XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

Similar documents
XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

14 AC x

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

ELITE Series R-410A - Two-Stage Compressor

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

ELITE Series Variable Capacity

2 shp 13 lc 1 36 t - 1 a

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

T S A 048 S 4 N 4 1 T

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

ELITE Series Variable Capacity

T P A 120 S 4 S N 1 Y

T P A 048 S 4 N 4 1 T

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

Visit us at For the latest technical information,

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

MERIT Series R-410A - Upflow / Horizontal

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

CB X 32 mv

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

13 GEP A L P - 1 A

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

RGE 13 A T - 1 A

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

C22 Bulletin # October 1993 Supersedes May 1993

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

C22FC Bulletin # October 1993 Supersedes May 1993

Ruud Achiever Series Air Conditioners

MACH N-407 Heat Pump Air-Cooled Chiller

PACKAGE AIR CONDITIONER

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Lennox 8 Series Single Zone - R-410A

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Split System Cooling Product & Performance Data

complete comfort Heat Pumps

ELITE SERIES Downflow - High Efficiency Blower Motor

Product Data. Fig. 1 - Unit 50VR -A

INSTALLATION INSTRUCTIONS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

The XP21 raises the bar for efficiency and comfort.

HS25 SERVICE UNIT INFORMATION

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Corp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

Transcription:

E N G I N E E R I N G D ATA A I R C O N D I T I O N E R S XC21 DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology Bulletin 210586 June 2011 Supersedes May 2011 SEER up to 21.00 2 to 5 Tons Cooling Capacity - 23,200 to 59,500 Btuh MODEL NUMBER IDENTIFICATION x c 21-036 - 230-5 Refrigerant Type X = R-410A Unit Type C = Air Conditioner Nominal SEER Voltage 230 = 208/230V-1ph-60hz Nominal Cooling Capacity 024 = 2 tons 036 = 3 tons 048 = 4 tons 060 = 5 tons Minor Revision Number

FEATURES Contents System Matches...14 Dimensions...12 Electrical Data...10 Features...2 Field Wiring...11 Installation Clearances...11 Number Identification...1 Optional Accessories...10 Outdoor Sound Data...11 Specifications...10 Sunsource Home Energy System - Components...7 Equipment Warranty Compressor - ten year limited warranty in residential installations and five years in non-residential installations. All other covered components - ten years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. ApplicationS SEER up to 21.00. 2 through 5 ton. Single phase power supply. Sound levels as low as 69 db. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See System Matches. See Indoor Coils and s tab sections for data. Units shipped completely factory assembled, piped, and wired. Each unit is test operated at the factory insuring proper operation. Installer must set air conditioner, connect refrigerant lines, and make electrical connections to complete job. Approvals Certified to Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in accordance with test conditions included in Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated according to U.S. Department of Energy (DOE) test procedures. Air conditioners and components within bonded for grounding to meet safety standards for servicing required by ETL, NEC, and CEC. Units are ETL listed for the US and Canada. ISO 9001 Registered Manufacturing Quality System. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. All models are listed in the GreenSpec Directory, a leading resource of environmentally responsible products. For expanded ratings, see www.lennoxdavenet.com. XC21-2 to 5 Ton Air Conditioner / Page 2 B C I D K H E J G F REFRIGERATION SYSTEM R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table. Outdoor Coil Fan with SilentComfort Technology B A Specially-designed, SilentComfort fan guard uses Passive Vortex Suppression to reduce air noise. Constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel. C Specially designed fan blades reduce operating sound levels. Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor is inherently protected. All models have a variable-speed outdoor fan motor for quiet operation. Motor totally enclosed for maximum protection from weather, dust and corrosion. Fan service access accomplished by removal of fan guard.

D E F G FEATURES Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to insure leakproof construction. Entire coil is accessible for cleaning. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. Hi-Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular-sieve bead type drier. OPTIONS Valve Kits Must be ordered extra and field installed on certain indoor units. See TXV Usage table on page 13. Chatleff style fitting. Freezestat Installs on or near the discharge line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized, and sealed at factory. Suction line fully insulated. L15 lines are stubbed at both ends. See Specifications table for selection. Not available for -060 model and must be field fabricated. H COMPRESSOR Copeland Scroll Ultra Tech Two-Stage Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. On the fixed scroll there are two bypass ports in the first suction pocket. On the outside of the fixed scroll there is a slider ring that is controlled by an internal solenoid that will rotate and cover the bypass ports. When the thermostat calls for first-stage cooling, the bypass ports are open and the compressor operates at 67% capacity, creating more cost-effective and efficient compressor operation. The bypassed refrigerant is returned to the compressor housing through the bypass ports. When the thermostat calls for second-stage cooling, the internal solenoid is energized, the slider ring rotates and covers the bypass ports, and the compressor operates at full capacity. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. XC21-2 to 5 Ton Air Conditioner / Page 3

I FEATURES COMPRESSOR (CONTINUED) Compressor is installed in the unit on specially formulated, resilient rubber mounts for better sound dampening and vibration free operation. Crankcase Heater Crankcase heater prevents migration of liquid refrigerant into compressor and ensures proper compressor lubrication. CONTROLS icomfort Control Advanced control communicates information about various operating parameters in the air conditioner to the optional icomfort Touch Communicating Thermostat to constantly maintain the highest level of comfort, performance and efficiency available. Connections for connecting a conventional heating/cooling thermostat are also provided on the control. Auto Configuration - On start-up the control automatically sends a description of the unit to the optional icomfort Touch Communicating Thermostat to automatically configure the number of stages and features available. Control also features: Compressor anti-short cycle delay. User selectable with communicating thermostat - 1, 2, 3, 4 or 5 minutes. Default setting is 5 minutes. Compressor must operate in first stage a minimum of 5 seconds before second stage operation is permitted. Low voltage protection prevents 2nd stage compressor operation when voltage is not within the specified range. High and low pressure switch monitoring with provisions for lockout. Five-Strike lockout protection protects compressor. Discharge line temperature and sensor monitoring. Lennox Humiditrol Whole Home Dehumidification System (EDA) compatible. EEPROM storage of all local configurations. Lennox Systems Operations Monitor (icomfort Control Feature) Onboard Lennox Systems Operations Monitor (LSOM) provides detailed information for proper preventative maintenance and fast, easy servicing. Displays the most common fault conditions (electrical and mechanical) through the icomfort Touch Communicating Thermostat or through the ALERT and TRIP lights on the control. ALERT LED (yellow) - communicates an abnormal system condition through a unique flash code. The ALERT LED will flash a number of times consecutively, pause and then repeat the process. The number of consecutive flashes, defined as the Flash Code, correlates to a particular abnormal condition. The codes can indicate one of the following: long run time, system pressure trip (discharge or suction pressure out-of-limits or compressor overloaded), short cycling, locked rotor, open circuit, open start circuit (current present only in run circuit), open run circuit (current present only in start circuit), welded contactor (compressor runs continuously), or low voltage (control circuit < 17VAC). TRIP LED (red) - indicates there is a demand signal from the thermostat but no current to the compressor is detected by the monitor. OPTIONS Compressor Low Ambient Cut-Off Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35 F. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally does not need a potential relay and start capacitor. In conditions such as low voltage, kit may be required to increase the compressor starting torque. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. Required if outdoor unit is used with a conventional heating-cooling thermostat and air handler (not icomfort control). See furnace or air handler specifications to determine if relay is needed. Indoor Blower Speed Relay Kit Relay kit provides optimum humidity control conditions by automatically reducing indoor blower speed during continuous fan or first-stage compressor operation. Low Ambient Kit Air conditioner will operate satisfactorily down to 45 F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F. A Freezestat should be installed on compressors equipped with a low ambient kit. A Compressor Low Ambient Cut-Off should be added to terminate compressor operation below recommended operation conditions. XC21-2 to 5 Ton Air Conditioner / Page 4

FEATURES CONTROLS (CONTINUED) icomfort Touch Communicating Thermostat (part of the icomfort Residential Communicating Control System) The icomfort Touch Communicating Thermostat recognizes and connects to all icomfort enabled products to automatically configure and control the system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Also recognizes model and serial number information for icomfort -enabled products to simplify installation. Large full color touchscreen - no hidden buttons or doors. A simple easy-to-use menu-driven touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed in simple English on thermostat screen. Conventional products (not icomfort -enabled) can easily be added and controlled by the icomfort Touch Communicating Thermostat. A tabbed interface lists all programming options on the screen. Installer setup screens allow quick and simple system configuration without a manual, Installer can also run tests on complete system or individual components for easy maintenance and troubleshooting. Serial communications bus (RSBus), with less wiring than a conventional heating/cooling system, allows system communication. Uses 4-wire, 18-gauge standard thermostat wiring. See the icomfort Touch Communicating Thermostat Engineering Handbook bulletin in the Controls section for more information. Discharge Air Temperature Sensor Used with icomfort Touch Communicating Thermostat. When installed in the supply air plenum, the discharge air temperature sensor allows the icomfort Touch Communicating Thermostat to control low and high stage heating temperatures. Sensor is auto-detected when connected to thermostat. ComfortSense 7000 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual-fuel and Humiditrol applications. See the ComfortSense 7000 Engineering Handbook bulletin in the Controls section for more information. Outdoor Temperature Sensor Used with icomfort Touch Communicating Thermostat and ComfortSense 7000 thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. NOTE - Sensor is required for Humiditrol applications. Thermostat Thermostat (icomfort Touch Communicating Thermostat, or programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. MODE SCHED HOME SCHEDULE OPTIONS AUTO ON INDOOR RH 26% WED AN 21 12:35AM SET AT HEAT SET AT COOL XC21-2 to 5 Ton Air Conditioner / Page 5

J K FEATURES Cabinet Heavy-gauge steel construction Pre-painted cabinet finish. Painted base section. Compressor and control box located in a separate compartment, insulated with thick fiberglass insulation. Compartment provides protection from the weather and keeps sound transmission at a minimum. Control box is conveniently located with all controls factory wired. Large removable panel provides service access. Drainage holes are provided in base section for moisture removal. High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture. SmartHinge Louvered Coil Protection Steel louvered panels provides complete coil protection. Panels are hinged to allow easy cleaning and servicing of coils. Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet. Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections. See dimension drawing. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Suction and liquid line service valves and gauge ports are located inside the cabinet. Refrigerant line connections and field wiring inlets are located in one central area of the cabinet. See dimension drawing. XC21-2 to 5 Ton Air Conditioner / Page 6

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS Solar Modules Future Modules Standard Outlet Communication Gateway Broadband Internet Connection Performance Monitoring Website SYSTEM OVERVIEW All Dave Lennox Signature Collection air conditioners and heat pumps are equipped at the factory for upgrading to the SunSource Home Energy System. Units can be upgraded at the time of installation or in the future. Solar energy is first used to meet cooling/heating demands. When the cooling/heating system is not operating, the system powers lighting, appliances and other electronic devices in the home. And in some locations, any surplus power is sent back to the utility company for a possible credit (check with your local utility company for availability). The SolarSync Package consists of the following components: Lennox Solar Subpanel field installed in a Dave Lennox Signature Collection air conditioner or heat pump unit. Solar Modules (1 to 15 may be used to vary the amount of electricity generated). Envoy Communications Gateway that monitors home energy usage. All components must be ordered separately. Wiring from the roof mounted solar modules is routed to the outdoor unit. From there power travels to the home electrical service panel using the existing outdoor unit power wiring. NOTE - Refer to separate Engineering Handbook Bulletin for the SunSource Home Energy System for more detailed information. See section Solar - Kits/ Accessories. Also refer to SunSource Home Energy System Applications and Design Guidelines Manual (Corp. 1021-L3) for complete information on designing, sizing and installing a complete system. APPROVALS Air Conditioner or Heat Pump Unit Electrical Panel The SunSource Home Energy System meets the requirements for federal tax credits listed under the U.S. Emergency Economic Stabilization Act of 2008, covering 30% of the cost of the solar modules, including installation. LENNOX SOLAR SUBPANEL The Lennox Solar Subpanel replaces the factory piping panel on the outdoor unit and provides circuit breaker protection and power entry for both HVAC (line) and solar power wiring. Subpanel is equipped with separate circuit breakers for both HVAC (line) voltage and solar power. Equipped with pigtail connections for easy field wiring. Subpanel is an ETL listed accessory. Split design (upper/lower panel) allows installation on different size outdoor units. Subpanel is furnished with three separate lower panels. See Outdoor Unit Usage table for correct lower panel size. Note - Subpanel is not backwards compatible with older Dave Lennox Signature Collection outdoor units. Disconnects for HVAC (line) and solar power wiring are not furnished and must be field provided. SOLAR MODULES Converts solar energy into electricity. Built-in racking hardware, wiring, grounding and microinverters. Microinverters produce AC power synchronized to the utility grid. Modules operate independently from each other allowing modules that are not shaded or dirty to operate with optimum performance. Racking system is built-in to the module frame. Painted flat black frame. Solar modules are available in packages of four or thirteeen. Solar modules are UL listed, CSA certified and meet National Electrical Code requirements. XC21-2 to 5 Ton Air Conditioner / Page 7

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS SOLAR MODULES (CONTINUED) Roof Mounting Kits Several roof mounting kits for mounting Solar Modules are available for a variety of different roof styles. Composition (Asphalt) Shingle Roof Mounting Kit (4 or 13 pack) Kit includes: (6 each) Composition flashing mounts, serrated L-brackets, solar module splices, serrated T-bolts, flange nuts, lag bolts, fender washers, (2) wire spring clips, (1) ground lug w/screw, (1) installation wrench. S or Barrel Tile Roof Mounting Kit (4-pack) Kit includes: (6 each) S/Barrel tile mounts, mount foots, 6 in. aluminum posts, serrated L-brackets, solar module splices, serrated T-bolts, flange nuts, washers, hex bolts, (2) Wire spring clips, (1) ground lug w/screw, (1) installation wrench. Flat (Cement) Tile Roof Mounting Kit (4-pack) Kit includes: (6 each) flat tile bracket, universal tile bracket, solar module splices, T-bolts, (36) flange nuts, (12) fender washers, (12) washers, (12) lag bolts, (2) wire spring clips, (1) ground lug w/screw, (1) installation wrench. Standing Seam Roof Mounting Kit (4-pack) Kit includes: (8 each) S-5! standing seam clamps, flip clips, mounting spacers, hex bolts, (6) solar module splices, (2) wire spring clips, (1) ground lug w/screw, (1) installation wrench. Installation Kits and Tools AC System Kit (Required - One per each outdoor unit) Kit includes interconnection cable required to connect the field installed wiring from the solar modules to the outdoor unit. Also includes the end cap to place on the last microinverter connection in the row. One kit required per outdoor unit. Kit contains 6 ft. AC interconnection cable and end cap. AC 6 Foot Extension Cable Six foot extension cable for connecting one row of modules to the next if they are further than the standard interconnection cable can reach (second row above or below, etc.). Only required for multiple rows. Rooftop Junction Box Flash mounted rooftop junction box is used to transition from interconnection cable to wiring/conduit to the outside HVAC unit. Use one for each outdoor unit. Professional Installer Tool Kit Installer tools to aid in installation. Includes driver to tighten splices with ratchet from opposite side of module (in place of wrench) and step block to support module while until splices and mounting points are installed. Includes (2) Splice Drivers and (2) Step Blocks. Solar Module Splices Required if installing a second row of solar modules above or below an existing row or adding additional 4 packs of modules end to end. Splices used in top and bottom applications are not a grounding component and only act as a rigid attachment to support the upper or lower module frame of the second row to the module frame of the existing row. Allows for fewer roof penetrations by supporting the upper and lower solar modules in a two-row application with a common roof mount in-between. Kit contains 10 splices. SYSTEM MONITORING Envoy Communications Gateway The Envoy Communications Gateway monitors microinverter (on solar modules) performance and can be connected to a broadband internet connection to send data to the Enphase Enlighten web site for online monitoring by the homeowner. The Envoy Communications Gateway is not required, but must be used if system performance monitoring is desired. System monitoring is also available locally with the Envoy Communications Gateway and a personal computer if no internet connection is available. Various Event Messages are also available when monitoring the system via a personal computer locally. Contents - (1) Envoy Communications Gateway, (1) 6 ft. power cord, (1) 10 ft. Ethernet cable. CSA (US/C) listed. Enphase Enlighten Performance Monitoring Website Powered by the Envoy Communications Gateway, the Enphase Enlighten Performance Monitoring website allows the homeowner to keep track of home energy usage and see environmental benefits in real time. See demos, view reference installations and other additional information at: http://enlighten.enphaseenergy.com/ Communications Booster Ethernet bridge signal booster for the Envoy Communications Gateway. Booster is only needed if the communications gateway is installed and signal is not strong enough in the installed location. Allows the unit to be plugged into an outlet closer to the distribution panel, yet still plug into the broadband router. XC21-2 to 5 Ton Air Conditioner / Page 8

SUNSOURCE HOME ENERGY SYSTEM - COMPONENTS Description OUTDOOR UNIT COMPONENTS Lennox Solar Subpanel (see table below for lower subpanel usage) SOLAR COMPONENTS Solar Module 185 W, single-phase 240 VAC. Weight - 46 lbs. (each module) ROOF MOUNTING KITS FOR SOLAR MODULES Composition (Asphalt) Shingle Flat (Cement) Tile S or Barrel Tile Standing Seam INSTALLATION KITS AND TOOLS AC System Kit (Required - One per each outdoor unit) AC 6 Foot Extension Cable Rooftop Junction Box Professional Installer Tool Kit Solar Module Splices (10-pack) MONITORING CONTROLS Envoy Communications Gateway Communications Booster Catalog Number 67W83 Y3303 (4-pack) Y3452 (13-pack) Dimensions (L x W x D) 62-5/8 x 32-1/4 x 2-3/4 in. (1590 x 819 x 70 mm) Y3306 (4-pack) Y3463 (13-pack) Y3307 (4-pack) Y3308 (4-pack) Y3309 (4-pack) Y3310 Y3313 Y3312 Y3314 Y3311 Y3304 Y3305 LENNOX SOLAR SUBPANEL - OUTDOOR UNIT USAGE Outdoor Unit XC21 (All Sizes) Lower Subpanel Height - in. (mm) 27 (686) X XC21-2 to 5 Ton Air Conditioner / Page 9

SPECIFICATIONS General XC21-024 XC21-036 XC21-048 XC21-060 Data Nominal Tonnage 2 3 4 5 Connections Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 (sweat) Suction line (o.d.) - in. 7/8 7/8 7/8 1-1/8 Refrigerant 1 R-410A charge furnished 11 lbs. 12 oz. 12 lbs. 5 oz. 13 lbs. 0 oz. 13 lbs. 0 oz. Outdoor Coil Outdoor Fan Net face area - sq. ft. Outer coil 27.21 27.21 27.21 27.21 Inner coil 26.36 26.36 26.36 26.36 Tube diameter - in. 5/16 5/16 5/16 5/16 of rows 2 2 2 2 Fins per inch 22 22 22 22 Diameter - in. 26 26 26 26 of blades 5 5 5 5 Motor hp 1/4 1/4 1/4 1/4 Cfm - 1st stage 3030 3350 3825 3825 2nd stage 3500 3845 4230 4230 Rpm - 1st stage 475 525 600 600 2nd stage 550 600 675 675 Watts - 1st stage 70 90 135 135 2nd stage 105 125 185 185 Shipping Data - lbs. - 1 pkg. 314 331 337 357 ELECTRICAL DATA Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 3 Maximum overcurrent protection (amps) 25 35 45 50 2 Minimum circuit ampacity 14.9 23.7 28.5 34.1 Compressor Rated load amps 10.3 16.7 21.2 25.7 Locked rotor amps 52 82 96 118 Power factor 0.98 0.98 0.98 0.98 Outdoor Fan Motor - Full load amps 2.8 2.8 2.8 2.8 CONTROLS icomfort Touch Communicating Thermostat 49W95 49W95 49W95 49W95 4 Remote Outdoor Sensor (for Humiditrol ) X2658 X2658 X2658 X2658 5 Discharge Temperature Sensor 88K38 88K38 88K38 88K38 ComfortSense 7000 Thermostat Y0349 Y0349 Y0349 Y0349 Remote Outdoor Sensor (for Humiditrol ) X2658 X2658 X2658 X2658 OPTIONAL ACCESSORIES - MUST BE ORDERED EXTRA Compressor Hard Start Kit 10J42 81J69 Compressor Low Ambient Cut-Off 45F08 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Speed Relay Kit 40K58 Low Ambient Kit 68M04 Refrigerant Line Sets L15-65-30 L15-65-40 L15-65-50 Field Fabricate Indoor Blower Off Delay Relay 58M81 NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. 2 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 HACR type breaker or fuse. 4 Remote Outdoor Sensor may be used with an icomfort -enabled outdoor unit for a secondary (alternate) sensor reading. Sensor may also be used with a conventional XC21-2 to 5 Ton Air Conditioner / Page 10

OUTDOOR SOUND DATA 1 Unit Octave Band Sound Power Levels dba, re 10-12 Watts Center Frequency - HZ 63 125 250 500 1000 2000 4000 8000 XC21-024 48.5 54.5 61 64 62 60 56 49 69 XC21-036 49 60 65 66.5 64.5 61.5 56.5 50 71 XC21-048 49.5 59.5 66.5 68 67 63 58 52 73 XC21-060 50 60 65.5 70 68.5 64 57 50.5 73 NOTE - the octave sound power data does not include tonal correction. 1 Tested according to Standard 270-2008 test conditions. 1 Sound Rating Number (db) INSTALLATION CLEARANCES - INCHES (MM) NOTES - One of these three sides must be 36 in. (914 mm). One of the two remaining sides may be 12 in. (305 mm). The remaining side may be 6 in. (152 mm). Service Clearance 30 in. (762 mm) See Notes See Notes Service See Notes 48 in. (1219 mm) clearance required on top of unit 24 in. (610 mm) required between two units See Notes FIELD WIRING DISCONNECT SWITCH (By Others) B THERMOSTAT (Optional) D DISCONNECT SWITCH (By Others) A A - Two Wire Power (not furnished) B - Two Power (not furnished) See Electrical Data C - Four Wire Low Voltage (not furnished) 18 ga. minimum D - Six Wire Low Voltage (not furnished) 18 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. LENNOX AIR CONDITIONER C LENNOX HEATING UNIT OR AIR HANDLER UNIT XC21-2 to 5 Ton Air Conditioner / Page 11

DIMENSIONS - INCHES (MM) UNIT SUPPORT FEET 16 7/8 (429) 26 7/8 (683) 8 3/4 (222) 3 1/8 (79) 30 3/4 (781) TOP VIEW BASE SECTION 3 3/4 (95) 4 5/8 (117) TOP VIEW 39 1/2 (1003) 35 1/2 (902) DISCHARGE AIR SUCTION LINE INLET 47 (1194) 4 1/2 (114) ELECTRICAL INLETS LIQUID LINE INLET 18 1/2 (470) 8 (203) 1 (25) SIDE VIEW ACCESS VIEW XC21-2 to 5 Ton Air Conditioner / Page 12

TXV USAGE XC21-024 XC21-036 XC21-048 XC21-060 Order 37L51 37L51 91M02 91M02 CX34 upflow coils and all Lennox air handlers (except CB26UH R ) are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the TXV SUBSTITUTIONS table. The correct TXV must be ordered and field installed. C33 coils and all horizontal and downflow coils are shipped without a TXV. The TXV must be ordered and field installed. MOST POPULAR MATCHES Outdoor Unit XC21-024 XC21-036 XC21-048 XC21-060 Indoor Unit No CBX32MV-036 CBX32MV-048 CBX32MV-048 CBX32MV-060 *TXV SUBSTITUTIONS Indoor Coils/s with factory installed expansion valves that require field replacement Indoor Air Handler Order XC21-024 C33-44 37L51 XC21-024 CBX32M-042 37L51 XC21-024 CX34-42 37L51 XC21-036 C33-44 37L51 XC21-036 CBX27UH-036 37L51 XC21-036 CBX27UH-042 37L51 XC21-036 CBX32M-042 37L51 XC21-036 CBX32M-048 37L51 XC21-036 CBX32MV-048 37L51 XC21-036 CBX40UHV-042 37L51 XC21-036 CBX40UHV-048 37L51 XC21-036 CX34-42 37L51 XC21-036 CX34-44/48 37L51 XC21-036 CX34-49 37L51 XC21-036 CX34-50/60C 37L51 XC21-036 CX34-62 37L51 XC21-048 CBX32M-036 91M02 XC21-048 CBX32MV-036 91M02 XC21-048 CBX40UHV-036 91M02 XC21-048 CX34-44/48 91M02 XC21-060 CX34-44/48 91M02 *Factory installed expansion valve on the indoor coil or air handler shown must be replaced with the expansion valve listed (ordered separately). XC21-2 to 5 Ton Air Conditioner / Page 13

XC21-2 to 5 Ton Air Conditioner / Page 14 XC21-024-230 TXV 24,800 19.50 13.50 C33-19 O23V2/3-70/90 4261043 XC21-024-230 TXV 24,000 18.20 13.50 C33-24 CBWMV-24B-040 4261041 XC21-024-230 TXV 24,200 18.50 13.50 C33-24 G61MPV-36B-045 4260984 XC21-024-230 TXV 24,200 18.50 13.50 C33-24 G61MPV-36B-070 4261033 XC21-024-230 TXV 24,400 18.70 13.50 C33-24 G61MPV-36B-071 4261034 XC21-024-230 TXV 24,200 18.70 13.70 C33-24 G61MPV-36C-090 4261035 XC21-024-230 TXV 24,200 19.00 13.70 C33-24 SL280UH070V36A 4261036 XC21-024-230 TXV 24,200 19.00 13.70 C33-24 SL280UH070XV36A 4261040 XC21-024-230 TXV 24,800 19.00 13.70 C33-24 SL280UH090V36B 4261037 XC21-024-230 TXV 24,000 18.00 13.50 C33-24 SL280UH090V48B 4261042 XC21-024-230 TXV 24,400 18.70 13.70 C33-24 SLP98UH070V36B 4261039 XC21-024-230 TXV 24,400 18.70 13.70 C33-24 SLP98UH090V36C 4261038 XC21-024-230 TXV 23,600 16.00 12.20 C33-24 4260807 XC21-024-230 TXV 25,600 20.00 14.20 C33-25 G61MPV-36B-045 4260986 XC21-024-230 TXV 25,600 20.00 14.50 C33-25 G61MPV-36B-070 4260987 XC21-024-230 TXV 25,600 20.20 14.20 C33-25 G61MPV-36B-071 4260988 XC21-024-230 TXV 25,200 20.00 13.70 C33-25 O23V2/3-70/90 4260989 XC21-024-230 TXV 25,600 20.00 14.20 C33-25 SL280UH070V36A 4260990 XC21-024-230 TXV 25,600 20.00 14.20 C33-25 SL280UH070XV36A 4260992 XC21-024-230 TXV 26,000 20.50 14.70 C33-25 SL280UH090V36B 4260985 XC21-024-230 TXV 25,400 19.50 14.20 C33-25 SL280UH090V48B 4260993 XC21-024-230 TXV 25,800 20.20 14.70 C33-25 SLP98UH070V36B 4260991 XC21-024-230 TXV 25,000 17.00 13.00 C33-25 4260812 XC21-024-230 TXV 24,800 18.70 13.70 C33-30 G61MPV-36B-045 4260996 XC21-024-230 TXV 24,800 19.00 13.70 C33-30 G61MPV-36B-070 4260997 XC21-024-230 TXV 24,800 19.00 13.70 C33-30 G61MPV-36B-071 4260998 XC21-024-230 TXV 24,600 19.00 14.00 C33-30 G61MPV-36C-090 4260999 XC21-024-230 TXV 24,400 18.70 13.20 C33-30 O23V2/3-70/90 4261000 XC21-024-230 TXV 24,800 19.20 14.00 C33-30 SL280UH070V36A 4260994 XC21-024-230 TXV 24,800 19.20 14.00 C33-30 SL280UH070XV36A 4261003 XC21-024-230 TXV 25,200 19.20 14.00 C33-30 SL280UH090V36B 4260995 XC21-024-230 TXV 24,800 19.00 13.70 C33-30 SLP98UH070V36B 4261001 XC21-024-230 TXV 24,800 19.20 14.00 C33-30 SLP98UH090V36C 4261002 XC21-024-230 TXV 24,200 16.20 12.50 C33-30 4260808 XC21-024-230 TXV 26,000 20.20 14.50 C33-31 G61MPV-36B-045 4261005 XC21-024-230 TXV 26,000 20.20 14.70 C33-31 G61MPV-36B-070 4261006 XC21-024-230 TXV 26,200 20.50 14.50 C33-31 G61MPV-36B-071 4261044 XC21-024-230 TXV 25,800 20.20 14.20 C33-31 O23V2/3-70/90 4261045 XC21-024-230 TXV 26,200 20.70 14.70 C33-31 SL280UH070V36A 4261004 XC21-024-230 TXV 26,200 20.70 14.70 C33-31 SL280UH070XV36A 4261047 XC21-024-230 TXV 26,200 20.00 14.50 C33-31 SL280UH090V36B 4261052 XC21-024-230 TXV 25,800 19.70 14.50 C33-31 SL280UH090V48B 4261048 XC21-024-230 TXV 26,200 20.50 14.70 C33-31 SLP98UH070V36B 4261046 XC21-024-230 TXV 25,400 17.20 13.00 C33-31 4260809 XC21-024-230 TXV 25,200 19.50 14.50 C33-36 CBWMV-36B-070 4261014 XC21-024-230 TXV 25,400 19.70 14.50 C33-36 CBWMV-36C-090 4261023 XC21-024-230 TXV 25,600 19.70 14.20 C33-36 G61MPV-36B-045 4261051 XC21-024-230 TXV 25,400 20.00 14.20 C33-36 G61MPV-36B-070 4261007 XC21-024-230 TXV 25,600 20.00 14.20 C33-36 G61MPV-36B-071 4261008 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table.

XC21-024-230 TXV 25,400 20.00 14.50 C33-36 G61MPV-36C-090 4261009 XC21-024-230 TXV 25,200 19.70 13.70 C33-36 O23V2/3-70/90 4261010 XC21-024-230 TXV 25,600 20.20 14.50 C33-36 SL280UH070V36A 4261049 XC21-024-230 TXV 25,600 20.20 14.50 C33-36 SL280UH070XV36A 4261013 XC21-024-230 TXV 26,000 20.20 14.70 C33-36 SL280UH090V36B 4261050 XC21-024-230 TXV 25,200 19.20 14.20 C33-36 SL280UH090V48B 4261024 XC21-024-230 TXV 25,600 20.00 14.50 C33-36 SLP98UH070V36B 4261011 XC21-024-230 TXV 25,600 20.20 14.50 C33-36 SLP98UH090V36C 4261012 XC21-024-230 TXV 24,800 16.70 12.70 C33-36 4260813 XC21-024-230 TXV 26,400 20.20 14.70 C33-38 G61MPV-36B-045 4261027 XC21-024-230 TXV 26,200 20.50 14.70 C33-38 G61MPV-36B-070 4261028 XC21-024-230 TXV 26,400 20.50 14.70 C33-38 G61MPV-36B-071 4261029 XC21-024-230 TXV 26,000 20.20 14.20 C33-38 O23V2/3-70/90 4261030 XC21-024-230 TXV 26,400 20.70 15.00 C33-38 SL280UH070V36A 4261025 XC21-024-230 TXV 26,400 20.70 15.00 C33-38 SL280UH070XV36A 4261032 XC21-024-230 TXV 26,800 20.70 15.00 C33-38 SL280UH090V36B 4261026 XC21-024-230 TXV 26,000 20.00 14.50 C33-38 SL280UH090V48B 4261015 XC21-024-230 TXV 26,400 20.50 15.00 C33-38 SLP98UH070V36B 4261031 XC21-024-230 TXV 25,600 17.20 13.20 C33-38 4260811 XC21-024-230 TXV 25,600 19.70 14.20 C33-42 G61MPV-36B-045 4261017 XC21-024-230 TXV 25,400 20.00 14.20 C33-42 G61MPV-36B-070 4261018 XC21-024-230 TXV 25,600 20.00 14.20 C33-42 G61MPV-36B-071 4261019 XC21-024-230 TXV 25,200 19.70 13.70 C33-42 O23V2/3-70/90 4261020 XC21-024-230 TXV 26,000 20.20 14.70 C33-42 SL280UH090V36B 4261016 XC21-024-230 TXV 25,200 19.20 14.20 C33-42 SL280UH090V48B 4261022 XC21-024-230 TXV 25,600 20.00 14.50 C33-42 SLP98UH070V36B 4261021 XC21-024-230 TXV 24,800 16.70 12.70 C33-42 4260810 XC21-024-230 TXV 25,800 19.50 14.70 CBX27UH-024 4260915 XC21-024-230 TXV 26,000 20.70 15.00 CBX27UH-030 4260916 XC21-024-230 TXV 24,800 17.00 13.00 CBX32M-018/024 4260906 XC21-024-230 TXV 25,400 17.70 13.50 CBX32M-030 4260907 XC21-024-230 TXV 25,400 17.50 13.50 CBX32M-036 4260908 XC21-024-230 TXV 25,400 19.00 14.00 CBX32MV-018/024 4260909 XC21-024-230 TXV 25,800 19.50 14.50 CBX32MV-024/030 4260910 XC21-024-230 TXV 26,400 21.00 14.70 CBX32MV-036 4260911 XC21-024-230 TXV 26,000 20.50 14.70 CBX40UHV-024 4260912 XC21-024-230 TXV 26,000 20.20 14.70 CBX40UHV-030 4260913 XC21-024-230 TXV 26,800 20.70 15.20 CBX40UHV-036 4260914 XC21-024-230 TXV 23,800 18.20 13.50 CH23-21 G61MPV-36B-045 4260859 XC21-024-230 TXV 23,800 18.50 13.50 CH23-21 G61MPV-36B-070 4260860 XC21-024-230 TXV 23,800 18.50 13.50 CH23-21 G61MPV-36B-071 4260861 XC21-024-230 TXV 23,800 18.70 13.50 CH23-21 SL280UH070V36A 4260858 XC21-024-230 TXV 23,800 18.70 13.50 CH23-21 SL280UH070XV36A 4260954 XC21-024-230 TXV 23,600 18.00 13.20 CH23-21 SL280UH090V48B 4260975 XC21-024-230 TXV 23,800 18.50 13.50 CH23-21 SLP98UH070V36B 4260935 XC21-024-230 TXV 23,200 15.50 12.00 CH23-21 4260791 XC21-024-230 TXV 24,000 18.70 13.70 CH23-31 G61MPV-36B-045 4260863 XC21-024-230 TXV 24,000 19.00 13.70 CH23-31 G61MPV-36B-070 4260864 XC21-024-230 TXV 24,200 19.00 13.70 CH23-31 G61MPV-36B-071 4260865 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table. XC21-2 to 5 Ton Air Conditioner / Page 15

XC21-2 to 5 Ton Air Conditioner / Page 16 XC21-024-230 TXV 24,000 19.00 14.00 CH23-31 G61MPV-36C-090 4260866 XC21-024-230 TXV 24,200 19.20 14.00 CH23-31 SL280UH070V36A 4260862 XC21-024-230 TXV 24,200 19.20 14.00 CH23-31 SL280UH070XV36A 4260955 XC21-024-230 TXV 23,800 18.50 13.50 CH23-31 SL280UH090V48B 4260976 XC21-024-230 TXV 24,200 19.00 14.00 CH23-31 SLP98UH070V36B 4260936 XC21-024-230 TXV 24,200 19.20 14.00 CH23-31 SLP98UH090V36C 4260937 XC21-024-230 TXV 23,400 15.70 12.00 CH23-31 4260792 XC21-024-230 TXV 25,600 19.70 14.20 CH23-41 G61MPV-36B-045 4260869 XC21-024-230 TXV 25,600 19.70 14.50 CH23-41 G61MPV-36B-070 4260870 XC21-024-230 TXV 25,600 20.00 14.20 CH23-41 G61MPV-36B-071 4260871 XC21-024-230 TXV 25,400 20.00 14.50 CH23-41 G61MPV-36C-090 4260872 XC21-024-230 TXV 25,600 20.20 14.50 CH23-41 SL280UH070V36A 4260867 XC21-024-230 TXV 25,600 20.20 14.50 CH23-41 SL280UH070XV36A 4260956 XC21-024-230 TXV 26,000 20.20 14.70 CH23-41 SL280UH090V36B 4260868 XC21-024-230 TXV 25,200 19.20 14.20 CH23-41 SL280UH090V48B 4260977 XC21-024-230 TXV 25,600 20.00 14.50 CH23-41 SLP98UH070V36B 4260938 XC21-024-230 TXV 25,600 20.00 14.50 CH23-41 SLP98UH090V36C 4260939 XC21-024-230 TXV 24,800 16.70 12.70 CH23-41 4260793 XC21-024-230 TXV 25,600 19.70 14.20 CH23-51 G61MPV-36B-045 4260875 XC21-024-230 TXV 25,600 20.00 14.50 CH23-51 G61MPV-36B-070 4260876 XC21-024-230 TXV 25,800 20.00 14.50 CH23-51 G61MPV-36B-071 4260877 XC21-024-230 TXV 25,600 20.00 14.50 CH23-51 G61MPV-36C-090 4260878 XC21-024-230 TXV 25,600 20.20 14.50 CH23-51 SL280UH070V36A 4260873 XC21-024-230 TXV 25,600 20.20 14.50 CH23-51 SL280UH070XV36A 4260957 XC21-024-230 TXV 26,000 20.00 14.70 CH23-51 SL280UH090V36B 4260874 XC21-024-230 TXV 25,400 19.50 14.20 CH23-51 SL280UH090V48B 4260978 XC21-024-230 TXV 25,800 20.00 14.70 CH23-51 SLP98UH070V36B 4260940 XC21-024-230 TXV 25,800 20.20 14.70 CH23-51 SLP98UH090V36C 4260941 XC21-024-230 TXV 25,000 16.70 13.00 CH23-51 4260794 XC21-024-230 TXV 25,200 20.00 14.20 CH33-19 SL280UH070V36A 4260879 XC21-024-230 TXV 25,200 20.00 14.20 CH33-19 SL280UH070XV36A 4260958 XC21-024-230 TXV 24,400 16.50 12.50 CH33-19 4260795 XC21-024-230 TXV 25,000 19.50 14.00 CH33-24/30 SL280UH070V36A 4260880 XC21-024-230 TXV 25,000 19.50 14.00 CH33-24/30 SL280UH070XV36A 4260959 XC21-024-230 TXV 24,400 16.50 12.50 CH33-24/30 4260796 XC21-024-230 TXV 25,600 19.70 14.20 CH33-25 G61MPV-36B-045 4260883 XC21-024-230 TXV 25,600 20.00 14.50 CH33-25 G61MPV-36B-070 4260884 XC21-024-230 TXV 25,600 20.00 14.20 CH33-25 G61MPV-36B-071 4260885 XC21-024-230 TXV 25,800 20.20 14.50 CH33-25 SL280UH070V36A 4260881 XC21-024-230 TXV 25,800 20.20 14.50 CH33-25 SL280UH070XV36A 4260960 XC21-024-230 TXV 25,800 20.00 14.50 CH33-25 SL280UH090V36B 4260882 XC21-024-230 TXV 25,200 19.20 14.20 CH33-25 SL280UH090V48B 4260979 XC21-024-230 TXV 25,600 20.00 14.50 CH33-25 SLP98UH070V36B 4260942 XC21-024-230 TXV 25,000 17.00 13.00 CH33-25A 4260797 XC21-024-230 TXV 24,800 16.70 12.70 CH33-25B 4260798 XC21-024-230 TXV 26,200 20.20 14.70 CH33-31 G61MPV-36B-045 4260888 XC21-024-230 TXV 26,200 20.50 14.70 CH33-31 G61MPV-36B-070 4260889 XC21-024-230 TXV 26,400 20.50 14.70 CH33-31 G61MPV-36B-071 4260890 XC21-024-230 TXV 26,200 20.50 14.70 CH33-31 SL280UH070V36A 4260886 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table.

XC21-024-230 TXV 26,200 20.50 14.70 CH33-31 SL280UH070XV36A 4260961 XC21-024-230 TXV 26,600 20.50 15.00 CH33-31 SL280UH090V36B 4260887 XC21-024-230 TXV 26,000 20.00 14.50 CH33-31 SL280UH090V48B 4260980 XC21-024-230 TXV 26,400 20.50 15.00 CH33-31 SLP98UH070V36B 4260943 XC21-024-230 TXV 25,600 17.20 13.20 CH33-31A 4260799 XC21-024-230 TXV 25,600 17.20 13.20 CH33-31B 4260800 XC21-024-230 TXV 25,400 19.70 14.20 CH33-36 G61MPV-36B-045 4260893 XC21-024-230 TXV 25,400 19.70 14.20 CH33-36 G61MPV-36B-070 4260894 XC21-024-230 TXV 25,600 20.00 14.20 CH33-36 G61MPV-36B-071 4260895 XC21-024-230 TXV 25,600 20.20 14.50 CH33-36 G61MPV-36C-090 4260896 XC21-024-230 TXV 25,400 20.00 14.20 CH33-36 SL280UH070V36A 4260891 XC21-024-230 TXV 25,400 20.00 14.20 CH33-36 SL280UH070XV36A 4260962 XC21-024-230 TXV 25,800 20.00 14.50 CH33-36 SL280UH090V36B 4260892 XC21-024-230 TXV 25,600 20.00 14.50 CH33-36 SLP98UH070V36B 4260944 XC21-024-230 TXV 25,800 20.20 14.70 CH33-36 SLP98UH090V36C 4260945 XC21-024-230 TXV 24,800 17.00 12.70 CH33-36A 4260801 XC21-024-230 TXV 25,200 19.20 14.20 CH33-36B SL280UH090V48B 4260981 XC21-024-230 TXV 24,800 16.70 12.70 CH33-36B 4260802 XC21-024-230 TXV 25,000 17.00 12.70 CH33-36C 4260803 XC21-024-230 TXV 26,000 20.20 14.50 CH33-42 G61MPV-36B-045 4260898 XC21-024-230 TXV 26,000 20.20 14.70 CH33-42 G61MPV-36B-070 4260899 XC21-024-230 TXV 26,200 20.20 14.50 CH33-42 G61MPV-36B-071 4260900 XC21-024-230 TXV 26,400 20.20 15.00 CH33-42 SL280UH090V36B 4260897 XC21-024-230 TXV 25,800 19.70 14.50 CH33-42 SL280UH090V48B 4260982 XC21-024-230 TXV 26,200 20.50 14.70 CH33-42 SLP98UH070V36B 4260946 XC21-024-230 TXV 25,400 17.20 13.00 CH33-42 4260804 XC21-024-230 TXV 26,600 20.50 14.70 CH33-43 G61MPV-36B-045 4260902 XC21-024-230 TXV 26,600 20.70 15.00 CH33-43 G61MPV-36B-070 4260903 XC21-024-230 TXV 26,800 20.70 15.00 CH33-43 G61MPV-36B-071 4260904 XC21-024-230 TXV 26,400 21.00 15.20 CH33-43 G61MPV-36C-090 4260905 XC21-024-230 TXV 26,800 20.70 15.20 CH33-43 SL280UH090V36B 4260901 XC21-024-230 TXV 26,400 20.20 14.70 CH33-43 SL280UH090V48B 4260983 XC21-024-230 TXV 26,800 20.70 15.20 CH33-43 SLP98UH070V36B 4260947 XC21-024-230 TXV 26,600 21.00 15.20 CH33-43 SLP98UH090V36C 4260948 XC21-024-230 TXV 26,000 17.50 13.20 CH33-43B 4260805 XC21-024-230 TXV 25,800 17.50 13.20 CH33-43C 4260806 XC21-024-230 TXV 24,400 18.70 13.50 CR33-24 SL280DF070V36A 4260850 XC21-024-230 TXV 24,400 18.70 13.50 CR33-24 SL280DF090V48B 4260851 XC21-024-230 TXV 23,600 16.00 12.20 CR33-24 4260789 XC21-024-230 TXV 26,000 20.20 14.50 CR33-30/36 G61MPV-36B-045 4260856 XC21-024-230 TXV 25,800 20.20 14.50 CR33-30/36 G61MPV-36B-070 4260852 XC21-024-230 TXV 26,000 20.50 14.50 CR33-30/36 G61MPV-36B-071 4260853 XC21-024-230 TXV 25,800 20.50 14.70 CR33-30/36 G61MPV-36C-090 4260857 XC21-024-230 TXV 26,200 20.20 14.50 CR33-30/36 SL280DF070V36A 4260854 XC21-024-230 TXV 26,200 20.50 14.70 CR33-30/36 SL280DF090V48B 4260855 XC21-024-230 TXV 26,000 20.20 14.70 CR33-30/36 SLP98DF070V36B 4260967 XC21-024-230 TXV 26,000 20.20 14.70 CR33-30/36 SLP98DF090V36C 4260968 XC21-024-230 TXV 25,200 17.20 13.00 CR33-30/36 4260790 XC21-024-230 TXV 24,000 18.20 13.50 CX34-18/24 CBWMV-24B-040 4260964 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table. XC21-2 to 5 Ton Air Conditioner / Page 17

XC21-2 to 5 Ton Air Conditioner / Page 18 XC21-024-230 TXV 24,200 18.50 13.50 CX34-18/24 G61MPV-36B-045 4260814 XC21-024-230 TXV 24,200 18.50 13.50 CX34-18/24 G61MPV-36B-070 4260815 XC21-024-230 TXV 24,400 18.70 13.50 CX34-18/24 G61MPV-36B-071 4260816 XC21-024-230 TXV 24,200 18.70 13.70 CX34-18/24 G61MPV-36C-090 4260817 XC21-024-230 TXV 24,200 19.00 13.70 CX34-18/24 SL280UH070V36A 4260822 XC21-024-230 TXV 24,200 19.00 13.70 CX34-18/24 SL280UH070XV36A 4260949 XC21-024-230 TXV 24,800 19.00 13.70 CX34-18/24 SL280UH090V36B 4260823 XC21-024-230 TXV 24,000 18.00 13.50 CX34-18/24 SL280UH090V48B 4260969 XC21-024-230 TXV 24,400 18.70 13.70 CX34-18/24 SLP98UH070V36B 4260931 XC21-024-230 TXV 24,400 18.70 13.70 CX34-18/24 SLP98UH090V36C 4260925 XC21-024-230 TXV 23,600 16.00 12.20 CX34-18/24 4260782 XC21-024-230 TXV 24,800 19.50 13.50 CX34-19 O23V2/3-70/90 4260917 XC21-024-230 TXV 25,600 20.00 14.20 CX34-25 G61MPV-36B-045 4260819 XC21-024-230 TXV 25,600 20.00 14.50 CX34-25 G61MPV-36B-070 4260820 XC21-024-230 TXV 25,600 20.20 14.20 CX34-25 G61MPV-36B-071 4260821 XC21-024-230 TXV 25,200 20.00 13.70 CX34-25 O23V2/3-70/90 4260918 XC21-024-230 TXV 25,600 20.00 14.20 CX34-25 SL280UH070V36A 4260924 XC21-024-230 TXV 25,600 20.00 14.20 CX34-25 SL280UH070XV36A 4260963 XC21-024-230 TXV 26,000 20.50 14.70 CX34-25 SL280UH090V36B 4260818 XC21-024-230 TXV 25,400 19.50 14.20 CX34-25 SL280UH090V48B 4260970 XC21-024-230 TXV 25,800 20.20 14.70 CX34-25 SLP98UH070V36B 4260926 XC21-024-230 TXV 25,000 17.00 13.00 CX34-25 4260783 XC21-024-230 TXV 24,800 18.70 13.70 CX34-30 G61MPV-36B-045 4260826 XC21-024-230 TXV 24,800 19.00 13.70 CX34-30 G61MPV-36B-070 4260827 XC21-024-230 TXV 24,800 19.00 13.70 CX34-30 G61MPV-36B-071 4260828 XC21-024-230 TXV 24,600 19.00 14.00 CX34-30 G61MPV-36C-090 4260829 XC21-024-230 TXV 24,400 18.70 13.20 CX34-30 O23V2/3-70/90 4260919 XC21-024-230 TXV 24,800 19.20 14.00 CX34-30 SL280UH070V36A 4260824 XC21-024-230 TXV 24,800 19.20 14.00 CX34-30 SL280UH070XV36A 4260950 XC21-024-230 TXV 25,200 19.20 14.00 CX34-30 SL280UH090V36B 4260825 XC21-024-230 TXV 24,800 19.00 13.70 CX34-30 SLP98UH070V36B 4260927 XC21-024-230 TXV 24,800 19.20 14.00 CX34-30 SLP98UH090V36C 4260928 XC21-024-230 TXV 24,200 16.20 12.50 CX34-30 4260784 XC21-024-230 TXV 26,000 20.20 14.50 CX34-31 G61MPV-36B-045 4260832 XC21-024-230 TXV 26,000 20.20 14.70 CX34-31 G61MPV-36B-070 4260833 XC21-024-230 TXV 26,200 20.50 14.50 CX34-31 G61MPV-36B-071 4260834 XC21-024-230 TXV 25,800 20.20 14.20 CX34-31 O23V2/3-70/90 4260920 XC21-024-230 TXV 26,200 20.70 14.70 CX34-31 SL280UH070V36A 4260830 XC21-024-230 TXV 26,200 20.70 14.70 CX34-31 SL280UH070XV36A 4260951 XC21-024-230 TXV 26,200 20.00 14.50 CX34-31 SL280UH090V36B 4260831 XC21-024-230 TXV 25,800 19.70 14.50 CX34-31 SL280UH090V48B 4260971 XC21-024-230 TXV 26,200 20.50 14.70 CX34-31 SLP98UH070V36B 4260929 XC21-024-230 TXV 25,400 17.20 13.00 CX34-31 4260785 XC21-024-230 TXV 25,200 19.50 14.50 CX34-36 CBWMV-36B-070 4260965 XC21-024-230 TXV 25,400 19.70 14.50 CX34-36 CBWMV-36C-090 4260966 XC21-024-230 TXV 25,600 19.70 14.20 CX34-36 G61MPV-36B-045 4260837 XC21-024-230 TXV 25,400 20.00 14.20 CX34-36 G61MPV-36B-070 4260838 XC21-024-230 TXV 25,600 20.00 14.20 CX34-36 G61MPV-36B-071 4260839 XC21-024-230 TXV 25,400 20.00 14.50 CX34-36 G61MPV-36C-090 4260840 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table.

XC21-024-230 TXV 25,200 19.70 13.70 CX34-36 O23V2/3-70/90 4260921 XC21-024-230 TXV 25,600 20.20 14.50 CX34-36 SL280UH070V36A 4260835 XC21-024-230 TXV 25,600 20.20 14.50 CX34-36 SL280UH070XV36A 4260952 XC21-024-230 TXV 26,000 20.20 14.70 CX34-36 SL280UH090V36B 4260836 XC21-024-230 TXV 25,200 19.20 14.20 CX34-36 SL280UH090V48B 4260972 XC21-024-230 TXV 25,600 20.00 14.50 CX34-36 SLP98UH070V36B 4260930 XC21-024-230 TXV 25,600 20.20 14.50 CX34-36 SLP98UH090V36C 4260932 XC21-024-230 TXV 24,800 16.70 12.70 CX34-36 4260786 XC21-024-230 TXV 26,400 20.20 14.70 CX34-38 G61MPV-36B-045 4260843 XC21-024-230 TXV 26,200 20.50 14.70 CX34-38 G61MPV-36B-070 4260844 XC21-024-230 TXV 26,400 20.50 14.70 CX34-38 G61MPV-36B-071 4260845 XC21-024-230 TXV 26,000 20.20 14.20 CX34-38 O23V2/3-70/90 4260922 XC21-024-230 TXV 26,400 20.70 15.00 CX34-38 SL280UH070V36A 4260841 XC21-024-230 TXV 26,400 20.70 15.00 CX34-38 SL280UH070XV36A 4260953 XC21-024-230 TXV 26,800 20.70 15.00 CX34-38 SL280UH090V36B 4260842 XC21-024-230 TXV 26,000 20.00 14.50 CX34-38 SL280UH090V48B 4260973 XC21-024-230 TXV 26,400 20.50 15.00 CX34-38 SLP98UH070V36B 4260933 XC21-024-230 TXV 25,600 17.20 13.20 CX34-38 4260787 XC21-024-230 TXV 25,600 19.70 14.20 CX34-42 G61MPV-36B-045 4260847 XC21-024-230 TXV 25,400 20.00 14.20 CX34-42 G61MPV-36B-070 4260848 XC21-024-230 TXV 25,600 20.00 14.20 CX34-42 G61MPV-36B-071 4260849 XC21-024-230 TXV 25,200 19.70 13.70 CX34-42 O23V2/3-70/90 4260923 XC21-024-230 TXV 26,000 20.20 14.70 CX34-42 SL280UH090V36B 4260846 XC21-024-230 TXV 25,200 19.20 14.20 CX34-42 SL280UH090V48B 4260974 XC21-024-230 TXV 25,600 20.00 14.50 CX34-42 SLP98UH070V36B 4260934 XC21-024-230 TXV 24,800 16.70 12.70 CX34-42 4260788 XC21-036-230 TXV 35,400 18.20 12.70 C33-36 CBWMV-36B-070 4261297 XC21-036-230 TXV 35,400 18.50 13.00 C33-36 CBWMV-36C-090 4261298 XC21-036-230 TXV 35,000 18.00 12.70 C33-36 G61MPV-36B-045 4261279 XC21-036-230 TXV 35,200 18.00 12.70 C33-36 G61MPV-36B-070 4261290 XC21-036-230 TXV 35,000 18.00 12.70 C33-36 G61MPV-36B-071 4261291 XC21-036-230 TXV 35,400 18.50 13.00 C33-36 G61MPV-36C-090 4261292 XC21-036-230 TXV 35,200 18.50 13.20 C33-36 SL280UH090V36B 4261277 XC21-036-230 TXV 35,600 18.20 13.20 C33-36 SL280UH090V48B 4261278 XC21-036-230 TXV 35,600 18.20 13.20 C33-36 SL280UH090XV48B 4261296 XC21-036-230 TXV 35,000 18.20 12.70 C33-36 SLP98UH070V36B 4261293 XC21-036-230 TXV 35,600 18.50 13.00 C33-36 SLP98UH090V36C 4261294 XC21-036-230 TXV 35,400 18.20 13.20 C33-36 SLP98UH090V48C 4261295 XC21-036-230 TXV 36,000 18.70 13.00 C33-36 SLP98UH090V60C 4261299 XC21-036-230 TXV 35,800 18.70 13.20 C33-36 SLP98UH110V60C 4261300 XC21-036-230 TXV 35,000 16.20 12.00 C33-36 4261076 XC21-036-230 TXV 36,800 19.00 13.20 C33-38 CBWMV-36B-070 4261310 XC21-036-230 TXV 36,400 18.70 13.00 C33-38 G61MPV-36B-045 4261304 XC21-036-230 TXV 36,600 18.70 13.20 C33-38 G61MPV-36B-070 4261305 XC21-036-230 TXV 36,400 18.70 13.00 C33-38 G61MPV-36B-071 4261306 XC21-036-230 TXV 36,800 19.00 13.20 C33-38 SL280UH070V36A 4261301 XC21-036-230 TXV 36,800 19.00 13.20 C33-38 SL280UH070XV36A 4261308 XC21-036-230 TXV 36,600 19.20 13.50 C33-38 SL280UH090V36B 4261302 XC21-036-230 TXV 37,000 19.00 13.50 C33-38 SL280UH090V48B 4261303 TXV = Matched with Thermostatic Valve. Ratings are Certified to Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95 F outdoor air temperature, 80 F db / 67 F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and s have time delay capabilities. Other s and Air Also see Valve Kit Usage Table. XC21-2 to 5 Ton Air Conditioner / Page 19