Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

Similar documents
new HYGIENE AND COMFORT FOR HOSPITALS AND PUBLIC BUILDINGS HYGIENIC AIR HANDLING UNITS HYGIENIC AHU N o : Range: AmberAir

SMART WAY TO HANDLE THE AIR

NEW SECTION: ROTARY HEAT EXCHANGER WITH A HEAT PUMP Effective and smart!

SMART WAY TO HANDLE THE AIR

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Air Handling Units. Geniox. Quick guide

AIR HANDLING UNITS ver B

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

LIBERTY COMPOSITE AIR HANDLING UNITS TYPE LIBERTY > SWIMMING POOLS. AHU No Liberty AIR HANDLING UNITS

air handling units Issue 2016 ver. A

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Air Handling Units. Quick Guide to Danvent DV

Compact. Efficient. TROX.

AIR HANDLING UNITS MANDÍK

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

The power of ventilation

Air Handling Units. Geniox. Catalogue

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Danvent DV 190 and 240

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Geniox. The next generation of air handling units

Air Handling Units. Geniox. Catalogue

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

SWIMMING POOL AIR MANAGEMENT DanX

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

VERSO Air Handling Units

Energy efficient ventilation equipment

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

Compact. Efficient. TROX.

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Danvent DV. Modular Air Handling Unit

The ultimate in air handling units: directly and indirectly fired

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Modular air-handling units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

TECHNICAL INFORMATION DanX XD & DanX HP Swimming pool air management

Package Hygienic Air Handling Units. PHK Series

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Air handling units. Technical Catalogue

TECHNICAL INFORMATION DanX Swimming Pool Air Management

The ultimate in air handling units: directly and indirectly fired

Air distribution for clean rooms. Clever and flexible.

air handling units AT THE LEADING EDGE OF AIR FLOW

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R

Movement by Perfection. The Royal League in ventilation, control and drive technology. Fans for agriculture. Durable, efficient, well designed

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

Systemair product news - Fans NEWS

KOMFORT EC DB Suspended heat recovery air handling units

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

VERSO Air Handling Units

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

13 HYGENIC AIR HANDLING UNITS

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

The ultimate in air handling units: directly and indirectly fired

R E P O R T D I N E N

RoofVent Design Handbook

COMMERCIAL LINE DUPLEX ROTO

Energy efficient ventilation equipment

Pool dehumidification. Airpool+

Homepage > Prodotti > Sistemi di ventilazione decentralizzata > Dispositivi verticali > Type FSL-V-ZUS. Type FSL-V-ZUS

SIMPLICITY FULL MODULARITY?

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Air Handling Units. Danvent DV 190 and

The ultimate in air handling units: directly and indirectly fired

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Easdale International INFINITY

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

Air Treatment for Swimming Pools

Air Handling Units. T F E.

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s)

AIR HANDLING UNITS FROM 600 TO m3/h

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

We simplify construction

TKM 50 HE. High efficiency in air treatment

SIMPLICITY OR FULL MODULARITY?

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

TELLUS. Complete HVAC substation for air handling, cooling, heating and hot tap water. Main benefits. General

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DAIKIN Air Handling Unit Modular

Dual certification! Air handling units for potentially explosive atmospheres

Compact Gas Conditioning MAK10

INDUSTRIAL CLEANING SYSTEMS & LOGISTICS OFFERING SMART CLEANING SOLUTIONS FOR EVERY CHALLENGE

Enjoy the Delighting Comfort Brought by High Air Quality

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Transcription:

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF PERSONALIZED CORROSION-RESISTANT SAVING

AmberAir Pool FOR A COMFORTABLE MICROCLIMATE AT A SWIMMING POOL AmberAir Pool units have been designed to create an ideal microclimate for indoor swimming pool premises. Depending on settings and air parameters, smart control automatically ensures air quality parameters by extracting excessive humidity, supplying fresh air, returning most of the extracted air heat, and maintaining the required temperature of supplied air. The internal components and surfaces are made of corrosion-resistant materials thus ensuring perfect hygiene. WHY AmberAir Pool? User-friendly control: SALDA AIR mobile app. Highly durable, hermetic casing SW50+ characteristic of the highest thermal resistance on the market (D1, L1, F9, T2, TB1) (also available 3 alternative casing options). Developed in accordance with the highest requirements of the German Standard VDI 2089. Customized solution: the facilities may be arranged by choosing from a variety of available component options. Reliable: the selection program and the facilities have been certified by Eurovent Certita Certification. Air flows from 1950 m 3 /h to 40000 m 3 /h air flow

MAINTAINED COMFORT WITH LOW ENERGY AND MAINTENANCE COSTS In accordance with Part 1 of VDI 2089, a temperature of 30-34 0 C and relative air humidity of 40%-64% must be maintained at the swimming pool premises. Since the required air temperature is almost always higher than the outdoor temperature, heat return as well as dehumidification and recirculation of the present air are required for optimum use of energy resources. Counter-flow plate heat exchanger returns up to 95% of the exhaust air heat, meanwhile simultaneous operation of heat pump results in maximum efficiency of even up to 140%. Whereas steady recirculation is maintained at the swimming pool premises, we offer choosing the latest low-energy EC and PM fans. The smart control system selects an optimum ventilation mode based on external parameters in this way saving up to 30% of electricity and thermal energy. The unit is easy to maintain and the components can be removed easily for cleaning or replacement, thus minimizing maintenance and servicing costs. Before choosing the unit, you are welcome to check its energy consumption on a free LCC module, which is available on selection program VentMaster! AVAILABLE SIZES: Height [mm] 2600 45 mm insulation 16KR 2010 13KR 15KR 1700 12KR 14KR 1400 10KR 11KR 1130 1100 7KR 8KR 9KR 860 775 3KR 5KR 4KR 6KR 560 490 2KR 1KR 0 910 1060 1080 1360 1660 1970 2010 2160 2600 Width [mm]

CORROSION-RESISTANT DESIGN AND AVAILABLE OPTIONS Mixing section Pocket filters of class M5/F7/F9 TECHNICAL CHARACTERISTICS OF CASING SW50+* Model Casing strength class Casing air leakage class at -400 Pa Casing air leakage class at +700 Pa Filter bypass leakage class Thermal transmittance class Thermal bridging factor class SW50+ D1(M) L1(M) L1(M) F9(M) T2 TB1 * - It is planned to introduce additional profiles from mid QII 2018: with mineral wool or with PU insulation and with or without a thermal bridge.

Counter-flow (efficiency up to 95%) or cross-flow (efficiency up to 75%) heat exchanger (option with a heat pump for dehumidification/heating) AC, EC, or PM fans Pocket filters of class M5/F7/F9 Mixing section Integrated optional water heater CHARACTERISTICS OF THE DESIGN Structural components are made of AZ185 corrosion resistance class C4; Internal panel walls are made of AZ185 or AISI 304; Drip trays are made of AISI 304 or AISI 316; Components (heat exchanger, heating-cooling elements, compressor) are made of aluminium or covered with epoxy coating; Dampers are equipped with actuators designed for swimming pools (IP 66); Casing profile is made of anodised aluminium; Control unit installed on the door in order to protect components from corrosion.

USER-FRIENDLY CONTROL MODES Good microclimate at swimming pool premises is ensured by using automatic programs, which are activated depending on input and environment parameters. PROGRAMS FOR AN AIR HANDLING UNIT WITHOUT A HEAT PUMP: Program P1 Flow all air is taken only from the inside, only one (supply) fan works, 30% of the flow. The Program is used at night time, when no people are at the swimming pool. There is no need for supplying the air from the outside, when there are no people at the swimming pool, i.e. no energy is wasted on heating. The air is extracted from the swimming pool, if necessary, it is heated, and returned to the swimming pool. Operation of this Program requires minimum energy consumption in order to make sure that air would not set in at the swimming pool premises and a constant temperature would be maintained. Program P2 Flow from 30% to 100% of air from the outside. The Program is used during the day, when the humidity level is high, at the swimming pool premises, when people are at the swimming pool. Up to 100% of air may be supplied from the outside based on the required level of dehumidification (the air becomes drier, if more air is supplied from the outside. This applies when the temperature is under +25 C). The air from the outside mixes with a portion of the air indoors, it is pre-heated and dehumidified in the heat exchanger and additionally heated in the heater. This Program ensures efficient reduction of humidity. Program P3 Flow 30% of air from the outside. The Program is used during the day, when people are at the swimming pool. The air from the outside mixes with a portion of the air indoors, it is pre-heated and dehumidified in the heat exchanger and additionally heated in the heater. This is the main mode which ensures a good level of dehumidification, sufficient amount of fresh air (based on the standards of hygiene) and a part of energy is saved. Program P4 Flow 100% of air from the outside, through the by-pass. The Program is used in summer, during the day, when people are at the swimming pool. No heat exchange takes place because of the small temperature difference outdoors and indoors, thus the entire flow goes through the by-pass. Program P5 Flow cyclically: 30% of air from the outside; 30% of air is returned through the heat exchanger (it is dehumidified and warmed); 40% of air is returned directly. The Program is used during the day, when the humidity level is low, at the swimming pool premises, when people are at the swimming pool. A portion of the extracted air is dehumidified in the heat exchanger and is mixed with the fresh air, then this air is additionally heated in heat exchanger and mixed with a portion of warm and humid air extracted from the swimming pool and, if necessary, additionally heated with the heater. This Program ensures the required amount of fresh air, helps maintaining the required level of air humidity at the swimming pool premises and saves a lot of energy.

PROGRAMS FOR AN AIR HANDLING UNIT WITH A HEAT PUMP Program P1.1 Flow all air is taken only from the inside, only one (supply) fan works, 30% of its capacity. The Program is used at night time, when no people are at the swimming pool. There is no need for supplying the air from the outside, when there are no people at the swimming pool, i.e. no energy is wasted on heating. The air is extracted from the swimming pool, if necessary, it is pre-heated and returned to the swimming pool. Operation of this Program requires minimum energy consumption in order to make sure that air would not set in at the swimming pool premises and a constant temperature would be maintained. The heat pump is not operated in this Program. Program P2.1 Flow from 30% to 100% of air from the outside. The Program is used during the day, when the humidity level is high, at the swimming pool premises, when people are at the swimming pool. Up to 100% of air may be supplied from the outside based on the required level of dehumidification (the air becomes drier, if more air is supplied from the outside. This applies when the temperature is under +25 C). The air from the outside mixes with a portion of the air indoors cooled down with the, it is pre-heated and dehumidified in the heat exchanger, pre-heated with the, and, if necessary, additionally heated in the heater. This Program ensures the required amount of fresh air, helps maintaining the required level of air humidity at the swimming pool premises, and reduces energy consumption because of high efficiency of the. Program P3.1 Flow - 30% of air from the outside. The Program is used during the day, when people are at the swimming pool. This is the main mode which ensures a good level of dehumidification, sufficient amount of fresh air (based on the standards of hygiene) and a part of energy is saved. The air from the outside mixes with the air indoors cooled down with the, it is pre-heated and dehumidified in the heat exchanger, heated with the, and, if necessary, additionally heated in the heater. This Program ensures the required amount of fresh air, helps maintaining the required level of air humidity at the swimming pool premises, and reduces energy consumption because of high efficiency of the. Program P4.1 Flow - 100% of air from the outside, through the by-pass. The Program is used in summer, during the day, when people are at the swimming pool. No heat exchange takes place because of the small temperature difference outdoors and indoors, thus the entire flow goes through the by-pass. The works, only if it is necessary to pre-heat the supplied air. Program P5.1 Flow cyclically: 30% of air from the outside; 30% of air is returned through the heat exchanger and (it is dehumidified and warmed); 40% of air is returned directly. The Program is used during the day, when the humidity level is low, at the swimming pool premises, when people are at the swimming pool. A portion of the extracted air is dehumidified in the heat exchanger and with the heat pump and mixed with the fresh air, then this air is additionally heated in heat exchanger and with the heat pump and mixed with a portion of warm and humid air extracted from the swimming pool and, if necessary, additionally heated with the heater. This Program ensures the required amount of fresh air, helps maintaining the required level of air humidity at the swimming pool premises and saves a lot of energy. During the cycle, the works when air is being supplied from the outside. The does not function when no air is being supplied from the outside. Program P6.1 Flow - 100% of air from the inside. The heat pump works and dehumidifies the air. The Program is used at night time, when the humidity level is high, at the swimming pool premises. Warm and humid air from the swimming pool passes through the heat exchanger, then it is cooled down with the, pre-heated and dehumidified in the heat exchanger, pre-heated with the, and, if necessary, it may be additionally heated with the heater.

SMART SELECTION PROGRAM VentMaster v5 DESIGNED FOR MODULAR AIR HANDLING UNITS Using Ventmaster makes selection of AmberAir Pool quick and user-friendly: simulation in a 3D environment; price calculation and placing of orders directly (for registered users only); exporting a drawing to a.dxf format; exporting a drawing and technical data to Autodesk Revit; LCC calculations. Choose an optimal option by using the LCC (operating costs) calculation program, which calculates costs to be incurred within the course of operation of the air handling unit by evaluating the initial investment; fan power consumption; heating equipment power consumption, fuel or hot water consumption. VentMaster 2-YEAR WARRANTY Using only reliable components and modern equipment for assembling the products enables us to guarantee an exceptional operation period thereof. All SALDA air handling units are provided with a 2-year warranty. Tested by an independent laboratory SIVENTA. Tests performed: Aerodynamic; Thermal; Acoustic; Electric operation; Sound power level; Sound power level setting. Distributor SALDA UAB Ragainės g. 100 LT-78109 Šiauliai, Lithuania +370 41 54 04 15 +370 41 54 04 17 office@salda.lt www.salda.lt