FIRE APPARATUS ACCESS

Similar documents
FIRE APPARATUS ACCESS AND WATER SUPPLY GUIDELINE

FIRE SERVICE FEATURES

Fire & Life Safety Requirements For Fire Department Access and Water Supplies

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

Site Plans. Fire Code Requirements

EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

ORDINANCE NO

FIRE CODE APPLICATION GUIDE FOR DEVELOPMENT IN UNINCORPORATED MULTNOMAH COUNTY

4/13/2015. Everything a firefighter wants to tell a design professional or building code official, in one hour.

EXHIBIT A STEAMBOAT SPRINGS FIRE PREVENTION SERVICES ADMINISTRATIVE POLICY & PROCEDURE MANUAL

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

Fire Prevention Bureau INFORMATION PACKAGE

TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions

RED BOOK CONTRACTOR S. Fire Department Access and Design Engineering Information

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES

TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)

C I T Y O F B A N N I N G BANNING FIRE SERVICES 3900 W. WILSON STREET (951) PHONE (951) FAX

FIRE PREVENTION CODE

ICC CODE CORNER 2015 International Fire Code

Construction and Development Guide

Richardson Fire Department 136 N. Greenville Avenue, Richardson, TX Telephone: Fax:

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Drexel Heights Fire District 2012 International Fire Code Amendments

FIRE PREVENTION CODE. conditions hazardous to life and property from fire, hazardous materials, or explosion.

Fire Department Access and Water Supply

ORDINANCE NO WHEREAS, the WSBCC has recently adopted new editions of several of such International codes; and

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

1301: Fire service features.

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

Louisville Metro Ordinance (Chapter 94: Fire Prevention) FIRE HYDRANTS, WATER MAINS AND WATER SUPPLY.

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Mobile Fire Rescue Department Bureau of Fire Prevention

VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)

Construction & Development Procedures Guide

Mt. Crested Butte Code

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

FIRE SERVICE FEATURES

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up)

Large Family Daycare Guideline

Elk Creek Fire Protection District

VIOLET TOWNSHIP ZONING & BUILDING DEPARTMENT Rustic Drive Pickerington, Ohio (614) Fax (614)

Business Fire Inspection. City of Guadalupe

FIRE PREVENTION STANDARDS

Chapter 2: Identification, water and access

ICC CODE CORNER 2015 International Fire Code

CAMP VERDE FIRE DISTRICT

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

We have reviewed the proposed concept plans for Beehive Homes and have the following comments:

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Chapter Nursing Homes


CITY OF CHESAPEAKE PUBLIC FACILITIES MANUAL CHAPTER XIII FIRE PROTECTION

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

CITY OF PALM BEACH GARDENS ORDINANCE NO. 12, 2002

SOMERSWORTH CODE FIRE PREVENTION AND LIFE SAFETY CHAPTER 21

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

FIRE PLAN CHECK FORM/CORRECTION List for Single Family Residences, Duplexes, and Garages

ORDINANCE NO , Series of , AND OF THE PARKER MUNICIPAL CODE CONCERNING THE PARKER FIRE PROTECTION CODE

ORDINANCE NO, 5907 AN ORDINANCE AMENDING ALBANY MUNICIPAL CODE CHAPTER , UNIFORM FIRE CODE

ORDINANCE NUMBER

Mobile Food Units. A definition of mobile food unit added in OFC Rule 2 is as follows:

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

ORDINANCE NO WHEREAS, the WSBCC has recently adopted new editions of several of such International codes; and

Life Safety - Means of Egress/Exits NFPA 101

CHAPTER 92: FIRE PREVENTION; FIREWORKS

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC

Level I Chapter 1 Worksheet

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

HAWAII ADMINISTRATIVE RULES TITLE 12 DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS SUBTITLE 7 BOARDS CHAPTER 45.1 STATE FIRE COUNCIL STATE FIRE CODE

Fire Suppression Introduction Contact Information

Residential Based Care Facility Guidelines

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector Permit

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Residential-based Care Facility R-4 Guideline

Plan Review Check List Fire Alarm System

(d) (e) Section Dry cleaning. Section Exhibits and trade shows

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

A Comprehensive Community Risk Reduction Initiative A COMPREHENSIVE COMMUNITY RISK REDUCTION INITIATIVE

CHAPTER 6 FIRE SAFETY STANDARDS. Adopted: September 22, Revised: August 7, April 1, May 15, June 1, 2003

Outdoor Festival and Special Event Guidelines

FIRE PREVENTION GUIDELINE

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

BYLAW 5542 *******************************************************************************

For additional information please contact the Chesapeake Fire Prevention Office at or at

SUBTITLE X Chapter BUILDING CODE

Retain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)

S 2758 S T A T E O F R H O D E I S L A N D

Transcription:

FIRE PROTECTION REQUIREMENTS FIRE APPARATUS ACCESS INCLUDING FIRE LANES, GATES, AND ACCESS ROADS Bureau of Fire Prevention 111 Basin ST / P.O. Box 884 Hebron, Ohio 43025 Telephone: 740-928-4721 Fax: 740-928-2726 fireprevention@hebronfd.org http://www.hebronfd.org ** PERMIT REQUIRED ** This publication outlines the fire protection requirements for the design and installation of any required fire lanes within the Village of Hebron and Union Township. As a reminder, unless otherwise specified, anything that requires you to obtain a permit from the fire department may also require you to obtain a permit issued by the Licking County Building Code Department (LCBC), Union Township's Zoning Administrator (UTZ), and/or the Village of Hebron's Planning and Zoning Department (HPZ). Their offices are located at: - LCBC: 675 Price Road, Newark, OH 43055 / (740) 349-6671 - UTZ: 1380 Beaver Run SE, Hebron, OH 43025 / (740) 928-7655 - HPZ: 934 W. Main Street, Hebron, OH 43025 / (740) 928-0076 *** PLEASE REVIEW THIS ENTIRE PUBLICATION BEFORE TAKING ACTION *** Questions regarding the content of this publication should be directed to the Bureau of Fire Prevention at (740) 928-4721 ext. 111 during regular office hours, Monday thru Friday OVERVIEW. The proper design and installation of a fire lane is an important part of providing efficient and effective fire protection. Therefore, the design and installation of any required fire lane shall be : - Approved by the Bureau of Fire Prevention of the Hebron Fire Department - In accordance with the most current version of the Ohio Fire Code (OFC) as required by Ohio Revised Code (ORC) 3737.82. - In accordance with all code requirements of the respective political jurisdiction. APPROVAL REQUIRED. As outlined in OFC Section 501.3, approved construction and site plans shall be submitted to ensure proper code compliance and that the fire protection needs are met. All construction documents shall be approved prior to the start of construction. 1 of 9

DEFINITIONS. The following words, terms, and acronyms shall, for the purposes of this standard and the permit requirements of the Hebron Fire Department, have the meanings shown herein: Approved Roof Access. A safe, permanently mounted ladder or set of stairs that was designed and installed for the specific purpose of gaining access to the rooftop. The access must be a minimum 3 foot x 3 foot opening. EMS. Emergency Medical Services Fire Apparatus Access Road. A road or other passageway developed to allow the passage of fire apparatus. Fire Lane. The designated portion of an access road that must be kept clear to allow the ingress and egress of fire and ems vehicles. Fire Protection Equipment. Any object or system designed to help protect a building, it's contents, and it's occupants from the threat of fire. (Ex. fire hydrants, sprinkler system components, etc.) HVAC. Heating, ventilation, and Air Conditioning Occupancy Groups F. Factory/Industrial (Manufacturing, processing, etc.) H. High Hazard (Explosion hazards, high quantity of flammable liquids, etc.) I. Institutional (Hospitals, jails, nursing homes, etc.) R-3. Permanent residential units (Single family dwellings, etc.) S. Storage (Warehouses,etc.) U. Miscellaneous (Barns, tanks, towers, silos, etc.) OFC. Ohio Fire Code, current edition ORC. Ohio Revised Code 2 of 9

GENERAL REQUIREMENTS. The Fire Marshal and/or the Fire Chief shall determine which access roads and fire lanes shall comply with this standard. The determination shall also be made as to the extent of the fire lane designation. In the event that a requirement set forth in this document, which is contradictory to that of any order issued by another applicable authority, code, or law, the most stringent order shall be enforced. FIRE APPARATUS ACCESS ROADS. Approved fire apparatus access roads shall be provided for every facility, building, or portion of a building hereafter constructed or moved into or within the jurisdiction which are not readily accessible from a public and/or private street. APPLICATION. Fire apparatus access roads shall extend to within 150 feet of all portions of the facility and all portions of the exterior walls of the first story of the building, as measured by an approved route around the exterior of the building or facility. Deviations to this requirement may occur in cases such as when the topography or property does not allow for this to occur or when there are no more than two structures meeting the occupancy classification of a Group R-3 or U. SPECIFICATIONS. All fire apparatus access roads, parking areas within 150 feet of a structure, or any other location that the Fire Marshal and/or Fire Chief deem necessary for access by fire apparatus shall provide the following: WIDTH. A minimum unobstructed width of 20 feet shall be provided, excluding the shoulder, parking areas, or any other locations that may obstruct the access or travel of fire apparatus. This width shall be increased to 25 feet when any of the following conditions apply: - The occupancy use has been identified as a Group F, H, I, or S - The structure has a height greater than 30 feet - The structure has a mechanical device installed on the roof (ex. HVAC) - The structure does not have an approved roof access - Fire hydrants present along the access road CLEARANCE. An unobstructed vertical clearance of not less than 13 feet, 6 inches shall be provided. 3 of 9

SURFACE. The surface of a fire apparatus access road shall be asphalt, concrete, or other approved surface that is capable of supporting a minimum weight of 75,000 pounds. GRADE. The grade of a fire apparatus access road shall not be greater than 10%, unless otherwise approved by the Fire Marshal and/or Fire Chief. DEAD ENDS. Fire apparatus access roads in excess of 150 feet in length shall provide an approved area that will allow fire apparatus to turn around. The design of the turn around shall be consistent with following: LENGTH 151-500 Feet: 120-Foot Hammerhead, 60-Foot "Y", or 96-Foot Diameter Cul-De-Sac with a road width of 20 feet. 501-750 Feet: 120-Foot Hammerhead, 60-Foot "Y", or 96-Foot Diameter Cul-De-Sac with a road width of 25 feet. Over 750 Feet: Permission required by Fire Marshal and/or Fire Chief. 4 of 9

SECURITY GATES. Any gate obstructs the access of fire apparatus shall meet the following requirements: - Have a minimum gate width equivalent to the width required of the fire apparatus access road. - Be capable of being operated by one person. - In the case of non-electric gates, shall have a Knox Box mounted in a location designated by the fire code official. Gates of this type, specifically installed to accommodate fire department access, shall be secured with a Knox Padlock. - In the case of electric gates, shall have a Knox Access Switch installed in a location approved by the fire code official. The switch shall allow for a hold open feature. - Gates that require fire apparatus to turn into them shall be designed to accommodate the turning radius of an aerial apparatus. 5 of 9

FIRE LANES. Fire lanes are designed to provide fire apparatus with unimpeded access to a building, so that firefighters may be able to perform their duties more effectively. Unfortunately, many fire lanes continuously become obstructed, because the identification of the fire lane is not evident enough to attract the attention of the person obstructing it. In an effort to correct this, the following requirements have been established for all designated fire lanes. Note that a fire lane is not the same as a fire apparatus access road, so it is not required to be identified in this manner unless otherwise ordered by the Fire Marshal and/or the Fire Chief. IDENTIFICATION. The length of fire lanes shall be identified with both of the following methods, unless otherwise determined by the Fire Marshal and/or Fire Chief: (1) Signs. See Exhibit A - Shall be placed along the length of the fire lane every 150-175 feet or as required by the Fire Marshal and/or Fire Chief. Each section and/or direction shall have at least one sign with arrows indicating the area of the fire lane. - Signs shall be of standard size, constructed of aluminum, and mounted between 4-5 feet high from the finished grade on a post or building face. - Signs shall contrast with the background and be reflective red-on-white or white-on-red, as determined by the Fire Marshal and/or the Fire Chief. (2) Painted Area. See Exhibit B - All curbing which outlines the fire lanes shall be painted red. White lettering reading NO PARKING FIRE LANE shall be a minimum of 4 inches tall and placed every 30-50 feet or portion thereof. The lettering shall be placed on the face of the curb, or top when faceless curb is present, and at least once on each section and/or direction. See Exhibit C for diagram. - The baseline opposite the curb shall be at least 4 inches wide and outlined with a 1 inch white stripe on the top and bottom. White lettering reading "NO PARKING FIRE LANE" shall be a minimum 3 inches tall and be spaced in the center between each writing block on the curb so that it alternates. - The space between the curb and baseline shall have minimum 4 inch wide red stripes painted at a 30 degree angle spaced every 3 feet. Spaced in the center between the baseline and curb shall have the words "NO PARKING FIRE LANE" painted in white. The height of this lettering shall be equal to 20% of the distance between the curb and baseline. FIRE PROTECTION EQUIPMENT. Equipment shall have a red curbing and/or a minimum of 8 inch wide additional red stripping. White lettering reading NO PARKING FIRE LANE. Dry hydrants may not be required to have a painted area, but all shall have a sign as indicated in Exhibit D. 6 of 9