OH110, OP110, HI110 Automatic fire detectors

Similar documents
OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

OOH740, OOHC740 Automatic fire detectors

OH720, OP720, HI720, HI722

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT221, FDO221, FDT221

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multisensor fire detector

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT241-A9-Ex Multisensor fire detector

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

DT1101A / DT1102A / DO110xA Automatic fire detectors

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Fire & Security Products. Siemens Building Technologies Group

Cerberus FIT conventional system

ASA linear smoke detector

Smoke Detector Testing

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

System 800 Addressable Fire Detection & Alarm System

DF1101-Ex Infrared flame detector

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Consultant Specification AGILE Wireless Fire Detection System

DF1151-Ex Infrared flame detector

Series 65 Product Guide MAN 3036

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Evolution Analogue Addressable Fire System

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Intelligent addressable fire alarm control panel

ALK-V PHOTOELECTRIC SMOKE SENSOR

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Intelligent Detection Devices

optical detector multisensor detector heat detector mounting bases product guide

FDCIO223 (ES 45) Transponder

Installation and Operation Manual

FC723 Fire control panel

Conventional Smoke Detectors KFAPO

Emergi-Lite Orbis detectors

Open-area Smoke Imaging Detection (OSID)

FD20 Sinteso Detector system

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

FC724 Fire control panel

Quick Selection Guide Fire Systems LSN Periphery

FC724 Fire control panel

FC722 Fire control panel

FCP 320/FCH 320 Conventional Automatic Fire Detectors

FDCL221-M Multi line separator module

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

850 and 830 Series. Fire Detectors - Generation 6

830 Series. Fire Detectors - Generation 6

MULTISENSOR SMOKE AND HEAT DETECTOR DMP-100 OPTICAL SMOKE DETECTOR DRP-100 FIXED TEMPERATURE / RATE-OF-RISE HEAT DETECTOR DCP-100

Analogue addressable devices

MR300 OPTICAL SMOKE DETECTOR RANGE PRODUCT APPLICATION & DESIGN INFORMATION

Building Technologies

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Synova TM product catalog.

Model OOHC941 ARCHITECT AND ENGINEER SPECIFICATIONS Advanced multi-criteria fire detector that has optical, thermal and CO sensors

ARCHITECT AND ENGINEER SPECIFICATIONS

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

850 Series Fire Detectors - Generation 6

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Polycarbonate External Sounder & Strobe Unit

Fire control panels FC726 FC726-XA

Input module, input/output module

SERIES 65 ENGINEERING PRODUCT GUIDE

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

XC10 combined fire detection and extinguishing control

Input module, input/output modules

Orbis IS Product Guide MAN 3041

Standard detectors. General information. Product Sheet Detec on

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

FDBZ290 Air sampling smoke detection kit Technical Manual

Fire protection for emergency power supply

FDL241-9 Linear smoke detector Mounting Commissioning

Desigo Fire Safety intelligent detectors for complete safety

Multi line separator module

FC2020 Fire control panel

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

850 and 830 Series. Generation 6

XP95 ENGINEERING PRODUCT GUIDE

Solution F2. Fire Alarm Control Panels one step ahead.

Radio fire detection system

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

>WIRELESS> ALARM SYSTEM CR200

FAP-420/FAH-420 Automatic Fire Detectors LSN improved version

MINERVA MZX125 Digital Addressable Fire Detection System

XC10 combined fire detection and extinguishing control

Conventional Fire Detection

850 and 830 Series. Generation 6

LaserFOCUS VLF-250 Engineering Specification

Cerberus ECO. Fire Safety Products and Accessories. Product Catalogue. siemens.com/buildingtechnologies

The new detector from Rafiki

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

MINERVA MZX125. Digital Addressable Fire Detection System

DM1131 / DM1133 / DM1134 Manual call points

Transcription:

OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation Internal fault monitoring Fault indication Building Technologies

Characteristics Environmental ecologically processing recyclable materials electronic and synthetic material simply separable Characteristics resistant to environment and interference factors such as dust, fibers, insects, humidity, extreme temperatures, electro-magnetic interference, corrosive vapors, vibration insensitive to impact, tamper protection protected electronics, high-quality components built-in alarm indicator (AI), visible at 360 up to 2 external alarm indicators of type FDAI91/FDAI92 connectable per detector signal processing with detection algorithms the same detector base type can be used for each detector type, for surface and recess supply wiring 2

OH110 Multi-sensor smoke detector OP110 Optical smoke detector Multi-sensor smoke detector consist of: Detector Dust cap to cover the detector for protection against dust during construction work Works according to the scattered light principle with one sensor, optical forward scattering Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles an additional heat sensor increases the fire detector s immunity to deceptive phenomena immunity against transient false alarm causes for the detection of flaming fires caused by the combustion of liquid and solid matters, as well as smoldering fires for reliable fire detection in environments with deceptive phenomena Optical smoke detector consist of: Detector Dust cap to cover the detector for protection against dust during construction work Works according to the scattered light principle with one sensor, optical forward scattering Opto-electronic sampling chamber holds off disturbing extraneous light but optimally detects smoke particles for the detection of smoke-generating flaming and smoldering fires HI110 Heat detector (RoR) Heat detector consist of: Detector Equipped with one heat sensor For high requirements Certain response behavior with slow and fast temperature increases, also by depth temperature Parameter set: A1R For areas having high levels of dust, dirt or moisture that may lead to false activating with smoke detectors 3

Detector base DB110 Standard conventional detector base for all series 110 point detectors Selects parameter set 1 within detectors for recess supply wiring for surface supply wiring, cable diameter up to 8 mm Base attachment BA720 For the supply of surface-mounted tubes (max. 20 mm) and trunking (max. 25 mm x 15 mm) The detector is fixed with a spring-loaded catch. 4

5 Installation Simple installation Universal base with 2 break outs on the side for surface supply wiring at max. Ø8 mm extra large rear opening for easy recess supply wiring extra-large mounting slots facilitate a re-use of existing drill holes resulting from other systems connecting terminals for cable diameter at 2.5 mm 2 place for auxiliary terminals Place for auxiliary terminals Connecting terminals detector line and ext. AI Opening for cable entry AI 6 1a 1b Connecting terminals detector line and ext. AI Mounting slots min. 40 mm up to max. 90 mm alarm indicator (AI) centered in the detector; no alignment required 5

Dimensions of detector with base OH110 OP110 HI110 Technical data OH110 OP110 HI110 Operating voltage DC 16 28 V DC 16 28 V DC 16 28 V Operating current (quiescent) Max. 100µA Max. 100µA Max. 100µA Ext. alarm indicator without sounder base AI connectable 2 2 2 Operating temperature -10 +50 C -10 +55 C -10 +50 C Storage temperature -30 +70 C -30 +70 C -30 +70 C Humidity (short-term moisture condensation permitted) 96 % rel. 96 % rel. 96 % rel. Communication protocol Collective/conventional Collective/conventional Collective/conventional Color white, ~RAL 9010 white, ~RAL 9010 white, ~RAL 9010 Protection category EN60529 / IEC529 with detector base seal RS720 IP40 IP42 Standards CEA4021, EN 54-7 EN 54-7 EN 54-5 Approvals VdS LPCB G212059 request IP40 IP42 G212033 request QS standards Siemens Standard SN 36350 IP40 IP42 G212004 request OH110 OP110 HI110 6

Details for ordering Type Part no Designation Weight OH110 S54372-F11-A1 Multi sensor fire detector (collective) 0.144 kg OP110 S54372-F4-A1 Optical smoke detector (collective) 0.138 kg HI110 S54372-F9-A1 Heat detector (collective, differential) 0.130 kg DB110 S54372-F5-A1 Detector base (collective) 0.052 kg FDAI91 S54370-F9-A1 Alarm indicator, door frame version 0.020 kg FDAI92 S54370-F3-A1 Alarm indicator, surface version 0.050 kg BA720 S54319-F20-A1 Base attachment 0.100 kg 7