TECHNICAL DATA. Factory Mutual Approval is pending for the system as a whole.

Similar documents
TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. 319a. January 27, 2012

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

TOTALPAC2 Integrated Fire Protection System

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

TECHNICAL DATA OBSOLETE

BERMAD Fire Protection

TECHNICAL DATA. model c-2

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

TECHNICAL DATA. Wet 26a. February 22, 2009

TotalPac X Single interlock SUREFIRE system

Deluge System. Pneumatic Release. Deluge System. Pneumatic Release

TotalPac X Firecycle III Preaction Double interlock system

Instructions for Installation, Operation, Care and Maintenance

Instructions for. Care and Maintenance 10 psi (0,7 bar) Pneumatic Supervising Pressure. Single Interlock

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

TotalPac 3 Firecyle III Deluge Remote controlled system

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Operation & Maintenance Manual

TotalPac 3 Double interlock Preaction, Electric/PneuLectric release Self-contained system

TotalPac 3 Wet pipe system c/w retard chamber

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH WET PILOT ACTUATION

Deluge & Preac tion Systems

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Worldwide Contacts.

N2 BLAST Datasheet SUREFIRE double interlock c/w N 2 Blast Nitrogen generating system Self contained unit

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

N2 BLAST Datasheet Preaction double interlock, Electric/Pneumatic c/w N 2 Blast Nitrogen generating system Self contained unit

SINGLE INTERLOCK, SUPERVISED PREACTION SYSTEM WITH ELECTRIC RELEASE

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

esfr dry pendent sprinkler Vk501 (k14.0)

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

N2 BLAST Datasheet Preaction double interlock, Electric/Pneulectric c/w N 2 Blast Nitrogen generating system Self contained unit

CONSTRUCTION REQUIREMENTS

TotalPac 3 Single interlock Firecyle III Preaction Self-contained system

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 227b - d

freedom residential concealed pendent sprinkler vk474 (K5.8)

Model DDX Deluge Valve

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

esfr pendent sprinkler vk510 (k25.2)

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

TECHNICAL DATA OBSOLETE

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

TECHNICAL DATA 3% AR-AFFF

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

esfr dry pendent sprinkler Vk502 (k14.0)

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Discontinued Product

TECHNICAL DATA. 31a. September 18, (DN25 - DN50)

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Environmental Health & Safety

quick response Sprinkler 105a October 25, 2010

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

TECHNICAL DATA OBSOLETE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

ECS Protector Dry SMART Vent - PSV-D (PSV-DE) Specifications

Model F1 LO K 8.0 (115 metric) Standard Response Sprinklers

Becoming an Expert on Dry-pipe, Preaction, and Deluge Sprinkler Systems

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

Gas Station & C Store SECTION CWM Job No

Series 759 FireLock Alarm Check Valve

ADDENDUM NO. 3 March 19, 2018

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

TotalPac 3 Deluge, Electric release Self-contained system

(Alarm Valve) & ' ( ()& * +,, & +-,. /0-

TECHNICAL DATA. Viking Technical Data may be found on Pip Cap: Brass UNS-C31400 or UNS-C31600

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

TECHNICAL DATA OBSOLETE

TotalPac 3 Non interlock Preaction, Electric release Self-Contained system

standard response elo upright sprinkler

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

SECTION PREACTION SPRINKLER SYSTEMS

TECHNICAL DATA. 2. LISTINGS AND APPROVALS NOTE: Viking Dry Vertical Sidewall Sprinklers are NOT listed or approved. Sprinkler 103a.

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

FireFlex DUAL Double Interlock, Self-contained system

Transcription:

September 8, 2000 Dry 132 a 1. PRODUCT NAME High Pressure Dry System Manufactured 2000-2. MANUFACTURER The Viking Corporation 210 N Industrial Park Road Hastings MI 49058 U.S.A. Telephone: (616) 945-9501 (877) 384-5464 Fax Number: (616) 945-9599 email: techsvcs@vikingcorp.com 3. SYSTEM DESCRIPTION Viking High Pressure (HP ) dry systems utilize a Viking Model E deluge valve to control the water supply to system piping equipped with closed sprinklers. The system piping is pressurized with compressed air or nitrogen. A riser check valve is required to isolate the system air pressure from the outlet chamber of the deluge valve. High pressure dry systems are commonly used where sprinkler system supply pressures are above 175 psi (12 Bar), small systems where anti-freeze solutions are undesirable and smaller conventional dry pipe valves are not available. 4. LISTINGS AND APPROVALS All the devices utilized in the Viking HP dry system are: UL Listed and FM Approved Size Valve Deluge Valve Model No. 1 1-1/2" E-3 2" E-1 System Check Valve Factory Mutual Approval is pending for the system as a whole. 5. SYSTEM OPERATION (Refer to Figure 1) A. In the SET position: System water supply pressure enters the priming chamber of the Deluge valve (A.1) through the ¼ (8 mm) priming line which includes a normally open priming valve (B.1), strainer (B.2), restricted orifice (B.3), check valve (B.4), prime shut-off valve (B.10). In the SET position, the water supply pressure is trapped in the priming chamber by check valve (B.4), and Anti-flood device (F.1). The Anti-flood device (F.1) is held closed by air pressure maintained on the system riser. Air pressure is isolated from the deluge valve outlet on 3 systems and above by a Viking Easy Riser soft seat check valve. The pressure in the priming chamber holds the Deluge Valve (A.1) clapper closed, keeping the outlet chamber and system piping dry. B. In Fire Conditions: In fire conditions, when a Viking sprinkler head operates, pressure in the system piping escapes causing alarms COMPONENTS OF VALVE SYSTEM ASSEMBLY Cold Trim Assembly 1 controlled by Air Supervisory Switch (E.3) to activate and Anti-flood device (F.1) to open. When Anti-flood device (F.1) opens, pressure is released from the priming chamber faster than it is supplied through restricted orifice (B.3). The Deluge Valve (A.1) clapper opens to allow water to flow into the system piping and alarm devices, causing the Water Motor Alarm (C.2) and water flow alarms connected to the Alarm Pressure Switch (C.1) to activate. Water will flow from any open sprinklers on the system. When the deluge valve operates, the sensing end of the PSOV (B.10) is pressurized closed, closing the supply of priming water pressure to the priming chamber. When the PSOV (B.10) operates, it positively shuts off the supply of water to the priming chamber to prevent the deluge valve from resetting. Downstream of the discharge outlet, a check valve is installed to isolate the discharge outlet from system air pressure. When the water from the discharge outlet passes by the check valve, it will enter to air connection to the system riser. To eliminate water from entering Part No. 1 Galv. Brass Galv. Brass Galv. Brass Included in Release Trim 10902 10903 10692 10859 10960 10961 Included in Release Trim 10904 10905 10693 10860 10962 10963 3" E-1 F-1 10906 10907 10694 10861 10964 10965 4" E-1 F-1 10908 10909 10695 10862 10966 10967 6" E-1 F-1 10910 10911 10696 10863 10968 10969 1 To order a complete HP DrySystem, order the Deluge Valve, EZ Riser Check Valve w/trim and Cold Trim Assembly together. 2 Release Trim assemblies include M odel B-1Anti-Flood Device, M odel B Float Check Tee Assembly and all piping to connect to system check valve. Table 1 Cold Trim Assembly includes the items indicated below. Base Trim Release Trim 2 Form F_010300 Replaces page 132a-g dated May 1, 2000. Updated Components of Valve System Assembly. System Check Valve must be ordered separately. Updated drawings to show inlet for air supply.

Dry 132 b September 8, 2000 the Viking HP dry system trim, a Model A-1 Float Check Valve (D.5) is installed between the anti-flood device (F.1) and the system riser. The Model A-1 Float Check Valve (D.5) allows air to pass from the system riser to the Anti-flood Device (F.1) to set the system, when the system discharges, the Model A-1 Float Check Valve (D.5) closes when water flows to the inlet side of the device, protecting the Anti-flood Device (F.1) from water pressure on its inlet end protecting the deluge valve from re-setting. C. Trouble Conditions: In the event of an air supply failure and slow leakage of air from the system piping, alarms connected to the Air Supervisory Switch (E.3) will signal a low air pressure condition. Failure to restore air supply to the system will result in operation of the Anti-flood Device (F.1) and the Deluge Valve (A.1) will open. Similarly, if the system piping is damaged due to mechanical damage, the Anti-Flood Device (F.1) will operate and the Deluge Valve (A.1) will open. Water will flow from any open sprinklers or piping on the system. Water Motor Alarm (C.2) and alarms connected to Alarm Pressure Switch (C.1) will activate. D. Manual Operation: Any time the handle inside the Emergency Release (B.11) is pulled, pressure is released from the priming chamber; the Deluge Valve (A.1) will open. Water will flow into the system piping and from any open sprinklers on the system. Alarm devices (C.1 and C.2) will operate. 6. INSTALLATION Refer to current Viking Technical Data describing individual components of the Viking HP Dry System. Technical Data describing the Viking Deluge Valve, and other system components are packed with product and in the Viking Engineering Design Data book. Also, refer to applicable installation standards, codes, and Authorities Having Jurisdiction. A. Important Settings: 1. Provide a minimum or maximum pneumatic air pressure to Anti-flood Device(F.1) as shown in Table 2 for system water pressures to 250 PSI (17,2 BAR) maximum. a. Set release system Air Pressure Supervisory Switches (E..3) to activate at 5 PSI less than the set pneumatic supervisory air pressure on pressure drop, as shown in Table 2. b. Air Supervisory Switch (E.3) should be wired to activate an alarm to signal a low air pressure condition. Activation of an alarm to signal a high pressure condition may be installed. Refer to applicable installation standards and Authority Having Jurisdiction. 2. Alarm Pressure Switch (C.1) should activate when pressurized to 4 to 8 PSI (27 to 55 kpa) on pressure rise. Alarm Pressure Switch (C.1) should be wired to activate the water flow alarm. B. Air Supply Design: The air supply compressor should be sized to establish total required air pressure in 30 minutes. The air supply must be regulated, restricted, and maintained automatically. The air supply must be regulated to maintain the pressure desired in the system piping. Pressure settings other than the pressure settings recommended in Table Water Pressure Air Pressure, PSIG PSIG Max. Minimum Maximum 50 15 25 75 20 30 100 25 35 150 35 45 175 40 50 200 50 55 250 55 60 Table 2 2, may affect operation of the system. The air supply must be restricted to ensure that the automatic air supply cannot replace air as fast as it escapes when a sprinkler on the system operates. It is a required practice to provide an Inspectors Test Connection on the system piping. The Inspectors Test Connection should be equipped with a shut-off valve (normally closed) capable of being opened to simulate the opening of a sprinkler on the system. Locate the connection and the valve at the highest, most demanding, location of the system piping. Test connections, provided on dry pipe systems, should terminate in an orifice equal to the smallest orifice sprinkler on the system piping. The Inspectors Test Connection may be used to verify that the automatic air supply cannot replace air as fast as it escapes when a releasing device operates. Refer to paragraph 7C Inspections and Tests.

September 8, 2000 Dry 132 c 7. EMERGENCY INSTRUCTIONS (Refer to figure 1) A. To Take System Out of Service: Warning: Placing a control valve or detection system out of service may eliminate the Fire Protection capabilities of the system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a Fire Patrol in the affected areas. After a fire, verify that the fire is OUT and that placing the system out of service has been authorized by the appropriate Authority Having Jurisdiction. 1. Close Water Supply Valve (D.1). 2. Open auxiliary drain (B.6). 3. Silence Alarms (optional) a. To silence electric alarms controlled by pressure switch (C.1) and to silence Water Motor alarm (C.2). Close Alarm Shut-off Valve (B.9). Note: Electric alarms controlled in the ½ (15mm) NPT connection for a Non-interubtable Alarm Pressure Switch cannot be shut off until the Deluge Valve (A.1) is reset or taken out of service. 4. Shut off the air supply. 5. Close Priming Valve (B.1). Sprinkler systems that have been subjected to a fire must be returned to service as soon as possible. The entire system must be inspected for damage, and repaired or replaced as necessary. 6. Replace any sprinkler heads that have operated. 7. Perform all maintenance procedures recommended in Technical Data describing individual components of the system that has operated. 8. Return the system to service as soon as possible. Refer to b: PLACING THE SYSTEM IN SERVICE. B. Placing the System In Service 1. Verify that the system has been properly drained. Auxiliary Drain (B.6) should be open. Verify that the Emergency Release (B.11) is closed. Priming valve (B.1) should be closed. Open sprinkler system main drain (D.3). Once sprinkler piping is drained, close system drain (D.3). 2. Restore pneumatic pressure to the system piping. Maintain as required to the Anti-flood Device (F.1). Refer to item 6A. Important Settings. 3. Open Priming Valve (B.1). Water pressure should be present on Priming Water Gauge (B.12). 4. Open Flow Test Valve (B.15). 5. Partially open Main Water Supply Control Valve (D.1). 6. When full flow develops from Flow Test Valve (B.15), close the Flow Test Valve (B.15). 7. Close Auxiliary Drain (B.6). 8. Fully open and secure the Main Water Supply Control Valve (D.1). 9. Verify that the Alarm Shut-off Valve (B.9) is open and that all other valves are in their normal operating position. 10. Depress the plunger of Drip Check (B.7). No water should flow from the Drip Check (B.7) when the plunger is pushed. C. Inspections and Tests It is imperative that the system be inspected and tested on a regular basis. Refer to Inspections and Tests recommended in current Viking Technical Data describing individual components of the Viking Deluge System used. The frequency of the inspections may vary due to contaminated water supplies, corrosive water supplies, corrosive atmospheres as well as the condition of the air supply system. For minimum maintenance and inspection requirements, refer to the National Fire Protection Association Pamphlet 25 for Inspection, Testing, and Maintenance of Water Based Systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection requirements which must be followed. Warning: Any system maintenance which involves placing a control valve or detection system out of service may eliminate the fire protection capabilities of that system. Prior to proceeding, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected areas. D. To test Sprinkler system Low Air Alarm. 1. To prevent operation of the Deluge Valve and system piping filling with water during the test, Close Main Water Supply Control Valve (D.1). 2. Fully open Inspectors Test Valve to simulate operation of a sprinkler head. 3. Verify that low air alarms operate within an acceptable time period and continue without interruption. 4. Close the Inspectors Test Valve. 5. Close Priming Valve (B.1). 6. Establish recommended pneumatic pressure to be

Dry 132 d September 8, 2000 maintained on system piping. Refer to paragraph 6: INSTALLATION. 7. Alarms should stop. 8. Open Priming Valve (B.1). When testing is complete, return the system to service following steps 1 through 8 below. Caution, this procedure applies to only when done in conjunction with Low Air Alarm testing described above. 1. Verify that the pressure indicated on Priming Pressure Water Gage (B.12) indicates that the priming chamber is pressurized with system Water Supply Pressure. Figure 1 2. Depress the plunger of Drip Check (B.7). No water should flow from the Drip Check when the plunger is pushed. 3. Open Flow Test Valve (B.15). 4. Partially open Main Water Supply Control Valve (D.1). 5. When full flow develops from Flow Test Valve (B.15), close the Flow Test Valve. 6. Fully open and secure the Main Water Supply Control Valve. 7. Verify that the Alarm Shut-off Valve (B.9) is open, that Priming Valve (B.1) is open, and that all other valves are in their normal operating position. 8. Depress the plunger of Drip Check (B.7). No water should flow from the Drip Check when plunger is pushed. E. Maintenance Notice: The owner is responsible for maintaining the fire protection system and devices in proper operating condition. Refer to MAINTENANCE INSTRUCTIONS provided in current Viking Technical Data describing individual components of the Viking Dry System used.

September 8, 2000 Dry 132 e FIGURE 2 1-1/2 DRY SYSTEM

Dry 132 f September 8, 2000 FIGURE 3 2 DRY SYSTEM

September 8, 2000 Dry 132 g FIGURE 4 3, 4 & 6 DRY SYSTEM

THIS PAGE IN TEN TIONALLY LEFT BLANK Form F_010300 Replaces page 132a-g dated May 1, 2000. Updated Components of Valve System Assembly. System Check Valve must be ordered separately. Updated drawings to show inlet for air supply.