THERMOSTAT RETROFIT INSTRUCTIONS

Similar documents
KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

AVENGER HT THERMOSTAT RETROFIT INSTRUCTIONS

DRAIN WATER TEMPERING INSTALL

WARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.

WARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH

DRAIN WATER TEMPERING INSTALL

Installation Instructions

INSTALLATION INSTRUCTIONS

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Smart Water Heater Controller

Installation Instructions 30 French Door Built-in Wall Ovens

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Ceiling Fan Blade Arm Replacement

PWC 1800 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model PWC P/N man Copyright 2011 Vertex Water Products

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

Servo Cable Connector Crimping Guide

Summer Breeze Heater Service Manual

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

Click here for a labelled version of above

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Water Distiller Service Manual

DRAIN WATER TEMPERING INSTALL

Hanson LED C e i l i n g F a n

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Installation Instructions

Icemaker Accessory Kit

5800 Refrigerator Compressor Capacitor/Relay Kit

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Digital Control Module Replacement Manual

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

HEAT/ COOL/ DEFROST FORD THUNDERBIRD

Heat Exchanger Block Replacement Instructions

5COM52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5COM52XXD

No. Of Ignition Trials: No. Of Re-Ignition Attempts. Reset by interrupting power for 5.0 Seconds. Diagnostic Output. Re-Ignition Limit Exceeded

DISHWASHER INSTALLATION INSTRUCTIONS

Electric Dryer Installation Instructions

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

Installation Instructions

Product Support Bulletin

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TECHNICAL INSTRUCTIONS

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

21 TRV Blower Installation Instructions

BF5000NT BF5000 EF2604 SF2603 DF2603

5AZR56XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5AZR56XX

Service Manual. Model Number: BF362SD BF392SD. UL Part Number

Installation Instructions

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

INSTALLATION INSTRUCTIONS

Electric Dryer Installation Instructions

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHER PLASTIC TUB INSTRUCCIONES DE INSTALACIÓN LAVAVAJILLAS EMPOTRADA CON TINA PLÁSTICA

Service Manual. Model Number: Compact Fireplace DF203A DF2006. UL Part Number to 800

Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)

Heater Upgrade Instructions

I<enmore Elite. instructions dlnstallation. Installation Guide Instrucciones de Instalaci6n. English / Espafiol/Frangais

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

PWC-500/1000/1010/1500

INSTALLATION INSTRUCTIONS

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

3VNR52/42XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3VNR52XXD / 3VNR42XXD

Installation Instructions

IMPORTANT SAFETY INFORMATION

Commercial Electric Energy Saver Water Heater IMMERSION AND SURFACE MOUNTED THERMOSTAT MODELS

IMPORTANT SAFETY INFORMATION

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

HEATING CABLE RATINGS APPROVALS* Drexan Energy Systems, Inc. Kelowna, BC, Canada, V4V 1S5

PO Box 827 Hawley, MN (218) Fax (218)

EF3003 SF3003 DF3003

5GFR52XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 5GFR52XXD

CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

5LCM52XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : AC-552AL

FIREPLACE INSTALLATION

DELTA 1200/115 INSTALLATION, OPERATION, AND SERVICE MANUAL DELTA SERIES GLASSWASHER DISHMACHINES. Delta 1200/115 Manual S

TK-5001, Pneumatic Room Thermostats General Instructions GENERAL INFORMATION INSTALLATION

CEILING FAN OWNER'S MANUAL

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Owner s Manual FS-10/FreshSpa

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

W C. Table of Contents... 2 Table des matières... 25

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Service Manual 26 Self Trimming Fireplace Model Number: DF2608 DF2622 NBDF2608

Heater Inspection Guidelines

2 PREPARE THE OPENING

Service Manual 26 Self Trimming Fireplace Model Number: DF2608 DF2622 NBDF2608

Electric Space Heater

3SKYR56XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 3SKYR56(XXXXX)

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

LaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

Instructions: Changing Existing Downrod to Longer Downrod (sold separately)

Transcription:

With these instructions: You will remove the two existing thermostats from the dishmachine and will replace with a single new solid-state thermostat. TOOLS REQUIRED: Adjustable Wrench Philips Screwdriver Small bucket (approx. 1 gallon) 5/16 Nut Driver (high-limit switch) Wire Crimper for Insulated Terminals Step Stool Wire Stripper Needle-nose Pliers 3/8 Wrench (covers) 7/16 Wrench (probe) Control Screwdriver (for setting dip switches) 1 DISCONNECT ALL POWER TO THE DISHMACHINE BEFORE BEGINNING THIS PROCESS. LOCK OUT/TAG OUT IN ACCORDANCE WITH APPROPRIATE PROCEDURES AND CODES. 2 Lift up the panel and pull out gently to remove the front dress panel. 3 Remove both wash and rinse heater covers using a 3/8 wrench. 07610-004-22-11-B 1 of 12

CONTROL BOX SECTION Front 4 Using a phillips screwdriver, remove the top panel from the control box. Screw Holes 07610-004-22-11-B 2 of 12

5 Get the gray 6-conductor cable from the retrofit kit. Cut the orange and blue wires off at the edge of the gray sheath and discard those orange and blue segments. Notice that one end has all female terminals (this is the bottom portion) and the other end has one male and the three females (this is the top portion). The gray cable is to be routed from the top of the unit and trail down to the wash heater area. Pop out a black blank on the back of the control box and insert a new grommet from the retrofit kit. Insert the top portion of the gray cable (with the male and female terminals) through the grommet on the back of the control box (leave approx. 12 up in the control box). Run the gray cable down the back of the machine. Make sure to run the wire under the bracket and bar in the back so it is not hanging loose. Underneath the unit, route the gray cable between the wash tank and rinse booster. Once entering the wash tank heater housing area, route the gray cable over the high-limit switch. 6 In the control box, attach the red wire from the 6-conductor cable to the open tab on the L2 side of the Wash Motor Contactor (R3). 7 Locate and remove the two white wires in the single terminal on the Water Level Controller (WL) at the #1 position. Cut the terminal off of the two white wires. 07610-004-22-11-B 3 of 12

8 Trace the two white wires to the back of the control box. On the white wire that enters the wash conduit (from the front of the box, it is the conduit on the far right), strip and crimp a red female terminal onto the end and connect it back to the Water Level Controller at the #1 position where it was removed in Step 7. Rinse Conduit Wash Conduit 9 Trace the other white wire that was removed in Step 7 to the rinse conduit (from the front, it is the conduit to the immediate left of the wash conduit). Strip and crimp a red male terminal onto the white wire and then connect it to the white wire from the 6-conductor cable. 10 Locate the orange/white wire coming out of rinse conduit (same conduit as located in Step 9) and note it ends with a termination into the Rinse Heater Contactor (R1). Cut the orange/white wire approximately midway between the rinse conduit and the rinse heater contactor (R1). Strip and crimp a red male terminal on the end that goes to the rinse conduit and a red female on the end that goes to the rinse heater contactor. 07610-004-22-11-B 4 of 12

11 Connect the orange/white wire from the rinse conduit to the black wire from the 6-conductor cable. 12 Connect the orange/white wire from the rinse heater contactor to the brown wire from the 6-conductor cable. 13 Re-attach the control box cover with the phillips-head screws. RINSE BOOSTER SECTION 14 Find the thermostat on the rinse booster tank. Disconnect the orange/white and white wires from the rinse thermostat. 15 Cut ring terminals off both the orange/white and white wires. Strip wires and crimp each with red male terminals. 07610-004-22-11-B 5 of 12

! WARNING WARNING: Make sure machine has had time to let water in the booster tank cool. IF WATER IS NOT COOL, THE WATER TEMPERATURE COULD CAUSE SERIOUS BURNS. Place a bucket under the booster before the thermostat is removed to catch the water. If step 16 and 17 are done rapidly, minimal water will drain from the booster tank. 16 Prepare the new probe with the imperial brass fitting before removing the existing thermostat. Remove rinse thermostat. Use 7/16" wrench on fitting behind the thermostat. After fitting is loosened, pull out on the thermostat until the probe is removed from the wash tank. 17 Slide new ¼ Imperial brass fitting onto the new rinse probe that is included in the retrofit kit. Probe slides into the hole the same way the other came out. Tighten fitting on probe with a 7/16 wrench, making sure to leave ¼ of the probe exposed. 18 Connect the orange/white wire to the black/white wire from the rinse probe. Connect white wire to the black wire from the rinse probe. Use a zip-tie to straighten-up the wires. 19 Reattach the rinse cover with the 3/8 wrench. 07610-004-22-11-B 6 of 12

WASH TANK SECTION 20 Disconnect white/red wire from wash thermostat 21 Disconnect white/yellow wire from wash as well as from the high-limit switch. Remove wire thermostat. completely and discard. 22 Cut ring terminal off the white/yellow wire; strip and crimp a red female terminal to the white/yellow wire. 23! WARNING WARNING: Make sure that the drain stopper has been removed and that the wash tank is drained. THE WATER TEMPERATURE COULD CAUSE SERIOUS BURNS. Remove wash thermostat. Use 7/16 wrench on fitting behind the thermostat. After fitting is loosened, pull out on the thermostat until the probe is removed from the wash tank. Removed Thermostat Probe Imperial Brass Fitting 24 Slide new ¼ Imperial brass fitting onto the new wash probe that is included in the retrofit kit. Probe slides into the hole the same way the other came out. Tighten fitting on probe with a 7/16 wrench; make sure to leave ¼ of the probe exposed (a bracket fits over the probe in later steps, be sure that only 1/4" of the probe is exposed or the bracket will not fit correctly). 07610-004-22-11-B 7 of 12

25 Using a 5/16 nut driver, remove the two nuts securing the high-limit switch (nuts used later to reattach). Be careful with the thin tubing coiled behind the high-limit switch as you remove the switch and bracket from the studs. 26 Place new thermostat mounting bracket (from retrofit kit) onto the two studs where the high limit switch was removed. Reposition the coil of thin tubing on top of the mounting bracket and then fasten the high limit switch (with the same nuts) on top of the mounting bracket to the same studs where it was attached before. 27 Install the new thermostat onto the mounting bracket using the #6 32 screws provided in the kit. Make sure thermostat is configured so that the 5-pin connector is at the bottom. 07610-004-22-11-B 8 of 12

28 Connect the 4-pin and 5-pin connectors to the thermostat. 29 Connect the white/yellow wire removed earlier from the high-limit switch (Step 22) onto the white/yellow wire (slot 3) from the 4-pin connector. 30 Locate the white wire in slot 4 of the 4-pin connector. It has a blue female terminal and is attached to a white jumper. Plug that blue female terminal into the L1 tab on the thermostat. 31 Locate the white wire located in slot 2 of the 4-pin connector. It has a blue female terminal and is attached to the same jumper as described in step 30. Plug that blue female terminal into the top position (normally closed) on the high-limit switch. 32 Locate the white/red wire (slot 1) on the 4-pin connector. Connect that to the brown wire from the 6-conductor cable. 33 Connect the red wire from the 6-conductor cable to the L2 tab on the thermostat. 07610-004-22-11-B 9 of 12

34 Connect the black wire from the 6-conductor cable to the orange/white wire (slot 5) of the 5-pin connector. 35 Connect the white wire from the 6-conductor cable to the white wire (slot 4) of the 5-pin connector. 36 Connect the black wire from the probe to the black wire (slot 2) of the 5-pin connector. 37 Connect the black/white wire from the probe to the black/white wire (slot 1) of the 5-pin connector. 38 Using a zip-tie, coil up and secure the black and black/white wires from the 5-pin connector and probe. 07610-004-22-11-B 10 of 12

39 Adjust the settings for the thermostat as follows: set dip switch #1 (rinse) to the 1 position (1 set toward the "ON" position and 2, 3, 4 set away from the "ON" position). Set dip switch #2 (wash) to the 3 position (3 set toward the "ON" position and 1, 2, 4 set away from the "ON" position). Note: the switches can be moved with either a fingernail or control screwdriver through the protective film. Blue dials should all be set as indicated in the picture below (or mid-position between the two stops). 40 Replace standpipe and strainer. 41 Turn power on to the machine, turn the power switch to the ON position, and wait until tanks heat to setpoint. Run the unit three cycles and check rinse and wash temperature. 42 Adjust the 1st knob (left knob) until the desired rinse temperature is achieved (between 180 F and 195 F for the entire rinse cycle). Clockwise = increase temperature. Total adjustment is ±10 F. 43 Adjust the 2nd knob (right knob) until 150 F wash temperature is achieved. Clockwise = increase temperature. Total adjustment is ±10 F. 07610-004-22-11-B 11 of 12

44 Attach new wash heater cover. Adjust strain relief and tighten once in position. Replace front dress panel. 07610-004-22-11-B 12 of 12