United Kingdom. Smart Thermostat Low Voltage Digital Installations. Guide for Professional Installers

Similar documents
United Kingdom. Smart Thermostat 230 V Relay Installations. Guide for Professional Installers

Manual & Technical Documentation V1.1

Smart Thermostat. tado GmbH Lindwurmstr Munich tado.com

Smart Thermostat. User Guide

For the heating engineer. Installation manual. Interface 0-10V VR34

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

SMART THERMOSTAT WITH HOT WATER CONTROL

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

Modulating clock thermostat

Installation Instructions VITOTRONIC 300

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

WF/DV7500, 6500, Smart Home Integration

Installation Instructions VITOTRONIC 200

The new ecotec exclusive from Vaillant with Green iq technology

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

Installation manual Anna. In combination with the Smile T. Manual PW version 2.0

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

System Installation. multi-zone heating

Service Instructions for use by heating contractor

For the operator/for the heating engineer. Operating and Installation Manual VRC 430. Weather compensator VRC 430

VR 90 Remote control unit

Supplement to operating and installation manual no for the VR 81 remote control unit

Table 1. Serie of Digital Room Thermostats.

Hive Active Heating. Thermostat installation guide

Skyport Wi-Fi Installation for the ColorTouch in 5 Easy Steps

Thermostat install guide

Technical Data Manual

Product Catalogue 2016/2017

Model: A Quick Setup Guide DC: Atomic Projection Alarm Clock

Nest Thermostat E Pro Installation & Configuration Guide

Smart Starter Bundle. Hub. Smart Motion Sensor. Smart Door/ Window Sensor

Replacing a wall-mounted thermostat

Overview - Danfoss Link and living software versions

How to Include Your Thermostat

Vokèra OpenTherm 711 with external sensor connected

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Easicom. Quality, reliability, flexibility

Boiler. Introducing the NEW RT520 / RT520RF. Thermostats PLUST

Installation manual Anna. In combination with the Smile T230. Manual PW version 2.0

Vaillant vsmart. Sales Presentation. Search vsmart for the App, which includes a demo!

For heating engineer/user. Operating and Installation Manual VRC 630/2. Weather compensated cascade control VRC 630

Sync. Smart Home Alarm

Wireless Controls System Guide

Replacing a wall-mounted thermostat

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

TV2 Room Pressure Monitor Quick Start Guide

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Underfloor Catalogue Heating products that define the market

Model: Av2 Quick Setup Guide DC: Atomic Projection Alarm Clock

BeSMART Thermostat. EN Thermostat Manual

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Communication. Versatronik 581 & 581D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

O CRC100. Comfort Room Controller (2015/01) en

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

APPLIANCES CONTROL SECURITY HEATING

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Operations Manual TS400. Test Station for G450/G460 Gas Detector

The guarantee on this appliance is valid for 12 months from the first day of installation.

Overview - Danfoss Link and living software versions

Roth Touchline. German quality since User manual quick and easy guide 1/10

SMART HOME SYSTEM + + IMIT CONTROL SYSTEM

Vokèra OpenTherm 711 without external sensor connected

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

ETN1000/MIGA - Operating manual

Replacing a wireless thermostat

Domestic Gas Boiler Guide

Easy-Stat. Wireless Programmable Room Thermostat Pt No

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

RedLINK Connects RedLINK Wireless Comfort Systems

SmartHeater. 100 years of solutions for your home, made in Norway

Roth Touchline. German quality since Quick and easy user manual 1/10

Mixer module VR 61. Operating and Installation Manual. Mixer module for VRC 430 / VRC 430f

CONTROL PANEL REMOTE FEATURES INFORMATION ACCOUNT SETTINGS CONTROL PANEL REMOTE FEATURES INFORMATION SETTINGS. Connected

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Installation & User s Instructions

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

RedLINK Wireless Comfort Systems. RedLINK Connects.

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

DC 60 & DM 60 displays

Operating instructions

Model: T83653v2 Instruction manual DC: WIRELESS COLOR FORECAST STATION Mold Risk for Forecast Station & Indoor Remote Sensor Location

Instruction Manual. Please read this manual and the Safety Instructions carefully before using your refrigerator.

Pandora Smart Pro QUICK START GUIDE. model

HRX3000. Technical Manual

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Transcription:

United Kingdom Part 2 of 2 Smart Thermostat Low Voltage Digital Installations Guide for Professional Installers If you are not a professional installer and want to install tado yourself, get step-by-step instructions at tado.com/start

POLARITY-PROTECTED WIRING For all two-wire digital installations the wires connected to + and - on tado can be interchanged CAUTION Make sure to turn the power off before you start 10/2018

Optional Accessory Use the tado Trim Plate behind the Smart Thermostat or Extension Kit if needed. This can be obtained separately at tado.com/trim-plate

OpenTherm 1. Wiring: OpenTherm Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 4

OT OpenTherm Boiler Smart Thermostat MAX 36 V DC OT Boiler Extension Kit The Extension Kit requires a separate 230 V power supply at N and L for OpenTherm installations 5

OpenTherm 2. Connect Internet Bridge to Router If no free USB jack available - plug to power socket 6 Connect Internet Bridge to router Press pairing button until the LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge

3. Pair Extension Kit with Internet Bridge Wireless Setup: Smart Thermostat installed wirelessly with receiver OpenTherm Smart Thermostat & Extension Kit 3 SEC 2 MIN Blinking 4x short - pause -... Fast Blinking Press button for 3 sec until LED starts blinking fast Paired Blinking 2x short - pause -... If failed: Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 7

OpenTherm 4. Pair Smart Thermostat with Internet Bridge 2 MIN 3 SEC Remove battery strip and press button Press button for 3 sec - release Pairing Paired If failed: Press the button to clear the error Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 8

Open Installer Menu OpenTherm 2 MIN 3 SEC 3 SEC Press button for 3 sec - release Press button for 3 sec - release Installer Menu is loading Ready for configuration If failed: Repeat the process to open Installer Menu Make sure that the distance between the devices is at least 3 m while loading the menu 9

OpenTherm 5. Configuration: OpenTherm Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Select OpenTherm D01 Select Heating Circuit HC01 Activate Hot Water Control Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Select Temperature Sensor TS Select Heating Circuit HC01 Activate Hot Water Control 10

OpenTherm 2 MIN No Extension Kit OpenTherm installation complete 1. Test the system 2. Hand over the registration card to the customer 2 MIN Extension Kit Present Select OpenTherm D01 Configuration download active after saving Installer Menu (up to 2 min) 11

1. Wiring: Vaillant ebus Wired Setup: Smart Thermostat is wired directly to the boiler Vaillant ebus Smart Thermostat Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 12

ebus Vaillant ebus Boiler Smart Thermostat MAX 36 V DC ebus Boiler Extension Kit 13

2. Connect Internet Bridge to Router Vaillant ebus If no free USB jack available - plug to power socket 14 Connect Internet Bridge to router Press pairing button until the LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge

3. Pair Extension Kit with Internet Bridge Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 3 SEC 2 MIN Blinking 4x short - pause -... Vaillant ebus Fast Blinking Press button for 3 sec until LED starts blinking fast Paired Blinking 2x short - pause -... If failed: Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 15

4. Pair Smart Thermostat with Internet Bridge Vaillant ebus 2 MIN 3 SEC Remove battery strip and press button Press button for 3 sec - release Pairing Paired If failed: Press the button to clear the error Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 16

Open Installer Menu Vaillant ebus 2 MIN 3 SEC 3 SEC Press button for 3 sec - release Press button for 3 sec - release Installer Menu is loading Ready for configuration If failed: Repeat the process to open Installer Menu Make sure that the distance between the devices is at least 3 m while loading the menu 17

5. Configuration: Vaillant ebus Wired Setup: Smart Thermostat is wired directly to the boiler Vaillant ebus Smart Thermostat Select ebus D05 or D07 D05 for systems with a calormatic VRC430/470 (VR81) D07 Standard Vaillant ebus Select Heating Circuit HC01 or HC02 Activate Hot Water Control (only for D07) Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Select Temperature Sensor TS Select Heating Circuit HC01 or HC02 Activate Hot Water Control (only for D07) 18

2 MIN No Extension Kit Vaillant ebus installation complete 1. Test the system 2. Hand over the registration card to the customer Vaillant ebus 2 MIN Extension Kit Present Select ebus D05 or D07 Configuration download active after saving Installer Menu (up to 2 min) 19

1. Wiring: Viessmann KM-Bus Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Viessmann KM-Bus Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 20

KM-Bus 1 2 Boiler Smart Thermostat MAX 36 V DC KM-Bus 1 2 Viessmann KM-Bus Boiler Extension Kit 21

2. Connect Internet Bridge to Router If no free USB jack available - plug to power socket Viessmann KM-Bus 22 Connect Internet Bridge to router Press pairing button until the LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge

3. Pair Extension Kit with Internet Bridge Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 3 SEC 2 MIN Blinking 4x short - pause -... Fast Blinking Press button for 3 sec until LED starts blinking fast Paired Viessmann KM-Bus Blinking 2x short - pause -... If failed: Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 23

4. Pair Smart Thermostat with Internet Bridge 2 MIN 3 SEC Viessmann KM-Bus Remove battery strip and press button Press button for 3 sec - release Pairing Paired If failed: Press the button to clear the error Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 24

Open Installer Menu 2 MIN 3 SEC 3 SEC Press button for 3 sec - release Press button for 3 sec - release Installer Menu is loading Ready for configuration Viessmann KM-Bus If failed: Repeat the process to open Installer Menu Make sure that the distance between the devices is at least 3 m while loading the menu 25

5.Configuration: Viessmann KM-Bus Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Select KM-Bus D37 Select Heating Circuit HC01 or HC02 No Hot Water Control Viessmann KM-Bus Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit Select Temperature Sensor TS Select Heating Circuit HC01 or HC02 No Hot Water Control 26

2 min No Extension Kit 2 MIN Viessmann KM-Bus Extension Kit Present Select KM-Bus D37 Configuration download active after saving Installer Menu (up to 2 min) 27

Viessmann KM-Bus 28

6. Heating System Settings For the heating circuit controlled by tado, set the same settings as for a Viessmann Vitotrol 200 remote control. Controller Heating System Settings 90: Time constant for calculating the adjusted outside temperature 12 Vitotronic 200 GW.. Vitotronic 300 GW.. Vitotronic 200 HO.. Vitotronic 200 KW.. Vitotronic 300 KW.. Vitotronic 200 KO.. A0: Remote Control b0: Room Temperature Hook-up b2: Room Influence Factor b5: Heating Circuit Pump Logic FA: Increase of the set flow temperature 0 1 (If 1 can not be selected, use 2) 3 64 (If 64 can not be selected, use 31) 5 (If 5 can not be selected, use 1) Viessmann KM-Bus Viessmann KM-Bus installation complete 1. Test the system 2. Hand over the registration card to the customer 29

1. Wiring: Worcester HT-Bus Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat Wireless Setup: Smart Thermostat installed wirelessly with receiver Worcester HT-Bus Smart Thermostat & Extension Kit 30

B B Boiler Smart Thermostat MAX 36 V DC B B Boiler Extension Kit Worcester HT-Bus 31

2. Connect Internet Bridge to Router If no free USB jack available - plug to power socket Worcester HT-Bus 32 Connect Internet Bridge to router Press pairing button until the LED blinks to activate pairing mode Pairing allows other devices to connect to the Internet Bridge

3. Pair Extension Kit with Internet Bridge Wireless Setup: Smart Thermostat installed wirelessly with receiver Smart Thermostat & Extension Kit 3 SEC 2 MIN Blinking 4x short - pause -... Fast Blinking Press button for 3 sec until LED starts blinking fast Paired Blinking 2x short - pause -... If failed: Restart pairing and make sure that the distance between the devices is at least 3 m while pairing Worcester HT-Bus 33

4. Pair Smart Thermostat with Internet Bridge 2 MIN 3 SEC Remove battery strip and press button Press button for 3 sec - release Pairing Paired Worcester HT-Bus If failed: Press the button to clear the error Restart pairing and make sure that the distance between the devices is at least 3 m while pairing 34

Open Installer Menu 2 MIN 3 SEC 3 SEC Press button for 3 sec - release Press button for 3 sec - release Installer Menu is loading Ready for configuration If failed: Repeat the process to open Installer Menu Make sure that the distance between the devices is at least 3 m while loading the menu Worcester HT-Bus 35

5. Wiring: Worcester HT-Bus Wired Setup: Smart Thermostat is wired directly to the boiler Smart Thermostat D17 for systems without an FW controller Select HT-Bus D17 or D18 D18 for systems with an FW controller (e.g. FW120) Select Heating Circuit HC01 or HC02 Activate Hot Water Control (only for D17) Wireless Setup: Smart Thermostat installed wirelessly with receiver Worcester HT-Bus Smart Thermostat & Extension Kit Select Temperature Sensor TS Select Heating Circuit HC01 or HC02 Activate Hot Water Control (only for D17) 36

2 MIN No Extension Kit 2 MIN Extension Kit Present Select HT-Bus D17 or D18 Configuration download active after saving Installer Menu (up to 2 min) Worcester HT-Bus 37

Worcester HT-Bus 38

6. Heating System Settings For the heating circuit controlled by tado, set the same settings as for a Worcester remote control. Controllers Heating System Settings Remote Control (heating circuit ) FB10 Room influence 50% FW 100 FW 120 FW 200 FW 500 Room influence enabled for levels Sensor used for room influence Mode selector (switch below the display) Comfort-Eco-Frost Sensor on FB10 (only when the FW controller is installed externally) Auto (FW100: clock symbol) Worcester HT-Bus installation complete 1. Test the system 2. Hand over the registration card to the customer Worcester HT-Bus 39