VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

Similar documents
VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 120 & 121. Arc flash detection units. Product picture

VAMP 121. Arc protection unit. User manual

REA 105 Arc Protection Module. Operator s Manual

AQ 100 Series. Arc Flash Protection System

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Annunciator Unit SACO 16 D1. Product Guide

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N

1. General Safety Block diagram Description of operation Connections Commissioning...11

SENTINEL D - Fault Passage Monitoring

Operation and use. Functions and characteristics

Annunciator unit. Application

SENTINEL A - Fault Passage Indicator

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

Delivering reliable power for patient safety

Analog Annunciator Unit SACO 16 A3. Product Guide

D1000 Arc-fault Protection System

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Arc Fault Protection System D1000

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Instructions for the fan motor control system with integrated wiring terminals SILVER C

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Rules for Intruder Alarm Systems

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Universal fault annunciator for panel mounting

RTO. User guide 05/

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

INPUT / OUTPUT MINI MODULES

02/11/2015

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Audible warning devices for external alarm

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

INTERNATIONAL STANDARD

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

M2000 Engine Controller

CIRCUIT BREAKER FAIL PROTECTION

Remote NAC Power Supply D7038

Intelligent metering and control devices. Typical applications. Features. Measure and control energy costs. Improve power quality and reliability

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Product Guide Low Voltage Switchboard & Switchgear

ESP TECHNOLOGIES LIMITED

/8 DIN Level Indicator

I/O ZONE 560/583 AND OPERATION MANUAL

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Welcome to Hager Presentation

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

02/11/2015

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

M2500 Engine Controller Installation Manual

Product Tests Report

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

Moulded case circuit brakers

ME 3011C / Alarm Indication / Quick Reference Guide

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

Instructions for the fan motor control system, SILVER C

US Navy Leading the Way in Switchboard Protection

D5100 Industrial Differential Pressure Transducer

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Single phase solid state contactors ENG. User Manual DATA MANAGEMENT CONTROLS PROCESS AUTOMATION

Arc Fault - Minimize damage

Overload relays. General descriptions. Configuration of the front

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

INTERNATIONAL STANDARD

SEL Arc-Flash Solutions

AO Annunciator Module

Specification/ Data Sheet

PIR movement and presence detectors 10 A

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Conventional Smoke Detectors KFAPO

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

SEL Arc-Flash Solutions

Guide Specification Model CTG Automatic Transfer Switch

4 & 8-POINT ANNUNCIATORS Instruction Manual

Series 65 Product Guide MAN 3036

D5100 Industrial Differential Pressure Transducer

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

1S20 User Guide. Arc Fault Monitor. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide. Test Manual

Laser Particle Sensor Module PM2009

Type TEC, Transformer Electronic Control System

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

CLM-SERIES SOLID STATE POWER CONTROLLER. Product Highlights: Model Numbers:

PART 4 ELECTRICAL STANDARDS

Transcription:

Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work in or near the installation. Reduces Loss of Production The shorter the operating time of the arc flash protection unit the smaller the damage caused by the arc fault will be and the shorter the possible outage of the power supply. Prolonged Switchgear Life Cycle A modern arc protection unit increases the life-cycle expectancy of switchgear installations, investment decisions in new switchgear installations can be postponed and money can be saved by re- Vamping existing switchgear systems. Reduced Insurance Costs The faster and better the protection system of a power installation is, the more generous the insurance terms and costs will be. Low Investment Costs and Fast Installation A comprehensive arc protection is characterized by low investment costs and a fast installation and commissioning time. One successful operation of the arc flash protection units provides immediate investment pay off. Reliable Operation Function is based on appearance of light or alternatively on the appearance of light and current from an external equipment. Immune to nuisance trippings! Vast Experience Schnerider Electric is the pioneer in the field of arc flash protection with more than 10.000 VAMP arc flash protection systems and units with over 150.000 arc detecting sensors in service world-wide

02 Modern society heavily depends on an uninterrupted supply of electric power. Prolonged power outages cause loss of business to the power supplier and loss of production to the power consumer. Regardless how safe a power system is, faults do occur. This being the case the damage caused by power system faults must be kept to a minimum level. The ultimate solution is to selectively isolate the fault as fast as possible, while maintaining the operation of the healthy network parts. Secure your assets and staff safety Vamp arc flash protection maximizes the personnel safety and minimizes the material damage of the installation in the most hazardous power system fault situations. The arc protection unit detects an arc flash in an installation and trips the feeding breaker. On detection of a fault the arc flash protection unit immediately trips the concerned circuit breaker(s) to isolate the fault. An arc flash protection system operates much faster than conventional protection relays and thus damage caused by an arc short circuit can be kept to a minimum level. Why arc flash protection? When the traditional time-grading or blocking based protection coordination principle is used, the traditional protection systems may not provide fast enough protection of substation faults. Further, high-impedance type of earth-faults may cause prolonged operation times of earth-fault relays leading to the significant release of the arcing energy. These facts pose a considerable risk to operators and economical assets. VAMP arc flash protection is an extremely fast protection system for LV and MV switchgear and controlgear. It is especially designed to maximize the personnel safety and to minimize material damage caused by arc faults. Minimized damage also means limited need for repair work and enables a rapid restoration of the power supply.

0 Typical applications VAMP 120 applied for wind power applications Emergency Shut Down eneral Trip Alarm SF Alarm Trip Signal (NC) TRIP CB Trip.... VAMP 120 provides the most simple, straight- forward and economical solution designed for wind power applications TRIP VAMP 120 applied for arc flash protection at medium size power generation plant rid Possible arc flash in busbar or circuit breaker compartment trips the grid and all generator units. Should the arc flash fault happen in cable area, an emergency shut down for the concerned generator unit is activated. Z1 Z1 eneral trip eneral trip eneral trip eneral trip CB trip CB trip CB trip CB trip Z 2 Z 2 Z 2 Z 2 Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm ARC TRIP ALARM IRF

04 Product Characteristics and Highlights Common Features Operation on light only Support point or smoke sensors Straight-forward installation Cost-efficient solution Self-supervision VAMP 120 VAmP 120 Chung Mei (Taiwan) TOYO (Taiwan) Supply unit P004 Integrated 19 256 V ac/dc aux. supply Optimized for wind power and other small applications Up to 4 sensors Selective trip for 2 zones and possibility for generator set emergency trip (separate contact) Operation time 7 ms (including the output relay) Non-volatile trip status Input for current criteria for I> & L> operation NO & NC trip outputs (Zone 1) Option: photoelectric smoke detector for fire alarm early protection Option: 16 points digital I/O module with modbus RS-485 communication interface Alarm relay 7P004 Sensors & Accessories Point sensor VA1EH-x (pipe) Point sensor VA1DA-x (surface) Point Sensors Portable sensor VA1DP-5 Easy installation and replacement Enables fault location indication Surface mounting Tube mounting Continuous selfsupervision VAMP 4R Trip Multiplier Relay 4 + 4 trip outputs (4 x NO and 4 x NC) Two separate tripping groups Enables a 7 ms total operation time to a large number of CBs (controlled by binary output(bo) of VAMP 121 unit) External auxiliary power supply Sensor Mounting Plates Z- or L-shaped Wall mounting to VA1DA-x sensors (no extra holes in the switchgear)

05 Order codes VAMP 120 Order code V120 Description Arc flash protection unit Accessories Order code Description Note VAMP4RSE Trip multiplier relay 4 x NO and 4 x NC VA1DA-6 Arc sensor Cable length 6 m VA1DA-20 Arc sensor Cable length 20 m VA1EH-6 Arc sensor (pipe type) Cable length 6 m VA1EH-20 Arc sensor (pipe type) Cable length 20 m VYX001 Surface mounting plate for sensors Z-shaped VYX002 Surface mounting plate for sensors L-shaped Connection Diagrams VAMP 120 RESET 18...265Vac/dc I> Bin In 18...265Vac/dc SF Alarm TRIP 2 (NO) TRIP Alarm TRIP 1 (NO) TRIP Signal (NC) Power supply 19..265 Vdc 40...265Vac * * * * 1 4 2 or *Connection for sheeld if sheelded sensor cable used (VA1DA-20s)

06 DIMENSIONAL DRAWINS VAMP 120 VAMP 120 106 126 170 60 Supply Unit P004 Supply unit P004 Alarm Relay P007 Alarm relay P007 99 114.5 22.5 Arc Sensor VA1DA- Arc sensor VA1DA- Arc Sensor VA1EH- VA1EH 62 11 Mounting Plates for VA1DA Mounting plates for VA 1 DA

07 TECHNICAL DATA VAMP 120 unit Power Supply Us 19...265 V dc / 40...265 V ac Pmax TRIP Contacts Rated voltage Continuous carry Make and carry for 0.5 s Make and carry for s 4 W 2 pcs 250 V ac/dc 5 A 0 A 15 A t> 7 ms Digital Inputs Rated voltage Number of inputs 2 18...265 V ac/dc P004 supply unit Phoenix type as used in table below Input Data Nominal input voltage MINI-PS-100-240AC/24DC/1. 100 V AC... 240 V AC Nominal output voltage 24 V DC ±1% AC input voltage range DC input voltage range AC frequency range DC frequency range Output Data 85 V AC... 264 V AC 90 V DC... 50 V DC 45 Hz... 65 Hz 0 Hz Nominal output voltage 24 V DC ±1% Output current 1. A (-25 C... 60 C) P007 alarm relay Phoenix Type DEK-REL-24/21 Coil side Nominal input voltage Un Contact type 24 V DC Single contact, 1-PDT Input voltage range in reference to Un 0.8... 1.1 Limiting continuous current Nominal input current at Uin Contact material Typical response time Maximum switching voltage Minimum switching voltage Maximum inrush current Min. switching current Limiting continuous current 6 A 9 ma AgSnO 8 ms 250 V AC/DC 12 V AC/DC 6 A 10 ma 6 A

08 Disturbance standards Test voltage standards Emission EN 61000-6-4 Conducted EN 55011, IEC 60255-25 0.01-0 MHz Insulation Test Voltage IEC 60255-5 2 kv, 50 Hz, 1 min Emitted EN 55011, 0-1 000 MHz Impulse Test IEC 60255-5 Immunity EN 61000-6-2, IEC 60255-26 5 kv, 1.2/50 ms, 0.5 J Static discharge (ESD) EN 61000-4-2, class III, IEC 60255-22-2 6 kv contact discharge 8 kv air discharge Fast transients (EFT) Surge EN 61000-4-4, class IV, IEC 60255-22-4 4 kv, 5/50 ns, 5 khz, +/- EN 61000-4-5, class III, IEC 60255-22-5 2 kv, common mode 1 kv, differential mode Conducted HF field EN 61000-4-6, IEC 60255-22-6 0.15-80 MHz, 10 V Mechanical standards Shock Response Shock Withstand Bump Test IEC 60255-21-2, class I half sine 11 ms, Acceleration 5 g 6 directions, pulse each dir. IEC 60255-21-2, class I half sine 11 ms, Acceleration 15 g 6 directions, pulse each dir. IEC 60255-21-2, class I Emitted HF field EN 61000-4-, IEC 60255-22- 80-2000 MHz, 10 V / m EN 61000-4-8 Power frequency magnetic field (VAMP 121) EN 61000-4-9 Pulse magnetic field (VAMP 121) IEC 60255-22-1 1 MHz Damped oscillatory waves (VAMP 121) Vibration Sinusoidal Response half sine 16 ms, Acceleration 10 g 6 directions, 1000 pulse each dir. IEC 60255-21-1, class I Amplitude 0.05 mm Frequency 10...150 Hz Acceleration 0.5 g directions, 1 sweep, rate 1 oct/min Sinusoidal Endurance IEC 60255-21-1, class I DEVICE Track record Frequency 10...150 Hz Acceleration 1 g directions, 20 sweeps, rate 1 oct/min Schneider Electric s VAMP Range specializes in arc flash protection relays for power system. Environmental conditions Schneider Electric VAMP s arc flash fault protection functionality enhances the safety Operating Temperature -10... +55 C of both people and property and has made Schneider Electric VAMP a pioneer in the field Transport and Storage Temperature - 40... +70 C of arc flash protection with more than 10.000 VAMP arc flash systems and units with over 150.000 arc detecting sensors in service worldwide. All Schneider Electric VAMP products meet the latest international standards and regulations. Our success is based on competitive standard products, constant development by our designers possessing experience from arc flash relay generations. Schneider Electric Industries SAS 5, rue Joseph Monier CS 02 F - 92506 Rueil Malmaison Cedex (France) Tel.: + (0) 1 41 29 70 00 RCS Nanterre 954 50 49 Capital social 896 1 776 www.schneider-electric.com NRJED11107EN Relative Humidity Degree of protection (IEC 60529) < 75% (1 year, average value) < 90% (0 days per year, no condensation permitted) IP 20 As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Design: Schneider Electric Industries SAS - Sonovision Photos: Schneider Electric Industries SAS Printed: Altavia Connexion - Made in France This document has been printed on recycled paper. 0-2012 ART889 2012 Schneider Electric Industries SAS - All rights reserved