SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

Similar documents
SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SN2003, SN2023, SN2004, SN2024

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

WF2613 Classic Corner Washfountain with 9" Deep Bowl

TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

SS-3N Express Lavatory System SS-Series

Express Lavatory System SS-Series

SS-1N Express Lavatory System SS-Series

SS-2N Express Lavatory System SS-Series

FL-2H, FL-2L Frequency Lavatory System FL-Series

AV30 Advocate Lavatory System AV-Series

AV60 Advocate Lavatory System AV-Series

Express Lavatory System MG-Series

Express Lavatory System MG-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

AV60 Advocate Lavatory System AV-Series

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

FL-1H, FL-1L Frequency Lavatory System FL-Series

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

HL45, HL80 Thermostatic High-Low Valves

AV90 Advocate Lavatory System AV-Series

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

Installation Instructions

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

AV60 Advocate Lavatory System AV-Series

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

LD-5010 OmniDeck with WashBar 5000 Series

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

Washfountain Application Guide

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

IMPORTANT. Wash Basin 1.0 Installation. Installation instructions for models:

ESS-2200 Double Station Scrub Sink. with Two Sensor Operated Gooseneck Spout. ESS-3200 Deluxe Double Station Scrub Sink

Installation Instructions

LVQD3 Verge with WashBar Technology LVQ-Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

LVSD2 Verge Wash Basin LVS-Series

LVQD1 Verge with WashBar Technology LVQ-Series

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

Model Z Sundara Reef Triple Basin Hand Washing System

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

CONTINENTAL METAL PRODUCTS. Stainless Steel Healthcare Equipment Meeting the Demands of the OR. Proudly Made in the USA for over 65 years

Durability within reach

Installation Instructions

School Solutions Ideabook

TMV45 & TMV80 Standard Thermostatic Mixing Valves

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Installation Instructions

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

Installation Instructions

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

Wall Mounted Shower Systems

SPEAKMAN SPEAKMAN SPECIFICATIONS

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

PRO SERIES IMPORTANT SAFETY INFORMATION

Installation Instructions

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

LA45 DISCONTINUED IMPORTANT!

Model Z Sundara Float Double Basin Hand Washing System

Installation Instructions

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

MERIDIAN MODEL# 3793

Distributed By: M&M Control Service, Inc SURFACE MOUNT SHOWER SYSTEMS

Geo Series KPF-1702 / KPF-1750 Make a Bold Statement in Your Kitchen

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

Installation LVQD1. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

Bobrick - Washroom Accessories. Conversion Chart

Moen Commercial Products Eco-Performance Product Guide

cygnet stainless Product Catalog toll free

ADA Compliant Freeze-Resistant Wall-Mount Fountain and Bottle Filler

LA60 DISCONTINUED IMPORTANT!

A. Section Joint Sealants: Seal fixtures to walls and floors.

Installation Instructions OBSOLETE

LAV FCO WCO NOTES: CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR MOUNT HEIGHTS AND SPECIAL MOUNTING INSTRUCTION AND LIMITATIONS.

Installation LVQD2. Table of Contents. Verge Lavatory System LVQ-Series with WashBar Technology

Transcription:

cupc Certified Available with Infrared, Air or TouchTime 54" Bowl Size Wall-Mounted or Floor-Mounted Standard and Juvenile Height with Air (hand), TouchTime Pushbutton and Piezo or Infrared are ADA/TAS Compliant Factory Tested and Shipped Pre-assembled Vandal Resistant and Easy to Clean Specifications Size and Capacity Accommodates three users at a time, using less water, energy and space than lavs equipped with conventional faucets. The sectional sprayhead module is controlled by a push button, which actuates an air valve (hand or foot control models), or a solenoid valve (TouchTime models) or by an infrared sensor-actuated solenoid valve. Flow Control/Rate Operating water pressure range is 20 80 psi. Flow regulators keep flow rate constant at all pressures. A flow restrictor keeps the flow rate at constant a.5 GPM under any pressure. Construction Bowl and Pedestal All exposed materials are type 304 stainless steel polished to a #4 finish. Bowl, pedestal, access panels, frame, foot control housing, support tube and sprayhead are heavy gauge stainless steel. Exposed fittings are chrome plated. Vandal Resistance Bowl and support tube are an integrally welded assembly, with the support tube welded to extruded flange from bowl. Sprayhead nozzles and push buttons/infrared sensors are secured to unit from inside the sprayhead module. Air valves/solenoid valves are safely concealed inside the washfountain. Access panels are removable only with a hex key. All supply and waste connections are concealed within the pedestal. Mounting Heights Sentry washfountains can be installed at standard or juvenile height. Floor-mounted models require mounting height selection. Wall-mounted units are simply installed at the desired height. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: Navigator thermostatic mixing valve, flexible stainless steel supply hoses and stops. Stop valves are 1/2" compression fitting female. Activation Types Air - Hold Open Foot Activation Each push button pneumatically actuates a hold-open air single temperature valve with slow closing upon release of foot pressure. Push button requires less than five pounds of pressure. Air - Hand Activation Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 10 seconds. Each push button activates one valve which, in turn, activates one station. Push button requires less than five pounds of pressure. Infrared Each of the stream formers is controlled by a separate slow-closing solenoid valve. Hands placed within the bowl are detected by an infrared sensor module, which activates a flow of tempered water from one spray nozzle. Shut-off is automatic after hands are removed from the detection area. The infrared sensor module uses two zone-focused infrared transmitting beams, having a detection area that does not exceed the bowl perimeter. The detection range projects 6 9 inches forward at a 30 angle to each side and reaches 15 below horizontal. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a low voltage transform as standard equipment: Page 1 of 7 9/18/2017 SN2013 (Infrared, Floor Mounted) SN2033 (Infrared, Wall Mounted) Solenoid 12VDC, 3/8" tube fitting. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Plug-In Adapter UL/CSA-listed 120VAC/12VDC plug-in adapter designed to plug into a standard GFCI protected electrical outlet. Location of plug-in adapter per local electrical code. TouchTime Each low-voltage pushbutton or piezo switch actuates a non-hold-open, slow closing antihammer solenoid valve that is timed from an electronic potted assembly. Each pushbutton activates one valve which, in turn, activates one station. TouchTime controls water flow at each station through the use of solid state, digital circuitry. Timing is factory set at a 15 second run time, but is field adjustable to pre-set time out periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Pushbutton requires less than five pounds of pressure. Code Compliance and Certifications UPC Approval Sentry Washfountains are Uniform Plumbing Code (UPC) approved through the International Association of Plumbing and Mechanical Officials (IAPMO). Barrier-Free (ADA Compliant) SN2013 (Air Valve Foot Control) Standard and juvenile height models with hand, TouchTime or infrared control are designed to comply with all ADA/TAS guidelines on reaches, clearances and operation. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Certified to NSF/ANSI 372

Models (Must select one) Model Size Stations Description SN2013 54" 3 Floor-Mounted* SN2033 54" 3 Wall-Mounted* Standard Selections (Must select one from each category) Drain Type (select one) A Off-line vent with supplies from below B Centrally rising vent with supplies from above H O Centrally rising vent with supplies from below Off-line vent with supplies from above Mounting Height Type (SN2013 only) (select one) STD Standard Pedestal Height JUV Juvenile Pedestal Height Activation Type (select one) AST4 Air - Hand Activation AST4-F Air - Hold Open Foot Activation** IRP Infrared Soap Dispenser Type (select one) LSD Two Integral Liquid Soap Dispensers NSD No Soap Dispenser Water Supply Type (select one) TMA Thermostatic Mixing Valve PBV Pressure Balance Mixing Valve TTPA TTPB TL TouchTime Pushbutton TouchTime Piezo Switch Tempered Line Supply Optional Selections Towel Dispenser Type CFTD (2) C-Fold, Multi-Fold Dispenser SFTD (2) Single-Fold Dispenser NONE Shroud Type (SN2013 Only) SH Stainless Steel Shroud (Conceals overhead plumbing) NONE No Shroud No Towel Dispenser * These models are ADA/TAS Compliant when mounted at standard or juvenile height dimensions with Infrared, TouchTime Pushbutton, TouchTime Piezo or Air (hand) Activation ** Non-cancelable, not-returnable. Dimensions - Sentry Wall-Mounted Infrared Activation Hand Activation (AST4 and TouchTime) 41-13/1* (1062) 42-9/1* (1081) Page 2 of 7 9/18/2017 Standard or juvenile height wall-mounted models with Infrared, TouchTime or hand control are ADA/TAS compliant.

Dimensions - Sentry Floor-Mounted Infrared Activation Hand Activation (AST4 and TouchTime) 41-13/1* (1062) 42-9/1* (1081) Foot Activation 8-1/8" (206) 3-1/1 (78) 3-11/1 (94) Page 3 of 7 9/18/2017 Standard or juvenile height floor-mounted models with Infrared, TouchTime or hand control are ADA/TAS compliant.

Rough-In Dimensions for Drain and Supplies Type A - Off-line vent with supplies from below or through wall. 1/2" nominal copper tubing Supplies 7-15/1 (202) 2-9/1 (65) Outline of Pedestal 12-1/1 18-7/1 Wall Stub Up 3" (76) 12-1/1 18-7/1 1/2" nominal copper tubing Supplies Stub Up 2-1/2" (64) Supplies Supplies and Drain Through Floor Floor Type B - Centrally rising vent with supplies from above. 1-1/2" NPT Drain Outline of Pedestal Wall 10-5/1 (262) Stub Up 3" (76) Also location of 1-1/2" vent from above. 10-5/1 (262) 1/2" Nominal supplies from above must be located on these centers to pass through washfountain shroud and sprayhead. Supplies from Above Vent from Above 12"* (321) Drain Floor * Subtract 4" (102) from this dimension for juvenile height. Drain Type A - Supplies below, vent off drain. P-Trap furnished by others. Page 4 of 7 9/18/2017 Drain Type B - Supplies above, centrally rising vent. P-Trap furnished. 1. Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines accordingly. 3. Unit with "A" drain and paper towel dispensers and/or a shroud should use "H" drain Rough-Ins.

Rough-In Dimensions for Drain and Supplies Type H - Centrally rising vent with supplies from below or through wall. Type O - Off-line vent with supplies from above. 1/2" nominal copper tubing Supplies 7-15/1 (202) 2-9/1 (65) Outline of Pedestal Wall 12-1/1 18-7/1 1-1/2" NPT Drain Through Floor Stub Up 3" (76) Also location of 1-1/2" vent from above. 12-1/1 Vent from Above 18-7/1 1/2" nominal copper tubing Supplies Stub Up 2-1/2" (64) Outline of Pedestal Wall 10-5/1 (262) Stub Up 3" (76) 10-5/1 (262) 1/2" Nominal supplies from above must be located on these centers to pass through washfountain shroud and sprayhead. Supplies from Above Supplies through Wall Supplies and Drain Floor 12"* (321) Drain Floor * Subtract 4" (102) from this dimension for juvenile height. Drain Type H - Supplies below, centrally rising vent. P-Trap furnished. Page 5 of 7 9/18/2017 Drain Type O - Supplies above, vent off drain. P-Trap furnished by others. 1. Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines accordingly. 3. Unit with "O" drain and paper towel dispensers and/or a shroud should use "B" drain for Rough-Ins.

Rough-In Dimensions for Bowl and Pedestal - Floor-Mounted Standard Mounting for SN2013 15-5/1 (389) 34-5/1 (872) 33-9/1 (852) 29-3/4" (756) 23" (584) 1 (425) 3-3/4" (95) 13-7/1 (341) Floor Juvenile Mounting for SN2013 15-5/1 (389) 30-5/1 (770) 29-9/1 25-3/4" (654) 19" (483) 14-3/4" (375) 3-3/4" (95) 13-11/1 (348) 12" (305) Page 6 of 7 9/18/2017 Floor

Rough-In Dimensions for Bowl and Pedestal - Wall-Mounted Standard Mounting for SN2033 Standard height models with Infrared or hand control are ADA compliant when mounted at standard height dimensions. 15-5/1 (389) 34-5/1 (872) 14-3/8" (365) 33-9/1 (852) 23-1/4" (591) 13-9/1 (344) 29-3/4" (756) 23" (584) 17-11/1 (449) Floor Juvenile Mounting for SN2033 15-5/1 (389) 30-5/1 (770) 29-9/1 25-3/4" (654) 19" (483) 14-3/8" (365) 13-9/1 (344) 19-1/4" 13-11/1 (348) Page 7 of 7 9/18/2017 Floor