Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Similar documents
Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

555 Hotplate 565 Magnetic Stirrer 575 Hotplate-Stirrer

INSTRUCTION MANUAL. stirring hotplate. VMS-C7 advanced series. Brand :

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Professional Series. Instruction Manual Hotplates, Stirrers, Hotplate-Stirrers

StableTemp Hotplates, Stirrers and Stirring Hotplates

Thermo-Sealer. Manual Heat Sealer. User Manual

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Operating Instructions

Analog Melting Point Apparatus

High Output Vacuum/Pressure Pump

Boekel Microplate Incubator

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

BD Viper Lysing Heater Manual (for BD Viper System)

CFC-FREE CB-60/CB-80 Cryobath Low Temperature Bath. Thermo NESLAB Manual P/N U00551 Rev. 04/03/00. Instruction and Operation Manual

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

Isotemp Hotplates, Stirrers and Stirring Hotplates

Aluminum Heating Mantles

Owner & Operator s Manual. Table of Contents

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

Electron Microscopy Sciences

MS-H-Pro-T Magnetic Hotplate-Stirrer with Timer

TTT Digital Incubator

HOT PLATE OPERATION MANUAL AND PARTS LIST Series 64

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Reacti-Therm I and III Heating/Stirring Modules

10 Table/Wall Mount Fan Model No: FTY-25 Operating Instructions FTY Soleus Air International

Digital Heat Block User Manual

NESLAB CB 60/CB 80 Cryobaths. Operation. Product Service Information, Applications Notes, MSDS Forms, .

Cimarec Stirring Hot Plates

16 Stand Fan with Remote Control Model No: FS3-40R-30

600W Hand Blender. Model: SP20160 (all colours) Helpline: v1.0. SP20160_IM.indd 1 26/07/ :38

Refrigerated Incubator Model and Operating Instructions

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

ELECTRIC BUNSEN INSTRUCTION BOOK. BA6101, BA6101/C, BA6101x1, BA6101x3. Page 1 of 20 M6877 Issue 9.6

OPERATING INSTRUCTIONS. EchoThermJ ANALOG MULTI-POSITION STIRRERS AND STIRRING HOT PLATES. Document Number HS15-01 Revised May 20, 2011

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Reacti-Therm I and III Heating Modules

FLOOR MACHINE EDGER MINI SCRUBBER MODEL E-1

H-16.5 Record Cleaning Machine Setup and Instruction Manual

Operation Manual Vortex mixer unitexer 1

7 Fin Oil Filled Radiator

THE MW-1 Cyclone RECORD CLEANING MACHINE

Pasto Sous vide water bath

StableTemp Digital Hotplates, Stirrers and Stirring Hotplates

Operator s Manual. IP-100 Immersion Probe Cooler

Parts and Instruction Manual ET Extraction Tool

PROCESSING UNIT II V Hz V Hz. Table of Contents

Owner Instructions Original Instructions Warning! Read instructions before using the machine. LoLine NLL 332 NLL 415

Instruction Manual. Cheese Warmer with Pump

USER-MANUAL Tamson Cool Cube Immersion Cooler

Digital 7 Square Plate Magnetic Stirrer

20 High Velocity Fan with 135 Tilt Head

LABORATORY OVENS MODELS INCLUDE: TO-152G & TOH-152G TO-152F & TO-235F DEHYDRATING OVENS MODELS INCLUDE: TD-150F TD-330F TD-500F

Intrinsically Safe Transmitters, Option Code 2n

Professional Warming Drawer and Warming Drawer Cabinet

Operation Manual (Version 1.4.4)

Condensate Pump. Installation and Safety Instructions CP-16 CP

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Paint-Sample Dryer ST-01

KHM800 Professional 800w haze machine

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Low Speed Centrifuge. Model XC-2415 Model XC-2450 Operating Manual

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

3KW ELECTRIC FAN HEATER

Operating Instructions & Parts Manual Models 99533, 99532

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

Certificate of Compliance

Operator s Manual CHEESE MELTER/WARMER OVEN ENGLISH

Superdryer Dehumidifiers

Corning LSE Digital Dry Bath Heater

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

USER MANUAL TMT-ASTC100

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

With this symbol Gavita declares that this product complies with legal European requirements.

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

Performer Cuspidor. Installation Instructions. (For Performer III Chair & International Performer I Chair) You Will Need. About This Install

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

Bench Series Ovens Models 21 / 31 / 51 Operating Manual

PLEASE READ AND SAVE THESE INSTRUCTIONS

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

ANNEALING FURNACE MODEL 414 User Maintenance Manual/Handbook

Certificate of Compliance

Hot Water Urns v3.0. all models. Helpline. instructions.indd 1 02/06/ :50

Spice / Coffee Grinder Instruction Manual

Magnetic Stirring Systems with Heat

Instructions for the fan motor control system, SILVER C

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

60In. Ceiling Fan. Owner s Manual

PS-3401 Heater / Stirrer

High-Velocity Floor Fan

- Oscillating Table Model Fan

E-1 EDGER POLISHER/SCRUBBER

Transcription:

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance & Servicing............ 2 Environmental Conditions............ 2 Safety Instructions............ 2 Standards & Regulations............ 3 Specifications............ 3 Introduction............ 4 Operating Instructions............ 4 Package Contents Analog Vortex Mixer 72 (183cm) power cord Instruction manual 1 Warranty Manufacturer warrants this product to be free from defects in material and workmanship when used under normal conditions for two (2) years. Register your equipment or instrument online at www.vwrsp.com/warranty for US residents or www.vwrcanlab. com/warranty for Canadian residents. For your reference, make a note of the serial number, date of purchase and supplier here. Serial Number: Date of Purchase: Supplier:

Installation Upon receiving the VWR Vortex Mixer, check to ensure that no damage has occurred during shipment. It is important that any damage that occurred in transport is detected at the time of unpacking. If you do find such damage the carrier must be notified immediately. After unpacking, place the Vortex Mixer on a level bench or table, away from explosive vapors. Ensure that the surface on which the unit is placed will withstand typical heat produced by the unit. Always place the unit on a sturdy work surface. The Vortex Mixer is supplied with a power cord that should be plugged into a properly grounded outlet. If the supplied power cord does not meet your needs, please use an approved power cord that suits local codes and electric supply. Replacement of the plug must be made by a qualified electrician. Maintenance & Servicing The Vortex Mixer is built for long, trouble-free, dependable service. No lubrication or other technical user maintenance is required. The unit should be given the care normally required for any electrical appliance. Avoid wetting or unnecessary exposure to fumes. Spills should be removed promptly. Do not use a cleaning agent or solvent on the front panel which is abrasive or harmful to plastics, nor one which is flammable. Always ensure the power is disconnected from the unit prior to any cleaning. If the unit ever requires service, contact your VWR representative. Environmental Conditions Operating Conditions: Indoor use only. Temperature: 4 to 40 C (39.2 to 104 F) Humidity: 20% to 85% relative humidity, non-condensing Altitude: 0 to 6,562 ft. (2000 M) above sea level Safety Instructions Please read the entire instruction manual before operating the Vortex Mixer. Warning! Do not use the Vortex Mixer in a hazardous atmosphere or with hazardous materials for which the unit was not designed. Also, the user should be aware that the protection provided by the equipment may be impaired if used with accessories not provided or recommended by the manufacturer, or used in a manner not specified by the manufacturer. Always operate unit on a level surface for best performance and maximum safety. Cup head is permanently attached to the unit. DO NOT try to remove or permanent damage will occur. Caution! To avoid electrical shock, completely cut off power to the unit by disconnecting the power cord from the wall outlet. Disconnect unit from the power supply prior to maintenance and servicing. Spills should be removed promptly. Do not immerse the unit for cleaning. Do not operate the unit if it shows signs of electrical or mechanical damage. Earth Ground - Protective Conductor Terminal Alternating Current Non-Operating Storage: Temperature: Humidity: -20 to 65 C (-4 to 149 F) 20% to 85% relative humidity, non-condensing Installation Category II and Pollution Degree 2 in accordance with IEC 664. 2

Standards & Regulations Henry Troemner LLC hereby declares under it s sole responsibility that the construction of this product conforms in accordance with the following standards: Safety standards: IEC 61010-1 IEC 61010-2-051 UL Std. No. 61010-1 EMC standards: IEC45501 IEC61000-4-2 IEC61000-4-4 IEC61000-4-6 EN55022A Safety requirements for electrical equipment for measurement, control and laboratory use. Part I: General Requirements. Part II: Particular requirements for laboratory equipment for mixing and stirring. IEC6100-3-2/3-3 IEC61000-4-3 IEC61000-4-5 IEC61000-4-11 Analog Vortexer Mixer Specifications Overall dimensions (L x W x H): 7.75 x 6 x 5.5 (19.7 x 15.2 x 14cm) Electrical (50/60 Hz): 120V, 1.2 amps, 150 watts Speed range*: 300 to 3200rpm Orbit: 0.194 (4.9mm) Duty rating: intermittent duty Controls: auto/off/on rocker switch, speed knob: variable 1 to 10 dial marks Ship weight: 11.7lbs (5.3kg) Associated EU guidelines: EMC directive 2004/108/EC LVD directive 2006/95/EC RoHS directive 2011/65/EU 3

Vortex Mixer Introduction Your Vortex Mixer is ready for most one-handed applications. The Vortex Mixer operates by mixing tubes just prior to testing. Operating Tips These units are not intended for continuous use over extended periods of time. A built-in temperature sensor will prevent the unit from overheating by shutting the motor down. If this occurs, allow the motor to cool down and the unit will be able to resume normal operation. Decrease the duration of the time unit is used between rest periods. NOTE: The cup head is permanently attached to the unit. DO NOT try to remove or permanent damage will occur. Analog Vortex Mixer Operating Instructions 1. Make sure the 3-way rocker switch is in the center, off position. Plug the power cord into a properly grounded outlet. 2. For continuous operation, push the rocker switch to the right, on position. For intermittent/touch operation, push the rocker switch to the left, auto position. 3. In either case, turn the speed knob to 1. In the on position, you will see the head in motion immediately. In the auto position, the vessel you are using must be pushed down on the head attachment to achieve motion. To get the desired mix, vary the speed, using the speed knob, and/or vary the angle of contact and pressure against the head. 4. When finished with either continuous or intermittent operation, return rocker switch to the center, off position. 5. The intermittent, auto mode is intended for short mixing times of one (1) minute or less at full speed. A rest period of two (2) minutes is recommended to minimize the possibility of overheating the motor. The unit can become warm to the touch with constant use. There is nothing wrong with it. At high performance settings the motor (UL recognized component) simply puts out more heat. 6. To completely cut off power to the unit, disconnect the power cord from the wall outlet. Manufactured by: Troemner LLC 201 Wolf Drive Thorofare, NJ 08086-0087 Phone: 856-686-1600 Fax: 856-686-1601 E-mail: troemner@troemner.com www.troemner.com 715115-00 (REV 2-8/15)