49 Danfoss Thermostat Kits Ranco Varifix Kits

Dual Pressure Controls

section8 CONTROLS & MEASUREMENT

TEMPERATURE & PRESSURE CONTROLS

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Pressure switch KPU. Data sheet

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

Installation Instructions. Revision Date: 05/16/12

Product catalogue 2012/13. Electromechanical controllers

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Thermostat KPU. Data sheet

Settlement Agreement. Schedule 1: Covered Products

For Technical Service Telephone Facsimile

Commercial Refrigeration Catalog

Europe. Combine Strong Competitiveness and Reliability. Made in. lightcommercialrefrigeration.danfoss.com

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

Kirby Drop-In Packaged Refrigeration Units

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Electromechanical cold controls for refrigerators and freezers MAKING MODERN LIVING POSSIBLE. Type description

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

TC-5231 Series, TC-5232, & TC-5241 Series

ECL Comfort 300 / V a.c. and 24 V a.c.

REMOTE COOLER AIR COOLED & WATER COOLED

Davies Is Your #1 Source For Temperature Controls

For more Parts Information:

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

ECL Comfort V a.c. and 24 V a.c.

Glass Washer. PERLICK Glass Washer NO ONE WORKS HARDER TO KEEP YOU COOKING. WHALEY FOODSERVICE REPAIRS ITEM PART NO. NO.

EVAPORATIVE COOLER PUMPS

VANGUARD 245 POST-MIX DISPENSER

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

LINE COMPONENTS VALVES

Cartridge Heaters. Metric FIREROD Cartridge. Applications and Technical Data

BUSES. SCHOOL, SHUTTLE and TRANSIT. Table of Contents APPLICATIONS - BUSES. BLOWER MOTORS Includes Defroster Fans COMPRESSORS...

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

INSTALLATION INSTRUCTIONS

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

HT V2 HT Split

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Shelleyglas /Shelleysteel

Replacement Parts List For Models COS-20G

General information on refrigerant controllers

CURTIS Gemini 12 Brewer

For more Parts Information:

HWD-2110 Hot Water Dispenser

Electromechanical cold controls for refrigerators and freezers

SpaceKeeper Console (SKC)

VA G 052 S

THERMOSTATS THERMOSTATS HEATING AND COOLING

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Wiring Diagrams Units Produced After April 20, 2009

SMALL PRESSURE CONTROLS (DISC TYPE)

Condensing Units CUS 15-60

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Refrigeration Supplies

Give It Gas - operates solely as an ONLINE BUSINESS Tel: (011) Cell: (082)

Houses, farms, caravans, boats, buses and RV s, campervans, camper trailers, 4WD s and trucks, cabins, cars and tiny houses, hinterland retreats,

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

UNICEF SD Technical basis for UNICEF procurement. Immunization refrigerators industry consultation October, 2016 Copenhagen

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

Process glycol chillers

CR1 Series Triton Corrosion Resistant Washdown Heaters

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

Model HC-2. Crathco Whipped Hot Chocolate Dispenser. Table of Contents. Operation and Instruction Manual. for

CATALOG OF REPLACEMENT PARTS

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

MANITOWOC HOTEL DISPENSER SPA160 + ID0322A MANITOWOC NEW INDIGO 322# AIR COOLED, DICE CUBE ICE MACHINE C/W 22 WIDE 120 LB STORAGE DISPENSER $ 13,960 S

"ER" Series Electric Humidifier

intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

WATER SUPPLY HOOK-UP DISPLAY 0-WSH-1

Reducing Refrigerant Leakage

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

PriceList Category PartNbr Part Description Weight (l MSRP

HWD-2105 Hot Water Dispenser. NOTICE TO INSTALLER: Please leave this book with the machine.

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

Scotsman Technical Training. CU50 Cube Ice Machine

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

MODEL CMA-180UC PARTS MANUAL Rev 1.16

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

TSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton

Refrigerant Recovery Unit, Model RRU134

UNIVERSAL 750 PRE-MIX DISPENSER

ICE/BEVERAGE DISPENSER

Transcription:

FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63

64 Head Office 01543 437 010

Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010 NO-6 Freezer M.O.R. Signal E011 NO-7 Freezer B.O.R. Signal E012 NO-8 Bottle and Liquid Cooler Ranco Varifix Thermostat Kits TYPE TO SUIT E020 VC-1 Refrigerator E021 VA-2 Absorption Refrigerator E022 VF-3 Freezer E023 VP-4 Refrigerator Push/Defrost E024 VS-5 Freezer M.O.R. Signal E025 VR-6 Freezer B.O.R. Signal E026 VB-7 Bottle Cooler E027 VW-8 Window Air Conditioning E028 VT-9 Fridge Freezer/Larder Fridge E029 VX-0 Fridge Freezer/Larder Fridge* E030 VT-93 Fridge Freezer/Larder Fridge** *Similar to VT-9 but operates at a higher temperature **Same as VT-9 but with 3.0 metre capillary 65

Ranco Pressure Switches Ranco 016 models are single pressure switches with changeover contacts. LP Range - bar 0.3 to 7.0 Differential - Auto reset 0.6 to 4.0 Manual 0.6 fixed HP Range bar 7 to 30 Differential - Auto reset 2.5 to 8.0 Manual 3.2 fixed 017 models are dual switches fitted with an extra contact to give an independent high or low-pressure trip signal. MODEL STYLE RESET E060 016-6703 Low Pressure Auto E061 016-6705 Low Pressure Manual E062 016-6750 High Pressure Auto E063 016-6751 High Pressure Manual MODEL STYLE RESET E064 017-4701 Dual LP/HP Auto/Auto E065 017-4703 Dual LP/HP Man/Man E067 017-4705 Dual LP/HP Auto/Man Danfoss Pressure Switches KP-1 models are single low-pressure switches with changeover contacts. Range 0.2 to 7.5 bar. Differential - Auto reset 0.7 to 4.0 Manual 0.7 fixed KP-5 models are single high-pressure switches with changeover contacts. Range 8 to 32 bar. Differential - Auto reset 1.8 to 6.0 Manual 3.0 fixed KP-15 models are dual switches fitted with an extra contact to give an independent low-pressure trip signal MODEL STYLE RANGE (bar) DIFFERENTIAL (bar) RESET DANFOSS NO E800 KP-1 Low Pressure -0.2 to 7.5 0.7 to 4.0 Auto 060-110166 E801 KP-1 Low Pressure -0.9 to 7.0 0.7 Fixed Manual 060-110366 E803 KP-5 High Pressure 8.0 to 32 1.8 to 6.0 Auto 060-117966 E804 KP-5 High Pressure 8.0 to 28 1.8 to 6.0 Auto 060-117166 E805 KP-5 High Pressure 8.0 to 28 3.0 Fixed Manual 060-117366 MODEL STYLE E807 KP-15 Dual LP/HP E809 KP-15 Dual LP/HP E808 KP-15 Dual LP/HP E810 KP-15 Dual LP/HP RANGE (bar) HP 8.0 to 28 LP -0.2 to 7.5 HP 8.0 to 28 LP -0.2 to 7.5 HP 8.0 to 28 LP -0.2 to 7.5 HP 8.0 to 32 LP -0.9 to 7.0 DIFFERENTIAL (bar) RESET DANFOSS NO LP 0.7 to 4.0 Auto/Auto 060-124166 LP 0.7 to 4.0 Auto/Man 060-124366 LP 0.7 to 4.0 Adjustable 060-126166 LP 0.7 Fixed Adjustable 060-126166 66 Head Office 01543 437 010

Ranco Thermostats E070 016-6901 Room -18 to +13 1.5K E071 016-6902 Room -5 to +25 1.5K E072 016-6903 Room +10 to +40 1.5K E075 016-6922 Straight -18 to +13 1.7 to 12K E076 016-6924 Straight -5 to +25 1.7 to 12K E077 016-6950 Coiled -35 to -7 1.7 to 12K E078 016-6951 Coiled -18 to +13 1.7 to 12K E079 016-6954 Coiled -5 to +25 1.7 to 12K Room Straight E080 016-6980 Cross Ambient -18 to +13 1.7 to 12K E081 016-6981 Cross Ambient -5 to +25 1.7 to 12K E082 016-6983 Cross Ambient +10 to +40 1.7 to 12K E083 016-6930 Cross Ambient -32 to +34 3 to 22K Coiled Cross Ambient Ranco Ice Bank Control Ice Bank controls make it possible for a relatively small refrigeration system to supply large refrigeration capacity for limited periods of time. Such systems include milk coolers, automatic vending machines, counter dispensers etc. TYPE DESCRIPTION E090 E37-M1156 Ice Bank Control E091 L56-H2001 3m Probe Danfoss Thermostats * DANFOSS NO E830 UT-72 Bulb -1.5M -30 to +30 2.3K 060H1101 E831 UT-73 Bulb -1.5M 0 to +40 2.3K 060H1102 E835 KP-61 Straight - 2M -30 to +15 5.5/23-1.5/7K 060L1100 E836 KP-61 Straight - 5M -30 to +15 5.5/23-1.5/7K 060L1101 E837 KP-61 Coil - 2m -30 to +15 4.5/23-1.2/7K 060L1102 E838 KP-62 Room -30 to +15 1.5 060L1106 E830 & E831 E835 & E836 E837 E838 67

Thermostat and Pressure Switch Accessories Phial Guard TYPE E140 V169 Guard LP HP Pressure Switch Brackets (Flat & Angle) TYPE E141 31696-1 Angle Bracket E142 48129-3 Flat Bracket Pressure Coupler E143 E144 TYPE PCP.1000SV 1.0 metre c/w Core Depressor PCP.1500SV 1.5 metre c/w Core Depressor Everflex Hose Stainless Braid reinforced flexible lines ideal for replacing capillaries where vibration may cause fractures i.e. pressure or oil differential switches. Constructed out of 304 Stainless Steel Braid with a smooth inner lining of Teflon. Female 1/4 flare connections. One end straight and the other end 90 degree elbow. Temperature range -54 Deg.C to +232 Deg.C MODEL OVERALL LENGTH E180 H70AB-6 152 mm E181 H70AB-13 330 mm E182 H70AB-19 483 mm E183 H70AB-25 635 mm E184 H70AB-31 787 mm E185 H70AB-37 940 mm E186 H70AB-49 1245 mm E187 H70AB-60 1524 mm Thermoplastic Hose Triple wall thermoplastic hose to provide an alternative to copper tube, reducing the risk of fracture whilst being simple and easy to assemble. Hoses are suitable for HCFC and HFC s as well as the old CFC s. Rated at 500 bar, -20 to +110 Degrees C. Supplied in 50M coils, 6 mm o.d. x 2 mm i.d. E200 E208 E209 E210 E211 E215 DESCRIPTION 50M coil of 0780C Triple Wall Hose 1/4 Tee Crimp on all arms 1/4 Female Flare 90 o Elbow 1/4 Female Flare Straight Connector Schrader Depressor for above Crimping Tool 68 Head Office 01543 437 010

Aspen Fan Speed Controller Controls head pressure of systems by increasing and reducing the fan speed balancing temperature of the condenser coil. Specification: Cooling Only Condenser temperature coil sensor Max output: 3 Amp Push on connectors Minimum speed adjustment: 230V 50/60 Hz Power Consumption Internal: 8 W E526 DESCRIPTION Aspen Cooling Only Fan Speed Controller Alco Fan Speed Control The FS controls the speed of fan motors according to pressure changes. Make sure the motor is approved by the motor or unit manufacturer for variable speed by means of phase cutting (TRIAC). Suitable for R22, R134a, R407C and R404A. Specification: Supply voltage: 230 VAC (+15%/-20%) 50 or 60 Hz Nominal current: 0.2 to 4 amps Maximum refrigerant temperature: +70 C Permissible ambient temperature: -20 C to +55 C Protection to IP65 Connection: 1/4 female flare to suit access fitting MODEL E525 FSX (Y) - 42-S 69