Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Similar documents
SELF-PRIMING JET PUMPS

Hot Water Circulator Pump LRP

V80-H Multistage Pump Instruction Manual

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

This label warns for risk of electrical shock when failing to observe.

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

submersible water pumps

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Specifications. Vacuum motor power consumption(w/hp) 1200 / 1.6. Exhaust water pump power consumption(w/hp 800 / 1.1

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

VADA - Rain2Main Automatic Rainwater Controller

HEAT RECOVERY AIR HANDLING UNIT

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Tempest TP420/180 Electric Pressure Washer

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

OWNERS GUIDE TO INSTALLATION AND OPERATION

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

APW PSI PRESSURE WASHER

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

DOMINATOR IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

2.9kW Portable Air Conditioner

Electric Salamander CHM-1200W CHM-2400W CHM-4350W. User s Manual

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

EH W Pressure Washer

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

30-pint Dehumidifier User Guide

2.9kW Portable Air Conditioner

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Instructions for the Use and Care and Installation of ORC97G ORC98G. Glass Canopy Rangehoods

DIRTY WATER SUBMERSIBLE PUMP

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Operation Manual. Trash Water Pump ARTICLE Image similar

DIRTY WATER SUBMERSIBLE PUMP KIT

Combivac Operating Instructions Combivac

LC Series - Light Commercial Pump Station Installation and Operation Manual

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

OPERATION AND MONTAGE MANUAL ROOF FANS

6000, 8000, & 15000

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

12/50 CENTRIFUGAL PUMPS FOR DC SUPPLY OPERATING INSTRUCTIONS

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

OPERATION AND MONTAGE MANUAL ROOF FANS

NON-SUBMERSIBLE WATER PUMP

PJ130S High Pressure Cleaner

Bar Fridge USER MANUAL MB46W

CC Series VACUUM PUMPS

Centrifugal inline fans

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

ALL IN ONE SERIES HOTLINE 1300 AQUATEC INSTRUCTION MANUAL MODEL 03AS310 03AS311. DATE JULY 2017 v2.0. AQP All in One 1000 Instructions.

Instructions for installation and use English. More documents on: H B /09

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

OPERATION & MAINTENANCE INSTRUCTIONS

FHA 1100 A1 Domestic Water Pump

Service Manual Washing Machine

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

CLEAN WATER SUBMERSIBLE PUMP

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Classic Heater Pool Controller

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

ORC93XA ORC94XBA. Wall Canopy Rangehoods

Operating instructions

AXIAL FANS USER S MANUAL

Pump WaterVISE, FloVISE

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

TAW H1 D. Instruction manual. /Model. Electric air washer.

Assembly- and User Manual Electric Infrared- Patio Heater MODEL: Geda HS - 2 kw Art. Nr. HS 10000

CLEAN WATER SUBMERSIBLE WATER PUMP

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

e Bath Fan with Light User s Guide

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

owner s manual & parts list

ARTICA. 8000Btu. Room Air Conditioners Portable Range

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

CH250 AND CH251 CHILLERS

model No: ir20.v2 FUSE

PV3000S Professional Pond Vacuum

OPERATING INSTRUCTIONS

2 IN 1 SUBMERSIBLE PUMP

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Reverse Cycle Portable Air Conditioner with Dehumidifier

10cm Desk Fan User Manual

Models: RP-10, RP-15, RP-20. User Manual

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

Transcription:

CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

Congratulations on your purchase of a LEO Centrifugal Pump It is important that you read, fully understand and observe the following safety precautions and warnings. Careless or improper use of the machine may cause serious or fatal injury. The user is responsible for any accidents involving other people or other people s property. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. Attention! If the appliance or the supply cord is damaged, it must be repaired by manufacturer, its service agent or qualified person- Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. Applications It is applicable to household water supply, equipment support, pipeline pressurization, garden watering, vegetable greenhouse watering, fish farming and poultry raising, industrial and mining, water supply and drainage of enterprises and high-rise buildings, central air conditioner and centralized heating circulation system, etc. Transfer clean water and other non-corrosive liquids with low viscosity; do not transport inflammable, explosive, gasified liquids and liquids containing solid particles or fibers. The PH of water must between 6.5 and 8.5. Model description

Technical Data Max. flow: 1600L/min Max. head: 110m Output power: 0.25~7.5kW Max. suction:8m Insulation class: IPX4 Protection class: F Max. ambient temperature: +40 Max. liquid temperature: +60 Type ACm60 ACm75 ACm150 ACm150B2 Power 600 W / 0,8 HP 750 W / 1,0 HP 1500 W / 2,0 HP 1500 W / 2,0 HP Inlet/outlet diameter 1 / 1 1 / 1 1,25 / 1 2 / 2 Qmax 5,4 m3/h 6,0 m3/h 8,4 m3/h 30 m3/h Hmax 25 m 33 m 45,5 m 22 m Max. Suction 8 m 8 m 8 m 8 m Gross weight 11,5 kg 13,4 kg 22,8 kg 20,7 kg Package 333x215x260mm 333x215x260mm 425x265x310mm 415x225x285mm Implementation Standards IEC/EN 60335-1 Household and similar electrical appliances--safety Part1: General requirements. IEC/EN 60335-2-41 Household and similar electrical appliances-- safety Part2-41: Particular requirements for pump. 2006/95/EC Low voltage directive

Safety Precautions To ensure normal and safety operation of the electric pump, read the manual carefully before use. The electric pump should have reliable grounding to prevent short circuit; for safety, leakage protection switch should be equipped and be careful not to wet the power plug; socket should be connected in damp - proof area. Do not touch the electric pump while working; do not wash, swim near working area or let livestock into the water to avoid accidents. Avoid splashing pressured water to the electric pump as well as prevent the pump immersed by water.

Keep the pump in ventilation. In case ambient temperature is lower than 4 or the pump is not used for a long time, empty liquid the pipeline system to avoid ice cracking of the pump chamber. Do not operate the pump for a long time without water in it. The pumped liquid maybe hot and under high pressure, before moving and demounting the bump, valves in both sides of the bump should be turned off first and then empty liquids in the pump and pipelines so as not to be scalded. Do not transfer any inflammable, explosive or gasified liquids that beyond the stipulation. Ensure the pump will not be accidently turned on while installing and maintaining; if not used for a long time, cut off the power first and then turn off valves in inlet and outlet of the pump. Power supply should be in accordance with the voltage stated in the nameplate. If not used for a long time, put the pump in dry, ventilated and cool place under room temperature.

Product Structure POS. Part POS. Part 1 Pump body 10 Fan 2 Impeller 11 End plate 3 Mechanical seal 12 Capacitor 4 Seal holder 13 Capacitor box 5 Pump support 14 Terminal board 6 Bearing 15 Stator 7 Rotor 16 Bracket 8 Spring washer 17 Cable holder 9 Fan cover 18 O-sealing ring

Pipeline Installation This product should be installed and maintained by personnel who is proficient in this manual and has special qualifications. Installation and operation should be in accordance with local regulations and recognized operation standards. Install pipelines properly as stipulated in the manual and meanwhile conduct frost protection measures for the pipeline. For the installation, the inlet pipe should be as short as possible with the least turnings. The pump should be installed in ventilated and dry environment. It could be installed outside, provided having proper covering to prevent rain and wind. For pipeline use, valves should be installed on inlet and outlet pipelines and the inlet pipeline should be installed with check valve.

Correct Installation Diagram A Correct Installation Diagram B A: 1. Foot valve 2. Inlet pipe 3. Tie-in 4. Filling plug 5. Drain plug 6. Electric pump 7. Valve B: Installation precautions for inlet pipelines 1. While installing the electric pump, do not use too soft rubber tube for the inlet pipeline, avoiding to be sucked flat. 2. The foot valve should be vertically placed and installed 30cm from water bottom to avoid sucking in sands and stones (B2) 3. Joints of the inlet pipelines should be sealed with the least elbows; no water can be sucked. 4. Diameter of the inlet pipe should be at least in accordance with that of the water inlet, to avoid too much water loss which will influence outlet performance. 5. Pay attention to drop of water level while using, the foot valve should not be above the water surface (B1). 6. In case the inlet pipe is longer than 10m or its lifting height exceeds 4m, the pipe diameter should exceed diameter of water inlet of the pump. 7. Ensure the pumped will not be affected by pipeline pressures while installing the pipelines. 8. Filter should be installed in inlet pipelines so as to avoid solid particles to pump. C: Installation Precautions of the outlet pipeline Pipe diameter of the outlet pipeline should be at least in accordance with that of the water outlet, so as to reduce its voltage drop, high flow rate and noise to the minimum.

Electrical Connection Unless the power is off, do not wiring the junction box. The electric pump should have reliable grounding to prevent current leakage with leakage protection switch being equipped. Electrical connection and protection should be conducted according to stipulations. Specification of working voltage is marked on the nameplate; please ensure the motor is in accordance with power supply. In case the working area of the electric pump is too far from the power supply, power transmission lines should be of a heavier gauge, otherwise the electric pump cannot work normally because the voltage drop is too dramatic. A rubber extension cable shall be applied for the electric pump in case of outdoor use. Check rotation of the motor (three-phase motor). Check whether operation of the electric pump is normal, rotation is correct, which could be observed from the fan blade terminal, e.g. clockwise rotation means correct direction. In case the rotation is incorrect, cut off power and exchange the two power cables.

Start-up and Maintenance Do not start up the pump before the pump chamber is filled with water. Do not touch the electric pump unless its power has been cut off for at least 5 minutes. Do not dismount the pump body unless water in the pump chamber is emptied. Rotate the fan blade before start- up, check whether the pump rotation is flexible and then unscrew the water-filling plug, fill the pump chamber with clean water from the water injection hole, then tighten the plug screw after the air has been completely discharged. The valve should be shut tightly while starting up the pump. After the pump discharges water and operates normally, adjust the valve to the required flow (working range is displayed on the nameplate). Attention: In case no water is discharged after being started for more than 5 minutes with water filled, turn off the electric pump, re-fill water or check whether the inlet pipeline has leakages In case of any frost and ice damages, please open the drain plug to empty water in the pump chamber. When start up the pump again, open the drain plug, fill water and tighten it and then the pump is usable. In case not use for a long time, water in the pump should be emptied. The pump body, impeller and support should be cleaned and coated with anticorrosive oil before they are put in a ventilated and dry place for use. In case the pump is halted for a long time, start it up again according to above diagram. In summer or when the ambient temperature is high, pay attention to ventilation, avoid dew on electrical parts which will result in electrical faults. In case the motor is hot or abnormal, cut off the power immediately and check faults according to the following table.

Troubleshooting Check the pump after power cut-off. Symptom Cause Corrective Action The motor cannot be started The motor is in operation, but no water is discharged Single-phase power supply (three-phase electric motor): a. poor connection of the power switch; b. fuse is burned out; c. loose power lead; phase failure of the cable. Capacitor is burned out. The rotating shaft and bearing are jammed. Impeller is jammed. Stator winding is damaged. Incorrect direction of pump rotation. The pump is not fully filled with water. The impeller is damaged. Leakage of the suction pipe. Water level is too low. Freeze caused by accumulated water in the pipeline or the chamber. a. repair switch contact or replace the switch; b. replace the safety fuse; c. check and tighten the power connector; d. repair or replace cables. Replace with a same type capacitor (send to the maintenance point for repair). Replace the bearing (send to the maintenance point for repair). Turn rotating shaft of the fan blade terminal with screw driver to let it rotate flexibly or demount the pump body to clear sundries. Replace winding coils (send to the maintenance point for repair). Invert two-phase wirings of the motor (three-phase motor). Re-fill the pump with water. Replace the impeller (send to the maintenance point for repair). Check sealing of various joints of the inlet pipelines. Adjust installation height of the pump. Start up the pump after ice is melted. Insufficient pressure Incorrect pump type. Select suitable pump.

Insufficient pressure Motor works intermittently or the stator winding is burned out Leakage of mechanical seal Abnormal noise from the pump The inlet pipeline is too long or with too many bends, pipe diameter is not selected as required. Inlet pipeline, filter screen or pump chamber is blocked by foreign materials. The impeller is jammed or under overload operation for a long time. Incorrect grounding, broken cable or the electric pump is hit by lightning. The mechanical seal is worn and torn by impurities. Noise from the bearing. Impeller is jammed Excessive flow. Apply the pipe with the stipulated diameter, and make the inlet pipe short. Clean pipeline, foot valve or pump chamber, clear sundries. Clear sundries in the pump chamber; operate the pump under the rated flow as much as possible. Seek for the reason, and replace winding coils. Clear or replace the mechanical seal. Replace with the same type bearing. Remove foreign materials. Adjust to the range displayed on the nameplate before use.

Guarantee terms Please carefully retain the guarantee card completed by the seller, or the proof of purchase. Pre-conditions for the 24-month guarantee entitlement: - Deployment of the device solely for private use. The guarantee is reduced to 12 months in the commercial sector or leasing business. - Proper handling and observance of all information given in the operating manual, which forms part of our guarantee terms. - Observance of the prescribed maintenance intervals - No unauthorized alteration of the design. - Presentation of the completed guarantee card and/or proof of purchase. Any guarantee claim shall be immediately void in the event of unauthorized repairs. Faults and defects, which can be traced to material or manufacturing faults will be rectified exclusively by our contracted workshops (the seller has the right to remedy a defect) in your vicinity or by the manufacturer if the latter is closer. Any claims going beyond the provision of a guarantee are ruled out. Any transport damage should be reported not to us but to the shipper in question since, otherwise, any compensation claims the shipper would be voided. Information concerning the packaging materials The used packaging materials must be thrown into the relevant waste collector. In case of the need of any parts, questions or service instructions please contact: szerviz@gamagarden.eu +36 30 508-6563 Acquaer Ltd., 4900 Fehérgyarmat, Szatmári u. 11 certifies CE conformity of the above-mentioned product and that it complies with the technical data specified in the data plate and the Operating instructions. You can get detailed information about the CE declarations at: www.gamagarden.eu