ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Similar documents
Installation, Operating and Maintenance Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Interface Modules for SENTRI

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Sita200plus. 200detectors. Single loop analogue addressable System

INPUT / OUTPUT MINI MODULES

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Intellia Sounder Bases and Sounder Beacon Bases

Application, Installation, Operation & Maintenance Manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

SOUNDER CONTROL MODULE SCM-AS4

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Excel-EN Conventional Fire Control Panel

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

SINGLE MONITORED INPUT UNIT BN-303

Control Panel Engineering and Commissioning Instructions

System 800 Addressable Fire Detection & Alarm System

Reflective Optical Beam Smoke Detector User Guide

Vega Devices.

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

OPERATION AND INSTALLATION MANUAL

Quickheat 30 weather compensated boiler control

M2500 Engine Controller Installation Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

EXTINGUISHING AGENT RELEASE MODULE

XP95 Sounder VAD Base

SOUNDER BASES AND SOUNDER BEACON BASES

The supplier and installer of the system should be approved by the local civil defence authority.

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

The EN54 Part 2 & 4 Fire System

FR-4000 & FR-8000 Fire Alarm Monitor Installation Manual

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Intelligent Security & Fire Ltd

Addressable NAC Output Module D327A

Addressable Loop Modules

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Intelligent addressable fire alarm control panel

AU MX Digital Loop Card Installation Instructions

End To End Optical Beam Smoke Detector. Additional Information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

IFD-E Flame Detector User Manual

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

MINERVA MX. 800 Series Ancillary Equipment

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

2000 Series Sensors Installation Guide

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Fire Product Catalog

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

IFD-E Flame Detector User Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

IGD. O p e r a t i o n a n d M a i n t e n a n c e V International Gas Detectors. Triton House Crosby Street Stockport SK2 6SH England

FEC400 Series. Installation Manual

Multi-Gas-Controller MGC2

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Intelligent Security & Fire Ltd

Heat Sensor Cable Alarm Units DT650L / DT950L

BS-316. Gas detection control panel up to 16 inputs. Installation operation manual

Interface and EOL Modules 8

STANDARD TECHNICAL SPECIFICATION FOR AN ANALOGUE ADDRESSABLE FIRE DETECTION SYSTEM

Model 17A00 Expansion Enclosure

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Solution F2. Fire Alarm Control Panels one step ahead.

DOLKPL1KB DOLKPS1KB DOLKSF1KB

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Flair 500 Series Annunciators

Fire and Gas Monitoring Panel ST7-HV

SOLO Single Loop Addressable Fire Control Panel

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

QA16 Addressable System

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Fire control panel detect 3004 plus and accessories

Input/Output Modules Data Sheet

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Using Non-Twisted Flat Cable in Analogue Addressable Retrofits

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Motorised Infrared Optical Beam Smoke Detector. User Guide

Model 5610 Infra-red Transit Heat Sensor

Quick Selection Guide Fire Systems LSN Periphery

Carbon Monoxide Transmitter

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Danfoss gas detection units

The EN54 Part 2 and 4 Fire System

MKII PROTOCOL DEVICE SUPPLEMENT DEVICE SUPPLEMENT

AIS750 Series Alarm Annunciator

Operating Instructions

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Motorised Infrared Optical Beam Smoke Detector. User Guide

FC700A Fire detection control unit

Precept Marine Control Panel Application Guide

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

ZNS MICROPROCESSOR BASED CONVENTIONAL FIRE ALARM CONTROL PANEL. Installation & Operation Manual

Transcription:

Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel using normally open dry contact connections. The connection to the input is monitored for fault (open or short circuit) and Alarm conditions. The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System, for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems, etc. Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED An 8 way D.I.L switch is provided to configure the module s address. This value can be set in the range 1 to 125. The following programmable functions are available: Input Activation Mode, Delayed Input Alarm Activation, Output Delayed Activation. Features Fast Activation Response Loop Powered Five Status LEDs provided Low Power Consumption Module features an integral short-circuit loop isolator Single mains rated relay contact Page 1

Connections Device is polarized LOOP IN LOOP OUT Input Resistance Values End of line monitoring resistor 22K Alarm resistor (4K7) in series with normally open contact Fault Short circuit - <2K2 Open circuit - >47K Normal - 8K2 to 47K Fire - 2K2 to 8K2 D.I.L Switches Configuration Switches 1-7 Used to configure the module s address Switch 8 Programming Mode Address Switches Binary Weights 1 on = 1 4 on = 8 7 on = 64 2 on = 2 5 on = 16 3 on = 4 6 on = 32 Page 2

Address Settings Page 3

Connections Input Monitored for Open and Short Circuit - Can be driven by conventional panel s zone repeater outputs. Each I/P should be fitted with 22 K Ohm end-of-line resistor. Fire condition set with 4.7 K Ohm resistor in parallel with e.o.l resistor. Output The mains rated relay output provided is a latching relay. In order to reset it apply reset to the panel or alternatively remove power to the panel and re-apply. After a few seconds the relay will revert to it s default position. Reporting Details In order to indicate the status of the module s working condition, the following LEDs are provided: Status: This will flash GREEN every time the address associated with the module is polled by the addressable panel. Input Status: An I/P status RED LED is provided for the input. This RED LED will be illuminated continuously whenever there is a FIRE condition present at the input terminals. The analogue value reported by the module in this state is 64. Output Status: An O/P status RED LED is provided for the output. This RED LED will be illuminated continuously whenever the output relay is activated. Fault: This YELLOW LED will be activated whenever there is either an open or short circuit fault on that particular input. If there is an open or short circuit condition, the analogue value reported to the addressable panel is 4. SC Fault: This YELLOW LED will be ON when there is a short circuit in the loop. Technical Specifications MODEL ZIOU/230 Part No 48-125 Description Supply Voltage Loop Current - Quiescent (I Q ) Loop Current - Alarm Loop Current - Fault Loop Current - Output Active Output Relay Contact Rating Mains Switching I/O Unit - Standard Protocol Loop Powered - 17V to 30V DC 1.3 ma 2.9 ma 2.9 ma (SC) - 2.6 ma (OC) 2.8 ma Max. Cable Size 2.5 mm 2 Case Material Max. Humidity Operating Temperature Dimensions Weight 8A 250 VAC/30V DC ABS 95% RH Non-Condensing -10 o C to 50 o C 150 (W) x 90 (L) x 32 (H) 210g inc. packaging Page 4

Installation Manual Modification History ***Do Not Print this Page when creating PDF of the manual*** Issue Date Changes 1.0 06/2013 Initial Release 1.1 29/07/2013 Format changed to Zeta 1.2 04/11/2013 MKII version removed from table on p.4 Page 5