analysis of Domestic Refrigeration System with Thermoelectric Module

Recent Advances in Energy, Environment and Economic Development

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Transcription:

Adsorption refrigeration system using waste heat 1 RISHI SREEKUMAR, 2 SANJEEV SINGH, 3 HIMANSHU SHEKHAR, 4 RAUSHAN KUMAR, 5 Dr. R. S. BINDU 1,2,3,4 BE Students, 5 Professor Mechanical Engineering Department DIT, Pimpri, Pune-18 Abstract: Adsorption refrigeration systems that work on waste heat have extensive refrigeration and air conditioning applications in water chillers, automobile air conditioning systems, and ice making. The adsorption heat exchangers can replace compressors as they can be used for compressing the refrigerant at constant volume. There is a huge amount of heat exhausted from engines, boilers, various power plant furnaces etc. Generally this exhaust heat is let into the atmosphere as waste heat. Hence, there is a huge need for waste heat energy recovery system. The main drawback of the adsorption refrigeration system is its low thermal conductivity. Hence, the main scope of this project is to improve the design of adsorber bed to increase its thermal conductivity. This is done by introducing spherical metal balls of small diameters equivalent adsorber thickness, into the adsorber bed. Activated carbon and R134a pair is considered for the project. In this project mathematical investigation is carried out and experimental setup has been manufactured to evaluate overall thermal conductivity of adsorption heat exchanger system. Index Terms: Adsorber Bed, Adsorption, Desorption, Extended surfaces, Granular Activated Carbon, Specific Cooling Power. I. INTRODUCTION Various adsorption heat exchanger systems are available in the market based on the type of adsorber, refrigerant material, heat exchanger material used. Aim of project The aim of the project is to increase the thermal conductivity by making changes in the adsorber bed design. Need of project The low thermal conductivity of adsorption heat exchangers have limited them from being used commercially. Hence, there is a need for improvement in design. II. PROBLEM STATEMENT Performance of adsorber bed is dependent on its design. There are many methods to improve the heat transfer performance like using different nanofluids for bed. The materials of the heat exchanger components can also be varied to increase conductivity. Increasing effective surface area of adsorber bed to increase the heat transfer rate between the exhaust gas (waste heat) and the adsorbent particles, reducing cycle time by increasing adsorbate diffusion rate within the adsorbent particles during the adsorption/desorption processes can improve the performance of adsorber bed. New adsorber bed has to be design and should be compared with commonly used design. Here extended surface areas are provided on adsorber beds to improve the heat transfer. These extended surfaces are in the form of metal balls within the activated carbon adsorber bed. Investigation of the performance of adsorber bed with extended surface areas needs to be done and should be compared with the adsorber bed without extended surface areas. III. LITERATURE REVIEW In ASHRAE Journal (2011), Kai Wang et al. [1] explained Basic adsorption refrigeration cycle. Different working pairs for adsorption refrigeration system are studied for their adsorption properties based on temperature and heat of adsorption. Also classification of pairs based on applications like ice-making chilled water and air conditioning is studied. Wang and Oliveira (2006) [2] studied adsorption refrigeration as a mean of waste heat recovery and solar energy. The applications included are ice making and air conditioning. It includes not only cooling and heating, but also dehumidification by desiccant systems. The prototypes presented were designed to use waste heat or solar energy as the main heat source. The solid sorption systems still present some drawbacks such as low specific cooling power (SCP) and coefficient of performance (COP). Thus, some techniques to overcome these problems are also contemplated, together with the perspectives for their broad commercialisation. Among these techniques, a special attention was devoted to innovative adsorbent materials, to advanced cycles and to heat pipes, which are suitable devices not only to improve the heat transfer but also can help to avoid corrosion in the adsorbers. Zhang and Wang (1997) [3] performed numerical study on dynamic performance of an adsorption cooling system for automobile heat recovery. The effects of various operating temperature and overall heat transfer coefficient on system IJRTI1706024 International Journal for Research Trends and Innovation (www.ijrti.org) 116

performance are studied. It is found that improving the overall heat transfer coefficient is most effective way to obtain increased SCP. T. X. Li et al. (2014) [4] discussed the progress in the development of solid-gas sorption refrigeration thermodynamic cycles like heat recovery sorption cycle, mass recovery sorption cycle, mass and heat recovery sorption cycle, double/multi-effect sorption cycle, combined double-way sorption cycle, double-effect and double-way sorption cycle, two/ multi-stage sorption cycle, etc. The results from experimental works showed that the advanced sorption cycle can produce two useful cooling-effects at the expense of only one high-temperature heat input during one cycle. IV. CONCEPT OF ADSORPTION AND DESORPTION Adsorption is the general phenomenon based on a physical or chemical reaction process, resulting from the interaction between a solid (adsorbent) and a gas/liquid (refrigerant). Physical adsorption, is caused by the Van der Waals forces. It is an exothermic process due to the gas liquid phase change. The energy liberated depends on the nature of the adsorbent adsorbate pair and is called the isosteric heat of adso. The atoms, molecules or ions in a liquid are diffused to the surface of a solid in a liquid phase adsorption. They are bonded with the solid surface or are held by weak intermolecular forces. In heating the adsorber bed, more is the temperature of the bed, better is desorption. As the temperature increases, after gaining sufficient energy, the bond between adsorbent and adsorbate gets broken. Similarly, to get maximum amount of adsorbate quantity adsorbed, temperature should be as low as possible. This gives rise to need for effective heating and cooling of adsorber bed. A basic adsorption cycle consists of four steps : heating and pressurization, desorption and condensation, cooling and depressurization, and adsorption and evaporation. In the first step, the adsorber bed is heated by any low grade thermal energy source. The pressure of the adsorber bed increases from the evaporating pressure up to the condensing pressure while the adsorber bed temperature increases. This step is equivalent to the compression in the vapour-compression cycle. In the second step, the adsorber bed continues receiving heat and its temperature keeps increasing, which results in desorption (or generation) of refrigerant vapour from adsorbent in the adsorber bed. This desorbed vapour is liquefied in the condenser and the condensing heat is released to the heat sink. This step is equivalent to condensation in the vapour-compression cycle. At the beginning of the third step, the adsorber bed is disconnected from the condenser. Then, it is cooled by heat transfer fluid at the second heat sink. The pressure of the adsorber bed decreases from the condensing pressure down to the evaporating pressure due to the decrease in the adsorber bed temperature. Refrigerant vapours et expanded in thermostatic expansion valve and enters in evaporator. This step is equivalent to the expansion in the vapour-compression cycle. In the last step, the adsorber bed keeps releasing heat while being connected to the evaporator. The adsorber bed temperature continues decreasing, which results in the adsorption of refrigerant vapour from the evaporator by adsorbent, producing the desired refrigeration effect. This step is equivalent to the evaporation in the vapour-compression cycle. The basic adsorption refrigeration cycle is an intermittent system and the cooling output is not continuous. A minimum of two adsorbers beds are required to obtain a continuous cooling effect (when the first adsorber bed is in the adsorption phase, the second adsorber bed is in desorption phase). These adsorber beds will sequentially execute the adsorption-desorption process. V. COMPONENTS OF ADSORPTION REFRIGERATION IN AUTOMOBILE AIR CONDITIONING Adsorber bed The adsorber bed replaces the compressor in a conventional vapour compression refrigeration system with heat exchanger. Hence, the adsorber bed is the part which separates the adsorption refrigeration system with the commonly used vapour compression refrigeration cycle system. Adsorbent Granular activated carbon- charcoal is used as a refrigerant. It has granule size of 1.5mm. Since it has very small granule size, filters (strainers) are fixed at inlet and outlet of adsorber beds so that only gas will flow. Granules will not flow inside other parts of the system. Adsorbate R134a (1-1-1-2 tetrafluroethane) is used as adsorbate. It is non-flammable, non-toxic in nature. It has zero ODP. R134a is widely used in different refrigeration and air-conditioning applications. Heat Gun (Hot Air Gun) In actual applications adsorption refrigeration system is run on low grade thermal energy source like exhaust gases. It is difficult to control temperature and flow of exhaust gases coming out from internal combustion engines. So for testing purpose, hot air coming from heat gun is used instead of exhaust gases. Condenser Function of Condenser in adsorption refrigeration is same as that of the one used in vapour compression refrigeration IJRTI1706024 International Journal for Research Trends and Innovation (www.ijrti.org) 117

system. It converts gaseous high pressure refrigerant to high pressure. In current experimental setup air cooled condenser is used. Heat is rejected due to forced convection to the air flowing over condenser. Thermostatic Expansion Valve (TXV) Throttling also called as isenthalpic expansion process is done at TXV. TXVs are precision devices designed to regulate refrigerant liquid flow into the evaporator in exact proportion to evaporation of refrigerant liquid in the evaporator. It is constant superheat type TXV. Refrigerant gas leaving the evaporator can be regulated since the TXV responds to the temperature of the refrigerant gas leaving the evaporator and the pressure in the evaporator. Evaporator Cooling effect is obtained at this part of the experimental set up. Vacuum pump R134a refrigerant is used as an adsorbate in the system. Before charging the R134a inside the system vacuum must be created. Vacuum pump is used to create such vacuum. Yellow pipe connected to middle port of manifold gauge is connected to suction port of vacuum pump. Water Pump Water flow is essential for cooling of bed and better adsorption. Water pump is used to circulate water in the system. Flow divider is used to divide and distribute the water flow in all the water pipes properly. Spherical metal balls They are used to increase the thermal conductivity of the heat exchanger. This is done by introducing them into the adsorber bed. The diameter of the metal balls is less than the thickness of the adsorber granular material thickness. The material of balls should be of higher conductivity and should be resistant to corrosion. VI. Adsorber Bed Design Total two designs of adsorber beds are used in testing. One design is bed without Spherical metal balls (bed 1) and other is the bed with Spherical metal balls (bed 2). Hot air pipe is concentric with cylindrical bed body. Ten pipes are provided for cooling of bed by water as shown in fig. Rest of the volume is filled with activated carbon in bed 1. Detailed specification of bed is given in Table below. In this design, only outer surface of hot air pipe is available for heating of bed. Only activated carbon is filled in the space in between the pipes in bed design without metal balls, bed 1. In the bed design with metal balls i.e. bed 2 the activated carbon along with metal balls having good conductivity like mild steel are used. Front view cut section of adsorber bed IJRTI1706024 International Journal for Research Trends and Innovation (www.ijrti.org) 118

Side view cut section of adsorber bed Adsorber bed dimensions Dimensions 32 mm 125 mm 12 mm 940 mm 15.5mm 8 mm 1.5 mm 2 mm Adsorber Bed Parameter Hot Fluid Pipe Dia: Outer Stainless Steel Casing Dia: Water Tube Dia: Adsorber Bed Length: Coolant Tube Dia: Refrigerant Tube Dia: Mild steel metal ball diameter Activated carbon granules thickness VII. Conclusion Maximum bed pressure is increased to some extent for adsorber bed with Spherical metal balls i.e. Bed 2. This is due to enhanced heat transfer rate by metal balls. Higher heat transfer rate increases bed temperature and correspondingly bed pressure is also increased. Adsorber bed temperature for adsorber bed 2 is more than bed 1, hence desorption capacity of bed 2 is better than bed 1 for same cycle time, source temperature and airflow rate. For the same size of adsorber beds if metal balls are introduced in the adsorber bed then quantity of refrigerant adsorbed decreases due to less volume of adsorbent. Due to increased thermal conductivity the cycle time is reduced in bed 2 as compared to bed 1. This coupled with increase in the number of adsorbers in the system will make the system more efficient and continuous. SCP (specific cooling power) of system increases when higher desorption is obtained. As hot air flow rate and temperature increases, heat supplied increases in bed 2. Hence, better desorption and higher SCP values are obtained. VIII. Future Scope Cycle time can be reduced by implementing multiple adsober bed in system. This will make system continuous and more efficient. Performance of adsorber bed can be enhanced by improving the design. Simulation study of adsorber bed can be done. No standard model is available to simulate adsorption and desorption process. For simulation study user defined functions need to be created. IJRTI1706024 International Journal for Research Trends and Innovation (www.ijrti.org) 119

References [1] Kai Wang, Edward A. Vineyard, New opportunities for Solar Adsorption Refrigeration, ASHRAE Journal, 2011, pp 14-24 [2] R. Z. Wang, R. G. Oliveira, Adsorption refrigeration-an efficient way to make good use of waste heat and solar energy, Progress in Energy and Combustion Sciences 32, 2006, pp 426-458 [3] T. F. Qu, R. Z. Wang, W. Wang, Study on heat and mass recovery in adsorption refrigeration cycles, Applied Thermal Engineering 21, 2001,pp 439-452 [4] Li Zhi Zang, Ling Wang, Performance estimation of an adsorption cooling system for automobile waste heat recovery, Applied Thermal Engineering Vol. 17 No. 12, 1997, pp 1127-1139 IJRTI1706024 International Journal for Research Trends and Innovation (www.ijrti.org) 120