Instruction Manual Model A

Similar documents
User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

INSTALLATION INSTRUCTIONS

Model 4001 Series Single Channel Controller

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Table of Contents. Protective Relays

Temperature Controllers

Pump-Up Controller MODEL 4062

Pump-Down Controller MODEL 4052

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Carbon Monoxide Transmitter

DIGITAL METERS Large Display Temperature Meters Instruction Manual

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

ANALOX 3000 Carbon Monoxide Monitor

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Construction Electrical

FLT93 Installation, Operation and Troubleshooting Guide

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Cable Actuated Sensor Industrial User Scalable VDC Output

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

INTRODUCTION / TABLE OF CONTENTS

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Data Sheet 220 LEVEL MONITOR. Supplied by. .com. Call us on +44 (0)

Cable Actuated Sensor Industrial User Scalable 4 20mA

DCA-ED Direct Current Alarm, Eurocard-style with Display

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

Nov 08 PRODUCT SPECIFICATION SHEET

PT9420 (Extended Range)

Analog Room Pressure Monitor RPC Series

Public Safety DAS Annunciator Panel

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

Programmable Output Dual Relay Quad Relay. (Trip Points, High Alarm, Low Alarm, Failsafe, Non-Failsafe, Normally Open, Normally Closed)

GasSens. Hydrogen Peroxide Monitor. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

vibration switch

SINGLE CHANNEL SYSTEM TWO CHANNEL SYSTEM

F4 Process Controller Installation and Operation Guide

MANUFACTURED BY. Gus Berthold Electric Company 1900 W. Carroll Avenue Chicago, Illinois 60612

CP CP

DE20 INSTRUCTION MANUAL

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Event Detection System (EDS)

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

ESSEX ENGINEERING CORPORATION

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

RKA-LEL Sample Draw Combustible Gas Detector

Software Version 2.01 LEVEL MONITOR MODEL 220

Product Manual SZ1145

Direct Current Alarm USER S MANUAL. May No K by Moore Industries-International, Inc.

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM FX SERIES FLOW SWITCH WITH ADDITIONAL TEMPERATURE SWITCH. Manual Number: FXTX2116-1

RK-04 M2 Transmitter Operator s Manual

MagnaValve Shot Flow Controller

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

GTA 4100R. Dual Processor, Dual Channel Controller Card. Part Number R. Manual Revision v6.30 (updated 10 November 2009)

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Model D12-IR. Digital Gas Transmitter...

Series EDA Electronic Pressure Controller. Specifications - Installation and Operating Instructions

APPLICATION DATA SHEET

APM110 LOW AIR VELOCITY ALARM

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

ECO N DATE DESCRIPTION OF CHANGE CHG

Unipower HPL420. User s Manual. True Motor Power Monitor with... Typical Applications. High Trip Alarm. Low Trip Alarm.

Gas Monitor 1A1 with DSI

INSTALLATION AND OPERATING INSTRUCTIONS

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Ultrasonic Point Level Switches

Frequently asked questions: Intelligent Transmitter Series

Product Manual SZ1144

JENCO ELECTRONICS, LTD.

Toxic Gas Detection. Model F12. Toxic Gas Detection

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

INTRODUCTION / TABLE OF CONTENTS

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

UDC100 Universal Digital Controller Specifications

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Transcription:

706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029

MODEL 18-232A LOOP POWERED ALARM GENERAL DESCRIPTION The DEVAR Model 18-232A LOOP POWERED ALARM is used to monitor a single 4 to 20 ma loop and provide a relay contact output when the input variable becomes too high or too low. The 18-232A requires no external power, as it is powered directly from the 4 to 20 ma input signal, requiring only 4 Volts from the loop for operation. The 18-232A provides, as an output, a set of 3 Amp, single pole double throw relay contacts. The relay is operated in the failsafe mode with the relay coil energized during normal operation and de-energized during alarm. In an addition to the relay output, a red LED, located on the face of the 18-232A, lights up indicating an alarm condition. Alarm action, HI or LO, is selected by means of an internal DIP switch. This DIP switch is also used to select a hysteresis of 1,2,4,6,8 or 16 percent. The alarm trip point is set by means of a multiturn pot, accessible from the face of the 18-232A. As a special feature the 18-232A provides a 0 to 1 Volt trip point voltage between the +CAL and -CAL output terminals. By reading the voltage at this point, the trip point setting is precisely determined, 0 to 1 Volt representing 0 to 100% of input. An optional latching feature can be provided upon request. When the latching feature is provided, a momentary push button switch is added at the top of the 18-232A housing. Once the 18-232A goes into the alarm condition it will remain in the alarm condition until the push button switch is depressed. CONFIGURATION The first step in configuring the 18-232A is the setting of the internal DIP switches. To do this, remove the base plate, which is fastened to the 18-232A housing with two screws. Once the DIP switch is exposed, set the alarm action to HI or LO by using switch positions 1,2,3 and 4 on the DIP switch. See the DIP switch selection table for proper setting of the DIP switches. The amount of hysteresis (or dead band) selected, determines the point at which the 18-232A will come out of the alarm condition. For example, a high alarm set to trip at 12 milliamps with 2% hysteresis will go into the alarm condition at 12 milliamps and come out of the alarm condition at 11.68 milliamps (2% of a 16 ma span equals 0.32 ma). Hysteresis can be set to 1,2,4,6,8 or 16 percent using DIP switch positions 5,6,7 and 8. See the DIP switch selection table for proper setting of the DIP switches. The trip points set by means of a multiturn potentiometer at the face of the 18-232A. Turning the pot from fully counterclockwise to fully clockwise moves the trip point from 4 to 20 ma. The trip point can be set by one of two methods. The first method is to set the input current to the trip level, then adjust the trip point pot until the 18-232A goes into alarm. The second method is quick and easy, and only requires the use of the 0 to 1 Volt output voltage, measured between the +cal and the -cal terminals. When using this method, the 18-232A is connected in a current loop; the output voltage is then adjusted using the trip point pot until the desired trip point is reached. The 0 to 1 volt output voltage corresponds to a trip point of 0 to 100% of the input span. For example, setting the voltage to 0.5 volts sets the trip point to 12 ma. This output voltage can also be used to check the trip point settings of 18-232A alarms after they have been installed in working loops.

FACTORY CALIBRATION 1. Set Input Resistance: Connect an Ohm meter between the input terminals +INPUT and test point TP 1. Adjust internal pot P1 for a resistance of 1057 Ohms. 2. Zero Adjustment: Input 12 ma at terminals +INPUT and -INPUT. Using the external trip point pot, set the voltage between terminals +CAL and -CAL to 0.5 volts. Adjust internal pot P3 until the alarm trips. 3. Test Span: Input 20 ma, turn external trip point pot until alarm trips. Voltage between +CAL and -CAL terminals should be 1 volt. SPECIFICATIONS: GENERAL: 1. Input: 4 to 20 ma 2. Input Voltage drop: 4 Volts @ 20 ma 3. Alarm Action: High or Low (DIP Switch Selectable) 4. Resolution of trip adjustment: 0.1% of span 5. Repeatability: 0.1% of span 6. Minimum Trip Point: 2% of Span 7. Hysteresis: 1,2,4,6,8, or 16% 8. Temperature Effect: 0.01% of Span per F 9. Temperature Range 32 to 140 F RELAY: 1. Contact Arrangement: Single Pole Double Throw 2. Contact Rating: 0.1 Amp Min., 3 Amps Max., 2 Amps Typ. @ 28 VDC or 115 VAC, Resistive Load 3. Contact Material: Fine Silver 4. Breakdown Voltage: 500V RMS across contact gap 5. Minimum Contact Life: 1 Million operations, at 1 Amp, 28 VDC 6. Relay Operation: Coil normally energized, de-energizes on Alarm TRIP SET CALIBRATION VOLTAGE: 1. Output Voltage Range: 0 to 1V, Representing a trip point of 0 to 100% of Span 2. Output Voltage Accuracy: ± 0.075% of Span Typ., ±0.75% of Span Max. (True representation of Trip pt. Current) 3. Trip Point Voltage Change: 0.01% Typ. @ 1% Hysteresis (After switching from HI to LO alarm) 0.04% Max. @ 1% Hysteresis 0.12% Typ. @ 16% Hysteresis 0.60% Max. @ 16% Hysteresis REFERENCE DRAWINGS: 1. Product Description: A515154 2. Dimensions and Field Wiring B515194 3. Schematic C515145 4. Circuit Board Assembly B515146

MOUNTING: SnapTrack Bracket included. (Option -M31S, see Figure 2) OPTIONS: 1. -M31D DIN Rail Mounting Bracket 2. -NE4 NEMA 4X Housing 3. -M42 Water tight ½ NPT Hub (for NE4 Housing) 4. -M37A NEMA 7 Explosion Proof Housing 5. -M36 2 Pipe Mount Kit (for M37A Housing) 6. -M13S Stainless Steel Tag (for M37A Housing) 7. -T Low Temperature (-40 to 140 F) 8. -L Latching Alarm FIGURE 1 WIRING DIAGRAM INPUT (7) +IN 4/20mA + 4/20mA (6) -IN (5) +CAL (4) -CAL (3) N.C. CONTACT (2) POLE (1) N.O. CONTACT + 2 WIRE POWER INPUT TRANSMITTER SUPPLY + + LOAD LOAD RELAY IS SHOWN IN DE-ENERGIZED OR ALARM CONDITION + 0 TO 1 VOLT OUTPUT REPRESENTING 0 TO 100% TRIP + POWER 4 WIRE TRANSMITTER FIGURE 2 GENERAL DIMENSIONS 2.813 1.750 1.125 MODEL 18-232A LOOP POWERED ALARM 3.000 2.500

FIGURE 3 DIP SWITCH CALIBRATION SWITCH ALARM HI LO % DEAD 1 BAND 2 4 6 I ON 8 O 12 16 1 2 3 4 5 6 7 8 O I 3 O I O O I I I I I O O O I O O I O O I O O I O O O O O O O NOTE: Trip Set Voltage is calibrated in the HI alarm mode. For best LO alarm accuracy calibrate in the LO alarm mode.