AAO100 Dosing pump. Measurement made easy. Introduction

Similar documents
Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Hazardous Area Zirconia Oxygen Systems

Low Temperature Zirconia Oxygen Analyzer

Contents. 1. Instructions for safety and use 20

Operation of heat exchangers

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

Electromagnetic Flowmeters

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

instrumentation Hydrogen Analyzer Systems Unrivaled safety and technical expertise from the market leader in hydrogen measurement

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Instructions Manual CTB CTB 9407

BAMOSOFT Control. Water hardness monitor INSTRUCTIONS MANUAL DUR. BAMOSOFT Control. Water hardness monitor / M1 01 C

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

Rycroft Supapac Plate Heat Exchangers

ONTIME TIMER SPECIFICATION

PRODUCT CONFORMITY CERTIFICATE

Verdi 90 & 120 Ceiling Hood Re-Circulating and Ducted Installation & User Instructions

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Rigoletto 60,90 & 120 Built-In Cupboard Hood

Short form catalogue Domestic equipment Movement detectors

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

Product waste disposal - Protection of the environment:

Indumax CLS50/CLS50D. Operating Instructions. Analog or digital sensors with Memosens protocol For inductive measurement of conductivity in liquids

AS950 REFRIGERATED SAMPLERS

Multi-Mode Electrode pro

Hamlet 60 & 80 Wall Hood

Island Hood KCH110ST/KCH900IS. User and Installation Instruction

AKRON BOBATH Models 4411, 4412, 4421, 4422 USER MANUAL

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Nabucco Island Hood. Installation & User Instructions. Please read these instructions carefully before installing and operating this appliance

Technical Manual for the Alarm Pull Station PH1

DR. E. HORN GmbH / Schoenaich, Germany

Operator s Manual. Model # PS Arch Chemicals, Inc Lower River Road P.O. Box Box 800 Charleston, TN PULSAR

ESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

USER MANUAL. 60cm, 3 burners, Hob AKC 630

Decade Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation, Operating and Servicing Instructions

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

Instruction Manual for Bench-Top Cleaning Baths

Installation, Operation & Maintenance Guide

ENGLISH. Attaching the handle (Fig. A) Attaching the steam head (Fig. B) Attaching the hand held steam cleaner (Fig. C) (Original instructions)

Retractable ph/orp Sensor

ENGLISH. (Original instructions) Attaching the hose (Fig. A) Attaching the variable steam jet nozzle (Fig. B)

Leonardo 90 Wall Hood

InfinityLab Quick-Connect Bio-inert Heat Exchanger

Elektra 90 & 120 Downdraft Extractor Installation & User Instructions

Zirconia Oxygen Probe

Dissolved Oxygen Sensors

AS950 PORTABLE SAMPLERS

Manual Pressure Pump Generators Standard Laboratory Models Operation and Seal Packing Instructions

Installation and Operating Instructions. Models: T4-12LOW-9IS

"VIP 2" ADVANCED LUBRICATION CONTROLLER

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

AUTOMATIC GRANULAR ICE FLAKER

Flameproof Manual Call Points

INSTALLATION AND USER MANUAL

MicrOTDR. Optical Fault Locator. User Manual

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

Dutch Bucket Row Kits

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -6000C, -7500C, C. Service manual. Oxiperm 164C 4-10 kg Service en

BLAST-IT-ALL BUMPER BLASTER

CENTRAL AIR CONDITIONER SPLIT SYSTEM

Operating Instructions Wine storage refrigerator 12/

Operating Guide IM/C1900-OGR Rev. J. C1900 Series Circular Chart Recorders

UV I UNIT030W / UV I UNIT055W

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

IFO6820. Ifo Sign Junior Toilet S Trap. Product Code. Call

Pear Kitchen Sink Tap

ph Measuring System Start-up and maintenance manual e Contents

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

9.0 Systems For Domestic Water Installations

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

CEILING FAN OWNER'S MANUAL

Installation instructions

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Zirconia Oxygen Analyzer

AVANI Grinding Booth

TECH REPORT 200: Use of Water Traps and Drying Filter with the FX-5000 Tension System. Document: Water Trap and Drying Filter Tech Report, Rev. 8.

1592P01. for liquids in piping DN

Controller Specification Sheet

Electron Microscopy Sciences

MIX Boiler & Font Range Service Manual

Transcription:

ABB MEASUREMENT & ANALYTICS USER GUIDE IM/DOSPMP REV. B Dosing pump Measurement made easy Dosing pump Introduction The dosing pump is used to introduce a cleaning solution to the jetwash of an AP200 ph system at preset intervals. The timing, duration and amount of cleaning is controlled by an AX400 ph analyzer.

For more information Further publications are available for free download from: www.abb.com/analytical or by scanning this code: Search for or click on AP200 Rugged ph/redox (ORP) sensor systems Data Sheet AP200 series Rugged ph/redox (ORP) sensor systems User Guide DS/AP200-EN IM/AP200

Contents 1 Introduction...2 2 Installation...2 2.1 Fitting the Pump to the Reservoir...2 2.2 Electrical Connections...3 2.2.1 Mains Connections...3 2.2.2 Analyzer Connections...3 2.3 Settings...3 2.4 Pump Tubing Connections...4 2.4.1 AP200 Connection...4 2.4.2 Connecting the Tubing to the Pump...5 3 Analyzer Settings...6 4 Cleaning Solutions...7 5 Dimensions...7 Notes 8 IM/DOSPMP Rev. B 1

1 Introduction The dosing pump is used to introduce a cleaning solution to the jetwash of an AP200 ph system at preset intervals. The timing, duration and amount of cleaning is controlled by the AX400 ph analyzer. 2 Installation 1 Introduction Note. Installation must be carried out in accordance with local water company and council by-laws. 2.1 Fitting the Pump to the Reservoir Referring to Fig. 2.1, secure the pump to the reservoir using the two screws A provided. AX400 Analyzer Dosing Pump Reservoir (water or cleaning solution) Level Sensor Fig. 1.1 Jetwash Schematic The AP200 jetwash system enables automatic cleaning of both the measuring element and the reference junction by spraying water or a cleaning solution at them in situ, thus reducing system maintenance requirements. A Maintenance Cleaning Screw Twin Wash Nozzles Fig. 2.1 Fitting the Pump to the Reservoir Fig. 1.2 Location of the Jetwash Nozzles 2 IM/DOSPMP Rev. B

2 Installation 2.2 Electrical Connections 2.2.1 Mains Connections The power supply range is 100 to 230 V AC. Caution. Before making any electrical connections, ensure that the power supply is switched off. Referring to Fig. 2.2: 1. Connect the mains plug A. 2. Push the mains plug into the pump socket B. 3. Fasten the mains plug cover C. 2.2.2 Analyzer Connections Referring to Fig. 2.3: 1. Plug the controller cable into the dosing pump A. 2. Cut the controller cable's Blue wire back to the outer insulation. 3. Remove the analyzer's terminal cover plate see Section 6.4.1. of the analyzer's User Guide (IM/AX4PH). 4. Twist the controller cable's Black and Brown wires together and connect to terminal A10 B. 5. Twist the controller cable's White and Grey wires together and connect to terminal A12 C. 6. Refit the analyzer's terminal cover plate see Section 6.4.1. of the analyzer's User Guide (IM/AX4PH). Earth A B AX400 Terminal block A Live Neutral C B Black Brown White Grey C A9 A10 C A11 N/C A12 N/O A13 A Fig. 2.2 Mains Connections Fig. 2.3 Analyzer Connections 2.3 Settings For optimum cleaning, set the dosing pump to: Stroke Length 100 Multifunction Switch External the AX400 ph Analyzer controls the frequency and duration of the cleaning cycle. Refer to Section 3, page 6 for analyzer configuration instructions. IM/DOSPMP Rev. B 3

2 Installation 2.4 Pump Tubing Connections 2.4.1 AP200 Connection Note. Wash tubing is not supplied. Use 6mm OD semi-rigid polyethylene tube (part no. 0212035). Referring to Fig. 2.4: 1. Remove jetwash port sealing nut A and retain for further use. Note. The sealing nut must be refitted if the jetwash tubing is removed. 2. Slide the connector B and the ferrule C onto the tubing. 3. Push the tubing onto the jetwash port D and tighten the connector to a torque of 0.6 Nm. A B C D Fig. 2.4 AP200 Connection 4 IM/DOSPMP Rev. B

2 Installation 2.4.2 Connecting the Tubing to the Pump Referring to Fig. 2.5: 1. Cut the end of the tubing straight across. 2. Slide union nut A and circlip B over the tubing. 3. Push the end of the tubing over nozzle C. 4. Ensure that O-ring D is seated correctly. 5. Fasten the union nut to valve E while pushing the tube onto the nozzle. A B C D E Fig. 2.5 Connecting the Tubing to the Pump IM/DOSPMP Rev. B 5

3 Analyzer Settings 3 Analyzer Settings Access the Wash Cycle Configuration menu see Section 5 of the AX400 ph analyzer s User Guide (IM/AX4PH). ----- Cont. Pulsed Wash Mode Wash Mode Set to Cont. (continuous) for use with the dosing pump. Hours 15 Mins Wash Frequency Wash Frequency Set the wash frequency required. Wash frequency is set in 15 minute increments between 15 and 45 minutes, then in 1 hour increments between 1 and 24 hours. Mins 15 Secs Wash Duration Wash Duration Set the wash duration required. Wash duration is set in 15 second increments between 15 and 45 seconds, then in 1 minute increments between 1 and 10 minutes. 1.0Mins Recovery Period Recovery Period Set the recovery period required, between 0.5 and 5.0 minutes in 0.5 minute increments. Frequency Wash Duration Recovery Period Continuous t Fig. 3.1 Wash Cycle Frequency 6 IM/DOSPMP Rev. B

4 Cleaning Solutions 4 Cleaning Solutions The AP200 spray jet tube is constructed in 316 stainless steel. Possible contaminants together with recommended cleaning solutions are shown in Table 4.1. 5 Dimensions Dimensions in mm (in.) Contaminant Grease and oil Resins Limestone and carbonates Metal hydroxides Cyanides Heavy biological Proteins Fibres Light biological Cleaning Solution Alkaline detergents or water-soluble solvents such as alcohols Dilute alkalis 1M nitric acid 1M sulphuric or nitric acid Mixture of 1M sulphuric or nitric acid and pepsin (saturated) Pressurized water with or without wetting agents Pressurized water 740 (29) Latex Potable water Pressurized cold water Citric acid Ø 420 (16.5) Table 4.1 Recommended Cleaning Solutions Fig. 5.1 Overall Dimensions IM/DOSPMP Rev. B 7

Notes Notes 8 IM/DOSPMP Rev. B

Sales Service

ABB Limited Measurement & Analytics Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 Email: instrumentation@gb.abb.com ABB Inc. Measurement & Analytics 125 E County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. ABB 2018 IM/DOSPMP Rev. B 08.2018