SWIMMING POOL HEAT PUMPS

Similar documents
QUANTUM. Reliable solar hot water, whenever you want it

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

Pool heating, efficiently

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps

ASTRALPOOL HEAT PUMP CATALOGUE

ASTRALPOOL HEAT PUMP CATALOGUE

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Thermodynamics: Homework A Set 7 Jennifer West (2004)

MODULAR CHILLER. R410a R22

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

THE CHEAPEST WAY TO HEAT YOUR WATER

Refrigerator and Heat Pump Objectives


AQUATECH Heat Pump. Temperature Control System for Swimming Pools

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Heat Pumps COMFORT NEED IT. When You

Chapter 9. Refrigeration and Liquefaction

AQUASNAP JUNIOR 30RHV

Hot Water Heating Systems

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Pressure Enthalpy Charts

Modular Air Cooled Scroll Chillers

Homework Chapter2. Homework Chapter3

ULTRA SERIES CIRCULATING AIR SOURSE HEAT PUMP WATER HEATER

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Week 9. Refrigeration Cycles I. GENESYS Laboratory

AIR TO WATER HEAT PUMPS SPECSHEET

HVAC Systems What the Rater Needs to Know in the Field CALCS-PLUS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

S-Therm Air to Water Heat Pumps

Water Chiller Climate Control from. Integrated FREE Hot Water Heating

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

AIRLINE - commercial heat pumps Air / water heat pump for heating, cooling and DHW production - commercial use

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Call or visit solarshop.com.au

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Technical information Master

50A KP 70A KP 90A KP 120A KP 150A KP 210A

PRODUCT GUIDE

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Air Conditioning Clinic. Absorption Water Chillers One of the Equipment Series TRG-TRC011-EN

Commercial High-Efficiency Condensing Units

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

CLIMEXEL - M.P.I. MITSUBISHI POWER INVERTER

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

EN aquatech.piovan.com

Heat pump systems and Chillers

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Technical data LA 28TBS

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

Product Line Introduction. Karl Zhang Technical support engineer

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Commercial COMMERCIAL DUCTED. The trusted commercial solution engineered to exceed Australian Standards. That s better. That s Actron.

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Technical data LA 60TUR+

Air to Water Heat Pump Utilising Natural Refrigerant C02

Inverter Hot Water Heat Pumps

Midea VFD Centrifugal Chiller Technology

13 SEER CONDENSING UNITS & AIR HANDLERS

Application Engineering

SWIMMING POOL HEAT PUMP Owners Manual

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Multi Inverter Air Conditioning Condensing Units - Summary

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Modular Air-cooled Scroll Chiller

DVU-HP. Integrated Reversible Heat Pump System

ROOFTOP PACKAGED AIR CONDITIONERS

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

Air Cooled Chillers & Heat Pumps WinPACK HE-A

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Technical data LA 9S-TU

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Mini unitary chiller. Mini unitary chiller

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

CO2 TRANSCRITICAL BOOSTER SYSTEMS

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Sweden s leading air source heat pump

V D M. Zwembaden. Max: +32 (0)495/

Heat Pumps for Swimming Pools extend the season or swim year round

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

Technical description. Atec.

160 Line. 1 Door Undercounter Refrigerator (+2/+10) - UK Plug. 160 Line

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Transcription:

WHAT IS A POOL HEAT PUMP? Swimming pool heat pumps extract the heat stored in the ambient air and transfer it to water. It increases the water temperature to reach the desired level. Comparatively, it operates like a reverse refrigerator to pump the heat into the water and discharge the cooler air back into the ambient air. A correctly sized swimming pool heat pump can ensure constant, comfortable swimming pool temperatures all year round. This robust energy-efficient technology could dramatically reduce your utility bills up to 80%. The key point about the amazing heat pump efficiency is that unlike electric heating coils and gas heaters, a heat pump does not produce thermal energy but simply moves thermal energy from the surrounding air to a hot reservoir. Heat pumps have been proven to be the most efficient water heating technology available for the last 30 years consistently delivering 3-5 times the efficiency of conventional water heating technologies.

HOW DOES A POOL HEAT PUMP WORK? 1. Unlike a traditional electric resistive heater, a heat pump doesn t use electricity to heat the water directly, instead it uses electrical power to run a compressor to transfer the heat from the ambient air into the water through a reverse Carnot cycle, it applies the same principle as a refrigerator but in reverse. 2. The low temperature and low-pressure refrigerant pass through the evaporator since the refrigerant R410A has a boiling point of -48.5 C. It can therefore still absorb the heat from the ambient air even in a cold environment and become the low pressure, low-temperature superheated vapor. 3. The compressor then utilizes electricity to draw in refrigerant and discharge high temperature, high-pressure superheated vapor to the water heat exchanger (condenser) where the heat exchange is taking place and water is therefore heated. 4. With the condenser, the expansion valve turns high pressure, sub-cooled liquid released from the compressor into the low pressure, low temperature saturated liquid. The refrigerant will perpetually circulate until the water reaches the set point.

Ari can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 7.8 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Side Discharge Working Ambient -5 C Min./Recommended Water Flow 1.5 m³/hour 2.3 m³/hour Water Loss / Max. Water 20.4 kpa 1 MPag Heating Output / Power Input 7.8 kw 1.58 kw Coefficient of Performance (COP) 4.94 Starting / Normal Running 37.5 A 7.5 A Maximum 12 A Input Voltage / Frequency / Phase 220 240 V 50 Hz 1 phase 282 x 550 x 935 mm Net Weight / Gross Weight 50 Kg 65 Kg DN40 BSP 1 ½ Female 55, 44, 34 db(a) Outdoor d IPX4 Compressor Type/Band Rotary Mitsubishi Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.

Air can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 14 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Side Discharge Working Ambient -5 C Min./Recommended Water Flow 1.5 m³/hour 4 m³/hour Water Loss / Max. Water 32.5 kpa 1 MPag Heating Output / Power Input 14 kw 2.61 kw Coefficient of Performance (COP) 5.35 Starting / Normal Running 62 A 12.5 A Maximum 12 A Input Voltage / Frequency / Phase 220 240 V 50 Hz 1 phase 1116 x425 x 686 mm Net Weight / Gross Weight 90 Kg 110Kg DN40 BSP 1 ½ Female 55, 44, 32 db(a) Outdoor d IPX4 Compressor Type/Band Scroll Sanyo Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.

Air can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 25 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Top Discharge Working Ambient -5 C Min./Recommended Water Flow 1.5 m³/hour 7 m³/hour Water Loss / Max. Water 37.2 kpa 1 MPag Heating Output / Power Input 25 kw 4.8 kw Coefficient of Performance (COP) 5.47 Starting / Normal Running 39.5 A 22 A Maximum 34 A Input Voltage / Frequency / Phase 220 V 50 Hz 1 phase 752 x 691 x 959 mm Net Weight / Gross Weight 124 Kg 146 Kg DN40 BSP 1 ½ Female 54 db(a) Outdoor d IPX4 Compressor Type/Band Rotary Toshiba Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.

Air can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 26 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Top Discharge Working Ambient -5 C Min./Recommended Water Flow 1.5 m³/hour 7 m³/hour Water Loss / Max. Water 37.2 kpa 1 MPag Heating Output / Power Input 26 kw 4.75 kw Coefficient of Performance (COP) 5.47 Starting / Normal Running 39.5 A 8.39 A Maximum 14 A Input Voltage / Frequency / Phase 380 415 V 50 Hz 3 phase 752 x 691 x 959 mm Net Weight / Gross Weight 124 Kg 146 Kg DN40 BSP 1 ½ Female 55, 44, 34 db(a) Outdoor d IPX4 Compressor Type/Band Scroll Sanyo Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.

Air can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 45 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Top Discharge Working Ambient -5 C Min./Recommended Water Flow 1.5 m³/hour 14 m³/hour Water Loss / Max. Water 20 kpa 1 MPag Heating Output / Power Input 45 kw 7.56 kw Coefficient of Performance (COP) 5.53 Starting / Normal Running 88.0 A 13.6 A Maximum 21.8 A Input Voltage / Frequency / Phase 380 415 V 50 Hz 3 phase 1450 x 702 x 1060 mm Net Weight / Gross Weight 249 Kg 293 Kg DN50 BSP 2 Female 55, 44, 34 db(a) Outdoor d IPX4 Compressor Type/Band Scroll x 2 Sanyo Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.

Air can be used to heat outdoor and indoor swimming pools and considerably extend the swimming season in an economical and environmentally-friendly manner. 100 KW Swimming Pool Heat Pump HEIZER Swimming Pool Heat Pumps are an energy efficient way to heat and maintain comfortable swimming pool temperatures. The heat pump heats chlorinated or salt water pools at an efficiency greater than 5 times that of conventional electric or gas heaters. Top Discharge Working Ambient -5 C Min./Recommended Water Flow 25 m³/hour 35 m³/hour Water Loss / Max. Water 30 kpa 1 MPag Heating Output / Power Input 100 kw 20.6 kw Coefficient of Performance (COP) 4.85 Starting / Normal Running 160 A 40.6 A Maximum 54 A Input Voltage / Frequency / Phase 380 415 V 50 Hz 3 phase 2000 x 900 x 1880 mm Net Weight / Gross Weight 530 Kg 620 Kg DN50 BSP 2 Female 57 db(a) Outdoor d IPX4 Compressor Type/Band Scroll x 2 Sanyo Multifunction LCD based on ambient air temperature 24 C (DB) / 19 C (WB), inlet water temperature. that all relevant values are calculated at, and default heat pump setting.