Equipment specifications (D6)

Similar documents
16S-Series 150W. In Vivo SPF Sunscreen Testing Solar Simulator

Digital Sensors Erythema Sensor PMA2101

Development of a variable output LED-365 irradiance standard

Version: 1603 UV Accelerated Weathering Testers Weice Testing Instrument Co., Limited

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

IWASAKI ELECTRIC CO., LTD

Ci5000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

TECHNICAL SPECIFICATION

UV Weather Resistance Test Chambers

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

INTERNATIONAL STANDARD

CTS Your Partner for Customised Technical Solutions

Ci4000. Weather-Ometer. Accelerating Your Expertise. Setting the Standard for Xenon Weathering

INTERNATIONAL STANDARD

Model KBWF 240 Growth chambers with light and humidity

UV Weather Resistance Test Chamber Technical Data

IEC PROJETOS EM VOTAÇÃO. IEC 62256/Ed2: Hydraulic turbines, storage pumps and pump-turbines - Rehabilitation and performance improvement.

Model KBWF 720 Growth chambers with light and humidity

UV measurements for medical applications using SiC photodiodes

Update on the new IEC standards and their impact on quality of PV modules

Development and setting up a calibration facility for UV sensors at high irradiance rates

TECHNICAL REPORT. Solar Energy - Field Pyranometers - Recommended practice for use

Optics & Radiometry Laboratory

o Clear instruction for operation o Measurement and control of o Stationary sensor for o Programming capabilities of o Countdown timer selectable

USER MANUAL MODEL UV MINDER 3D V2.0. Part Number: Revision Level: A

IAS Accreditation Number UL International Germany GmbH Address Admiral Rosendahl Strasse 23 Neu Isenburg Germany

CALIBRATION HOW IT WORKS

ADVANCED. Environmental Chambers

Laser Analyzers for NH3 Safety Monitoring and Leak Detection

The Growing Viability of UV LED for Wide Web Coating Applications. Tuesday, October 11, 2016

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

WASTEWATER Online UV%Transmission Analyzer

CALIBRATION HOW IT WORKS

Fitoclima Pharma. Stability and Photostability Chambers for the pharmaceutical industry

Benefit from our experience and competence Application-focused solutions from UV to IR

Specifications Wavelength Range: 190 nm to 800 nm continuous

TECHNICAL SPECIFICATION

Efficient Lighting MVE Infrastructure Status Report and Overview. Steve Coyne. Consultant, UNEP en.lighten

Publication American Institute of Physics. Reprinted with permission.

Construction of a Calibration System for Power Responsivity of Optical detectors Using Different Laser Sources

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

PHOTOVOLTAIC DEVICES -- PART 2:

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

FITOCLIMA 600 & 1200 PHARMA

VDE-QT-PV001:2012/01

Technical Information OUSAF44

FITOCLIMA 600 & 1200 STABILITY

Recommended Work Area Controls

CALIBRATION HOW IT WORKS

UVC/T-AR UVC/T-M-AR UVT-S-AR

FITOCLIMA 600 & 1200 STABILITY

Understanding total measurement uncertainty in power meters and detectors

Annexure-I. 1. Goniophotometer and Goniospectroradiometric measurement System

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

SVENSK STANDARD SS-EN ISO :2006. Plast Metoder för exponering i artificiellt ljus Del 2: Xenon-arc ljuskällor (ISO :2006)

for Drinking Water Systems

INTERNATIONAL STANDARD

Instruments Designed for POF & Fibre Optic Cable Testing

FitoClima / FitoTerm SOL chambers

Type approval qualification of Photovoltaic Modules Procedures and test experiences

UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

An FT-NIR Primer. NR800-A-006

UVC/T-M-AR stainless steel UV cabinet

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

Efficient curing processes with innovative UV-LED technology The Heraeus Noblelight UV-LED portfolio

High Lux Performance White LED MR16 Lamp

SUNSTAR 传感与控制 TEL: FAX: DATASHEET Lightingg Solutions 1100 Series High Stabi

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

BiliCare INTENSIVE PHOTOTHERAPY

UVC/T-AR UVC/T-M-AR UVT-S-AR

BRIEFING OF U-CAN : Honesty Innovation Sharing - CHOOSE U-CAN ; MAKE YOU CAN- Certificated manufacturer of ISO and CE Conformity.

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

NanoReady. Micro UV-Vis Spectrophotometer

Inline measuring of UV LED & conventional UV lamps

Optical Measurement Techniques for LED Clusters and LED Safety

UV LED Measurement Status Update

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

HPLC Column Ovens and Temperature Controllers

Source Test and Characterization Program

Flame Simulator User Manual. Publication Rev. A

Lighting in the workplace is it just about vision?

Mechanism of audible sound generation during flash lamp operation. Tetsuya Kitagawa, Mitsuru Ikeuchi, Yukihiro Morimoto, Fumihiko Oda

PQS performance specification

PHOTOSTABILITY CHAMBERS

UV I UNIT030W / UV I UNIT055W

Page 2 of 14 Report Ref. No

Ultraviolet Air Disinfection Equipment

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

shaker LT-X (Lab-Therm) Space saving stackable incubator shaker

MADE FOR THE TRADE! FIBER OPTIC. professional. XL fibertools Series. instruments

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Flame detector. Building Technologies Division Infrastructure & Cities Sector

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

This is a preview - click here to buy the full publication

6 POINTS TO CONSIDER WHEN PURCHASING A CONSTANT CLIMATE CHAMBER IN THE PHARMACEUTICAL INDUSTRY BUYER S GUIDE

LM-80V , h V LM-30V h V

UV CURING SYSTEMS OmniCure UV Curing Lamp & LED Systems TO ORDER, PLEASE CALL

Transcription:

Equipment specifications (D6) This report has been produced for the Cyprus Research Promotion Foundation in fulfilment of deliverable number D6 of the project Advanced Photovoltaics Research and Testing for Improved Technologies, grant number ΑΝΑΒAΘΜΙΣΗ/ΠΑΓΙΟ/0308/21. Contents 1. Introduction 2. Equipment 2.1. Indoor solar simulator flash system 2.2. Photovoltaic cell tester 2.3. Climatic chamber for PV module testing 2.4. Indoor UV solar simulator 1. Introduction D6 is a deliverable of Work Package 3 which aimed at delivering a fully-equipped, state-of-the-art laboratory for the purposes of testing PV devices to the IEC standards 61215, 61646 and 62108 whilst adhering to the requirements of ISO 17025:2005. In D6, we present a report on the set of specifications for the equipment purchases necessary for the infrastructure upgrade at UCY. Attached are all the detailed specifications of the above mentioned equipment. 2. Equipment

Indoor solar simulator flash system Class ABA solar simulator according to IEC 60904-9 Maximum distance to panel: 8 m; max height: 2.5 m Reference cells for c-si provided Calibrated electronic load and cabling for I-V measurement of modules with peak power output > 500 W Maximum height of flash unit: 3 m Illuminated area 2 m by 2 m minimum Non-uniformity of irradiance 2% Short term instability of irradiance 0.5% Long term instability of irradiance 2% Spectral match to AM1.5 global irradiance between 0.75 and 1.25 for intervals specified in IEC 60904-9 Module holder provided Data processing unit for connection to load Intensity of illumination up to 1 kwm -2 at module 230 V ac power operation

Photovoltaic cell tester Minimum illuminated area: 150 mm x 150 mm Temperature control at cell AM 1.5 spectrum Intensity over illuminated area: 1000 Wm -2 4-wire contact points NIST or other certification centre traceable lamp Vacuum chuck for holding cell Class A spectrum as defined in IEC 60904-9 Class A uniformity as defined in IEC 60904-9 Computer controlled electronic load over 12 W

Indoor UV solar simulator Enclosed UV chamber for indoor use Temperature control, to maintain module at 60 C ± 5 C whilst under illumination Integrated instrumentation for measuring UV radiation in the anges 280-320 nm and 320-400 nm with an uncertainty of ± 15%. UV radiation source to provide up to 250 Wm -2 in the plane of the module in the wavelength range of 280-400 nm UV irradiance uniformity of ± 15% over the module Illuminated area 2 m by 2 m minimum No appreciable irradiance at wavelengths below 280 nm Integrated, adjustable resistive load for connection to module Suitable for testing to standards IEC 61646 and IEC 61215 Integrated module mounting

Climatic chamber for PV module testing Programmable temperature and humidity cycles Mounting facilities to allow free circulation of air Temperature accuracy within ± 2 C Temperature range - 40 to +110 C Heating and cooling temperature ramp rate: >2.5 C/min between - 40 and +110 C Humidity control Relative humidity levels ±5% accuracy Capable of minimum 85% humidity levels Minimum internal dimensions 2 m (l) x 2 m (w) x 2 m (h) Option for integrated Class A solar simulator Walk-in option Appropriate for thermal cycling tests, humidty-freeze tests, and damp heat tests as outlined in IEC 61215 and IEC 61646 Minimum 5 year guarantee Installation and training Network-ready for remote monitoring/control Access for additional power/sensor wires Interior lighting Internal safety door release Capacity minimum 10 modules @ 30 kg each Integrated support racks for modules Three-phase voltage 400V