ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

Similar documents
ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-10/(PGEN-10E)

STEP 1: SELECT A NITROGEN GENERATOR STEP 2: SELECT A VENT STEP 3: SELECT MONITORING EQUIPMENT STEP 4: CONTACT ECS

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

ECS Protector Nitrogen Generator. ECS Protector Nitrogen Generator PGEN-30. Specifications

ECS Pre-Engineered Nitrogen Generator. ECS Pre-Engineered Wall Mount Nitrogen Generator PGEN-3/(PGEN-3E) PGEN-5/(PGEN-5E)

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA. 319a. January 27, 2012

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

TOTALPAC2 Integrated Fire Protection System

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

CONDENSATE MANAGEMENT SYSTEMS

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

MODEL MW200 MODEL MW600 AIR DRYER

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Refrigerant Recovery Unit, Model RRU134

TECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)

Columbia Boiler Company

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

TotalPac X Single interlock SUREFIRE system

White Paper. Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

SYSTEM 2000 CHILLED WATER (CAC) EC SERIES -INSTALLATION OPERATIONS AND MAINTENANCE MANUAL-

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

TotalPac 3 Firecyle III Deluge Remote controlled system

AGF Manufacturing Inc.

R E D I C O N T R O L S

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Condensing Unit Installation and Operating Instructions

BASIL 6000 TUNNEL CAGE WASHER

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

CONDENSATE MANAGEMENT SYSTEMS

TotalPac X Firecycle III Preaction Double interlock system

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

LGB Gas fired boiler

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

KR Series Air Defrost Unit Coolers Operating and Installation Manual

AUTO-PURGER AP. Noncondensible Gas (Air) Refrigerant Purger. Model APW OPERATOR INSTALLATION & INSTRUCTION MANUAL

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

TECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

Packaged Semi-Instantaneous Steam Fired Water Heater

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

TROUBLESHOOTING GENERAL TROUBLESHOOTING PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

BERMAD Fire Protection

TECHNICAL DATA. model c-2

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

User s Information Manual

Centro-Matic Automated Lubrication Systems System Controls

PURGER INSTALLATION AND OPERATION BULLETIN PUR-SB17-02 SERVICE BULLETIN

Instructions for Installation, Operation, Care and Maintenance

Worldwide Contacts.

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

CSD-1 COMMERCIAL BOILER CONTROLS

L A signature series TA T N E RE O, A L L A T S IN

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

PowerVac G Single to Twin Conversion Kit [ ]

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

AGF Manufacturing Inc. Model Owner s Manual INST-5400A_V /15

HEAT GENERATION 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS. B. Section HVAC Basic Materials and Methods

MANUAL RESET ALARM RELEASE

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

High Output Vacuum/Pressure Pump

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

TECHNICAL DATA OBSOLETE

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

PMT200A SERIES DEHYDRATOR USER MANUAL. Bulletin AE01B-A NOV 05

DUAL BREWER AUTOMATIC DB2A

Intelligent Refrigeration Solutions

KR Electrical Defrost Unit Coolers (PN E108318_E)

Liebert InteleCool Warranty Inspection Check Sheet

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

SAFETY VACUUM RELEASE SYSTEM (SVRS)

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Liquid Drainers LIQUID DRAINERS

P4200PM / P5000PM Remote Air Dryer User s Guide

Technical Data. Installation

Transcription:

ECS Protector - PSV-D (PSV-DE) Specifications For use under U.S. Patents 8,720,591, 9,144,700, 9,186,533 and 9,610,466 Stock Number : Service Pressure: System Connection: Electrical Connection: Temperature Range: Dimensions Vent Assembly: Control Box: PSV-D/(PSV-DE) Up to 175 PSIG (12 Bar) 1 NPT Male 120VAC/60 Hz (230 VAC/50 Hz); <2 amps 40 F to 120 F (4.5 C to 49 C) 13.5 (W) X 4.25 (D) X 7.5 (H) (243mmW) X 108mm(D) X 191mm(H)) 9 (W) X 7 (D) X 10 (H) (229mm(W) X 178mm(D) X 254mm(H)) Support Hanger Not Required General Description The ECS Protector provides automatic oxygen venting in dry pipe fire sprinkler systems. As a fire sprinkler system is filled with a continuous supply of nitrogen gas from the ECS Protector Nitrogen Generator System, the ECS Protector allows oxygen rich gas to be vented from the fire sprinkler system. Over a short period of time the ECS Protector will almost completely remove oxygen from the fire sprinkler system (< 2% oxygen). Once the desired system gas composition is reached the ECS Protector Dry SMART Vent will automatically close and prevent continuous venting. The ECS Protector must be installed as shown on the engineering design documents. If a location is not specified, install the ECS Protector on the fire sprinkler system riser on the system side of the main control valve. The electric control box must be installed on an adjacent wall near the fire sprinkler system riser (see Figure 4). The ECS Protector is equipped with a levered float valve that allows gas to discharge but prevents liquid water from leaking through the restricted venting orifice in the event that water enters the fire sprinkler system. A back pressure regulator is also included to prevent total system depressurization from the vent assembly before the vent is electronically closed. The restricted venting orifice allows oxygen to be vented from the fire sprinkler system at a controlled rate to achieve a minimum nitrogen concentration of 98%. A special fitting is provided to receive 5/32 tubing when the vent is used in conjunction with the ECS Protector SMART Gas Analyzer (SGA-1/SGA-1E). DRY SMART VENT - PSV-D/(PSV-DE) May 2018 - Rev 1 1

The ECS Protector is equipped with an electronic solenoid valve that must be wired to the electric control box (conductors not included). The control box will automatically close the vent once the desired nitrogen concentration has been reached. The control box is equipped with an on/off switch and a vent button to provide a means to restart of the venting process should oxygen be reintroduced into the fire sprinkler system. Installation Instructions 1. The ECS Protector includes two (2) separate components. The first component is the vent assembly equipped with a ball valve to be connected to the fire sprinkler riser. The contractor shall install a 1 outlet (welded or mechanical) to connect the vent assembly to the sprinkler system on the system side of the main control valve (see Figure 2). The isolation ball valve shall remain in the closed position until the ECS Protector Nitrogen Generator System has been commissioned. 2. Install the vent assembly in a level position. Recommended mounting height is between 5-10 (1.5m-3m) above the finished floor. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent assembly to vent oxygen from the fire sprinkler system. 3. The second component of the ECS Protector Dry SMART Vent is the electric control box. The control box must be installed on a wall or vertical surface adjacent to the vent assembly installation location. 4. Provide conductors from 120VAC/60 Hz (230 VAC/50 Hz) power supply to designated terminals in the electric control box per NFPA 70 and local requirements (see Figure 1). The device draws less than 2 amps. Contractor must drill hole in the control box for the 120VAC/60 Hz (230 VAC/50 Hz) power supply conductors. 5. Provide conductors to connect the 120VAC/60 Hz (24VDC) coil leads of the electronic solenoid valve on the vent assembly to the designated terminals in the electric control box per NFPA 70 and local requirements (see Figure 1). Contractor must drill hole on side or top of the control box to provide access. 6. The green power switch on the electric control box must remain in the OFF position until the ECS Protector Nitrogen generator has been commissioned. 7. Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. The inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. NOTE: Inspection must include verifying the condition of the inline filter and checking for blockage in the Y strainer and the restricted venting orifice. FIGURE 1a ECS Protector Control Box 120VAC Solenoid G L N G/Y OR PSV-D 120v/60 HZ 1 Phase OR DRY SMART VENT- PSV-D/(PSV-DE) May 2018 - Rev 1 2

FIGURE 1b ECS Protector Control Box (24VDC) Solenoid Operating Instructions G L N G V- V+B V+B V+C 1. Verify the vent assembly has been equipped with a restricted venting orifice downstream of the backpressure regulator. NOTE: If the vent assembly is not equipped with a restricted venting orifice, one will be provided by ECS during system commissioning. The restricted venting orifice must be installed before proceeding with the steps below. 2. Determine the low air alarm pressure and normal operating pressure of the fire sprinkler system. 3. Choose a pressure setting for the backpressure regulator that is 3-5 psig (.2-.3 bar) to above the low air alarm pressure but below the normal operating pressure of the fire sprinkler system. 4. Pull the grey knob out from the regulator to adjust pressure setting. Turn the knob clockwise to raise the pressure, counter-clockwise to lower the pressure. BL R (PSV-DE) 230v/50 Hz/1 Phase 5. Close the isolation ball valve and allow device to depressurize through restricted venting orifice to pressure setting. Make adjustment to pressure setting using the knob, then open the isolation ball valve to pressurize device and close the isolation ball valve again to check pressure setting. Repeat process until desired pressure setting is achieved NOTE: This process can only be performed when the solenoid on the vent is energized and fire sprinkler system is at normal operating pressure. 6. Push grey knob back into regulator until it clicks into place. 7. Verify the timer settings inside the electric control box. The settings should be as follows: mode set to E, scale set to 20, 30, 40, 50, 60, range set to 10h, and timer knob set to 35. If needed, a small flathead screwdriver can be used to make the timer setting adjustments. 8. Once the ECS Protector Nitrogen Generator System has been commissioned, open the isolation ball valve on the vent assembly, turn the green power Maintenance Instructions 1. The ECS Protector SMART Vent must be inspected annually at minimum. While the isolation ball valve is in the open position check for air/water leaks and ensure the pressure gauge is displaying normal system pressure. 2. While isolation ball valve is in closed position inspection must include the condition of the inline filter and for blockage in the Y strainer and restricted venting orifice. Twist the black filter housing clockwise until it can be removed to expose the filter element. 3. The filter element in the in-line filter should be replaced if a visual inspection reveals a significant collection of debris. DRY SMART VENT - PSV-D/(PSV-DE) May 2018 - Rev 1 3

In-Line Filter Replacement Instructions 1. Close the isolation ball valve. 2. Depressurize the housing by pressing the Schrader valve on the bottom of the in-line filter housing. 3. Remove the lower section of the in-line filter housing by turning the filter housing counterclockwise. NOTE: A rubber o-ring/seal is located between the upper and lower sections of the filter housing. 4. Remove the old filter by turning the filter counterclockwise. 5. Replace with new filter (PV-DRF). The filter is secured to the housing by turning the filter clockwise. NOTE: Ensure the filter is secured only finger/hand tight. 6. Install the rubber o-ring/seal on the lower section of the filter housing. 7. Re-install the filter housing by turning the filter housing clockwise. NOTE: Ensure the filter housing is secured only finger/hand tight. FIGURE 2 ECS Protector Assembly Float Valve In-Line Filter Backpressure Regulator Solenoid Restricted Venting Orifice Muffler ½ Union Gas Sampling Port Connection To Sprinkler System Y Strainer with Ball Valve Isolation Ball Valve DRY SMART VENT - PSV-D/(PSV-DE) May 2018 - Rev 1 4

FIGURE 3 In-Line Filter Filter Housing Filter Schrader Valve FIGURE 4 ECS Protector Installation Schematic Vent Assembly Wiring Harness Installed In Conduit Control Box Mounted To Adjacent Wall Fire Sprinkler Riser Nitrogen Supply DRY SMART VENT - PSV-D/(PSV-DE) May 2018 - Rev 1 5

Wall Mount Total System Capacity Skid Mount Stand Alone w/ Air Compressor PGEN-3 PGEN-5 PGEN-10 PGEN-20 PGEN-30 PGEN-40 PGEN-50 PGEN-60 675 gal 950 gal 2,000 gal 3,200 gal 6,500 gal 11,000 gal 18,500 gal 22,500 gal Single System Capacity @ 40 psi (1) 215 gal 265 gal 560 gal 950 gal 1,150 gal 1,440 gal 2,025 gal 2,900 gal Single System Capacity @ 20 psi (1) 540 gal 590 gal 1,120 gal 1,800 gal 2,300 gal 2,880 gal 4,050 gal 5,800 gal Air Compressor Size (H x W x D) 36x24x9 36x24x9 38x29x11 57x32x40 Weight 115 lbs 125 lbs 175 lbs 420 lbs 152 lbs(2) 264 lbs(2) 300 lbs(2) 300 lbs(2) (1) (2) (3) Single system capacity based on 30 min. fill requirement of largest single sprinkler system; a secondary air compressor with normally closed isolation valve can be used to meet fill requirement for larger individual systems Size and weight of nitrogen generator only, does not include separate air compressor All nitrogen generators include 1 year manufacturer s warranty per ECS terms and conditions Engineered Corrosion Solutions 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com 6