Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Similar documents
SIL725 Safety Annunciator

LEAKSTOPPER 1 Single zone water leak detection system

INSTRUCTION MANUAL A131 High Level Audible Warning System / Battery backup

LEAKSTOPPER RANGE Multizone water leak detection systems

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Excel-EN Conventional Fire Control Panel

FireNET Plus Wiring Instructions

AO Annunciator Module

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

TECHNICAL DATA OBSOLETE

Flopurge TS. Operation Manual

AL600ULADA. NAC Power Extender. Installation Guide

New Silent Alert Fire Safe System

Emerald 3000 MK3 GJD010 Lighting Controller

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Conventional Fire Alarm System 2014 V1.2

Installation, Operating and Maintenance Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

EXTINGUISHING AGENT RELEASE MODULE

DRAFT 20 October 2014

The Remote alarm Panel, TYPE RAPv2

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

INPUT / OUTPUT MINI MODULES

ESP TECHNOLOGIES LIMITED

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

System 9000TS Sequence of Events Recorder

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

Flostop TS D7E and A8E. Operation Manual

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Intelligent Security & Fire Ltd

Technical Manual. Level Alarm Unit CARLA & WIDS

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

System 9000TS Event Recorder

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Intelligent addressable fire alarm control panel

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

C-Bus Four Channel Analogue Output Unit Installation Instructions

AIS750 Series Alarm Annunciator

Addressable and Conventional Fire Protection

5000 INSTALLATION GUIDE

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

Series 725 Programmable Alarm Annunciator

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

30.45 Electric Release PDRP-2001

Intelligent Security & Fire Ltd

BX444-Mc Gas Detector

TrueAlarm Fire Alarm Controls

SUPREMATouch. Modular Fire & Gas Detection System

Application, Installation, Operation & Maintenance Manual

Commercial and Light Industrial Fire Alarm Control Panel

SUPREMATouch. Modular Fire & Gas Detection System

STA16 SELECTRONIC ALARM ANNUNCIATORS DESIGN, INSTALLATION AND OPERATING MANUAL STA16

Conventional Leaflets

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

Accessible Toilet Alarm

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

X10 Mini, Midi & Maxi

Universal fault annunciator for panel mounting

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

ANALOX 3000 Carbon Monoxide Monitor

Silent Alert Fire Safe System

SOLO Single Loop Addressable Fire Control Panel

1 INCA INCA MODEL FPC FIRE PUMP CONTROL PANEL. (Star Delta/D.O.L) USER MANUAL Inca Reference FPC Revision 1.0

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

VACIE REFERENCE GUIDE REVISION 1.2.6

Interface Modules for SENTRI

Loadstar AC/DC Systems

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Operation and Maintenance Manual

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

OPERATION AND INSTALLATION MANUAL

Nuclear Associates

An introduction to... Sigma

FEC403EN Installation Manual

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

HEATFAST HF9101-V1 AMBIENT SENSING TRACE HEATING THERMOSTAT

How to use the BTRM in Remote Enclosures

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Unity DAU Voice Alarm System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1


Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Transcription:

Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm circuits IEC61508 SIL2 level safety rating Environmentally Protected to IP65 RoHS Compliance to 2011/65/EU (RoHS2) Reset/Test/Mute key switch Remotely Mute and Reset Alarms Repeat outputs provided per alarm. Instrument failure output provided Aesthetic wallmount design. Low power consumption. 85264Vac or optional 24Vdc powered; both with duplicate terminals Battery backup builtin for AC units Overview The Omni2 alarm annunciator is a compact wall mounted visual alarm indicator designed to safeguard against personnel inadvertently entering plant areas where abnormal conditions are present. Typical Applications Include: Warning of airborne contamination & high radiation conditions in the nuclear industry Warning of Oxygen deficiency Warning of other hazardous environments and unsafe conditions. Position the Omni2 on the wall adjacent to the entrance to an environmentally segregated area & connect the Omni2 to the monitoring instrument. If hazardous conditions are present in the area, a large bright flashing visual warning of the hazard is displayed, to deter entry to the area. High Reliability Design The Omni2 features full dual redundant design for each of the two alarms, solid state logic and visual display, providing a highly reliable alarm system, meeting or exceeding the functional safety requirements of these critical applications. The Omni2 is designed to meet the requirements of SIL2 safety systems as defined in IEC61508. Operation Once an alarm has occurred, the visual display will continue to flash, and the audible alert will continue to sound until reset by the keyswitch OR by the Remote Reset. The alarm cannot be reset if the alarm condition is still present. The internal audible will give a warning of a dangerous condition, even if the display is out of sight of the personnel. Testability The Omni2 provides features to allow easy routine testing of the alarm system. A green indicator light on the front of the unit provides indication that the unit is healthy. If a fault is detected in either of the dual redundant alarms, this indicator will extinguish, and the instrument failure output will activate warning of the failure. In addition, the Reset keyswitch AND the Remote Reset can be used to test the alarm display. If the reset keyswitch OR the Remote Reset is activated while no alarm is present, the alarm displays will illuminate. Installation The Omni2 is housed in an aesthetic low profile wall mount enclosure that has an IP65 protection rating (according to EN 60529). Options for mechanical mounting include internal mounting holes or external mounting brackets (supplied). Wiring entry is provided through the bottom of the unit via up to five 20mm glands. Datasheet DSC1190BR19.pdf Sheet 1 or 5

SPECIFICATIONS Power Supply 85264Vac (Standard version) Supply Voltage Input Supply Current Switchon Inrush current 24Vdc (optional version) 85264Vac 4763Hz < 0.1A/230V < 0.15A/115V < 1A (50Hz half cycle duration) Supply Voltage 21,627.6Vdc at 0.7A Alarm Inputs Input Type Action Input Contact Quantity Input Open Circuit Voltage Input Short Circuit Current Maximum Closed Circuit Loop Resistance Minimum Open Circuit Loop Resistance Wire size Operator Controls Type Function Alarm Window Display Quantity Lamp Type Window Size Window Legend Potential Free Contacts Normally closed; Open to alarm. Terminals provided for up to five input contacts wired in series per alarm. (see wiring diagram) 15Vdc maximum 5mA maximum <200 ohms total per alarm point. >100kohms to guarantee open contact detection 1.5mm 2 (17SWG/15.5SWG) max. One springloaded Keyswitch for both alarm points. Reset / Test / Mute 2 Alarm windows Bright Backlit Solid State (LED) 180mm x 70mm Audible Alert (Internal) Type Audible Selection Audible Alert (External) Rating Standard legend. (Legend can be specified when ordering) Internal Piezo Sounder User can enable/disable via link. 12V 100mA max. Connection Via terminals 27 and 28 Relay Contact Outputs Outputs provided Contact Type Contact Rating Isolation Temperature Range Operating Temperature Storage Temperature 2 x Repeat Alarm Output Contacts 1 x Instrument Fail Output Contact. Potential free Form A contact (Contact closed while normal, opens on alarm/fault) 3A/30Vdc, 3A/250Vac, 90W 1000Vac from contact to other circuits 20 C 60 C (4 F 140 F) 10 C 70 C (14 F 158 F) Battery Charger with builtin Battery* Float Voltage (at 25 C) Battery Quantity & Type Dimensions (L x W x H) Charging Current 13.7V13.9V (12Volt Battery, trickle charger) 1 off 12V 0.8Ah 96 mm x 25 mm x 62mm 0.1Amp Max *Battery charger and battery not included in DC versions Mechanical Outside Dimensions Mounting Weight Unpacked/Packed Compliance to Standards Width: 230mm Height: 300mm Depth: 66mm Can be mounted using external mounting feet or through holes within the housing. 1.3kg/1.6kg approx. Safety EN 60950:1995 Emissions EN55011:2008 Group I Class A Immunity ESD IEC 6100042: 2001, level 3 Immunity RF Fields IEC 6100043: 2003, level 3 Immunity Fast Transients Vibration Functional Safety RoHS Compliance Ingress Protection (I.P.) Ordering Information Order Code* C1190B Model Window Text IEC 6100044: 2004 2 kv AC power port 1 kv input/output lines IEC6006826: 1995 10150Hz. 1g Designed to meet IEC61508 SIL2. 2011/65/EU (RoHS2) IP65 Description Omni2 Standard 85264Vac Supply Door Warning Sign Single Channel Alarm Annunciator with Yellow Danger Window (Top) & White Keep Out Window (Bottom). For non standard options, refer to table below Window Colours Power Supply C1190B X X X X Note: Channel 0=Std 1 0=Std 2 0=85264Vac 0=Single 1=Custom 3 1=Custom 3 2=24Vdc 1=Dual 1. Standard Top Window Text is Danger and standard Bottom Window Text is Keep Out. 2. Standard Top Window Colour is Yellow and standard Bottom Window Colour is White. 3. For Custom Window text and colours, please specify both text and colours (choice of White or Yellow) for EACH of the windows. 4. Typical custom order code C1190B1101 would be an Omni2 Door Warning Sign Dual Channel Alarm Annunciator with Custom Window Text (specify for each window), Custom Window Colour (specify for each window [White or Yellow]) and 85264Vac Power Supply. Datasheet DSC1190BR19.pdf Sheet 2 of 5

288 314 300 ALARM SEQUENCE STATE DIAGRAM STANDBY RESET WHILE OFF OFF AB RESET WHILE STATE 3 ON AB STATE 1 ON STATE 2 OFF RESET WHILE AB Alarm Flashing Sequence Momentary (Fleeting) Alarm, Manual Reset MECHANICAL DETAILS 71.5 66.5 244 230 218 Ø5.2 Datasheet DSC1190BR19.pdf Sheet 3 of 5

ELECTRICAL TERMINAL LAYOUT (220V/110Vac version) 35 36 37 38 39 40 32 33 34 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 ELECTRICAL TERMINAL LAYOUT (24Vdc version) 35 36 37 38 39 40 32 33 34 29 30 31 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Datasheet DSC1190BR19.pdf Sheet 4 of 5

ELECTRICAL CONNECTION DIAGRAM 85264Vac Power Input (Standard) L N E 21.627.6Vdc Power Input (Optional) E 29 30 31 32 33 34 Power Supply/Isolation Circuitry A INPUTS Contacts must be closed when normal. (Link all unused inputs) B INPUTS (linked to A inputs on C1190B) Contacts must be closed when normal. (Link all unused inputs) INA INB INC IND INE Repeat Output A Instrument Failure Output INA INB INC IND INE Repeat Output B on Dual Channel C1190B (Same as Repeat Output A on Single Channel C1190B) Horn Output 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 A DUAL REDUNDANT LOGIC B DUAL REDUNDANT LOGIC Remote Reset (short to remotely reset alarm) 39 40 NOTE: 1. All output contacts are closed when normal 2. For 24Vdc input option, connecting either the positive or the negative of the supply to earth will not affect Omni2 operation Datasheet DSC1190BR19.pdf Sheet 5 of 5