Daikin Air Conditioning. Daikin air conditioners for shops, restaurants and offices. CEILING SUSPENDED UNIT. UK Price List Attached

Similar documents
Daikin air conditioners for small rooms in multi application

Daikin air conditioners for shops, restaurants and offices

Daikin air conditioners for small rooms in multi application

Daikin air conditioners for shops, restaurants and offices

Daikin air conditioners for shops, restaurants and offices

PRELIMINARY. w w w. d a i k i n e u r o p e. c o m FDQ-B

Daikin air conditioners for shops, restaurants and offices

4-WAY BLOW CEILING MOUNTED CASSETTE Daikin air conditioners for shops, restaurants and offices

TODAY, AIR CONDITIONING UNMISTAKABLY FORMS PART OF THE HOSPITALITY PACKAGE THAT YOU WANT TO OFFER YOUR

Daikin air conditioners for your home, shops, restaurants and offices

Daikin air conditioners for your home

w w w. d a i k i n. e u ATXS-E

Air conditioners, heating & cooling. for large spaces. air to air heat pumps. FDQ-B

Daikin air conditioners for shops, restaurant and offices

Daikin air conditioners for your home

Air conditioners, heating & cooling for shops,restaurants and offices

Daikin air conditioners for your home

for small rooms in multi application

Air conditioners, heating & cooling for the retailmarket and offices

AIR CONDITIONERS, HEATING & COOLING for your home

Ceiling Suspended Unit

for your home FLXS-B Flexi type unit air to air heat pumps

for the retail market, hotels, restaurants and offices

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

AIR COOLED PACKAGED AIR CONDITIONERS

for your home FTYN-GX FT(Y)N-F

Warning. Specifications, designs and other content appearing in this brochure are current as of May 2013 but subject to change without notice.

Air Conditioners Heating & Cooling

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

BENEFIT FROM LOWER FUEL COSTS.

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Full range. A class energy label. for your home WALL MOUNTED UNIT. air to air heat pumps. FTXS-G

air conditioners for your home, shops, restaurants, offices, small hotels MULTI MODEL APPLICATIONS

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

Air Conditioners Heating & Cooling

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

for your home FTXS-G WALL MOUNTED UNIT

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Air Conditioners Heating & Cooling

FTXS20G FTXS25G FTXS35G FTXS42G FTXS50G FTXS60G FTXS71G

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

SERVICE MANUAL. Commercial Air Conditioning. MULTI upgrade series

SPLIT-TYPE AIR CONDITIONERS R410A. New PUMY. S series. up to 8* indoor units. ?P100: up to 6 indoor units PUMY-P100YHM PUMY-P125YHM PUMY-P140YHM

Air Conditioners Heating & Cooling

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

SHOPS, RESTA URA NTS, OFFICES, HOTELS,

. Creating Maximum Comfort

PCSAU1439A. Inverter series

DAIKIN EMURA. FORM. FUNCTION. REDEFINED. THE NEW INDOOR AIR CONDITIONING UNIT FROM DAIKIN.

THE INTELLIGENT CHOICE IN COMFORT SINGLE & MULTI TYPE AIR CONDITIONERS

air conditioners for your home, apartments, shops, restaurants, offices, hotels, w w w. d a i k i n. e u S U P E R M U L T I P L U S

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioners. Technical Data RZQG-L

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

Air Conditioners Heating & Cooling

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Dealer. All rights reserved Printed in Vietnam 03/13/001 VK

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Air Conditioners Heating & Cooling

WCA3**4. Product Specifications

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

RESIDENTIAL & COMMERCIAL CATALOGUE 2008

PLA-ZRP35/50/60/71/100/125/140BA PLA-RP35/50/60/71/100/125/140BA

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Do you want a versatile solution to make significant savings? AIR-TO-WATER HEAT PUMP

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

Air Conditioners Heating & Cooling

technical data air conditioning systems Indoor Units FBQ-C7VEB

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

PCSHK1549. Cooling only -50Hz- Heat pump -50Hz-

Air Conditioners Heating & Cooling

Atlas and Helios Unit Heaters Janus 05 Air Conditioners AIX Stainless Steel Unit Heaters Atlas STP Door Curtains Jetstream Induction Flow Optimizers

Air Conditioners Technical Data

EPLE Water-cooled chillers Remote condenser chillers. EUW40-200MAXY EUWL40-200MXY Applied systems

Air Conditioners. Technical Data FBQ-C

Water-cooled chillers Remote condenser chillers NEW

Air Conditioning. Technical Data EEDEN AZQS-BV1

digital remote control WARRANTY 10 years for excanger

Air Conditioners Heating & Cooling

Precision Air Conditioners

Pure comfort & design

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

Samsung Air Conditioners

Product overview 2-3. Technology of Inverter 4-5. Inverter Wall Mounted 6-7. Inverter Ceiling Cassette E Series 8-9

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Sky Air SUPER INVERTER

HP 5,65 0,9 6, ,47 B - 8,15 1,9 9, ,5 B - 8,4 1,9 9, ,5 B - 8,5 2,1 9, ,7 A - 8,6 2,1 10, ,71 A -

Air Conditioning Systems RESIDENTIAL & COMMERCIAL CATALOGUE

360 airflow!! PCSSG0814. AIR CONDITIONING SYSTEM [50Hz]

Pure comfort & design

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

Air Conditioners Heating & Cooling

Concealed ceiling units

EWWD MBYN EWLD MBYN Applied systems

heating, air conditioning, applied systems, refrigeration GENERAL CATALOGUE 2008

technical data air conditioning systems RZQ B8W1B Split Sky Air

Transcription:

Daikin Air Conditioning Daikin air conditioners for shops, restaurants and offices. CEILING SUSPENDED UNIT UK Price List Attached Correct as of 15/04/08 Please check http://global-cooling.co.uk For the latest inforation For ore inforation about this range of air conditioning systes http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/ceiling-suspended-daikin/ If you need any help please call us on 01200 428888 UK Price List Attached Global Cooling Air Conditioning UK www.global-cooling.co.uk Upbrooks Industrial Estate Clitheroe, Lancashire BB7 1PL, UK UK Air Conditioning Online Shop - http://global-cooling.co/ Air Conditioning Foru - http://air-conditioning-foru.global-cooling.co.uk/

Daikin air conditioners for shops, restaurants and offices CEILING SUSPE NDED UN IT www.daikineurope.co FHQ-BU

Ceiling suspended units are the ideal solution for roos, shops or offices without false ceilings. Since they are installed directly against the ceiling they do not take up any floor or wall space. These indoor units are ideal for unifor air distribution in large spaces because of their long air throw. COMFORT Air flow distribution for ceiling heights up to 3.8 without loss of capacity. The ceiling suspended unit ensures you a cofortable air flow in all directions thanks to an air flow pattern of 100. Cofortable air flow 100 Ceiling suspended unit You have the choice of 2 fan speeds to select: high or low. A high fan speed provides axiu reach while a low fan speed iniizes drafts. Daikin s special dry prograe reduces huidity in the roo without variations in roo teperature. The indoor unit contains an air filter which reoves icroscopic particles and dust.

FLEXIBLE INSTALLATION AND EASY TO USE The reduced lateral servicing space enables the unit to be easily installed in corners and narrow spaces on walls and ceilings. The outdoor unit can be installed on a roof or terrace or placed against an outside wall. Special anti-corrosion treatent of the outdoor unit s heat exchanger fin, gives greater resistance against acid rain and salt corrosion. Additional resistance is provided by a rust proof steel sheet on the underside of the unit. An anti-corrosion heat exchanger cutaway view Heat exchanger Hydrophilic fil Aluiniu Corrosion-resistant Acrylic resin Daikin reote controls give you easy control at your fingertips. The wired reote control provides you with a schedule tier, enabling to progra the air conditioning daily or weekly. The optional reote ON/OFF enables you to start/stop the air conditioning fro a obile phone via a telephone reote control (field supply). The optional forced OFF enables you to switch off the unit autoatically. E.g. when a window is opened, the unit switches off Infrared reote control (Optional) Wired reote control (Optional)

ENERGY EFFICIENT Energy label: up to class B Inverter technology Iproved energy efficiency: The use of integrated inverter control ensures axiu energy efficiency by supplying only the required heating or cooling load where a standard non inverter unit would supply axiu load in an on/off regie. Keeps teperature stable Slow start-up Saller teperature difference Large teperature difference Set point Non inverter air conditioning Startup tie reduced by about 1/3 Repeats hot and cold cycles Inverter air conditioning Iproved cofort: The rapid start up tie provided by the inverter increases cofort by reducing the lead tie in obtaining the required indoor teperature. As soon as the required teperature is reached, the inverter unit continuously scans the roo for sall changes and adjusts the roo teperature in seconds, thereby increasing cofort once again. The hoe leave operation button prevents large teperature differences by continuously operating at a iniu (heating ode) or axiu (cooling ode) preset level while you re out or sleeping. It also allows the indoor teperature to return quickly to your favourite cofort level. ONE PUSH While out of the hoe PUSH AGAIN When you go out push the Hoe leave operation button, and the air conditioner will adjust capacity to reach the preset teperature for Hoe leave operation. When you return, you will be welcoed by a cofortable air-conditioned roo. Push the Hoe leave operation button again, and the air conditioner will adjust capacity to the set teperature for noral operation. APPLICATION OPTIONS This odel can be used both in cooling only or heating. It is possible to use the indoor unit in pair (connecting one indoor to one outdoor), twin, triple, double twin (connecting up to 4 indoors in the sae roo to a single outdoor) and ulti applications (connecting up to 9 units in several roos to 1 outdoor unit).

Capacity and power input COOLING ONLY - INVERTER CONTROLLED (air cooled) Cooling capacity in~no~ax kw Noinal input in~no~ax kw EER Energy label Annual energy consuption cooling kwh COOLING ONLY - NON INVERTER (air cooled) Cooling capacity noinal kw Noinal input noinal kw EER Energy label Annual energy consuption cooling kwh HEAT PUMP - INVERTER CONTROLLED (air cooled) Cooling capacity in~no~ax kw Heating capacity in~no~ax kw Noinal input cooling in~no~ax kw heating in~no~ax kw EER COP Energy label cooling heating Annual energy consuption cooling kwh HEAT PUMP - NON INVERTER (air cooled) Cooling capacity noinal kw Heating capacity noinal kw Noinal input cooling noinal kw heating noinal kw EER COP Energy label cooling heating Annual energy consuption cooling kwh FHQ35BUV1B FHQ50BUV1B FHQ60BUV1B RKS35DVMB RKS50BVMB9 RKS60BVMB9 1.4~3.4~3.7 0.90~5.00~5.60 0.90~5.70~6.00 0.30~1.21~1.50 0.45~1.83~2.02 0.44~2.15~2.23 2.81 2.73 2.65 C D D 605 915 1,075 FHQ50BUV1B FHQ60BUV1B FHQ71BUV1B FHQ100BUV1B FHQ125BUV1B RS50BVMB RS60BVMB RR71B7V3B/W1B RR100B7V3B/W1B RR125B7W1B 5.00 5.70 7.10 9.80 12.20 1.83 2.15 2.70/2.65 3.75/3.68 4.50 2.73 2.65 2.63/2.68 2.61/2.66 2.71 D D D/D D/D D 915 1,075 1,350/1,325 1,875/1,840 2,250 FHQ35BUV1B FHQ50BUV1B FHQ60BUV1B FHQ71BUV1B FHQ100BUV1B FHQ125BUV1B RXS35DVMB RXS50BVMB RXS60BVMB RZQ71B8V3B RZQ100B8V3B/B7W1B RZQ125B8V3B/B7W1B 1.4~3.4~3.7 0.90~5.00~5.60 0.90~5.70~6.00 7.10 (no) 10.00 (no) 12.50 (no) 1.4~4.1~5.0 0.90~6.00~7.00 0.90~7.20~8.00 8.00 (no) 11.20 (no) 14.00 (no) 0.30~1.21~1.50 0.45~1.83~2.02 0.44~2.15~2.23 2.46 (no) 3.15 (no) 4.45 (no.) 0.29~1.18~1.62 0.36~2.05~2.45 0.40~2.49~2.75 2.67 (no) 3.60 (no.) 4.50 (no.) 2.81 2.73 2.65 2.89 3.17 2.81 3.47 2.93 2.89 3.00 3.11 3.11 C D D C B C B D D D D D 605 915 1,075 1,230 1,575 2,225 FHQ71BUV1B FHQ100BUV1B FHQ125BUV1B RQ71B7V3B/W1B RQ100B7V3B/W1B RQ125B7W1B 7.10 9.80 12.20 8.00 11.20 14.50 2.70/2.65 3.75/3.68 4.50 2.85/2.80 4.13/4.01 5.16 2.63/2.68 2.61/2.66 2.71 2.81/2.86 2.71/2.79 2.81 D/D D/D D D/D E/E D 1,350/1,325 1,875/1,840 2,250 Notes: 1) Energy label: scale fro A (ost efficient) to G (less efficient). 2) Annual energy consuption: based on average use of 500 running hours per year full load ( = noinal capacity). MULTI - COOLING ONLY 4MKS58D 4MKS75D 4MKS90D MULTI - HEAT PUMP 2MXS52D* 3MXS52D* 4MXS68D* 4MXS80D* SUPER MULTI PLUS - HEAT PUMP RMXS112D* RMXS140D* RMXS160D* Max. n Max. cooling Max. PI cooling of indoor units capacities (kw) (kw) 4 6.60 2.47 4 9.27 3.71 4 9.86 3.52 Max. n Max. cooling Max. PI cooling Max. heating Max. PI heating of indoor units capacities (kw) (kw) capacities (kw) (kw) 2 6.50 2.69 7.34 2.42 3 6.50 2.69 7.34 2.42 4 8.68 3.69 10.64 3.41 4 9.49 3.34 11.00 3.52 Max. n Max. cooling Max. PI cooling Max. heating Max. PI heating of indoor units capacities (kw) (kw) capacities (kw) (kw) 7 11.20 3.57 12.50 4.01 8 14.00 5.23 16.00 5.31 9 15.50 5.55 17.50 5.56 Notes: - For ore detailed inforation about specifications, capacities, power input, energy labelling and annual energy consuption, please refer to our Multi Model catalogue or check with your local dealer. * At least 2 indoor units should be connected to a Multi outdoor unit.

TWIN/TRIPLE/DOUBLE TWIN APPLICATION RR/RQ71 RR/RQ100 RR/RQ125 RZQ71 RZQ100 RZQ125 RZQ140 RZQ200 RZQ250 FHQ35BUV1B FHQ50BUV1B FHQ60BUV1B FHQ71BUV1B FHQ100BUV1B FHQ125BUV1B 2 3 2 3 2 2 3 2 4 3 2 4 3 2 4 3 3 2 4 2 Specifications indoor units COOLING ONLY/HEAT PUMP Diensions HxWxD Weight Casing colour Air flow rate cooling H/L 3 /in heating H/L 3 /in Fan speed Sound pressure level cooling H/L db(a) heating H/L db(a) Sound power level cooling H/L db(a) heating H/L db(a) Piping connections liquid gas drain (VP20) ID OD Heat insulation FHQ35BUV1 FHQ50BUV1 FHQ60BUV1 FHQ71BUV1B FHQ100BUV1B FHQ125BUV1B 195x960x680 195x1,160x680 195x1,400x680 195x1,590x680 24 25 27 32 35 White 13/10 13/10 17/13 17/14 24/20 30/25 13/10 13/10 16/13 17/14 24/20 30/25 2 steps 37/32 38/33 39/33 39/35 42/37 44/39 37/32 38/33 39/33 39/35 42/37 44/39 53/48 54/49 55/49 55/51 58/53 60/55 53/48 54/49 55/49 55/51 58/53 60/55 ø6.4 ø9.5 ø9.5 ø12.7 ø15.9 ø20 ø26 Both liquid and gas pipes Indoor units: FHQ-BU FHQ35,50BUV1 FHQ60,71BUV1

Specifications outdoor units COOLING ONLY - INVERTER CONTROLLED Diensions HxWxD Weight Casing colour Sound pressure level H/L db(a) Sound power level H db(a) Copressor Refrigerant type Refrigerant charge / Maxiu piping length Maxiu level difference Operation range fro ~ to CDB COOLING ONLY - NON INVERTER Diensions HxWxD Weight Casing colour Sound pressure level H db(a) Sound power level H db(a) Copressor Refrigerant type Refrigerant charge / Maxiu piping length Maxiu level difference Operation range fro ~ to CDB HEAT PUMP - INVERTER CONTROLLED Diensions HxWxD Weight Casing colour Sound pressure level cooling H/L db(a) (night quiet ode) heating H/L db(a) Sound power level cooling H db(a) heating H db(a) Copressor Refrigerant type Refrigerant charge / Maxiu piping length Maxiu level difference Operation range cooling fro ~ to CDB heating fro ~ to CWB HEAT PUMP - NON INVERTER Diensions HxWxD Weight Casing colour Sound pressure level cooling H db(a) Sound power level cooling H db(a) Copressor Refrigerant type Refrigerant charge / Maxiu piping length Maxiu level difference Operation range cooling fro ~ to CDB heating fro ~ to CWB RKS35DVMB RKS50BVMB9 RKS60BVMB9 550x765x285 735x825x300 32 49 53 47/44 47/- 49/- 62 63 64 heretically sealed swing type 0.02 (for piping length > 10) 20 30 15 20-10~46-10(-15*)~46 RS50BVMB RS60BVMB RR71B7V3B/W1B RR100B7V3B/W1B RR125B7W1B 735x825x300 770x900x320 1,170x900x320 49 53 83/81 102/99 106 47 49 50 53 53 63 64 63 66 67 Swing copressor heretically sealed scroll type 0.02 (piping length>10) 2.70 3.70 3.70 30 70(equivalent length 90) 20 30 +10~46-15~46 RXS35DVMB RXS50BVMB RXS60BVMB RZQ71B8V3B RZQ100B8V3B/B7W1B RZQ125B8V3B/B7W1B 550x765x285 735x825x300 770x900x320 1,345x900x320 32 49 53 68 106 47/44 47/- 49/- 47(43) 49(45) 50(45) 48/45 48/- 49/- 49/- 51/- 52/- 62 63 64 63 65 66 63 64 64 - - - Heretically sealed swing Her. sealed swing heretically sealed scroll type 0.02 (for piping length > 10) 2.8 (for 30) 4.3 (for 30) 20 30 50 (equiv. length 70) 75 (equivalent length 95) 15 20 5-10~46-15~50-15~20-20~15.5 RQ71B7V3B/W1B RQ100B7V3B/W1B RQ125B7W1B 770x900x320 1,170x900x320 84/83 103/101 108 50 53 53 63 66 67 heretically sealed scroll type 2.70 3.70 3.70 70 (equivalent length 90) 30-5~46-10~15 * Possibility to extend the operation range down to -15 C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20 C or lower and will recover when teperature rises again. - Inforation is not available.

Accessories: control systes INDOOR UNITS FHQ35BU FHQ50BU FHQ60BU FHQ71BU FHQ100BU FHQ125BU Wired reote control BRC1D527 Infrared reote control cooling only BRC7E66 heat pup BRC7E63W Centralised reote control DCS302C51 Unified ON/OFF control DCS301B51 Schedule tier DST301B51 Adapter for wiring KRP1B54 Adapter for external ON/OFF and onitoring (1) KRP4A52 Adapter for wiring (hour eter) (2) EKRP1B2 - Interface adapter for Sky Air DTA112B51 Installation box for adapter PCB KRP1C93 Reote ON/OFF, forced OFF EKRORO (1) Installation box for adapter PCB (KRP1C93) is necesarry (2) Possibility to connect an hour eter (field supply). This part should not be installed inside the equipent Accessories INDOOR UNITS FHQ35BU FHQ50BU FHQ60BU FHQ71BU FHQ100BU FHQ125BU Replaceent long-life filter KAFJ501D56 KAFJ501D80 KAFJ501D112 KAFJ501D160 Drain-up kit KDU50M60VE KDU50M125VE L-type piping kit (upward direction) KHFP5M35 KHFP5M63 KHFP5M160 Accessories OUTDOOR UNITS Air direction adjustent grille Central drain plug OUTDOOR UNITS RKS/RXS35D RS/RKS/RXS50B RS/RKS/RXS60B KRW937A4 KPW945A4 KKP937A4 - - RR/RQ71B7 RR/RQ100B7 RR/RQ125B7 RZQ71B RZQ100B RZQ125B Central drain plug Refrigerant branch piping Deand adapter kit for twin for triple for double twin reote control of sound reduction and power input KKPJ5F180 KKPJ5F180 KHRQ22M20TA7 KHRQ22M20TA7 - KHRQ127H7 - KHRQ127H7 - - KHRQ22M20TA7 (x3) - - - KRP58M51 Notes: 1) V1 = 1~, 230V, 50Hz; VM = 1~, 220-240V/220-230V, 50Hz/60Hz, V3 = 1~, 230V, 50Hz 2) Noinal cooling capacities are based on: indoor teperature 27 CDB/19 CWB * outdoor teperature 35 CDB * refrigerant piping length 7.5 * level difference 0. 3) Noinal heating capacities are based on: indoor teperature 20 CDB * outdoor teperature 7 CDB/6 CWB * refrigerant piping length 7.5 * level difference 0. 4) Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan otor heat. 5) Units should be selected on noinal capacity. Max. capacity is liited to peak periods. 6) The sound pressure level is easured via a icrophone at a certain distance fro the unit (for easuring conditions: please refer to the technical data books). 7) The sound power level is an absolute value indicating the "power" which a sound source generated. Daikin s unique position as a anufacturer of air conditioning equipent, copressors and refrigerants has led to its close involveent in environental issues. For several years Daikin has had the intention to becoe a leader in the provision of environental friendly products. This challenge deands the eco design and developent of a wide range of products and an energy anageent syste; which involves energy conservation and reduction of waste. Daikin Europe N.V. is approved by LRQA for its Quality Manageent Syste in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, developent, anufacturing as well as to services related to the product. ISO14001 assures an effective environental anageent syste in order to help protect huan health and the environent fro the potential ipact of our activities, products and services and to assist in aintaining and iproving the quality of the environent. Daikin units coply with the European regulations that guarantee the safety of the product. Daikin Europe N.V. is participating in the EUROVENT Certification Prograe. Products are as listed in the EUROVENT Directory of Certified Products. Multi units are Eurovent certified for cobinations up to 2 indoor units. Specifications are subject to change without prior notice. Daikin products are distributed by: Zandvoordestraat 300 B-8400 Oostende, Belgiu www.daikineurope.co EPLE05-23 / 300 / 03/05 / La Movida Printed on non-chlorinated paper / Printed in Belgiu

Global Cooling Air Conditioning UK Prices* Daikin FHQ Ceiling Suspended Type Air Conditioning COOLING ONLY TYPES Features No cooling No heating Daikin Inverter Models Cooling Only types below Min~nor~ax Min~nor~ax Uk cool T/C UK Cool S/C Uk heat - - Inter wires - - Max pipe - - - - Price Run aps Fuse connecting Liquid Suction separation Max level in ab in out Exc Vat FHQ35B+RKS35F Buy it 1.4~3.4~3.7 n/a 3.4 2.6 n/a 5.5 15 3+e 1/4" 3/8" 25 15-10 18 37 1133.49 FHQ50B+RKS50G Buy it 1.7~5.0~5.6 n/a 5.0 3.5 n/a 7.3 20 3+e 1/4" 1/2" 30 20-10 18 49 1299.48 FHQ60B+RKS60F Buy it 1.7~5.7~6.0 n/a 5.7 4.1 n/a 9.3 20 3+e 1/4" 1/2" 30 20-10 18 53 1425.06 *Please check the following page for latest specifications. http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/ceiling-suspended-daikin/ Please see the next page for heat pup type prices.

Global Cooling Air Conditioning UK Prices* Daikin FHQ Ceiling Suspended Type Air Conditioning HEAT PUMP TYPES Features No cooling No heating Daikin Inverter Models Heat Pup types below FHQ35B+RXS35F FHQ50B+RXS50G FHQ60B+RXS60F Buy it Buy it Buy it Min~nor~ax Min~nor~ax Uk cool T/C UK Cool S/C Uk heat - - Inter wires - - Max pipe - - - - Price Run aps Fuse connecting Liquid Suction separation Max level in ab in out Exc Vat 1.4~3.4~3.7 1.2~4.0~5.0 3.4 2.6 3.0 5.5 15 3+e 1/4" 3/8" 25 15-10 18 37 1199.01 1.7~5.0~5.6 1.7~6.0~7.0 5.0 3.5 4.3 7.3 20 3+e 1/4" 1/2" 30 20-10 18 49 1394.48 1.7~5.7~6.0 1.7~7.2~8.0 5.7 4.1 5.2 9.3 20 3+e 1/4" 1/2" 30 20-10 18 53 1520.06 *Please check the following page for latest specifications. http://global-cooling.co.uk/airconditioning/air-conditioning-brands/daikin-air-conditioning/ceiling-suspended-daikin/ If you need any help please call us on 01200 428888